Abstract:
OBJECTIVES:(1) To assess whether there is evidence of an association between the number of peri-implant tissue complications and patient characteristics such as gender, diabetes status, smoking status, and bite force; (2) To assess whether there is evidence of an association between the number of peri-implant tissue complications and location of the implant, surgical technique used, bone graft status and sinus lift status. MATERIALS AND METHODS:This randomized, controlled clinical trial included a total of 176 implants (OsseoSpeed, DENTSPLY) in 67 participants with 88 fixed dental prostheses. Information was obtained from health histories, a baseline exam, surgical notes, and post-operative exams. The data were analyzed using Fisher's exact and Mann-Whitney tests and generalized estimating equations using logistic regression with a significance level set at 0.05. RESULTS:All 176 implants survived within a recall period of 3 years, but 11 implants demonstrated peri-implant tissue complications. Ten sites showed dehiscence and one case exhibited vertical bone loss. There was a statistically significant association between surgical technique used (1-stage or 2-stage) and the presence of soft tissue complications (P = 0.005), where 2-stage surgery was associated with a higher frequency of peri-implant soft tissue complications. A correlation, although not statistically significant (P = 0.077), was noted, between peri-implant tissue complications and bone grafting, suggesting a possible role for this factor as well. CONCLUSIONS:Participants who did not require any second-stage surgery at the implant sites experienced fewer complications. Therefore, additional surgical procedures should be performed judiciously considering their possible effects on peri-implant tissue health. CLINICAL SIGNIFICANCE:The clinical implication of this research study is that secondary surgery should be considered with caution during implant placement and it should be performed only when other options have been exhausted, as it has been shown to have a direct adverse effect on the long-term peri-implant tissue health.
journal_name
Clin Oral Implants Resjournal_title
Clinical oral implants researchauthors
Esquivel-Upshaw J,Mehler A,Clark A,Neal D,Gonzaga L,Anusavice Kdoi
10.1111/clr.12484subject
Has Abstractpub_date
2015-12-01 00:00:00pages
1390-6issue
12eissn
0905-7161issn
1600-0501journal_volume
26pub_type
杂志文章,随机对照试验abstract:OBJECTIVES:Guided bone regeneration (GBR) is a commonly utilized surgical technique in the craniofacial region. The transcriptional mechanisms associated with this type of bone regeneration are not well understood. The aim of this study was to characterize the transcriptome associated with GBR of a critical-size calvar...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2010.02104.x
更新日期:2011-04-01 00:00:00
abstract::Non-submerged ITI Bonefit implants (ITI Dental Implant System) were inserted in edentulous lower jaws of 46 patients. The patients were provided with either a fixed prosthesis or an overdenture, and has been followed during a 2-year-period. At the 1-year examination, the suprastructures were removed permitting test of...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.1996.070406.x
更新日期:1996-12-01 00:00:00
abstract:OBJECTIVES:This study evaluated implant stability and clinical outcomes obtained with magnesium-incorporated oxidised implants (Mg titanate) and compared them to those blasted magnesium-incorporated oxidised implants (blasted Mg titanate). PATIENTS AND METHODS:Mg titanate was manufactured using the microarc oxidation ...
journal_title:Clinical oral implants research
pub_type: 杂志文章,随机对照试验
doi:10.1111/clr.12091
更新日期:2014-05-01 00:00:00
abstract:AIM:The aim of this clinical trial was to evaluate the safety and efficiency of a one-piece zirconia oral implant after 1 year of function. MATERIALS AND METHODS:Two centers included 60 subjects in need of implant-supported single-tooth restorations or three-unit bridges. A total of 71 zirconia one-piece implants were...
journal_title:Clinical oral implants research
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1111/clr.12670
更新日期:2016-07-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to explore effects of implant macrodesign and diameter on initial intraosseous stability and interface mechanical properties of immediately placed implants. MATERIAL AND METHOD:Mandibular premolars of four fresh-frozen human cadavers were extracted. Ø 4.1/4.8 mm ITI TE, Ø 4.1 ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2004.01099.x
更新日期:2005-04-01 00:00:00
abstract:OBJECTIVES:Although implants with a roughened surface are widely used today, little is known about the long-term effect of a roughened surface compared with the conventional machined surface on clinical and radiographic parameters. The purpose of this study is to investigate the long-term differences between moderately...
journal_title:Clinical oral implants research
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1600-0501.2009.01768.x
更新日期:2009-11-01 00:00:00
abstract:OBJECTIVES:To study the peri-implant bone organization pattern of immediately loaded (IL) zirconia implants with microgrooved surfaces. MATERIALS AND METHODS:Forty-eight dental implants of 4 mm diameter and 10 mm length were inserted after two months postextraction healing in the edentulous mandible of six dogs. Three...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.12461
更新日期:2015-11-01 00:00:00
abstract:BACKGROUND:Different therapeutic concepts and methods have been proposed for improving dental implant outcomes in three specific clinical situations: (i) the fresh extraction socket with alveolar ridge preservation protocols; (ii) the posterior maxilla with limited bone height with either the placement of regular-sized...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.12674
更新日期:2015-09-01 00:00:00
abstract:BACKGROUND:There is limited knowledge regarding the strength of zirconia abutments with internal and external implant abutment connections and zirconia abutments supported by a titanium resin base (Variobase, Straumann) for narrow diameter implants. OBJECTIVES:To compare the fracture strength of narrow diameter abutme...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.13139
更新日期:2018-04-01 00:00:00
abstract::The aim of the study was to investigate temperature changes at the implant-bone interface during simulated implant surface decontamination with a 809-nm gallium-aluminium-arsenid (GaAlAs) semiconductor laser. Stepped cylinder implants with a diameter of 3.8 mm and a length of 11 mm with two different surfaces (sand-bl...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.2003.140112.x
更新日期:2003-02-01 00:00:00
abstract:OBJECTIVES:The aim of the present study was to evaluate and compare naturally occuring and ligature-induced peri-implantitis bone defects in humans and dogs. MATERIAL AND METHODS:Twenty-four partially and fully edentulous patients undergoing peri-implant bone augmentation procedures due to advanced peri-implant infect...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2006.01320.x
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the bone regenerative properties of a heat treated cross-linked GBR membrane with zinc hydroxyapatite powders in the rat calvarial defect model over a 6-week period. MATERIAL AND METHODS:In vitro physio-chemical characterization involved X-ray diffraction analysis, s...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.12520
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare the efficacy of different instruments on biofilm removal from implant supported restorations. MATERIALS AND METHODS:The study was designed as comparative multicenter clinical study including patients proceeding from the Milan, Naples, and Buenos Aires, with a peri-implan...
journal_title:Clinical oral implants research
pub_type: 杂志文章,多中心研究
doi:10.1111/clr.12530
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVES:This study was conducted to evaluate the effect of barrier membranes on sandwich bone augmentation (SBA) for the treatment of implant dehiscence defects. MATERIAL AND METHODS:Twenty-six implant-associated buccal dehiscence defects in 22 patients were treated according to the SBA concept - mineralized human ...
journal_title:Clinical oral implants research
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1600-0501.2007.01408.x
更新日期:2008-01-01 00:00:00
abstract:OBJECTIVES:To assess the impact of collagen membrane application on bone formation surrounding implants placed simultaneously with the bone ring technique. MATERIAL AND METHODS:Dental implants were inserted simultaneously with the bone ring technique in standardized, vertical alveolar bony defects in the mandible of d...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.13543
更新日期:2020-01-01 00:00:00
abstract:INTRODUCTION:Despite the high success rates of endosseous oral implants, restrictions have been advocated to their placement with regard to the bone available in height and volume. The use of short or nonstandard-diameter implants could be one way to overcome this limitation. MATERIAL AND METHODS:In order to explore t...
journal_title:Clinical oral implants research
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0501.2006.01349.x
更新日期:2006-10-01 00:00:00
abstract:OBJECTIVES:The aim of this prospective pilot study was to evaluate the prosthodontic maintenance as well as the implant outcome of single implant-retained mandibular overdentures over an observation period of 6 years. METHODS:Eleven edentulous patients received one single implant in the midline of the mandible. Dentur...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.12427
更新日期:2015-10-01 00:00:00
abstract:OBJECTIVES:Minor sinus floor elevation is a method with relatively high predictability but is technically demanding. Improvement of the technique and increase in the predictability are desirable. MATERIAL AND METHODS:A clinical protocol for minor sinus floor elevation with SLA-ITI (large grit acid-etched implants with...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2005.01161.x
更新日期:2005-10-01 00:00:00
abstract::In the present study, the influence of initial instability on the healing of titanium implants was studied in 9 lop-eared rabbits. Titanium implants (Brånemark System) were inserted in the tibiae, a location with cortical bone only, in such a way that they were either stable (control), rotation-mobile, or totally mobi...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:
更新日期:1996-06-01 00:00:00
abstract::Currently, 3 treatment options are available for patients with denture complaints and an edentulous mandible with a height of at least 15 mm: meticulous construction of a new set of dentures (CD), construction of a new set of dentures following preprosthetic surgery to enlarge the denture-bearing area (PPS), and const...
journal_title:Clinical oral implants research
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1034/j.1600-0501.2000.011003195.x
更新日期:2000-06-01 00:00:00
abstract::The purpose of this study was to examine the healing potential and re-osseointegration in peri-implant infection defects adjacent to various implant surfaces. In 7 female Beagle dogs, a total of 41 titanium oral implants (ITI, Straumann, Waldenburg; Switzerland) with a sink depth of 6 mm (diameter 2.8 mm) were placed ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.1999.100205.x
更新日期:1999-04-01 00:00:00
abstract:OBJECTIVES:To investigate: (1) sinus membrane thickness in patients receiving lateral window sinus augmentation via cone-beam computed tomography (CBCT) and (2) the influence of Schneiderian membrane thickness upon membrane perforation during lateral window approach. MATERIAL AND METHODS:A total of 73 subjects with 81...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.12646
更新日期:2016-05-01 00:00:00
abstract::The purpose of the present in vitro investigation was to measure temperature changes at the implant surface when using pulsed CO2 laser in a simulated implant surface decontamination protocol. Six threaded titanium implants were placed in a fresh resected pig mandible. A 4 x 4 mm defect was created buccally to each im...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.1999.100107.x
更新日期:1999-02-01 00:00:00
abstract::The aim of this study is to evaluate a surgical protocol for vertical ridge augmentation in the maxilla and mandible using autogenous onlay bone graft associated with a titanium mesh. A group of 18 partially edentulous patients, presenting the need for vertical bone augmentation of at least 4 mm, were treated before i...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2004.00998.x
更新日期:2004-02-01 00:00:00
abstract:OBJECTIVES:To compare clinical and radiographic outcomes between transcrestal sinus floor elevation (TSFE) and lateral sinus floor elevation (LSFE) approaches of simultaneous implant placement in atrophic maxilla. MATERIALS AND METHODS:Patients with a residual bone height (RBH) ≤6 mm were enrolled and randomly assigne...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.13688
更新日期:2020-11-21 00:00:00
abstract:OBJECTIVE:To use cone beam computed tomography (CBCT) to assess the alterations of socket dimensions after a 6-month healing period following molar extraction. MATERIALS AND METHODS:Seventeen molars were extracted due to advanced periodontitis. CBCT scans were taken immediately after extraction and once more 6 months ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.13418
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVES:This in vitro study describes and characterizes a developed novel method to produce coatings on Ti. Hydrophobic coatings on substrates are needed in prosthetic dentistry to promote durable adhesion between luting resin cements and coated Ti surfaces. In implant dentistry the hydrophobic coatings on a Ti impl...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2012.02504.x
更新日期:2013-06-01 00:00:00
abstract:BACKGROUND:Cement-retained fixed implant-supported restorations involve the risk of excess cement, which can associate peri-implantitis. In connection with routine therapy using a methacrylate cement (Premier Implant Cement, Premier(®) Dental Products Company, Plymouth Meeting, PA, USA) to retain fixed implant-supporte...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.12173
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:The objective of this biomechanical study was to explore the effect of bone micro-morphology on initial intraosseous stability of implants with different designs. MATERIAL AND METHODS:Straumann and Astra Tech dental implants were placed into anterior and posterior regions of completely edentulous maxilla and m...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2006.01265.x
更新日期:2006-08-01 00:00:00
abstract:OBJECTIVE:The role of nanoscale/submicron morphological features in the process of osseointegration is largely unknown. This study reports the creation of a unique submicrofeatured titanium surface by a combination of anodic oxidation and sandblasting and determines how the addition of this submicrofeature to a microro...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2012.02507.x
更新日期:2013-09-01 00:00:00