Osteochondroma formation after a Salter II fracture.

Abstract:

:Osteochondromas are one of the most commonly observed benign bone tumors. Although there have been a number of experimental studies carried out to determine the origin of osteochondromas, their etiology remains a controversial issue. A well-documented case is presented in which a displaced Salter-Harris type II physeal fracture preceded the development of an osteochondroma.

journal_name

J Orthop Trauma

authors

Mintzer CM,Klein JD,Kasser JR

doi

10.1097/00005131-199410000-00013

subject

Has Abstract

pub_date

1994-10-01 00:00:00

pages

437-9

issue

5

eissn

0890-5339

issn

1531-2291

journal_volume

8

pub_type

杂志文章
  • Surgical exposure and fixation of displaced type IV, V, and VI glenoid fractures.

    abstract::Displaced intra-articular fractures of the glenoid are rare and frequently result from high-energy injuries. Types IV, V, and VI fractures have in common a fracture line which extends medially into the scapular body. These fracture patterns present unique challenges for surgical approaches and reduction and fixation s...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0b013e31817d5356

    authors: Nork SE,Barei DP,Gardner MJ,Schildhauer TA,Mayo KA,Benirschke SK

    更新日期:2008-08-01 00:00:00

  • Treatment of displaced, proximal, humeral, epiphyseal fractures with a two-prong splint.

    abstract::To evaluate the use of a two-prong splint for displaced, proximal, humerus, epiphyseal fractures, seven children with Neer-Horwitz Classification Type 3-4 fractures of the proximal humerus were retrospectively investigated. After closed reduction, fracture stabilization was accomplished with the use of a two-prong spl...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200309000-00007

    authors: Karatosun V,Unver B,Alici E,Serin E

    更新日期:2003-09-01 00:00:00

  • Operative fixation of acetabular fractures in the pregnant patient.

    abstract:OBJECTIVE:To describe in utero radiation exposures in pregnant patients undergoing acetabular fracture repair. DESIGN:Retrospective case series. SETTING:University-affiliated regional trauma center. PATIENT/PARTICIPANTS:Eight pregnant patients with acetabular fractures treated over a 6-year period. There were an add...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181847a42

    authors: Porter SE,Russell GV,Qin Z,Graves ML

    更新日期:2008-09-01 00:00:00

  • Far Cortical Locking Fixation of Distal Femur Fractures is Dominated by Shear at Clinically Relevant Bridge Spans.

    abstract:OBJECTIVES:Far cortical locking (FCL) constructs have been shown to increase axial interfragmentary displacement while limiting shear and have been specifically recommended in the treatment of distal femur fractures. However, there is no available data regarding their mechanical behavior within the range of bridge span...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001341

    authors: Habet N,Elkins J,Peindl R,Killen C,Lack WD

    更新日期:2019-02-01 00:00:00

  • Operating Room Supply Costs in Orthopaedic Trauma: Cost Containment Opportunities.

    abstract::In the current health care environment, cost containment is more important than ever. Most physicians currently are unaware of the cost of operating room supplies. A large amount of waste occurs secondary to lack of knowledge and absence of physician incentives for cost saving. Many of the decisions for supply use can...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000718

    authors: Gurnea TP,Frye WP,Althausen PL

    更新日期:2016-12-01 00:00:00

  • Use of Inlet-Obturator Oblique View (Leeds View) for Placement of Posterior Wall Screws in Acetabular Fracture Surgery.

    abstract::Posterior wall (PW) fractures are the most common fractures requiring surgical fixation in acetabular surgery. Extra-articular screw placement must be confirmed intraoperatively. Herein we describe the use of the inlet and obturator oblique view (the Leeds view) for screw placement in elementary PW and in associated b...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0000000000000724

    authors: Tosounidis TH,Giannoudis PV

    更新日期:2017-04-01 00:00:00

  • The trochanteric C-clamp for provisional pelvic stability.

    abstract::The application of a pelvic clamp for provisional stability of unstable pelvic fractures has been advocated in the orthopaedic literature. Although the technique has gained some supporters, problems with placement and associated complications have prevented widespread acceptance. We have modified the pelvic clamp (ACE...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/01.bot.0000175156.92743.db

    authors: Archdeacon MT,Hiratzka J

    更新日期:2006-01-01 00:00:00

  • Multiple Procedures in the Initial Surgical Setting: When Do the Benefits Outweigh the Risks in Patients With Multiple System Trauma?

    abstract:OBJECTIVES:To compare single versus multiple procedures in the same surgical setting. We hypothesized that complication rates would not be different and length of stay would be shorter in patients undergoing multiple procedures. DESIGN:Prospective, cohort. SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS:A total...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000556

    authors: Childs BR,Nahm NJ,Moore TA,Vallier HA

    更新日期:2016-08-01 00:00:00

  • Biomechanical effects of internal fixation of the distal tibiofibular syndesmotic joint: comparison of two fixation techniques.

    abstract::This biomechanical study compares two methods of internal fixation of the tibiofibular syndesmosis used in Weber type C malleolar fractures of the ankle. The transverse syndesmotic 3.5-mm screw was compared with two 1.5-mm Kirschner wires introduced obliquely across the distal tibiofibular syndesmosis. The influence o...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199406000-00006

    authors: Peter RE,Harrington RM,Henley MB,Tencer AF

    更新日期:1994-01-01 00:00:00

  • Radiographic fracture assessments: which ones can we reliably make?

    abstract:OBJECTIVE:To identify the fracture characteristics that can be reliably assessed by analysis of plain radiographs of tibial plateau fractures. DESIGN:Radiographic review study. PARTICIPANTS:Five orthopaedic traumatologists served as observers. INTERVENTION:Observers made assessments based on the radiographs of fifty...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200008000-00001

    authors: Martin J,Marsh JL,Nepola JV,Dirschl DR,Hurwitz S,DeCoster TA

    更新日期:2000-08-01 00:00:00

  • Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty.

    abstract:OBJECTIVE:New locked plate devices offer theoretical advantages for the treatment of supracondylar femur fractures associated with a total knee arthroplasty (TKA). These devices also can be inserted with relative ease by using minimally invasive techniques, provide a fixed angle construct, and improve fixation in osteo...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200603000-00005

    authors: Ricci WM,Loftus T,Cox C,Borrelli J

    更新日期:2006-03-01 00:00:00

  • The realities of relationship failure.

    abstract::Young surgeons and their spouses experience a myriad of stresses in the first few years of practice. Issues related to job search, moving to a new community, learning one's craft, time management, changes to spouse's career, child rearing, and the ever blurring line between work time and free time may all contribute t...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182641fd8

    authors: Dunbar RP Jr

    更新日期:2012-09-01 00:00:00

  • Scapulothoracic dissociation with acromioclavicular separation: a case report of a novel fixation method.

    abstract::We present a case of 39-year-old female with a scapulothoracic dissociation and acromioclavicular (AC) separation and who had fixation of the AC joint with a locking plate, coracoclavicular screw, and transarticular AC screw. The coracoclavicular and AC relationships were maintained during postoperative rehabilitation...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181831352

    authors: Merk BR,Minihane KP,Shah NA

    更新日期:2008-09-01 00:00:00

  • Osteogenic protein-1 induces bone formation in the presence of bacterial infection in a rat intramuscular osteoinduction model.

    abstract:OBJECTIVE:Evaluate the ability of osteogenic protein-1 to induce formation of de novo bone in the presence of bacterial infection and metal in an intramuscular osteoinduction model in the rat. DESIGN:Prospective experimental design with assessment time points of up to 4 weeks. SETTING:Intramuscular pocket surgically ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200408000-00008

    authors: Chen X,Kidder LS,Schmidt AH,Lew WD

    更新日期:2004-08-01 00:00:00

  • Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures.

    abstract:OBJECTIVE:Comparison between a Less Invasive Stabilization System (LISS) using monocortical screws with angular stability and two conventional plate systems Condylar Buttress Plate (CBP) and Dynamic Condylar Screw (DCS) for the treatment of distal femoral fractures with respect to biomechanical properties. DESIGN:Biom...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200109000-00004

    authors: Marti A,Fankhauser C,Frenk A,Cordey J,Gasser B

    更新日期:2001-09-01 00:00:00

  • Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.

    abstract:OBJECTIVES:To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. DESIGN:Retrospective. SETTING:Urban University Level I Trauma Center. PATIENT/PARTICIPANTS:All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were re...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000391

    authors: Tank JC,Schneider PS,Davis E,Galpin M,Prasarn ML,Choo AM,Munz JW,Achor TS,Kellam JF,Gary JL

    更新日期:2016-01-01 00:00:00

  • Hexapod Frame Stacked Transport for Tibial Infected Nonunions With Bone Loss: Analysis of Use of Adjunctive Stability.

    abstract:OBJECTIVES:The stacked hexapod bone transport technique is an effective treatment for infected tibial nonunions with bone loss. The purpose of this study was to evaluate the patients' risk factors and timing for requiring adjunctive stabilization. DESIGN:Retrospective cohort study. SETTING:Level 1 trauma center. PAT...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000840

    authors: Napora JK,Weinberg DS,Eagle BA,Kaufman BR,Sontich JK

    更新日期:2017-07-01 00:00:00

  • Biomechanical Assessment of Locking Plate Fixation of Comminuted Proximal Olecranon Fractures.

    abstract:OBJECTIVES:To determine if mean ultimate strength or failure mechanism differed between comminuted olecranon fractures created at the proximal 25% or 50% of the trochlear notch and fixed with precontoured posterior locking plates (PLPs). METHODS:Comminuted osteotomies were created in 10 matched pairs of cadaveric uppe...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001279

    authors: Fantry A,Sobel A,Capito N,Hodax JD,Pidgeon T,Koruprolu S,Rich R,Fava JL,Green A,Paxton S

    更新日期:2018-11-01 00:00:00

  • Acute Femoral Nailing and Ipsilateral Knee Spanning External Fixation: Improved Early Stability for Floating Knee Injuries Involving the Tibial Plateau.

    abstract::Ipsilateral femoral shaft and tibial plateau fractures, termed a "floating knee" are rare and challenging injuries. There is limited literature guiding the operative technique and the outcomes associated with these injuries. The author's preferred technique is early intramedullary of the femoral shaft fracture with kn...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001944

    authors: Brown JT,Bergin PF,Prather JW,DiPaolo D,Spitler CA

    更新日期:2020-09-01 00:00:00

  • A prospective clinical study of proximal humerus fractures treated with a locking proximal humerus plate.

    abstract:OBJECTIVES:The purpose of this prospective study was to evaluate the safety, efficacy, and functional outcome of the locked proximal humerus plate (LPHP) to treat proximal humerus fractures. DESIGN:Prospective clinical trial. SETTING:University orthopedic center. PATIENTS:Over a 25-month period, 64 consecutive patie...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0b013e3181d2d04c

    authors: Yang H,Li Z,Zhou F,Wang D,Zhong B

    更新日期:2011-01-01 00:00:00

  • A new technique for creating an abdominal window in a hip spica cast.

    abstract::Opening an abdominal window in a hip spica type of cast can be a troubling maneuver for both orthopaedic surgeon and patient. We present a simple device to create an abdominal window more easily. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200307000-00009

    authors: Kiter E,Demirkan F,Kiliç BA,Erkula G

    更新日期:2003-07-01 00:00:00

  • No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures.

    abstract:OBJECTIVE:To determine whether stimulation with low-intensity ultrasound will reduce the radiologic healing time of fresh tibial shaft fractures fixed with a reamed and statically locked intramedullary rod. DESIGN:Prospective, randomized, double blinded, and placebo controlled. PATIENTS AND METHODS:Thirty-two adult p...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00005131-199905000-00005

    authors: Emami A,Petrén-Mallmin M,Larsson S

    更新日期:1999-05-01 00:00:00

  • The Effectiveness of Negative Pressure Wound Therapy Versus Conventional Dressing in the Treatment of Open Fractures: A Systematic Review and Meta-Analysis.

    abstract:OBJECTIVES:To compare the efficacy of negative pressure wound therapy (NPWT) versus conventional dressings (CD) in the management of open fractures. DATA SOURCES:A systematic search of English articles in the PubMed/MEDLINE, Embase, and the Cochrane Library through April 2019 comparing NPWT versus CD in the management...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001750

    authors: Grant-Freemantle MC,Ryan ÉJ,Flynn SO,Moloney DP,Kelly MA,Coveney EI,OʼDaly BJ,Quinlan JF

    更新日期:2020-05-01 00:00:00

  • Nonunion of capital femoral physeal fracture with a large metaphyseal fragment.

    abstract::This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181c83a3b

    authors: Yukata K,Kubo T,Matsui Y,Koizumi T,Takata S,Yasui N

    更新日期:2010-08-01 00:00:00

  • Intrawound Antibiotic Powder in Acetabular Fracture Open Reduction Internal Fixation Does Not Reduce Surgical Site Infections.

    abstract:OBJECTIVES:To compare the risks of surgical site infection (SSI) and postoperative complications after acetabular fracture open reduction internal fixation (ORIF) in patients receiving topical intrawound antibiotic powder compared to those not receiving antibiotic powder (control group). DESIGN:Retrospective cohort SE...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001943

    authors: Cichos KH,Spitler CA,Quade JH,Ponce BA,McGwin G Jr,Ghanem ES

    更新日期:2020-09-02 00:00:00

  • Biomechanical evaluation of two-part surgical neck fractures of the humerus fixed by an angular stable locked intramedullary nail.

    abstract:OBJECTIVE:The aim of the current study was to see how different interlocking mechanisms would affect construct stability and overall failure in the treatment of two-part surgical neck fractures in the proximal humerus in vitro. METHODS:Left and right bones of eight pairs of fresh-frozen human cadaveric humeri were ass...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ffdf9a

    authors: Horn J,Gueorguiev B,Brianza S,Steen H,Schwieger K

    更新日期:2011-07-01 00:00:00

  • Fractures in Patients With COVID-19 Infection: Early Prognosis and Management. A Case Series of 20 Patients in a Single Institution in Lombardy, Northern Italy.

    abstract::Fifty-eight percent of the total infections in Italy of COVID-19 were found in northern Italy, in particular, Lombardy. From February 21, 2020, to March 23, 2020, 20 patients with a fracture and a diagnosis of COVID-19 were hospitalized. Demographic data, COVID-19 symptoms, laboratory and radiographic examinations, an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001905

    authors: Jannelli E,Castelli A,Ferranti Calderoni E,Annunziata S,Maccario G,Ivone A,Pasta G,Mosconi M

    更新日期:2020-10-01 00:00:00

  • Split-Depressed Lateral Tibial Plateau Fractures: A Comparison of Augmented Percutaneous Screws Versus Augmented Plate and Screw Construct in a Cadaveric Model.

    abstract:OBJECTIVES:To compare the strength of fixation of percutaneous screw versus plate/screw fixation in a paired cadaver model of OTA 41-B3 (Schatzker type II) split-depression fractures of the lateral tibial plateau. METHODS:Six matched pairs of cadaveric knees were acquired. An OTA 41-B3 (Schatzker type II) split-depres...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001177

    authors: Bowles RJ,Chadayammuri V,Baldini T,Brecevich A,Mauffrey C

    更新日期:2018-07-01 00:00:00

  • Bundled Care for Hip Fractures: A Machine-Learning Approach to an Untenable Patient-Specific Payment Model.

    abstract:OBJECTIVES:With the transition to a value-based model of care delivery, bundled payment models have been implemented with demonstrated success in elective lower extremity joint arthroplasty. Yet, hip fracture outcomes are dependent on patient-level factors that may not be optimized preoperatively due to acuity of care....

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001454

    authors: Karnuta JM,Navarro SM,Haeberle HS,Billow DG,Krebs VE,Ramkumar PN

    更新日期:2019-07-01 00:00:00

  • Triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing.

    abstract:OBJECTIVE:Presentation of a new triangular osteosynthesis technique that permits early weight-bearing in vertically unstable sacral fractures. DESIGN:Retrospective evaluation of a consecutive series. SETTING:Level I trauma center. PATIENTS:Thirty-four patients, twenty-eight of whom were polytraumatized, all with ver...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199806000-00002

    authors: Schildhauer TA,Josten C,Muhr G

    更新日期:1998-06-01 00:00:00