Needle localization of occult breast lesions with a curved-end retractable wire: technique and pitfalls.

Abstract:

:A series of 100 consecutive occult mammographic abnormalities were localized with a curved-end retractable wire system. A true-positive rate of 24% and a failure rate of 4% for initial excision were found. The pitfalls and advantages of this new needle-wire breast localizer are presented.

journal_name

Radiology

journal_title

Radiology

authors

Homer MJ,Pile-Spellman ER

doi

10.1148/radiology.161.2.3763930

subject

Has Abstract

pub_date

1986-11-01 00:00:00

pages

547-8

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

161

pub_type

杂志文章
  • Sector computed tomographic spine scanning in the diagnosis of lumbar nerve root entrapment.

    abstract::The diagnosis of lumbar nerve root entrapment was made by sector computed tomography (CT) scanning in 25 patients whose myelograms were normal at the site of the CT scan abnormalities. Sector CT scanning demonstrates preoperatively which neural foramina are narrow. This information, correlated with the patient's histo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.143.1.7063710

    authors: Risius B,Modic MT,Hardy RW Jr,Duchesneau PM,Weinstein MA

    更新日期:1982-04-01 00:00:00

  • Polyclonal human immunoglobulin G labeled with polymeric iron oxide: antibody MR imaging.

    abstract::Human polyclonal immunoglobulin (Ig) G was attached to a monocrystalline iron oxide nanocompound (MION), a small superparamagnetic probe developed for receptor and antibody magnetic resonance (MR) imaging. The resulting complex, MION-IgG, had a slightly negative surface charge, a molecular weight of 150-180 kDa, and 0...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.181.1.1887040

    authors: Weissleder R,Lee AS,Fischman AJ,Reimer P,Shen T,Wilkinson R,Callahan RJ,Brady TJ

    更新日期:1991-10-01 00:00:00

  • Multiphasic examinations of the stomach: efficacy of individual techniques and combinations of techniques in detecting 153 lesions.

    abstract::Multiphasic examinations of 153 gastric abnormalities observed radiologically and endoscopically were reviewed to determine the efficacy of four radiologic techniques and of several common combinations of these techniques for examining the stomach. There were 68 gastric ulcers, 12 ulcer scars, 44 cases of gastritis in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.162.3.3809500

    authors: Gelfand DW,Chen YM,Ott DJ

    更新日期:1987-03-01 00:00:00

  • Percutaneous image-guided cutting-needle biopsy of the pleura in the presence of a suspected malignant effusion.

    abstract:PURPOSE:To evaluate the diagnostic accuracy of percutaneous image-guided cutting-needle biopsy of pleural thickening in the presence of a suspected malignant pleural effusion. MATERIALS AND METHODS:Thirty-three adult patients with diffuse or focal pleural thickening (median, 1.0 cm; range, 0.2-6.0 cm), pleural effusio...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.219.2.r01ma07510

    authors: Adams RF,Gleeson FV

    更新日期:2001-05-01 00:00:00

  • Effects of some water-soluble contrast media on the colonic mucosa.

    abstract::Enemas of various solutions were administered to rats to determine if Gastrografin was specifically irritating to the colonic mucosa. Gastrografin was found to cause considerably more inflammation than Hypaque-25, or barium sulfate. Further studies with hypertonic sorbitol, Renografin-76, and Tween 80 suggested that (...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.3.545

    authors: Lutzger LG,Factor SM

    更新日期:1976-03-01 00:00:00

  • Dilated abdominal paraaortic lymphatic duct: a possible pitfall in retroperitoneal US.

    abstract::Three cases of dilated abdominal left paraaortic lymphatic duct are described. The diagnosis was established by means of sonography and confirmed with lymphography in all three patients. A sonographically guided puncture of the lymphatic duct was performed in one patient. Dilatation of these lymphatic ducts was possib...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.3.3283840

    authors: Verbanck JJ,Vermeulen JT,Rutgeerts LJ,Depuyt FG,Ghillebert GL,Segaert MF,Naesens MH

    更新日期:1988-06-01 00:00:00

  • Desmoplastic small round cell tumor of the abdomen: radiologic-histopathologic correlation.

    abstract:PURPOSE:To characterize the imaging features of desmoplastic small round cell tumor of the abdomen and correlate them with the histopathologic findings. MATERIALS AND METHODS:Eleven of 14 patients with desmoplastic small round cell tumor had primary abdominal involvement. In nine of these patients (mean age, 20 years)...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.210.3.r99mr42633

    authors: Pickhardt PJ,Fisher AJ,Balfe DM,Dehner LP,Huettner PC

    更新日期:1999-03-01 00:00:00

  • Ultrasound mammography for the augmented breast.

    abstract::Ultrasound examinations were performed on 25 women with augmented breasts using whole-breast water-path scanning. In these patients, ultrasound imaged carcinoma, benign lesions, and fibrous capsule formation; these were confirmed by surgery. In addition, it was noted that certain prostheses appeared to be displaced po...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.146.3.6828690

    authors: Cole-Beuglet C,Schwartz G,Kurtz AB,Patchefsky AS,Goldberg BB

    更新日期:1983-03-01 00:00:00

  • Using computed tomography of the brain to correlate low white-matter attenuation with early gestational age in neonates.

    abstract::Computed tomographic brain scans of the newborn exhibit relatively greater lucency of white matter compared to the mature patient. This study correlated the x-ray attenuation of white matter with gestational age in 23 neonates, both premature and term. The gray-white matter attenuation difference was calculated and pl...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.139.1.7208910

    authors: Brant-Zawadzki M,Enzmann DR

    更新日期:1981-04-01 00:00:00

  • Liver size evaluated by ultrasound: ROC curves for hepatitis and alcoholism.

    abstract::A previous study determined the normal values and upper limits of liver size, as measured by the longitudinal and sagittal diameters in the midclavicular line and the midline. The present study was performed to determine which of the four sonographic diameters best differentiates between patients who have liver diseas...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.153.2.6385110

    authors: Niederau C,Sonnenberg A

    更新日期:1984-11-01 00:00:00

  • Hyperparathyroidism: comparison of MR imaging with radionuclide scanning.

    abstract::Twenty-three patients with hyperparathyroidism were evaluated preoperatively with magnetic resonance (MR) imaging. Twenty patients also underwent thallium-201/technetium-99m scintigraphy. Of 22 patients with primary hyperparathyroidism, 12 had persistent or recurrent disease. One had secondary hyperparathyroidism due ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.2.3562820

    authors: Peck WW,Higgins CB,Fisher MR,Ling M,Okerlund MD,Clark OH

    更新日期:1987-05-01 00:00:00

  • Computed tomographic brain scanning in patients with lymphoma.

    abstract::A retrospective study of 118 lymphoma patients revealed the computed tomographic brain scan to be sensitive to involvement of the orbit and the brain parenchyma by lymphoma. Brain parenchymal lymphoma was seen only in diffuse histiocytic lymphoma; dural infiltration was less readily detected. Leptomeningeal lymphoma c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.1.67

    authors: Brant-Zawadzki M,Enzmann DR

    更新日期:1978-10-01 00:00:00

  • Clinical and radiographic manifestations of aortoesophageal fistulas.

    abstract::Aneurysms of the thoracic aorta simulated primary esophageal disease both clinically and radiographically in 5 patients. Four had an aortoesophageal fistula at the time of presentation; endoscopic biopsy of a presumed esophageal tumor precipitated hematemesis in the fifth patient. In retrospect, the fistulas were demo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.141.3.7302210

    authors: Baron RL,Koehler RE,Gutierrez FR,Forrest JV,Weyman PJ

    更新日期:1981-12-01 00:00:00

  • Patient exposure and associated radiation risks from fluoroscopically guided vertebroplasty or kyphoplasty.

    abstract:PURPOSE:To derive normalized data for the estimation of effective, gonadal, and peak skin doses to patients undergoing vertebroplasty or kyphoplasty and to investigate the potential for cancer induction, genetic effects, and radiation-induced skin injury after such procedures. MATERIALS AND METHODS:Dose values normali...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2323031412

    authors: Perisinakis K,Damilakis J,Theocharopoulos N,Papadokostakis G,Hadjipavlou A,Gourtsoyiannis N

    更新日期:2004-09-01 00:00:00

  • Arthropathy in Behçet disease: MR imaging findings in two cases.

    abstract::Arthropathy is part of the protean manifestations of Behçet disease. Imaging findings reported thus far have been based on those of conventional radiography. Magnetic resonance imaging in two cases of Behçet disease with arthropathy demonstrated synovial thickening and effusion, as well as myositis manifested by high ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2262011982

    authors: Choi JA,Kim JE,Koh SH,Chung HW,Kang HS

    更新日期:2003-02-01 00:00:00

  • Computed tomography of angiographically occult cerebral vascular malformations.

    abstract::Although some cerebral vascular malformations are angiographically occult, the correct diagnosis may be suggested by their appearance on computed tomography (CT). The authors advise caution in assuming that angiographically avascular lesions which show contrast enhancement on CT represent neoplasms rather than vascula...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.3.649

    authors: Kramer RA,Wing SD

    更新日期:1977-06-01 00:00:00

  • Extravasation detection accessory: clinical evaluation in 500 patients.

    abstract:PURPOSE:To assess the ability of an extravasation detection accessory (EDA) to detect clinically important (> or = 10 mL) extravascular injection of iodinated contrast material delivered with an automated power injector. MATERIALS AND METHODS:Five hundred patients referred for contrast material-enhanced body computed ...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiology.212.2.r99au14431

    authors: Birnbaum BA,Nelson RC,Chezmar JL,Glick SN

    更新日期:1999-08-01 00:00:00

  • Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality.

    abstract:PURPOSE:To prospectively evaluate to what extent image quality in 16-detector row computed tomographic (CT) coronary angiography is a function of the heart rate and the image reconstruction technique used. MATERIALS AND METHODS:A total of 70 patients (49 men, 21 women; mean age, 59.1 years +/- 5.8 [standard deviation]...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2381041595

    authors: Herzog C,Arning-Erb M,Zangos S,Eichler K,Hammerstingl R,Dogan S,Ackermann H,Vogl TJ

    更新日期:2006-01-01 00:00:00

  • 99mTc-pertechnetate thyroid scintigraphy in patients predisposed to thyroid neoplasms by prior radiotherapy to the head and neck.

    abstract::Histories, physical examinations and 99mTc-pertechnetate imaging were used to evaluate 1,452 persons who had had x-ray therapy to the neck region for benign conditions 18 to 35 years previously. Thyroid abnormalities were found in 301 patients (21%) and thyroid malignancy was found in 29% of 193 patients with abnormal...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/15.3.653

    authors: Arnold J,Pinsky S,Ryo UY,Frohman L,Schneider A,Favus M,Stachura M,Arnold M,Colman M

    更新日期:1975-06-01 00:00:00

  • Urinary tract infections in children: renal ultrasound evaluation.

    abstract::Ultrasound may replace urography in screening pediatric patients with uncomplicated urinary tract infections but without vesicoureteral reflux. A child undergoing a first radiographic evaluation for urinary tract infection is initially examined by voiding cystourethrography. If reflux is present, urography is performe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.153.1.6473770

    authors: Mason WG Jr

    更新日期:1984-10-01 00:00:00

  • Adenomyosis: prospective comparison of MR imaging and transvaginal sonography.

    abstract:PURPOSE:To prospectively compare conventional spin-echo magnetic resonance (MR) imaging and transvaginal sonography for the diagnosis of adenomyosis. MATERIALS AND METHODS:Twenty women with clinically suspected adenomyosis underwent MR imaging and transvaginal sonography performed within 3 months of each other. Pathol...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.3.8115630

    authors: Ascher SM,Arnold LL,Patt RH,Schruefer JJ,Bagley AS,Semelka RC,Zeman RK,Simon JA

    更新日期:1994-03-01 00:00:00

  • Internal derangements and arthritis of the temporomandibular joint.

    abstract::Internal derangements of the temporomandibular joint (TMJ) may be a significant factor in the etiology of painful dysfunction of the jaw and associated clinical symptoms. In a two-year prospective investigation, 170 TMJs in 85 patients were studied with plain tomography prior to arthrotomography. Arthritis was detecte...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.146.1.6849030

    authors: Katzberg RW,Keith DA,Guralnick WC,Manzione JV Jr,Ten Eick WR

    更新日期:1983-01-01 00:00:00

  • Aneurysms of the right ventricular outflow tract after tetralogy of Fallot repair: role of radiology.

    abstract::Eight patients with aneurysms of the right ventricular outflow tract patch following tetralogy of Fallot repair were found to have residual distal obstructions. The site of such an obstruction must be carefully documented preoperatively because failure to relieve significant distal obstruction may result in recurrent ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.1.3347710

    authors: Ascuitto RJ,Ross-Ascuitto NT,Markowitz RI,Kopf GS,Hellenbrand WE,Fahey JT,Kleinman CS

    更新日期:1988-04-01 00:00:00

  • The relation of liver fat to computed tomography numbers: a preliminary experimental study in rabbits.

    abstract::The relation of liver fat content to CT number was studied in 20 rabbits (17 experimental, 3 control), where fatty degeneration was produced by carbon tetrachloride (CCl4) ingestion. Liver scanning was performed before and 2--5 days after CCl4 administration.. Changes (decrease) in CT number were compared with triglyc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/130.2.511

    authors: Ducommun JC,Goldberg HI,Korobkin M,Moss AA,Kressel HY

    更新日期:1979-02-01 00:00:00

  • Long-term Graft and Patient Survival after Percutaneous Angioplasty or Arterial Stent Placement for Transplant Renal Artery Stenosis: A 21-year Matched Cohort Study.

    abstract::Purpose To compare long-term graft and patient survival after percutaneous angioplasty (PTA) or stent placement for transplant renal artery stenosis (TRAS) with a control cohort without TRAS. Materials and Methods This is a retrospective matched cohort study of 41 patients (median age, 49 years; range, 18-72 years), i...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018181320

    authors: Patel U,Kumar S,Johnson OW,Jeon JH,Das R

    更新日期:2019-02-01 00:00:00

  • Hemodialysis catheter placement and management.

    abstract::Hemodialysis catheters are an integral part of the delivery of hemodialysis. While catheters play an important role in the patient undergoing hemodialysis, catheters should be considered a bridge to more permanent forms of dialysis access in most patients. Recent advances in catheter technology, access techniques, and...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.215.3.r00jn23651

    authors: Trerotola SO

    更新日期:2000-06-01 00:00:00

  • Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid.

    abstract::The authors discuss the appropriate FISP (fast imaging with steady-state precession) sequence structure to maintain constant phase at the radio-frequency pulse in the presence of motion. They present preliminary results of its application to head and spine imaging in an effort to maintain contrast between the cerebros...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.175.2.2326480

    authors: Haacke EM,Wielopolski PA,Tkach JA,Modic MT

    更新日期:1990-05-01 00:00:00

  • Value of Multiparametric US in the Assessment of Intratesticular Lesions.

    abstract::Purpose To evaluate the diagnostic accuracy of multiparametric ultrasonography (US) consisting of gray-scale US, color Doppler US, strain elastography, and contrast agent-enhanced US in the assessment of intratesticular lesions. Materials and Methods Institutional review board approval was obtained for this retrospect...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017161373

    authors: Auer T,De Zordo T,Dejaco C,Gruber L,Pichler R,Jaschke W,Dogra VS,Aigner F

    更新日期:2017-11-01 00:00:00

  • Dynamic pulmonary CT: findings in healthy adult men.

    abstract::The authors examined 10 healthy male subjects with dynamic computed tomography to determine normal dynamic and expiratory findings. In both the supine and prone positions, the average increase in lung attenuation during exhalation was found to be significantly greater in dependent lung regions than in nondependent lun...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.186.1.8416550

    authors: Webb WR,Stern EJ,Kanth N,Gamsu G

    更新日期:1993-01-01 00:00:00

  • Use of Wallstents for hemodialysis access-related venous stenoses and occlusions untreatable with balloon angioplasty.

    abstract:PURPOSE:To determine whether the Wallstent endoluminal prosthesis can be used to maintain patency of venous stenoses and occlusions related to hemodialysis access. MATERIALS AND METHODS:Wallstents were placed in 52 patients with 56 lesions. Thirty-two lesions were in central veins and 24 were in peripheral veins. Sten...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.2.7724770

    authors: Gray RJ,Horton KM,Dolmatch BL,Rundback JH,Anaise D,Aquino AO,Currier CB,Light JA,Sasaki TM

    更新日期:1995-05-01 00:00:00