Multiplanar Fixation for Patella Fractures Using a Low-Profile Mesh Plate.

Abstract:

:Patella fractures are challenging orthopaedic injuries. Many commonly used fixation techniques can be ineffective and lead to poor clinical outcomes even with satisfactory reductions and fracture healing. In this investigation, we present the technique of cage plate fixation of patella fractures and the clinical outcomes of 9 initial patients surgically treated at our institution. This technique allows direct visualization of the articular reduction, provides multiplanar fixation, effectively stabilizes inferior pole comminution, and reduces the risk of patella vascular disruption. Using this technique, we have achieved excellent functional and radiographic outcomes.

journal_name

J Orthop Trauma

authors

Lorich DG,Warner SJ,Schottel PC,Shaffer AD,Lazaro LE,Helfet DL

doi

10.1097/BOT.0000000000000415

subject

Has Abstract

pub_date

2015-12-01 00:00:00

pages

e504-10

issue

12

eissn

0890-5339

issn

1531-2291

journal_volume

29

pub_type

临床试验,杂志文章
  • Lengthening of the femur over an existing intramedullary nail.

    abstract::Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities a...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181f92d6e

    authors: Kim HJ,Fragomen AT,Reinhardt K,Hutson JJ Jr,Rozbruch SR

    更新日期:2011-11-01 00:00:00

  • Inappropriate transfer of patients with orthopaedic injuries to a Level I trauma center: a prospective study.

    abstract:OBJECTIVE:The objective of this study was to analyze the appropriateness of transfer of patients with orthopaedic injuries to a Level I trauma center from surrounding Level II to IV centers. DESIGN:A prospective study was conducted over a 5-month period by collecting data on all orthopaedic patients being transferred ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181b18b89

    authors: Thakur NA,Plante MJ,Kayiaros S,Reinert SE,Ehrlich MG

    更新日期:2010-06-01 00:00:00

  • Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures.

    abstract:OBJECTIVE:To determine the effectiveness of exchange reamed nails for treatment of aseptic femoral delayed unions and nonunions. DESIGN:Retrospective chart review. PATIENTS:Nineteen patients admitted to the Carolinas Medical Center Level I trauma center from 1990 to 1996 for repair of femoral shaft fracture nonunion ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200006000-00005

    authors: Weresh MJ,Hakanson R,Stover MD,Sims SH,Kellam JF,Bosse MJ

    更新日期:2000-06-01 00:00:00

  • Fabrication of an Interlocked Antibiotic/Cement-Coated Carbon Fiber Nail for the Treatment of Long Bone Osteomyelitis.

    abstract::Successful management of intramedullary long bone osteomyelitis remains a challenge for both surgeons and patients. Patients are often immune compromised and have endured multiple surgeries. Treatment principles include antibiotic administration (systemically ± locally), surgical debridement of the infection site, and...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000587

    authors: Mauffrey C,Butler N,Hake ME

    更新日期:2016-08-01 00:00:00

  • Biomechanical effects of internal fixation of the distal tibiofibular syndesmotic joint: comparison of two fixation techniques.

    abstract::This biomechanical study compares two methods of internal fixation of the tibiofibular syndesmosis used in Weber type C malleolar fractures of the ankle. The transverse syndesmotic 3.5-mm screw was compared with two 1.5-mm Kirschner wires introduced obliquely across the distal tibiofibular syndesmosis. The influence o...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199406000-00006

    authors: Peter RE,Harrington RM,Henley MB,Tencer AF

    更新日期:1994-01-01 00:00:00

  • Use of Inlet-Obturator Oblique View (Leeds View) for Placement of Posterior Wall Screws in Acetabular Fracture Surgery.

    abstract::Posterior wall (PW) fractures are the most common fractures requiring surgical fixation in acetabular surgery. Extra-articular screw placement must be confirmed intraoperatively. Herein we describe the use of the inlet and obturator oblique view (the Leeds view) for screw placement in elementary PW and in associated b...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0000000000000724

    authors: Tosounidis TH,Giannoudis PV

    更新日期:2017-04-01 00:00:00

  • Outcomes of Surgical Treatment of Periprosthetic Acetabular Fractures.

    abstract::Periprosthetic acetabular fractures sustained following acute trauma after total hip arthroplasty are rare and historically have poor outcomes. This article reviews 5 cases and the treatment algorithm used by a single orthopaedic surgeon specializing in acetabular fracture care with a co-surgeon specializing in arthro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001400

    authors: Hickerson LE,Zbeda RM,Gadinsky NE,Wellman DS,Helfet DL

    更新日期:2019-02-01 00:00:00

  • Outcomes After Hemiarthroplasty for Proximal Humerus Fracture Are Significantly Affected by Hand Dominance.

    abstract:OBJECTIVES:Hand dominance has been reported to be an important factor affecting outcomes after upper extremity trauma but remains unstudied after hemiarthroplasty for fracture. This study determined whether dominance affected outcomes after hemiarthroplasty for proximal humerus fractures. DESIGN:Retrospective cohort s...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000294

    authors: LeBlanc JE,MacDermid JC,Faber KJ,Drosdowech DS,Athwal GS

    更新日期:2015-08-01 00:00:00

  • Biomechanical testing of a new design for Schanz pedicle screws.

    abstract::Standard 5-mm AO Schanz pedicle screws were biomechanically compared with a new design, featuring 6-mm threads with a 5-mm core diameter continuous with the shaft. One each of the two screw designs was surgically inserted into the matching pedicles of 32 cadaveric vertebrae. The pull-out strengths of the screws were t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199308000-00015

    authors: Willett K,Hearn TC,Cuncins AV

    更新日期:1993-01-01 00:00:00

  • Teamwork in Trauma: System Adjustment to a Protocol for the Management of Multiply Injured Patients.

    abstract:OBJECTIVES:We developed a protocol to determine the timing of definitive fracture care based on the adequacy of resuscitation. Inception of this project required a multidisciplinary group, including physicians from anesthesiology, general trauma and critical care, neurosurgery, orthopaedic spine, and orthopaedic trauma...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000383

    authors: Vallier HA,Moore TA,Como JJ,Dolenc AJ,Steinmetz MP,Wagner KG,Smith CE,Wilczewski PA

    更新日期:2015-11-01 00:00:00

  • Functional and radiographic results of patients with syndesmotic screw fixation: implications for screw removal.

    abstract:OBJECTIVE:Screw fixation of the injured syndesmosis restores stability but may reduce motion. The purpose of this study is to determine whether functional outcomes and radiographic results after ankle fracture are affected by the status of the syndesmosis screw. DESIGN:Retrospective review of a consecutive clinical se...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181a9f7a5

    authors: Manjoo A,Sanders DW,Tieszer C,MacLeod MD

    更新日期:2010-01-01 00:00:00

  • The two-step maneuver for closed reduction of inferior glenohumeral dislocation (luxatio erecta to anterior dislocation to reduction).

    abstract::The 2-step closed reduction maneuver was developed to aid in the rarely encountered inferior shoulder dislocation. The maneuver converts the humeral head from an inferior dislocation to an anterior dislocation and then reduces the humeral head into the glenoid. The operator places one hand on the shaft of the humerus ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200605000-00010

    authors: Nho SJ,Dodson CC,Bardzik KF,Brophy RH,Domb BG,MacGillivray JD

    更新日期:2006-05-01 00:00:00

  • Segmental Tibia Fractures: An Analysis of Complication and Healing Rates.

    abstract:OBJECTIVES:To determine the most commonly associated injuries, complications, and healing rates of patients sustaining segmental tibial shaft fractures. DESIGN:Retrospective review. SETTING:Two Level I trauma centers. PATIENTS:A total of 108 patients with segmental tibial shaft fractures were identified between 2005...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001132

    authors: Corey RM,Park NK,Cannada LK

    更新日期:2018-06-01 00:00:00

  • Arachidonic acid, eicosanoids, and fracture repair.

    abstract::Not all fractures heal well or rapidly in the adult skeleton, and basic scientists and clinicians continue to search for ways to make fractures heal more predictably. It is a fundamental tenet of orthopaedics that skeletal injury is followed by inflammation and that this inflammatory response is the first stage in a s...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e3181f17b33

    authors: Wixted JJ,Fanning P,Rothkopf I,Stein G,Lian J

    更新日期:2010-09-01 00:00:00

  • Treatment of Gartland type III pediatric supracondylar humerus fractures with the Kapandji technique in the prone position.

    abstract:OBJECTIVE:The purpose of this study was to report the efficacy of the Kapandji technique performed in the prone position for humeral supracondylar fractures in children. DESIGN:Retrospective. SETTING:Level I trauma center. PATIENTS/PARTICIPANTS:We retrospectively reviewed 34 children with Gartland type III supracond...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000015

    authors: Kao HK,Yang WE,Li WC,Chang CH

    更新日期:2014-06-01 00:00:00

  • Inflammation, Bone Healing, and Anti-Inflammatory Drugs: An Update.

    abstract::Fracture healing is a unique multifaceted process requiring the presence of cells, molecular mediators, and angiogenic factors. The state of inflammation dominates the initial phase, but the ideal magnitude and duration of the process for an optimal outcome remains obscure. Biological response modifiers, such as plate...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000465

    authors: Giannoudis PV,Hak D,Sanders D,Donohoe E,Tosounidis T,Bahney C

    更新日期:2015-12-01 00:00:00

  • Use of the Medoff sliding plate for subtrochanteric hip fractures.

    abstract:OBJECTIVE:To evaluate the effects of dynamization of a sliding hip screw plate on the fixation stability for several types of subtrochanteric fractures. Clinical results of treating reverse oblique fractures occasionally show medialization of the femoral shaft. DESIGN:Two types of plate dynamization were compared usin...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199704000-00007

    authors: Kummer FJ,Pearlman CA,Koval KJ,Ceder L

    更新日期:1997-04-01 00:00:00

  • Indications and Clinical Results of Radial Head Replacement: Has Anything Changed?

    abstract::Radial head fractures are common injuries comprising 1/3 of the fractures about the elbow. As a secondary valgus stabilizer of the elbow, radial head fractures can compromise elbow stability leading to long-term pain, dysfunction, and degenerative change. Furthermore, radial head fractures can be accompanied by associ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001641

    authors: Eyberg BA,McKee MD

    更新日期:2019-12-01 00:00:00

  • The use of a biodegradable, load-bearing scaffold as a carrier for antibiotics in an infected open fracture model.

    abstract:OBJECTIVES:Open fractures with bone loss are common, disabling injuries. Biodegradable, load-bearing scaffolds able to carry high concentrations of local antibiotics are an emerging technology to address these injuries. This study investigates the use of such scaffolds with gentamicin (along with bone morphogenetic pro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ed1349

    authors: Stewart RL,Cox JT,Volgas D,Stannard J,Duffy L,Waites KB,Chu TM

    更新日期:2010-09-01 00:00:00

  • The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures.

    abstract:OBJECTIVES:The purpose of this study was to evaluate forearm rotation after volar plating of the distal radius fractures with and without pronator quadratus repair. DESIGN:This was an institutional review board-approved retrospective review of prospectively collected data. SETTING:The study was conducted at an Academ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182539333

    authors: Hershman SH,Immerman I,Bechtel C,Lekic N,Paksima N,Egol KA

    更新日期:2013-03-01 00:00:00

  • Unexpected high complication rate following internal fixation of unstable proximal humerus fractures with an angled blade plate.

    abstract:OBJECTIVES:The increasing number of fractures of the proximal humerus, especially in the elderly, carries with it the unsolved problem of the optimal treatment for the displaced or unstable fractures. The authors' goal was to analyze whether fixation with a bent valgus angled blade plate could improve the outcomes repo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200604000-00004

    authors: Meier RA,Messmer P,Regazzoni P,Rothfischer W,Gross T

    更新日期:2006-04-01 00:00:00

  • Uncemented Reverse Total Shoulder Arthroplasty as Initial Treatment for Comminuted Proximal Humerus Fractures.

    abstract:OBJECTIVES:To determine whether uncemented implants would provide similar outcomes while avoiding the complications associated with cement in the treatment of elderly patients with proximal humerus fractures (PHFs) with primary reverse total shoulder arthroplasty (RTSA). DESIGN:Case series. SETTING:A single Level I t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001465

    authors: Wright JO,Ho A,Kalma J,Koueiter D,Esterle J,Marcantonio D,Wiater JM,Wiater B

    更新日期:2019-07-01 00:00:00

  • Irreducible fracture dislocation of the knee.

    abstract::A unique case of an irreducible fracture dislocation of the knee is reported. A review of the literature revealed no previously reported cases of fracture dislocation of the distal femur not amenable to closed reduction. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/00005131-199607000-00013

    authors: Pugh KJ,Wilber JH

    更新日期:1996-01-01 00:00:00

  • Treatment preferences for displaced three- and four-part proximal humerus fractures.

    abstract:OBJECTIVES:To assess the treatment preferences of orthopaedic surgeons for displaced three- and four-part proximal humerus fractures. DESIGN:Cross-sectional survey. SETTING:Academic and nonacademic institutions across Canada. PATIENTS/PARTICIPANTS:Members of the Canadian Orthopedic Trauma Society and the Joint Ortho...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181bdc46a

    authors: Guy P,Slobogean GP,McCormack RG

    更新日期:2010-04-01 00:00:00

  • Prognostic reliability of the Hawkins sign in fractures of the talus.

    abstract:OBJECTIVE:To determine the prognostic reliability, sensitivity, and specificity of the Hawkins sign. The Hawkins sign is a subchondral radiolucent band in the talar dome that is indicative of viability at 6 to 8 weeks after a talus fracture. It is visible in the anterior-posterior view, but seldom appears on lateral ra...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318148c665

    authors: Tezval M,Dumont C,Stürmer KM

    更新日期:2007-09-01 00:00:00

  • Can locking screws allow smaller, low-profile plates to achieve comparable stability to larger, standard plates?

    abstract:OBJECTIVE:The open reduction and internal fixation of radial shaft fractures and osteotomies with standard 3.5-mm plates can be complicated by tendon irritation, hardware prominence, and fracture through the screw holes. With the advent of locking plate technology, implant companies and some surgeons have recommended e...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181f8bf9b

    authors: Garrigues GE,Glisson RR,Garrigues NW,Richard MJ,Ruch DS

    更新日期:2011-06-01 00:00:00

  • Predictors of Unplanned Reoperation After Operative Treatment of Pelvic Ring Injuries.

    abstract:OBJECTIVES:To evaluate the incidence of unplanned reoperations after pelvic ring injuries and to develop a risk prediction model. DESIGN:Retrospective review. SETTING:Level I Trauma Center. PATIENTS:The medical records of 913 patients (644 male and 269 female patients; mean age, 39 years; age range, 16-89 years) wit...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001170

    authors: Ochenjele G,Reid KR,Castillo RC,Schoonover CD,Montalvo RN,Manson TT,Sciadini MF,Nascone JW,Carlini AR,OʼToole RV

    更新日期:2018-07-01 00:00:00

  • Locking Screws With a Threaded Degradable Polymer Collar Reduce Construct Stiffness Over Time.

    abstract:OBJECTIVES:The stiffness of locking plates provide increased stability for early fracture healing but may limit late interfragmentary motion (IFM) necessary for secondary bone healing. An ideal plating construct would provide early rigidity and late flexibility to optimize bone healing. A novel screw plate construct ut...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001664

    authors: Schultz BJ,Amin NH,Mattison BJ,Mir HR,Shah AR,Cerynik DL

    更新日期:2020-03-01 00:00:00

  • Osteochondroma formation after a Salter II fracture.

    abstract::Osteochondromas are one of the most commonly observed benign bone tumors. Although there have been a number of experimental studies carried out to determine the origin of osteochondromas, their etiology remains a controversial issue. A well-documented case is presented in which a displaced Salter-Harris type II physea...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199410000-00013

    authors: Mintzer CM,Klein JD,Kasser JR

    更新日期:1994-10-01 00:00:00

  • Biomechanics of Ender rods, compression screw, and Zickel nail in the fixation of stable subtrochanteric femur osteotomies.

    abstract::Compression screws, Ender rods, and Zickel nails were evaluated mechanically to determine their resulting stability in the fixation of experimental subtrochanteric femur osteotomies. Twenty-five pairs of human cadaver femurs were used. Experimental osteotomies were created and a random member of each pair was fixed wi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199003000-00010

    authors: Wainer RA,Wright PH,Gilbert JA,Taylor DF

    更新日期:1990-01-01 00:00:00