Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults.

Abstract:

OBJECTIVE:To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing ≥ 91 kg. METHODS:In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing ≥ 91 kg (mean body weight: 107.6 ± 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. RESULTS:All examinations were found to be of adequate quality. Both subjective (mean = 1.4 ± 0.5 vs. 1.6 ± 0.6, P < 0.05) and objective noise (13.0 ± 3.2 vs.19.5 ± 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 ± 7.3 mGy; FBP: 19.7 ± 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. CONCLUSION:In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. KEY POINTS:• CT images in obese adults are noisy, even with high radiation dose. • Newer iterative reconstruction techniques have theoretical advantages in obese patients. • Adaptive statistical iterative reconstruction should reduce image noise and radiation dose. • This has been proven in abdominopelvic CT images of obese patients.

journal_name

Eur Radiol

journal_title

European radiology

authors

Desai GS,Uppot RN,Yu EW,Kambadakone AR,Sahani DV

doi

10.1007/s00330-012-2424-3

subject

Has Abstract

pub_date

2012-08-01 00:00:00

pages

1631-40

issue

8

eissn

0938-7994

issn

1432-1084

journal_volume

22

pub_type

杂志文章
  • Staging of colorectal liver metastases after preoperative chemotherapy. Diffusion-weighted imaging in combination with Gd-EOB-DTPA MRI sequences increases sensitivity and diagnostic accuracy.

    abstract:OBJECTIVES:To compare the diagnostic accuracy and sensitivity of Gd-EOB-DTPA MRI and diffusion-weighted (DWI) imaging alone and in combination for detecting colorectal liver metastases in patients who had undergone preoperative chemotherapy. METHODS:Thirty-two consecutive patients with a total of 166 liver lesions wer...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2658-0

    authors: Macera A,Lario C,Petracchini M,Gallo T,Regge D,Floriani I,Ribero D,Capussotti L,Cirillo S

    更新日期:2013-03-01 00:00:00

  • Prediction of infarction development after endovascular stroke therapy with dual-energy computed tomography.

    abstract:OBJECTIVES:After intraarterial recanalisation (IAR), the haemorrhage and the blood-brain barrier (BBB) disruption can be distinguished using dual-energy computed tomography (DECT). The aim of the present study was to investigate whether future infarction development can be predicted from DECT. METHODS:DECT scans of 20...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4412-5

    authors: Djurdjevic T,Rehwald R,Knoflach M,Matosevic B,Kiechl S,Gizewski ER,Glodny B,Grams AE

    更新日期:2017-03-01 00:00:00

  • Esophageal duplication cyst coexisting with Bochdalek's hernia and polysplenia.

    abstract::Esophageal duplication cyst, Bochdalek's hernia and polysplenia are uncommon congenital anomalies which have not been reported to be associated with each other. We present the radiological aspects of an unusual coexistence of these three congenital anomalies in a 4-month-old girl. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050696

    authors: Seçil M,Göktay AY,Karabay N,Iğci E,Pirnar T

    更新日期:1999-01-01 00:00:00

  • Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing.

    abstract::Streak artifact is an important source of image degradation in computed tomographic imaging. In coronary MDCT angiography, streak artifact from pacemaker leads in the SVC can render segments of the right coronary artery uninterpretable. With current technology in clinical practice, there is no effective way to elimina...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1013-y

    authors: Meyer LT,Boll DT

    更新日期:2008-11-01 00:00:00

  • Magnetic resonance imaging of the bone marrow in hematological malignancies.

    abstract::Despite its lack of specificity, magnetic resonance imaging (MRI) of the bone marrow has the potential to play a role in the management of patients with primary neoplastic disorders of the hematopoietic system, including lymphomas, leukemias and multiple myeloma. In addition to its use in the assessment of suspected s...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050548

    authors: Vande Berg BC,Lecouvet FE,Michaux L,Ferrant A,Maldague B,Malghem J

    更新日期:1998-01-01 00:00:00

  • Quantification of diffusion tensor imaging in normal white matter maturation of early childhood using an automated processing pipeline.

    abstract:OBJECTIVES:The degree and status of white matter myelination can be sensitively monitored using diffusion tensor imaging (DTI). This study looks at the measurement of fractional anistropy (FA) and mean diffusivity (MD) using an automated ROI with an existing DTI atlas. METHODS:Anatomical MRI and structural DTI were pe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2396-3

    authors: Loh KB,Ramli N,Tan LK,Roziah M,Rahmat K,Ariffin H

    更新日期:2012-07-01 00:00:00

  • Radiological staging of ovarian cancer: imaging findings and contribution of CT and MRI.

    abstract::Ovarian cancer is the most lethal among the gynecologic malignancies with approximately 70% of patients presenting with advanced tumor stage. The prognosis of patients with ovarian cancer is directly related to the tumor stage and residual tumor burden after cytoreductive surgery. Exploratory laparotomy has been the c...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-007-0736-5

    authors: Forstner R

    更新日期:2007-12-01 00:00:00

  • Nonvariceal upper gastrointestinal bleeding.

    abstract::Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decre...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0477-x

    authors: Burke SJ,Golzarian J,Weldon D,Sun S

    更新日期:2007-07-01 00:00:00

  • Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications.

    abstract::Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2236-1

    authors: Reimer P,Schneider G,Schima W

    更新日期:2004-04-01 00:00:00

  • High-resolution real-time compound ultrasound imaging of transient protein-losing gastropathy of childhood.

    abstract::We report the case of a 1.5-year-old girl with transient protein-losing gastropathy with hypertrophic gastric folds (PLGH). The diagnosis of PLGH was made by abdominal ultrasound (US) and not by an upper gastrointestinal (UGI) study as reported in many previous publications. Real-time compound ultrasound imaging showe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2071-9

    authors: Smet MH,Mussen E,Ectors N,Breysem L

    更新日期:2003-12-01 00:00:00

  • Normative volume measurements of the fetal intra-cranial compartments using 3D volume in utero MR imaging.

    abstract:PURPOSE:To describe the normal linear measurements of the skull (bi-parietal diameter and occipito-frontal diameter) and intracranial volumes (ventricular volume, brain parenchymal volume, extra-axial volume and total intra-cranial volume) in normal fetuses. MATERIALS AND METHODS:We recruited pregnant women from low-r...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5938-5

    authors: Jarvis DA,Finney CR,Griffiths PD

    更新日期:2019-07-01 00:00:00

  • PET/CT in primary musculoskeletal tumours: a step forward.

    abstract::Hybrid imaging with combined positron emission tomography/computed tomography (PET/CT) plays an important role in the staging and management of a wide variety of solid tumours. However, its use in the evaluation of musculoskeletal malignancy has not yet entered routine clinical practice. Cross-sectional imaging with m...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-010-1862-z

    authors: Lakkaraju A,Patel CN,Bradley KM,Scarsbrook AF

    更新日期:2010-12-01 00:00:00

  • Cystic versus predominantly cystic thyroid nodules: efficacy of ethanol ablation and analysis of related factors.

    abstract:OBJECTIVES:To compare the efficacy of ethanol ablation (EA) of cystic and predominantly cystic thyroid nodules, and to evaluate factors affecting efficacy. METHODS:From October 2008 to December 2010, a total of 217 thyroid nodules were treated with EA. Nodule volumes, symptoms and cosmetic scores were evaluated before...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2406-5

    authors: Kim YJ,Baek JH,Ha EJ,Lim HK,Lee JH,Sung JY,Kim JK,Kim TY,Kim WB,Shong YK

    更新日期:2012-07-01 00:00:00

  • Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now.

    abstract:UNLABELLED:Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR...

    journal_title:European radiology

    pub_type: 社论

    doi:10.1007/s00330-015-3945-3

    authors: Messina C,Banfi G,Aliprandi A,Mauri G,Secchi F,Sardanelli F,Sconfienza LM

    更新日期:2016-05-01 00:00:00

  • Ultrasound features of malignancy in the preoperative diagnosis of parathyroid cancer: a retrospective analysis of parathyroid tumours larger than 15 mm.

    abstract:OBJECTIVE:Nearly all reported parathyroid cancers are >15 mm at presentation. The objective was to identify ultrasound criteria of malignancy in parathyroid lesions of >15 mm in size. MATERIALS AND METHODS:This study was approved by a local ethics committee. A retrospective review of patients identified from a databas...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2141-3

    authors: Sidhu PS,Talat N,Patel P,Mulholland NJ,Schulte KM

    更新日期:2011-09-01 00:00:00

  • Anatomic variations of the hepatic arteries in 250 patients studied with 64-row CT angiography.

    abstract::The aim of our study was to determine the frequency of different hepatic arterial variants identified on abdominal CT angiography (CTA) with a 64-row CT system and a high resolution protocol. A total of 250 consecutive abdominal CTAs performed on a 64-row CT system were evaluated. Two radiologists in consensus analyze...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1458-7

    authors: De Cecco CN,Ferrari R,Rengo M,Paolantonio P,Vecchietti F,Laghi A

    更新日期:2009-11-01 00:00:00

  • Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients: initial experience.

    abstract::The application of image registration and subtraction to detect change in multiple sclerosis (MS) disease burden on serial MR scans benefits from the use of isotropic voxels. An optimised 3D fast fluid-attenuated inversion recovery (FLAIR) sequence with 1.2- and 1.8-mm cubic voxels was compared with a 2D T2 SE sequenc...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1170-8

    authors: Tan IL,Pouwels PJ,van Schijndel RA,Adèr HJ,Manoliu RA,Barkhof F

    更新日期:2002-03-01 00:00:00

  • High-resolution myocardial perfusion imaging at 3 T: comparison to 1.5 T in healthy volunteers.

    abstract::The purpose of this study was to evaluate high-resolution (HR) myocardial first-pass perfusion in healthy volunteers at 3 T compared to a typical clinical imaging protocol at 1.5 T, with respect to overall image quality and the presence of subendocardial dark rim artifacts. Myocardial first-pass rest perfusion studies...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0560-3

    authors: Strach K,Meyer C,Thomas D,Naehle CP,Schmitz C,Litt H,Bernstein A,Cheng B,Schild H,Sommer T

    更新日期:2007-07-01 00:00:00

  • Quantification of bronchial dimensions at MDCT using dedicated software.

    abstract::This study aimed to assess the feasibility of quantification of bronchial dimensions at MDCT using dedicated software (BronCare). We evaluated the reliability of the software to segment the airways and defined criteria ensuring accurate measurements. BronCare was applied on two successive examinations in 10 mild asthm...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0496-7

    authors: Brillet PY,Fetita CI,Beigelman-Aubry C,Saragaglia A,Perchet D,Preteux F,Grenier PA

    更新日期:2007-06-01 00:00:00

  • Automated computer-aided stenosis detection at coronary CT angiography: initial experience.

    abstract:OBJECTIVE:To evaluate the performance of a computer-aided algorithm for automated stenosis detection at coronary CT angiography (cCTA). METHODS:We investigated 59 patients (38 men, mean age 58 +/- 12 years) who underwent cCTA and quantitative coronary angiography (QCA). All cCTA data sets were analyzed using a softwar...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1644-7

    authors: Arnoldi E,Gebregziabher M,Schoepf UJ,Goldenberg R,Ramos-Duran L,Zwerner PL,Nikolaou K,Reiser MF,Costello P,Thilo C

    更新日期:2010-05-01 00:00:00

  • Feasibility of whole-body diffusion-weighted MRI for detection of primary tumour, nodal and distant metastases in women with cancer during pregnancy: a pilot study.

    abstract:OBJECTIVES:To evaluate the feasibility of whole-body diffusion-weighted MRI (WB-DWI/MRI) for detecting primary tumour, nodal and distant metastases in pregnant women with cancer. METHODS:Twenty pregnant patients underwent WB-DWI/MRI in additional to conventional imaging. Reproducibility of WB-DWI/MRI between two reade...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5126-z

    authors: Han SN,Amant F,Michielsen K,De Keyzer F,Fieuws S,Van Calsteren K,Dresen RC,Gziri MM,Vandecaveye V

    更新日期:2018-05-01 00:00:00

  • Presinusoidal portal hypertension does not affect hepatic artery resistance index.

    abstract::We aimed to determine the mean hepatic artery resistance index (RI) in presinusoidal portal hypertension and to compare the values with those in sinusoidal portal hypertension. The hepatic artery RIs of 11 patients with presinusoidal portal hypertension, 12 patients with sinusoidal portal hypertension and 16 healthy s...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050806

    authors: Erden A,Altuntaş B,Olçer T,Cumhur T

    更新日期:1999-01-01 00:00:00

  • Imaging strategies in pediatric urinary tract infection.

    abstract::This article is focused on the controversial topic of imaging strategies in pediatric urinary tract infection. A review of the recent literature illustrates the complementary roles of ultrasound, diagnostic radiology and nuclear medicine. The authors stress the key role of ultrasound which has recently been debated. T...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-005-2702-4

    authors: Dacher JN,Hitzel A,Avni FE,Vera P

    更新日期:2005-07-01 00:00:00

  • Non-invasive imaging of myocardial bridge by coronary computed tomography angiography: the value of transluminal attenuation gradient to predict significant dynamic compression.

    abstract:OBJECTIVES:To study the diagnostic value of transluminal attenuation gradient (TAG) measured by coronary computed tomography angiography (CCTA) for identifying relevant dynamic compression of myocardial bridge (MB). METHODS:Patients with confirmed MB who underwent both CCTA and ICA within one month were retrospectivel...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4544-7

    authors: Li Y,Yu M,Zhang J,Li M,Lu Z,Wei M

    更新日期:2017-05-01 00:00:00

  • Primitive hypoglossal artery: demonstration with digital subtraction-, MR- and CT angiography.

    abstract::The primitive hypoglossal artery (PHA) is a rare persistent carotid-basilar anastomosis. Usually it is found incidentally on angiography, but detection may be of importance for patient management. In the presented case MR- and CT angiography, which to our knowledge have not yet been reported in PHA, provided important...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050322

    authors: Oelerich M,Schuierer G

    更新日期:1997-01-01 00:00:00

  • The PPRD score stratifies patients with hepatocellular carcinoma and portal vein tumor thrombus treated with sorafenib plus transarterial chemoembolization.

    abstract:OBJECTIVES:To identify clinical prognostic and predictive factors in patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT) undergoing sorafenib plus transarterial chemoembolization (TACE) and establish a prognostic score for these patients. METHODS:Between January 2012 and December 2017, 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07078-z

    authors: Zhang Y,Miao H,Xie W,Jiang S,Song Z,Huang G,Fan W,Wang Y,Li J,Chen Y

    更新日期:2021-01-01 00:00:00

  • Non-tuberculous iliopsoas abscess due to perforated diverticulitis presenting with intestinal obstruction and a groin mass.

    abstract::Psoas abscess is an uncommon condition and, contrary to traditional teaching, tends to be of non-tuberculous aetiology in developed countries. Diagnosis can be delayed since presenting features are non-specific and in many instances misleading, necessitating a high degree of clinical suspicion and early resort to cros...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000661

    authors: Kaul V,Jackson M,Farrugia M

    更新日期:2001-01-01 00:00:00

  • Hemodynamic effects of decompressive craniotomy in MCA infarction: evaluation with perfusion CT.

    abstract::Decompressive craniotomy in hemispheric infarction has been reported to reduce mortality and improve outcome. Identifying tissue at risk and monitoring the benefit of craniotomy is hardly practical and has not been reported thus far. Perfusion CT was applied before and immediately after decompressive craniotomy in a p...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1656-z

    authors: Bendszus M,Müllges W,Goldbrunner R,Weigand A,Solymosi L

    更新日期:2003-08-01 00:00:00

  • Malignancy rates and diagnostic performance of the Bosniak classification for the diagnosis of cystic renal lesions in computed tomography - a systematic review and meta-analysis.

    abstract:OBJECTIVE:To systematically review the literature on the Bosniak classification system in CT to determine its diagnostic performance to diagnose malignant cystic lesions and the prevalence of malignancy in Bosniak categories. METHODS:A predefined database search was performed from 1 January 1986 to 18 January 2016. Tw...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s00330-016-4631-9

    authors: Sevcenco S,Spick C,Helbich TH,Heinz G,Shariat SF,Klingler HC,Rauchenwald M,Baltzer PA

    更新日期:2017-06-01 00:00:00

  • The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

    abstract:OBJECTIVES:In dual-source CT, dual-energy (DE) performance is affected by various X-ray tube voltage combinations with and without tin filter (Sn). The purpose of this study was to assess the utility of the 80/150 Sn kV voltage combination in terms of image artefact and radiation dose for DECT gout protocol, compared w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5622-9

    authors: Jeon JY,Lee SW,Jeong YM,Baek HJ

    更新日期:2019-03-01 00:00:00