Improvement of the prompt-gamma neutron activation facility at Brookhaven National Laboratory.

Abstract:

:The prompt-gamma neutron activation facility at Brookhaven National Laboratory was upgraded to improve both the precision and accuracy of its in vivo determinations of total body nitrogen. The upgrade, guided by Monte Carlo simulations, involved elongating and modifying the source collimator and its shielding, repositioning the system's two NaI(Tl) detectors, and improving the neutron and gamma shielding of these detectors. The new source collimator has a graphite reflector around the 238PuBe neutron source to enhance the low-energy region of the neutron spectrum incident on the patient. The gamma detectors have been relocated from positions close to the upward-emerging collimated neutron beam to positions close to and at the sides of the patient. These modifications substantially reduced spurious counts resulting from the capture of small-angle scattered neutrons in the NaI detectors. The pile-up background under the 10.8 MeV 14N(n, gamma)15N spectral peak has been reduced so that the nitrogen peak-to-background ratio has been increased by a factor of 2.8. The resulting reduction in the coefficient of variation of the total body nitrogen measurements from 3% to 2.2% has improved the statistical significance of the results possible for any given number of patient measurements. The new system also has a more uniform composite sensitivity.

journal_name

Phys Med Biol

authors

Dilmanian FA,Lidofsky LJ,Stamatelatos I,Kamen Y,Yasumura S,Vartsky D,Pierson RN Jr,Weber DA,Moore RI,Ma R

doi

10.1088/0031-9155/43/2/009

subject

Has Abstract

pub_date

1998-02-01 00:00:00

pages

339-49

issue

2

eissn

0031-9155

issn

1361-6560

journal_volume

43

pub_type

杂志文章
  • The preprocessing of retinal images for the detection of fluorescein leakage.

    abstract::Images of the human retina are routinely used in clinical practice for the diagnosis and management of eye disease. Increased permeability of retinal blood vessels, which is a clinically significant feature, can be visualized with a process known as fluorescein angiography as leakage of fluorescence dye into the surro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/1/021

    authors: Cree MJ,Olson JA,McHardy KC,Sharp PF,Forrester JV

    更新日期:1999-01-01 00:00:00

  • The induction of hyperthermia by ultrasound; its value and associated problems: II. Scanned-plane transducer.

    abstract::A system is described in which large superficial areas of tissue may be heated using a single plane ultrasonic transducer scanned in a raster fashion. The shape of the heated area is determined by the movement of a microswitch which is activated when it strikes the rigid edge of a hole of the required shape cut in a p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/12/006

    authors: ter Haar G,Hopewell JW

    更新日期:1985-12-01 00:00:00

  • Experimental verification of numerical simulations of cryosurgery with application to computerized planning.

    abstract::As a part of an ongoing effort to develop computerized planning tools for cryosurgery, an experimental study has been conducted to verify a recently developed numerical technique for bioheat transfer simulations. Experiments were performed on gelatin solution as a phantom material, using proprietary liquid-nitrogen cr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/15/013

    authors: Rossi MR,Rabin Y

    更新日期:2007-08-07 00:00:00

  • Independent Monte-Carlo dose calculation for MLC based CyberKnife radiotherapy.

    abstract::This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa97f8

    authors: Mackeprang PH,Vuong D,Volken W,Henzen D,Schmidhalter D,Malthaner M,Mueller S,Frei D,Stampanoni MFM,Dal Pra A,Aebersold DM,Fix MK,Manser P

    更新日期:2017-12-19 00:00:00

  • Chemically tuned linear energy transfer dependent quenching in a deformable, radiochromic 3D dosimeter.

    abstract::Most solid-state detectors, including 3D dosimeters, show lower signal in the Bragg peak than expected, a process termed quenching. The purpose of this study was to investigate how variation in chemical composition of a recently developed radiochromic, silicone-based 3D dosimeter influences the observed quenching in p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa512a

    authors: Høye EM,Skyt PS,Balling P,Muren LP,Taasti VT,Swakoń J,Mierzwińska G,Rydygier M,Bassler N,Petersen JB

    更新日期:2017-02-21 00:00:00

  • A neural network regression model for relative dose computation.

    abstract::This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/307

    authors: Wu X,Zhu Y

    更新日期:2000-04-01 00:00:00

  • A 3D reconstruction algorithm for magneto-acoustic tomography with magnetic induction based on ultrasound transducer characteristics.

    abstract::In this study we present a three-dimensional (3D) reconstruction algorithm for magneto-acoustic tomography with magnetic induction (MAT-MI) based on the characteristics of the ultrasound transducer. The algorithm is investigated to solve the blur problem of the MAT-MI acoustic source image, which is caused by the ultr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8762

    authors: Ma R,Zhou X,Zhang S,Yin T,Liu Z

    更新日期:2016-12-21 00:00:00

  • Lasso logistic regression to derive workflow-specific algorithm performance requirements as demonstrated for head and neck cancer deformable image registration in adaptive radiation therapy.

    abstract::As automation in radiation oncology becomes more common, it is important to determine which algorithms are equivalent for a given workflow. Often, algorithm comparisons are performed in isolation; however, clinical context can provide valuable insight into the importance of algorithm features and error magnification i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9fc8

    authors: Weppler S,Schinkel C,Kirkby C,Smith W

    更新日期:2020-09-28 00:00:00

  • Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner.

    abstract::An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/008

    authors: Lehnert W,Meikle SR,Siegel S,Newport D,Banati RB,Rosenfeld AB

    更新日期:2006-08-21 00:00:00

  • Design, construction and use of a large-sample field-cycled PEDRI imager.

    abstract::The design, construction and use of a large-scale field-cycled proton-electron double-resonance imaging (FC-PEDRI) imager is described. The imager is based on a whole-body sized, vertical field, 59 mT permanent magnet. Field cycling is accomplished by the field compensation method, and uses a secondary, resistive magn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/7/008

    authors: Lurie DJ,Foster MA,Yeung D,Hutchison JM

    更新日期:1998-07-01 00:00:00

  • The effects of renal variation upon measurements of perfusion and leakage volume in breast tumours.

    abstract::Dynamic contrast enhanced MRI (DCE-MRI) and pharmacokinetic models have been used to measure tumour permeability (K(trans)) and leakage volume (ve) in numerous studies. The construction of pharmacokinetic models describing such tissue properties relies on defining the blood plasma concentration of contrast agent with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/10/014

    authors: Ahearn TS,Staff RT,Redpath TW,Semple SI

    更新日期:2004-05-21 00:00:00

  • Segmentation of dynamic PET images with kinetic spectral clustering.

    abstract::Segmentation is often required for the analysis of dynamic positron emission tomography (PET) images. However, noise and low spatial resolution make it a difficult task and several supervised and unsupervised methods have been proposed in the literature to perform the segmentation based on semi-automatic clustering of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/19/6931

    authors: Mouysset S,Zbib H,Stute S,Girault JM,Charara J,Noailles J,Chalon S,Buvat I,Tauber C

    更新日期:2013-10-07 00:00:00

  • PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems.

    abstract::Monte Carlo simulation techniques are applied to track the annihilation photons from positron decay, and store the photon histories. Reasonably realistic models of the isotope distribution in the brain and heart during typical PET studies, as well as the traditional phantoms used for measuring PET scanner performance ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/3/017

    authors: Thompson CJ,Moreno-Cantu J,Picard Y

    更新日期:1992-03-01 00:00:00

  • Computational errors of the induced electric field in voxelized and tetrahedral anatomical head models exposed to spatially uniform and localized magnetic fields.

    abstract::At low and intermediate frequencies, the strength of the induced electric field is used as dosimetric quantity for human protection in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. To compute the induced electric field, numerical methods based on anatomically realistic voxel mo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5dfb

    authors: Soldati M,Laakso I

    更新日期:2020-01-10 00:00:00

  • Normal levels of total body sodium and chlorine by neutron activation analysis.

    abstract::In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/3/002

    authors: Kennedy NS,Eastell R,Smith MA,Tothill P

    更新日期:1983-03-01 00:00:00

  • Origin and quantification of differences between normal and tumor tissues observed by terahertz spectroscopy.

    abstract::The origin of the differences in the refractive index observed between normal and tumor tissues using terahertz spectroscopy has been described quantitatively. To estimate water content differences in tissues, we prepared fresh and paraffin-embedded samples from rats. An approximately 5% increase of water content in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6808

    authors: Yamaguchi S,Fukushi Y,Kubota O,Itsuji T,Ouchi T,Yamamoto S

    更新日期:2016-09-21 00:00:00

  • Directional x-ray dark-field imaging.

    abstract::We introduce a novel x-ray imaging approach that yields information about the local texture of structures smaller than the image pixel resolution inside an object. The approach is based on a recently developed x-ray dark-field imaging technique, using scattering from sub-micron structures in the sample. We show that t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/004

    authors: Jensen TH,Bech M,Bunk O,Donath T,David C,Feidenhans'l R,Pfeiffer F

    更新日期:2010-06-21 00:00:00

  • Use of forward projection to correct patient motion during SPECT imaging.

    abstract::We have developed an iterative method to correct axial and tangential patient motion occurring during tomographic acquisition. The method uses axial images reconstructed from the uncorrected projection images, which are then forward projected to form a basis for registering the original planar images and, in the proce...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/1/011

    authors: Lee KJ,Barber DC

    更新日期:1998-01-01 00:00:00

  • An analysis of beam parameters on proton-acoustic waves through an analytic approach.

    abstract::It has been reported that acoustic waves are generated when a high-energy pulsed proton beam is deposited in a small volume within tissue. One possible application of proton-induced acoustics is to get real-time feedback for intra-treatment adjustments by monitoring such acoustic waves. A high spatial resolution in ul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa642c

    authors: Kipergil EA,Erkol H,Kaya S,Gulsen G,Unlu MB

    更新日期:2017-06-21 00:00:00

  • Estimation of tissue resistivities from multiple-electrode impedance measurements.

    abstract::In order to measure in vivo resistivity of tissues in the thorax, the possibility of combining anatomical data extracted from high-resolution images with multiple-electrode impedance measurements, a priori knowledge of the range of tissue resistivities, and a priori data on the instrumentation noise is assessed in thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/1/001

    authors: Eyüboğlu BM,Pilkington TC,Wolf PD

    更新日期:1994-01-01 00:00:00

  • 4D image reconstruction for emission tomography.

    abstract::An overview of the theory of 4D image reconstruction for emission tomography is given along with a review of the current state of the art, covering both positron emission tomography and single photon emission computed tomography (SPECT). By viewing 4D image reconstruction as a matter of either linear or non-linear par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/22/R371

    authors: Reader AJ,Verhaeghe J

    更新日期:2014-11-21 00:00:00

  • Microwave tomography for functional imaging of extremity soft tissues: feasibility assessment.

    abstract::It is important to assess the viability of extremity soft tissues, as this component is often the determinant of the final outcome of fracture treatment. Microwave tomography (MWT) and sensing might be able to provide a fast and mobile assessment of such properties. MWT imaging of extremities possesses a complicated, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/18/015

    authors: Semenov S,Kellam J,Althausen P,Williams T,Abubakar A,Bulyshev A,Sizov Y

    更新日期:2007-09-21 00:00:00

  • Volumetric characterization of the Aurora magnetic tracker system for image-guided transorbital endoscopic procedures.

    abstract::In some medical procedures, it is difficult or impossible to maintain a line of sight for a guidance system. For such applications, people have begun to use electromagnetic trackers. Before a localizer can be effectively used for an image-guided procedure, a characterization of the localizer is required. The purpose o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/16/009

    authors: Atuegwu NC,Galloway RL

    更新日期:2008-08-21 00:00:00

  • Reduction of scatter in breast CT yields improved microcalcification visibility.

    abstract::The inadequate visibility of microcalcifications-small calcium deposits that cue radiologists to early stages of cancer-is a major limitation in current designs of dedicated breast computed tomography (bCT). This limitation has previously been attributed to the constituent components, spatial resolution, and utilized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abae07

    authors: Ghazi P

    更新日期:2020-12-04 00:00:00

  • [A simulation method for studying scintillation camera collimators].

    abstract::This paper presents a computer simulation of photon interaction with collimator septa, which allows the point spread function of scintillation camera collimators to be calculated. The method simulates photon attenuation along their propagation direction in a determinist way. Using this simulation, the spatial resoluti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/5/006

    authors: Gantet P,Esquerré JP,Danet B,Guiraud R

    更新日期:1990-05-01 00:00:00

  • Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.

    abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/N04

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Bollini D,de Notaristefani F

    更新日期:2006-05-07 00:00:00

  • Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images.

    abstract::A method is presented for extraction of intra and inter fraction motion of seeds/markers within the patient from cone beam CT (CBCT) projection images. The position of the marker is determined on each projection image and fitted to a function describing the projection of a fixed point onto the imaging panel at differe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/018

    authors: Marchant TE,Amer AM,Moore CJ

    更新日期:2008-02-21 00:00:00

  • On the surviving fraction in irradiated multicellular tumour spheroids: calculation of overall radiosensitivity parameters, influence of hypoxia and volume effects.

    abstract::We model the heterogeneous response to radiation of multicellular tumour spheroids assuming position- and volume-dependent radiosensitivity. We propose a method to calculate the overall radiosensitivity parameters to obtain the surviving fraction of tumours. A mathematical model of a spherical tumour with a hypoxic co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/8/005

    authors: Horas JA,Olguin OR,Rizzotto MG

    更新日期:2005-04-21 00:00:00

  • A feasibility study of the use of fluorescence bronchoscopy for localization of small lung tumours.

    abstract::The possible use of fluorescence bronchoscopy for localization of bronchogenic tumours at the carcinoma in situ stage has been investigated. The target lesion is 80 micrometer thick with a mass of 250 microgram, containing 250 pg of haematoporphyrin derivative. The injected haematoporphyrin-derivative is preferentiall...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/014

    authors: Profio AE,Doiron DR

    更新日期:1977-09-01 00:00:00

  • Online prediction of respiratory motion: multidimensional processing with low-dimensional feature learning.

    abstract::Accurate real-time prediction of respiratory motion is desirable for effective motion management in radiotherapy for lung tumor targets. Recently, nonparametric methods have been developed and their efficacy in predicting one-dimensional respiratory-type motion has been demonstrated. To exploit the correlation among v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/11/002

    authors: Ruan D,Keall P

    更新日期:2010-06-07 00:00:00