Value of Multiparametric US in the Assessment of Intratesticular Lesions.

Abstract:

:Purpose To evaluate the diagnostic accuracy of multiparametric ultrasonography (US) consisting of gray-scale US, color Doppler US, strain elastography, and contrast agent-enhanced US in the assessment of intratesticular lesions. Materials and Methods Institutional review board approval was obtained for this retrospective study. From January 2012 to December 2015, 55 focal testicular lesions that were indeterminate on gray-scale US scans were further characterized with color Doppler US, strain elastography, and contrast-enhanced US. Strain elastography was performed to assess tissue elasticity, and hard lesions were defined as malignant. Color Doppler US and contrast-enhanced US were performed to determine the absence or presence of vascularization. Avascular lesions were defined as benign. Histopathologic results or follow-up examinations served as reference standards. Correct classification rate, sensitivity, specificity, and likelihood ratio were calculated. Results Of 55 testicular lesions, 43 (78.2%) were benign and 12 (21.8%) were malignant. Single-modality sensitivities and specificities were 66.7% and 88.4% for color Doppler US, 100% and 76.7% for contrast-enhanced US, and 100% and 72.1% for strain elastography, respectively. Among 12 malignant lesions, color Doppler US failed to demonstrate vascularization in four (33.3%) lesions, which were positive for cancer at contrast-enhanced US. By combining strain elastography and contrast-enhanced US, a sensitivity of 100% and specificity of 93.0% were achieved in differentiating benign and malignant focal testicular lesions. Positive likelihood ratio was 5.7 for color Doppler US, 4.3 for contrast-enhanced US, 3.6 for strain elastography, 14.3 for strain elastography combined with color Doppler US, and 14.3 for strain elastography combined with contrast-enhanced US. Conclusion Multiparametric US allows for a reliable differentiation of benign and malignant intratesticular lesions and can potentially be useful in deciding whether orchiectomy can be replaced with follow-up or less invasive organ-sparing strategies. © RSNA, 2017.

journal_name

Radiology

journal_title

Radiology

authors

Auer T,De Zordo T,Dejaco C,Gruber L,Pichler R,Jaschke W,Dogra VS,Aigner F

doi

10.1148/radiol.2017161373

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

640-649

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

285

pub_type

杂志文章
  • Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists' detection performance.

    abstract:PURPOSE:To evaluate the effect of computer-aided diagnosis (CAD) on radiologists' detection of pulmonary nodules. MATERIALS AND METHODS:Fifty chest computed tomographic (CT) examination cases were used. The mean nodule size was 0.81 cm +/- 0.60 (SD) (range, 0.3-2.9 cm). Alternative free-response receiver operating cha...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2302030049

    authors: Awai K,Murao K,Ozawa A,Komi M,Hayakawa H,Hori S,Nishimura Y

    更新日期:2004-02-01 00:00:00

  • MR coronary angiography and late-enhancement myocardial MR in children who underwent arterial switch surgery for transposition of great arteries.

    abstract:PURPOSE:To prospectively evaluate the feasibility of magnetic resonance (MR) coronary artery imaging and to define myocardial damage with late-enhancement myocardial MR imaging in children who underwent arterial switch surgery for transposition of the great arteries. MATERIALS AND METHODS:The local research ethics com...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2342032059

    authors: Taylor AM,Dymarkowski S,Hamaekers P,Razavi R,Gewillig M,Mertens L,Bogaert J

    更新日期:2005-02-01 00:00:00

  • Clinical significance of 99mtechnetium sulfur colloid accumulation in renal transplant patients.

    abstract::The accumulation of 99mtechnetium sulfur colloid (99mTcSC) was evaluated in 47 studies performed on 19 renal transplant patients by comparing its transplant activity to its bone marrow accumulation. There was a diagnosis of rejection of 21 of 22 studies (96.5%) in which marked transplant accumulation was noted. In 11 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.3.745

    authors: Kim YC,Massari PU,Brown ML,Thrall JH,Chang B,Keyes JW Jr

    更新日期:1977-09-01 00:00:00

  • Calculation of T2 values versus phase imaging for the distinction between flow and thrombus in MR imaging.

    abstract::In magnetic resonance (MR) imaging the distinction between vascular signal from flowing blood and thrombus of any nature is often difficult. Even though there are qualitative criteria to identify intravascular signal as coming from flowing blood, these can fail, and no definitive statement can be made on the nature of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.2.3602400

    authors: von Schulthess GK,Augustiny N

    更新日期:1987-08-01 00:00:00

  • Cancer of the glottis: prognostic factors in radiation therapy.

    abstract::The authors conducted a multivariate analysis of the prognostic factors in 96 patients with early glottic cancer treated by radiation therapy. Of these, 73 had T1 and 23 had T2 tumor. The primary tumor was controlled in 82% of T1 and 74% of T2 lesions. Actuarial five-year survival rates were 87% for T1 and 74% for T2....

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6611940

    authors: Mantravadi RV,Liebner EJ,Haas RE,Skolnik EM,Applebaum EL

    更新日期:1983-10-01 00:00:00

  • Catheter visualization with resonant markers at MR imaging-guided deployment of endovascular stents in swine.

    abstract:PURPOSE:To evaluate resonant circuits as markers for magnetic resonance (MR) imaging-guided placement of nitinol stents. MATERIALS AND METHODS:The study was approved by the institutional animal research committee and complied with National Institutes of Health guidelines for care and use of laboratory animals. Resonan...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2333031710

    authors: Kuehne T,Weiss S,Brinkert F,Weil J,Yilmaz S,Schmitt B,Ewert P,Lange P,Gutberlet M

    更新日期:2004-12-01 00:00:00

  • Retinoblastoma: MR imaging parameters in detection of tumor extent.

    abstract:PURPOSE:To assess diagnostic accuracy of preoperatively performed magnetic resonance (MR) imaging for detection of tumor extent in a large patient population with histopathologically proved retinoblastoma. MATERIALS AND METHODS:Local ethics committee approval and informed consent were not required for retrospective re...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2351031301

    authors: de Graaf P,Barkhof F,Moll AC,Imhof SM,Knol DL,van der Valk P,Castelijns JA

    更新日期:2005-04-01 00:00:00

  • Trends in use of barium enema examination, colonoscopy, and sigmoidoscopy: is use commensurate with risk of disease?

    abstract:PURPOSE:To assess replacement of barium enema examination with colonoscopy in relation to age- and sex-related risk factors, place of service, physician specialty, and cost. MATERIALS AND METHODS:Between 1985 and 1992, 894,777 insurance claims for barium enema examination and lower gastrointestinal endoscopy were retr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.3.7754010

    authors: Karasick S,Ehrlich SM,Levin DC,Harford RJ,Rosetti EF,Ricci JA,Beam LM,Gigliotti JV

    更新日期:1995-06-01 00:00:00

  • Normal and acutely torn posterior cruciate ligament of the knee at US evaluation: preliminary experience.

    abstract:PURPOSE:To determine the ultrasonographic (US) findings of normal and acutely torn posterior cruciate ligament (PCL) of the knee and evaluate the usefulness of US in the injured PCL. MATERIALS AND METHODS:US images were obtained in 30 knees in 15 asymptomatic volunteers as a control group and in 35 patients clinically...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.219.2.r01ma22375

    authors: Cho KH,Lee DC,Chhem RK,Kim SD,Bouffard JA,Cardinal E,Park BH

    更新日期:2001-05-01 00:00:00

  • Assessment of arterial blood flow measurements by digital angiography.

    abstract::A system for computerized processing of video image series was utilized for the real-time digitization of arteriograms. There were 256 x 256 picture elements (pixels) per image with a resolution of 256 gray levels. Temporal changes in x-ray absorption at each pixel as induced by contrast media were computed for the ex...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.141.1.7291540

    authors: Bürsch JH,Hahne HJ,Brennecke R,Grönemeier D,Heintzen PH

    更新日期:1981-10-01 00:00:00

  • Rotator cuff disruption: diagnosis with digital arthrography.

    abstract::Shoulder arthrography is a reliable technique for use in the diagnosis of tears of the rotator cuff, although delineation of the precise site and size of tears requires meticulous double-contrast technique and considerable examiner expertise. The authors initiated a prospective evaluation of digital arthrography of th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.3.3406400

    authors: Stiles RG,Resnick D,Sartoris DJ,Andre MP

    更新日期:1988-09-01 00:00:00

  • Digital Compared with Screen-Film Mammography: Measures of Diagnostic Accuracy among Women Screened in the Ontario Breast Screening Program.

    abstract:PURPOSE:To compare measures of diagnostic accuracy between large concurrent cohorts of women screened with digital computed radiography (CR), direct radiography (DR), and screen-film mammography (SFM). MATERIALS AND METHODS:This study was approved by the University of Toronto Research Ethics Board; informed consent wa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150733

    authors: Prummel MV,Muradali D,Shumak R,Majpruz V,Brown P,Jiang H,Done SJ,Yaffe MJ,Chiarelli AM

    更新日期:2016-02-01 00:00:00

  • White Matter by Diffusion MRI Following Methylphenidate Treatment: A Randomized Control Trial in Males with Attention-Deficit/Hyperactivity Disorder.

    abstract::BackgroundMethylphenidate (MPH) is highly effective in treating attention-deficit/hyperactivity disorder (ADHD). However, not much is known about its effect on the development of human brain white matter (WM).PurposeTo determine whether MPH modulates WM microstructure in an age-dependent fashion in a randomized double...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2019182528

    authors: Bouziane C,Filatova OG,Schrantee A,Caan MWA,Vos FM,Reneman L

    更新日期:2019-10-01 00:00:00

  • Osteoid osteoma: CT-guided percutaneous excision confirmed with immediate follow-up scintigraphy in 16 outpatients.

    abstract:PURPOSE:To evaluate treatment of osteoid osteoma with computed tomography (CT)-guided percutaneous excision and immediate follow-up scintigraphy. MATERIALS AND METHODS:Sixteen consecutive adolescent and adult patients underwent CT-guided percutaneous excision of a nidus with 14-gauge biopsy cutting needles, with local...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.201.1.8816550

    authors: Roger B,Bellin MF,Wioland M,Grenier P

    更新日期:1996-10-01 00:00:00

  • Optimal scan parameters for CT fluoroscopy in lung interventional radiologic procedures: relationship between radiation dose and image quality.

    abstract:PURPOSE:To evaluate the relationship between radiation doses and lung computed tomographic (CT) fluoroscopic scan parameters and to determine optimal scan parameters for performance of lung interventional radiologic (IR) procedures. MATERIALS AND METHODS:The institutional review board approved this prospective study, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.09090733

    authors: Yamao Y,Yamakado K,Takaki H,Yamada T,Murashima S,Uraki J,Kodama H,Nagasawa N,Takeda K

    更新日期:2010-04-01 00:00:00

  • Percutaneous intentional extraluminal recanalization in patients with chronic critical limb ischemia.

    abstract:PURPOSE:To review percutaneous intentional extraluminal recanalization (PIER) for treatment of patients who are poor candidates for infrainguinal arterial bypass surgery (IABS) and have arterial occlusions and chronic critical limb ischemia (CCLI). MATERIALS AND METHODS:Patients with CCLI who were poor candidates for ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2322030729

    authors: Spinosa DJ,Leung DA,Matsumoto AH,Bissonette EA,Cage D,Harthun NL,Kern JA,Angle JF,Hagspiel KD,Crosby IK,Wellons HA Jr,Tribble CG,Hartwell GD

    更新日期:2004-08-01 00:00:00

  • Thyroid Imaging Reporting and Data System (TI-RADS): A User's Guide.

    abstract::In 2017, the Thyroid Imaging Reporting and Data System (TI-RADS) Committee of the American College of Radiology (ACR) published a white paper that presented a new risk-stratification system for classifying thyroid nodules on the basis of their appearance at ultrasonography (US). In ACR TI-RADS, points in five feature ...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2017171240

    authors: Tessler FN,Middleton WD,Grant EG

    更新日期:2018-04-01 00:00:00

  • Doppler US. Part II. Clinical applications.

    abstract::Duplex and color Doppler ultrasound (US) are noninvasive techniques capable of providing much information about the condition of blood vessels and flow within them throughout the body. Doppler US provides more than noninvasive angiography. Besides assessment of blood vessel patency and direction of flow, analysis of t...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.174.2.2404310

    authors: Scoutt LM,Zawin ML,Taylor KJ

    更新日期:1990-02-01 00:00:00

  • Arteriography with portable DSA equipment.

    abstract::Fifty-one arteriograms were obtained outside of the radiology department with portable digital subtraction angiographic equipment. Thirty-five studies were performed in the emergency room, 12 in the operating room, and four in the intensive care unit. There was a significant decrease in the time interval from arrival ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/172.3.1023

    authors: King JN,Orrison WW,Keck GM,Demarest GB,Hinson JE,Sell JJ

    更新日期:1989-09-01 00:00:00

  • Roentgenography of congenital dislocation of the hip.

    abstract::The chronically dislocated hip of a 15-month-old girl was studied postmortem. The cartilaginous components of the pelvis (both true and false acetabula) and proximal femur were demonstrated roentgenographically and correlated with gross anatomical observations. These findings should be useful in the interpretation of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/119.1.189

    authors: Ogden JA,Jensen PS

    更新日期:1976-04-01 00:00:00

  • Colorectal tumor vascularity: quantitative assessment with multidetector CT--do tumor perfusion measurements reflect angiogenesis?

    abstract:PURPOSE:To establish the relationships between quantitative perfusion computed tomography (CT) parameters-specifically, primary tumor blood flow, blood volume, transit time, and permeability surface-area product-and immunohistologic markers of angiogenesis in colorectal cancer. MATERIALS AND METHODS:After institutiona...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2492071365

    authors: Goh V,Halligan S,Daley F,Wellsted DM,Guenther T,Bartram CI

    更新日期:2008-11-01 00:00:00

  • Magnetization transfer contrast-prepared MR imaging of the liver: inability to distinguish healthy from cirrhotic liver.

    abstract:PURPOSE:To evaluate the ability of magnetization transfer (MT) contrast-prepared magnetic resonance (MR) imaging to help distinguish healthy from cirrhotic liver by using a spectrum of MT pulse frequency offsets. MATERIALS AND METHODS:This HIPAA-compliant prospective study was approved by the institutional review boar...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11111043

    authors: Rosenkrantz AB,Storey P,Gilet AG,Niver BE,Babb JS,Hajdu CH,Lee VS

    更新日期:2012-01-01 00:00:00

  • A new radiological technique in evaluation of prosthetic fitting.

    abstract::Xeroradiography is an excellent technique in evaluating the fit of extremity prostheses. Because of its inherent characteristics, xeroradiography can clearly demonstrate the stump-socket relationship. Consequently, the degree of contact achieved and attendant pressure problems, if any, can be precisely determined. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.2.534

    authors: Jing BS,Villanueva R,Dodd GD

    更新日期:1977-02-01 00:00:00

  • MR imaging of the dilated biliary tract.

    abstract::The magnetic resonance (MR) examinations of 18 patients with dilated bile ducts were reviewed retrospectively to determine the capability of MR to demonstrate biliary dilatation, assess MR appearance of the dilated biliary tract using spin-echo techniques, and define the optimal MR imaging parameters (repetition time ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.2.3941860

    authors: Dooms GC,Fisher MR,Higgins CB,Hricak H,Goldberg HI,Margulis AR

    更新日期:1986-02-01 00:00:00

  • Lobar Ventilation in Patients with COPD Assessed with the Full-Scale Airway Network Flow Model and Xenon-enhanced Dual-Energy CT.

    abstract::Background The full-scale airway network (FAN) flow model shows excellent agreement with limited functional imaging data but requires further validation prior to clinical use. Purpose To validate the ventilation distributions computed with the FAN flow model with xenon ventilation from xenon-enhanced dual-energy (DE) ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020202485

    authors: Kim M,Doganay O,Hwang HJ,Seo JB,Gleeson FV

    更新日期:2021-01-01 00:00:00

  • Reduction of 18F-FDG Dose in Clinical PET/MR Imaging by Using Silicon Photomultiplier Detectors.

    abstract::Purpose To determine the level of clinically acceptable reduction in injected fluorine 18 (18F) fluorodeoxyglucose (FDG) dose in time-of-flight (TOF)-positron emission tomography(PET)/magnetic resonance (MR) imaging by using silicon photomultiplier (SiPM) detectors compared with TOF-PET/computed tomography (CT) using ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017162305

    authors: Sekine T,Delso G,Zeimpekis KG,de Galiza Barbosa F,Ter Voert EEGW,Huellner M,Veit-Haibach P

    更新日期:2018-01-01 00:00:00

  • Nuclear magnetic resonance evaluation of stroke. A preliminary report.

    abstract::Nine patients who had acute and subacute stroke were examined by nuclear magnetic resonance (NMR) using a 6-MHz Bruker Instruments proton scanner. A modified Carr-Purcell-Meiboom-Gill pulse sequence was used for signal detection. The resultant string of spin-echoes was Fourier transformed into projections that were su...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6310680

    authors: Bryan RN,Willcott MR,Schneiders NJ,Ford JJ,Derman HS

    更新日期:1983-10-01 00:00:00

  • Superparamagnetic iron oxide-enhanced MR imaging: pulse sequence optimization for detection of liver cancer.

    abstract::The effects of magnetic resonance (MR) pulse sequences and timing parameters on tumor-liver contrast were studied in an animal model of metastatic liver cancer. Six spin-echo (SE), three inversion-recovery (IR), and four gradient-echo (GRE) sequences were evaluated at 0.6 T before and after injection of super-paramagn...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.2.2748820

    authors: Fretz CJ,Elizondo G,Weissleder R,Hahn PF,Stark DD,Ferrucci JT Jr

    更新日期:1989-08-01 00:00:00

  • Ultrasonographic evidence of gallbladder wall thickening in association with hypoalbuminemia.

    abstract::Retrospective evaluation of 125 consecutive gallbladder sonograms was done to determine the conditions under which a thickened gallbladder wall is identified. The population studied included a large number of chronic alcoholics. Forty-two patients (Group A) had thickened (greater than or equal to 3 mm) gallbladder wal...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.3.7384460

    authors: Fiske CE,Laing FC,Brown TW

    更新日期:1980-06-01 00:00:00

  • Evaluation of the Patient Request Process for Radiology Imaging in U.S. Hospitals.

    abstract::Background In the United States, patients have the right to access their protected health information. However, to the knowledge of the authors, no study has evaluated the patient request process and the barriers to patient access of their radiology images. Purpose To assess U.S. hospital compliance with federal regul...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019190473

    authors: Lye CT,Krumholz HM,Eckroate JE,Daniel JG,deBronkart D,Mann MK,Hsiao AL,Forman HP

    更新日期:2019-08-01 00:00:00