Imaging strategies in pediatric urinary tract infection.

Abstract:

:This article is focused on the controversial topic of imaging strategies in pediatric urinary tract infection. A review of the recent literature illustrates the complementary roles of ultrasound, diagnostic radiology and nuclear medicine. The authors stress the key role of ultrasound which has recently been debated. The commonly associated vesicoureteric reflux has to be classified as congenital or secondary due to voiding dysfunction. A series of frequently asked questions are addressed in a second section. The proposed answers are not the product of a consensus but should rather be considered as proposals to enrich the ongoing debate concerning the evaluation of urinary tract infection in children.

journal_name

Eur Radiol

journal_title

European radiology

authors

Dacher JN,Hitzel A,Avni FE,Vera P

doi

10.1007/s00330-005-2702-4

subject

Has Abstract

pub_date

2005-07-01 00:00:00

pages

1283-8

issue

7

eissn

0938-7994

issn

1432-1084

journal_volume

15

pub_type

杂志文章,评审
  • Inter-scan and inter-scanner variation of quantitative dual-energy CT: evaluation with three different scanner types.

    abstract:OBJECTIVES:To investigate inter-scan and inter-scanner variation of iodine concentration (IC) and attenuation in virtual monoenergetic images at 65 keV (HU65keV) in patients with repeated abdominal examinations on dual-source (dsDECT), rapid kV switching (rsDECT), and dual-layer detector DECT (dlDECT). METHODS:We retr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07611-0

    authors: Lennartz S,Parakh A,Cao J,Zopfs D,Große Hokamp N,Kambadakone A

    更新日期:2021-01-14 00:00:00

  • Coronary calcium score and computed tomography coronary angiography in high-risk asymptomatic subjects: assessment of diagnostic accuracy and prevalence of non-obstructive coronary artery disease.

    abstract:OBJECTIVES:The aim of the study was to compare the coronary artery calcium score (CACS) and computed tomography coronary angiography (CTCA) for the assessment of non-obstructive/obstructive coronary artery disease (CAD) in high-risk asymptomatic subjects. METHODS:Two hundred and thirteen consecutive asymptomatic subje...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1612-2

    authors: Cademartiri F,Maffei E,Palumbo A,Seitun S,Martini C,Tedeschi C,La Grutta L,Midiri M,Weustink AC,Mollet NR,Krestin GP

    更新日期:2010-04-01 00:00:00

  • A pregnant lady with intermittent vaginal bleeding (2007: 3b). Placenta percreta.

    abstract::Placenta percreta is a potentially life-threatening complication of pregnancy, which is increasing in incidence. Ante-natal diagnosis with ultrasound and magnetic resonance imaging aids the obstetric team in planning further management. We present a case of placenta percreta with imaging and a brief review of the lite...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0498-5

    authors: Koo BC,Sala E,Hackett GA,Shaw AS

    更新日期:2007-06-01 00:00:00

  • Detection of intralabyrinthine abnormalities using post-contrast delayed 3D-FLAIR MRI sequences in patients with acute vestibular syndrome.

    abstract:PURPOSE:3D-FLAIR sequences with delayed acquisition after contrast medium injection have demonstrated new insights into blood-labyrinthine barrier (BLB) abnormalities in various diseases. The aim of this study was to assess the BLB in patients referred with unilateral acute vestibular syndrome (UAVS). MATERIALS AND ME...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-018-5825-0

    authors: Eliezer M,Maquet C,Horion J,Gillibert A,Toupet M,Bolognini B,Magne N,Kahn L,Hautefort C,Attyé A

    更新日期:2019-06-01 00:00:00

  • Heterotropic mesenteric ossification: a case report (2004:10b).

    abstract::Heterotropic mesenteric ossification is a rare entity. Only a few cases have been described in the literature. We report a case of heterotropic mesenteric ossification in a patient who underwent several laparotomies, after suffering from multiple gunshot wounds. We discuss the radiographic findings of this disease tha...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2464-4

    authors: Tonino BA,van der Meulen HG,Kuijpers KC,Mallens WM,van Gils AP

    更新日期:2005-01-01 00:00:00

  • The value of fast MR imaging as an adjunct to ultrasound in prenatal diagnosis.

    abstract::The aim of this study was to evaluate the role of MR imaging of the fetus to improve sonographic prenatal diagnosis of congenital anomalies. In 40 fetuses (not consecutive cases) with an abnormality diagnosed with ultrasound, additional MR imaging was performed. The basic sequence was a T2-weighted single-shot half Fo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1811-6

    authors: Breysem L,Bosmans H,Dymarkowski S,Schoubroeck DV,Witters I,Deprest J,Demaerel P,Vanbeckevoort D,Vanhole C,Casaer P,Smet M

    更新日期:2003-07-01 00:00:00

  • Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography.

    abstract::The purpose of this study was to compare moving-table three-dimensional contrast-enhanced magnetic resonance angiography (CE MRA), using 1.0-mol gadobutrol, with intra-arterial digital subtraction angiography (i.a. DSA) for evaluation of pelvic and peripheral arteries in patients with peripheral arterial occlusive dis...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1007/s00330-003-1844-5

    authors: Hentsch A,Aschauer MA,Balzer JO,Brossmann J,Busch HP,Davis K,Douek P,Ebner F,van Engelshoven JM,Gregor M,Kersting C,Knüsel PR,Leen E,Leiner T,Loewe C,McPherson S,Reimer P,Schäfer FK,Taupitz M,Thurnher SA,Tombach B

    更新日期:2003-09-01 00:00:00

  • Quantification of blood flow.

    abstract::Traditionally, Doppler ultrasound has been used to estimate blood flow as the mean velocity multiplied by the vessel area, but this is subject to significant errors and may be difficult to perform accurately. Microbubbles, developed as contrast agents for ultrasound, were initially envisaged as useful for increasing t...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300100985

    authors: Cosgrove D,Eckersley R,Blomley M,Harvey C

    更新日期:2001-01-01 00:00:00

  • Cervical myositis ossificans traumatica: a rare location.

    abstract::An unusual case of myositis ossificans traumatica lesion located in the paraspinal region is reported. Despite the contiguity of the lesion with the cervical vertebrae and ominous appearance of the biopsy material, the history of antecedent trauma and computed tomography findings allowed preoperative accurate diagnosi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050728

    authors: Baysal T,Baysal O,Sarac K,Elmali N,Kutlu R,Ersoy Y

    更新日期:1999-01-01 00:00:00

  • Nitroglycerine use in transcatheter arterial (chemo)embolization in patients with hepatocellular carcinoma and dual-energy CT assessment of Lipiodol retention.

    abstract:OBJECTIVES:To investigate whether the addition of nitroglycerine to transcatheter arterial (chemo)embolization (TAE/TACE) can increase the delivery and effectiveness of TAE/TACE in patients with hepatocellular carcinoma (HCC) by dual-energy CT. METHODS:HCC patients (BCLC stage A or B) were randomized to (n = 51) or no...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-012-2484-4

    authors: Liu YS,Chuang MT,Tsai YS,Tsai HM,Lin XZ

    更新日期:2012-10-01 00:00:00

  • Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method.

    abstract:OBJECTIVES:To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. METHODS:Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3952-4

    authors: Varga-Szemes A,Muscogiuri G,Schoepf UJ,Wichmann JL,Suranyi P,De Cecco CN,Cannaò PM,Renker M,Mangold S,Fox MA,Ruzsics B

    更新日期:2016-05-01 00:00:00

  • Isoattenuating insulinomas at biphasic contrast-enhanced CT: frequency, clinicopathologic features and perfusion characteristics.

    abstract:OBJECTIVES:We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. METHODS:Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 20...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4216-7

    authors: Zhu L,Xue HD,Sun H,Wang X,He YL,Jin ZY,Zhao YP

    更新日期:2016-10-01 00:00:00

  • Whole-body [¹⁸F]FDG PET/MRI vs. PET/CT in the assessment of bone lesions in oncological patients: initial results.

    abstract:OBJECTIVES:To compare [(18)F]FDG PET/MRI with PET/CT for the assessment of bone lesions in oncologic patients. METHODS:This prospective study included 67 patients with solid tumours scheduled for PET/CT with [(18)F]FDG who also underwent a whole-body PET/MRI scan. The datasets (PET/CT, PET/MRI) were rated by two reade...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3229-3

    authors: Beiderwellen K,Huebner M,Heusch P,Grueneisen J,Ruhlmann V,Nensa F,Kuehl H,Umutlu L,Rosenbaum-Krumme S,Lauenstein TC

    更新日期:2014-08-01 00:00:00

  • Classification of hypervascularized lesions in CE MR imaging of the breast.

    abstract::The purpose of this paper is to define and evaluate a classification category for contrast-enhanced (CE) MR imaging of the breast based on the BI-RADS mammographic categories of the American College of Radiology. Using five evaluation criteria for MR findings (initial signal increase, post-initial signal behavior, sha...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1213-1

    authors: Baum F,Fischer U,Vosshenrich R,Grabbe E

    更新日期:2002-05-01 00:00:00

  • The prognostic value of late gadolinium enhancement in heart diseases: an umbrella review of meta-analyses of observational studies.

    abstract:OBJECTIVES:Cardiac magnetic resonance imaging (CMR) has proven itself as an accurate and robust diagnostic approach and has been widely used in the detection of various heart diseases. An increasing number of studies focusing more on the prognostic aspect of LGE-CMR arose in recent years, contributing to the redundant ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-07437-w

    authors: Dang Y,Hou Y

    更新日期:2021-01-07 00:00:00

  • Diagnostic utility of an echo-contrast agent in patients with synovitis using power Doppler ultrasound: a preliminary study with comparison to contrast-enhanced MRI.

    abstract::The purpose of this study was to first evaluate Levovist (Schering, Berlin, Germany), an echo-contrast agent, during power Doppler sonography (PDS) in patients with synovitis using asymptomatic joints as controls. Then we evaluated the accuracy of this technique against contrast-enhanced MRI. Forty patients (19 men an...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s003300000650

    authors: Magarelli N,Guglielmi G,Di Matteo L,Tartaro A,Mattei PA,Bonomo L

    更新日期:2001-01-01 00:00:00

  • TACE with degradable starch microspheres (DSM-TACE) as second-line treatment in HCC patients dismissing or ineligible for sorafenib.

    abstract:OBJECTIVES:To date, there is no approved second-line treatment for patients dismissing sorafenib or ineligible for this treatment, so it would be useful to find an effective alternative treatment option. The aim of our study was to evaluate safety, feasibility and effectiveness of transarterial chemoembolisation with d...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5692-8

    authors: Iezzi R,Pompili M,Rinninella E,Annicchiarico E,Garcovich M,Cerrito L,Ponziani F,De Gaetano A,Siciliano M,Basso M,Zocco MA,Rapaccini G,Posa A,Carchesio F,Biolato M,Giuliante F,Gasbarrini A,Manfredi R,HepatoCatt Study G

    更新日期:2019-03-01 00:00:00

  • Clinical and ultrasound features of segmental testicular infarction: six-year experience from a single centre.

    abstract::The purpose was to analyse the aetiology and ultrasound appearances of segmental testicular infarction. Patients with focal testicular lesions underwent colour Doppler high frequency ultrasound. Segmental testicular infarction was defined as any focal area of altered reflectivity, with or without focal enlargement wit...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0674-2

    authors: Bilagi P,Sriprasad S,Clarke JL,Sellars ME,Muir GH,Sidhu PS

    更新日期:2007-11-01 00:00:00

  • Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    abstract:OBJECTIVE:To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. METHODS:One hundred and sixty patients were randomly divided into two sc...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4349-8

    authors: Lv P,Liu J,Chai Y,Yan X,Gao J,Dong J

    更新日期:2017-01-01 00:00:00

  • Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality.

    abstract:OBJECTIVES:The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. METHODS:An 80 kVp TB protocol for CTCA and CTPA was retros...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3281-z

    authors: Rodrigues JC,Joshi D,Lyen SM,Negus IS,Manghat NE,Hamilton MC

    更新日期:2014-10-01 00:00:00

  • Cortical cerebral blood flow in ageing: effects of haematocrit, sex, ethnicity and diabetes.

    abstract:OBJECTIVES:Cerebral blood flow (CBF) estimates from arterial spin labelling (ASL) show unexplained variability in older populations. We studied the impact of variation of haematocrit (Hct) on CBF estimates in a tri-ethnic elderly population. MATERIALS AND METHODS:Approval for the study was obtained from the Fulham Res...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06096-w

    authors: Smith LA,Melbourne A,Owen D,Cardoso MJ,Sudre CH,Tillin T,Sokolska M,Atkinson D,Chaturvedi N,Ourselin S,Hughes AD,Barkhof F,Jäger HR

    更新日期:2019-10-01 00:00:00

  • Benign versus metastatic vertebral compression fractures: combined diffusion-weighted MRI and MR spectroscopy aids differentiation.

    abstract:OBJECTIVES:To determine the residual lipid fraction in fractured vertebrae by (1)H MR spectroscopy (MRS) and its confounding effect on differentiating benign from metastatic compression fractures of the spine using apparent diffusion coefficient (ADC) obtained by diffusion-weighted read-out-segmented echo-planar imagin...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2620-1

    authors: Rumpel H,Chong Y,Porter DA,Chan LL

    更新日期:2013-02-01 00:00:00

  • Acute obstruction of the renal collecting system: the intrarenal resistive index is a useful yet time-dependent parameter for diagnosis.

    abstract::The aim of this study was to determine whether the intrarenal resistive index (RI) can be used for the diagnosis of acute obstruction in patients with renal colic and to determine whether the index is time-related. Seventy patients referred to the Emergency Department with acute renal colic and without known associate...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050568

    authors: Opdenakker L,Oyen R,Vervloessem I,Goethuys H,Baert AL,Baert LV,Marchal G

    更新日期:1998-01-01 00:00:00

  • Foreign body extraction from soft tissue by using CT and fluoroscopic guidance: a new technique.

    abstract::We report on a new minimally invasive technique for the retrieval of a surgical pin fragment after accidental migration into the soft tissue of the shoulder in two patients. The technique is performed under local anaesthesia and uses combined CT and fluoroscopic guidance. The materials used were simple, combining a bo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1499-y

    authors: Amoretti N,Hauger O,Marcy PY,Hovorka I,Lesbats-Jacquot V,Fonquerne ME,Maratos Y,Boileau P

    更新日期:2010-01-01 00:00:00

  • Detection of hepatocellular carcinoma: comparison of ferumoxides-enhanced and gadolinium-enhanced dynamic three-dimensional volume interpolated breath-hold MR imaging.

    abstract::The purpose was to compare the diagnostic accuracy of ferumoxides-enhanced MR imaging and gadolinium-enhanced dynamic MR imaging using three-dimensional (3D) volume interpolated breath-hold examination (VIBE) for the detection of hepatocellular carcinoma (HCC). Forty-nine patients with 61 HCCs, who underwent ferumoxid...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2508-9

    authors: Kwak HS,Lee JM,Kim YK,Lee YH,Kim CS

    更新日期:2005-01-01 00:00:00

  • The RETAIN project: DICOM teleradiology over an ATM-based network. Radiological Examinations Transfer on an ATM Integrated Network.

    abstract::The RETAIN project (Radiological Examinations Transfer on an ATM Integrated Network) has aimed at testing videoconferencing and DICOM image transfers to get advice about difficult radiological cases over an asynchronous transfer mode (ATM)-based network, which affords a more comfortable interface than narrow-band netw...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050029

    authors: Heautot JF,Eichelberg M,Gibaud B,Tréguier C,Lemoine D,Scarabin JM,Piqueras J,Carsin M,Gandon Y

    更新日期:2000-01-01 00:00:00

  • Accuracy of single-energy quantitative computed tomography in the assessment of bone mineral density of cervical vertebrae.

    abstract::Earlier studies have shown that single-energy quantitative computed tomography (SEQCT) is a reliable method for bone mineral density (BMD) measurements in thoracic and lumbar vertebrae. Moreover, SEQCT has proved to be a useful parameter in the selection of appropriate implants in cervical spondylodesis. The aim of th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050312

    authors: Zink PM,Samii M,Luedemann W,Bellinzona M,Prokop M

    更新日期:1997-01-01 00:00:00

  • X-ray diagnostic without medical indication and bodily harm: decision of the Supreme Court of Germany 3/12/97--2StR 397/97.

    abstract::An orthopedic surgeon had been condemned for different offences to 2 years and 6 months imprisonment by the superior court in Frankfurt/Main. One point of the ruling had been the use of X-rays without medical indication, which the superior court of Frankfurt/Main finally did not assess as bodily harm. The supreme cour...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050748

    authors: Vogel M,Vogel H

    更新日期:1999-01-01 00:00:00

  • Intra-articular ganglion cysts of the cruciate ligaments.

    abstract::Intra-articular ganglion cysts of the cruciate ligaments are associated with non-specific clinical signs and symptoms. Familiarity with the MR appearances in particular is important to make an accurate diagnosis, exclude associated abnormalities, and avoid misdiagnosis. ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003309900290

    authors: Tyrrell PN,Cassar-Pullicino VN,McCall IW

    更新日期:2000-01-01 00:00:00

  • The correlation of mammographic-and histologic patterns of breast cancers in BRCA1 gene mutation carriers, compared to age-matched sporadic controls.

    abstract::Breast cancers in BRCA1 gene mutation carriers often have specific histologic features: grade III tumors with pushing margins. Our purpose was to compare the mammographic and histologic features of breast cancers in carriers with those in age-matched sporadic controls. The features of breast cancers in 27 BRCA1 carrie...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0385-0

    authors: Kaas R,Kroger R,Peterse JL,Hart AA,Muller SH

    更新日期:2006-12-01 00:00:00