A novel device for true lumen re-entry after subintimal recanalization of superficial femoral arteries: first-in-man experience and technical description.

Abstract:

:Subintimal angioplasty (SAP) is frequently performed for the treatment of critical limb ischemia (CLI) and has been recognized as an effective technique for these patients. Nevertheless, this approach is limited by the lack of controlled re-entry into the true lumen of the target vessel. We describe a novel device for true lumen re-entry after subintimal recanalization of superficial femoral arteries (SFA). We report our experience with six patients treated between April 2009 and January 2010 with a novel system designed to facilitate true lumen re-entry. The device was advanced by ipsilateral antegrade approach through a 6-French sheath. Successful reaccess into the true lumen was obtained in five of six patients without complications. The patient in whom the reaccess to the true lumen was not possible underwent successful bypass surgery. At 30 days follow-up, the SFA was patent in all patients according to echo-Doppler examination. Our preliminary experience indicates that this novel re-entry device increases the success rate of percutaneous revascularization of chronically occluded SFA.

authors

Airoldi F,Faglia E,Losa S,Tavano D,Latib A,Mantero M,Lanza G,Clerici G

doi

10.1007/s00270-010-9859-1

subject

Has Abstract

pub_date

2011-02-01 00:00:00

pages

166-9

issue

1

eissn

0174-1551

issn

1432-086X

journal_volume

34

pub_type

杂志文章
  • Hepatic arterial embolization and chemoembolization in the management of patients with large-volume liver metastases.

    abstract::The purpose of this study was to assess the role of hepatic arterial embolization (HAE) and chemoembolization (HACE) in patients with large-volume liver metastases. Patients with metastatic neuroendocrine tumors, melanomas, or gastrointestinal stromal tumors (GISTs) with >75% liver involvement who underwent HAE or HAC...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9186-3

    authors: Kamat PP,Gupta S,Ensor JE,Murthy R,Ahrar K,Madoff DC,Wallace MJ,Hicks ME

    更新日期:2008-03-01 00:00:00

  • An unusual left ventricular outflow pseudoaneurysm: usefulness of echocardiography and multidetector computed tomography for surgical repair.

    abstract::Left ventricular outflow tract (LVOT) pseudoaneurysm is a rare but potentially lethal complication, mainly after aortic root endocarditis or surgery. Usually it originates from a dehiscence in the mitral-aortic intervalvular fibrosa and it arises posteriorly to the aortic root. Due to these anatomical features, its im...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-008-9406-5

    authors: Da Col U,Ramoni E,Di Bella I,Ragni T

    更新日期:2009-01-01 00:00:00

  • Effect of Transcatheter Arterial Microembolization on Phantom Limb Pain Persisting for 17 Years.

    abstract::Phantom limb pain is a frequent consequence of the amputation; currently available treatments are far from satisfactory. The present report describes a case in which transcatheter arterial microembolization had a remarkable curative effect on phantom limb pain persisting for 17 years. The patient began feeling phantom...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-2109-7

    authors: Shibuya M,Yamamoto M,Okuno Y

    更新日期:2019-03-01 00:00:00

  • Malignant Hilar Biliary Obstruction: Treatment by Means of Placement of a Newly Designed Y-Shaped Branched Covered Stent.

    abstract:PURPOSE:To evaluate the technical feasibility and clinical efficacy of placement of a newly designed Y-shaped branched covered stent for palliative treatment of malignant hilar biliary obstruction. METHODS:From June 2011 to September 2014, 34 consecutive patients with malignant hilar biliary obstruction underwent perc...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1205-1

    authors: Yun JH,Jung GS,Park JG,Kang BC,Shin DH,Yun BC,Lee SU

    更新日期:2016-04-01 00:00:00

  • Ergotism presenting as restenosis following angioplasty.

    abstract::Ergotism may cause isolated lower-extremity arterial stenoses that appear amenable to angioplasty but that will recur if the causative agent is not withdrawn. A case of femoral-popliteal stenosis caused by surreptitious ergot ingestion is presented. The lesion initially responded to angioplasty but quickly recurred, w...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02583301

    authors: Keigley B,Vogelzang RL,Neiman HL,Conn JJ

    更新日期:1987-01-01 00:00:00

  • Successful Recanalization of a Complete Lobar Bronchial Stenosis in a Lung Transplant Patient Using a Combined Percutaneous and Bronchoscopic Approach.

    abstract::Airway stenosis is a major complication after lung transplantation that is usually managed with a combination of interventional endoscopic techniques, including endobronchial debridement, balloon dilation, and stent lacement. Herein, we report a successful case of recanalization of a complete stenosis of the right mid...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1219-8

    authors: Miraglia R,Vitulo P,Maruzzelli L,Burgio G,Caruso S,Bertani A,Callari A,Luca A

    更新日期:2016-03-01 00:00:00

  • Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheres.

    abstract:PURPOSE:To evaluate safety and efficacy of uterine artery embolization using narrow-size-range polyphosphazene-coated hydrogel microspheres (Embozene, CeloNova Biosciences, Newnan, GA). METHODS:Between May 2006 and September 2008, a total of 121 consecutive patients (mean ± SD age 42.1 ± 5.4 years, range 30.5-51.5 yea...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9986-8

    authors: Stampfl U,Radeleff B,Sommer C,Stampfl S,Dahlke A,Bellemann N,Kauczor HU,Richter GM

    更新日期:2011-04-01 00:00:00

  • Percutaneous Lung Tumor Biopsy Under CBCT Guidance with PET-CT Fusion Imaging: Preliminary Experience.

    abstract:PURPOSE:The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. MATERIALS AND METHODS:Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02270-1

    authors: Floridi C,Carnevale A,Fumarola EM,Schampaert S,Fontana F,De Palma D,Del Sole A,Giganti M,Carrafiello G

    更新日期:2019-11-01 00:00:00

  • Histopathological and Bacteriological Analysis of Thrombus Material Extracted During Mechanical Thrombectomy in Acute Stroke Patients.

    abstract:PURPOSE:Management of stroke secondary to septic emboli (SE) remains challenging, due to both the lack of specific recommendations and the gravity of the underlying pathology.The aim of this study is to describe the presence of SE in a series of mechanical thrombectomies (MT), analyzing technical complexity and outcome...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1718-x

    authors: Hernández-Fernández F,Rojas-Bartolomé L,García-García J,Ayo-Martín Ó,Molina-Nuevo JD,Barbella-Aponte RA,Serrano-Heras G,Juliá-Molla E,Pedrosa-Jiménez MJ,Segura T

    更新日期:2017-12-01 00:00:00

  • Adrenal radiofrequency ablation in swine: change in blood pressure and histopathologic analysis.

    abstract:PURPOSE:To evaluate changes in blood pressure during adrenal radiofrequency ablation (RFA) and analyze histopathologic outcomes in swine adrenal glands. MATERIALS AND METHODS:Animal Care Committee approval was obtained for this study. After laparotomy, a single adrenal gland was ablated from each of six animals (six R...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-0078-6

    authors: Yamakado K,Takaki H,Uchida K,Nakatsuka A,Shiraishi T,Takeda K

    更新日期:2011-08-01 00:00:00

  • Hepatocellular carcinoma: efficacy of transcatheter oily chemoembolization in relation to macroscopic and microscopic patterns of tumor growth among 100 patients with partial hepatectomy.

    abstract:PURPOSE:To evaluate the efficacy of transcatheter oily chemoembolization (TOCE) for hepatocellular carcinoma (HCC) on the basis of microscopic and macroscopic findings postembolization. METHODS:HCCs ranging in size from 0.5 to 13 cm (mean 3.6 cm) were obtained from partial hepatectomies of 100 consecutive patients who...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02807227

    authors: Hashimoto T,Nakamura H,Hori S,Tomoda K,Nakanishi K,Murakami T,Kozuka T,Monden M,Gotoh M,Kuroda C

    更新日期:1995-03-01 00:00:00

  • Long-Term Efficacy of Percutaneous Internal Plastic Stent Placement for Non-anastomotic Biliary Stenosis After Liver Transplantation.

    abstract:PURPOSE:We aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents. MATERIALS AND METHODS:This study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34-68) in 33 patients who neede...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1297-2

    authors: Lee ES,Han JK,Baek JH,Suh SW,Joo I,Yi NJ,Lee KW,Suh KS

    更新日期:2016-06-01 00:00:00

  • Temporary arterial embolization of liver parenchyma with degradable starch microspheres (EmboCept®S) in a swine model.

    abstract:BACKGROUND:This study aimed to evaluate the embolic properties, time to reperfusion, and histologic changes in temporary embolization of liver tissue with degradable starch microspheres (DSM) in a swine model. METHODS:In four adult minipigs, DSMs were injected into the right or left hepatic artery on the lobar level u...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0966-2

    authors: Pieper CC,Meyer C,Vollmar B,Hauenstein K,Schild HH,Wilhelm KE

    更新日期:2015-04-01 00:00:00

  • Use of a snare wire to perform nephrostomy access in the presence of obstructive staghorn calculi.

    abstract::We describe a technique for gaining access to the central collecting system via a chosen calyx, utilizing an alternative entry point to that calyx. An Amplatz nitinol loop snare is then used to convert this access to a traditional approach. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:

    authors: Nosher JL,Siegel RL,Bodner LJ

    更新日期:1996-05-01 00:00:00

  • Palliation of esophageal cancer with a double-layered covered nitinol stent: long-term outcomes and predictors of stent migration and patient survival.

    abstract:PURPOSE:To evaluate the long-term clinical outcomes and the negative predictors after the deployment of double-layered stents in malignant esophageal strictures. METHODS:This is a single-center study of patients who received a double-layered covered stent for the palliation of dysphagia due to malignant esophageal str...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0829-2

    authors: Mezes P,Krokidis ME,Katsanos K,Spiliopoulos S,Sabharwal T,Adam A

    更新日期:2014-12-01 00:00:00

  • New "mesh basket" for percutaneous removal of wall-adherent thrombi in dialysis shunts.

    abstract::A new basket, developed for percutaneous removal of wall-adherent thrombi, was tested in model thrombosed hemodialysis shunts and clinically in two polytetrafluoroethylene grafts and one Brescia-Cimino shunt after recanalization by aspiration thrombectomy. The residual wall-adherent thrombus was removed by one or two ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02603029

    authors: Schmitz-Rode T,Bohndorf K,Günther RW

    更新日期:1993-01-01 00:00:00

  • Salvage Lymph-Node Percutaneous Cryoablation: Safety Profile and Oncologic Outcomes.

    abstract::Purpose To evaluate the technical feasibility and safety of percutaneous cryoablation (CA) for the treatment of single/oligometastatic lymph-node (LN) relapse in different anatomic regions. MATERIALS AND METHODS:This is a retrospective study of all patients who underwent percutaneous CA of LN metastases (May 2014-Apr...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02341-3

    authors: Tsoumakidou G,Mandralis K,Hocquelet A,Duran R,Denys A

    更新日期:2020-02-01 00:00:00

  • Modified PAIR technique for percutaneous treatment of high-risk hydatid cysts.

    abstract:PURPOSE:This paper presents a modification of the known method for percutaneous treatment of hydatid cyst, the PAIR technique. It aimed to achieve safe aspiration of large symptomatic cysts and cysts with a danger of impending rupture. METHODS:We designed a coaxial catheter system to achieve concomitant evacuation of ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/pl00021047

    authors: Gabal AM,Khawaja FI,Mohammad GA

    更新日期:2005-03-01 00:00:00

  • Nuclear magnetic resonance of the brain.

    abstract::Recent developments in MRI of the brain are reviewed. Over the past year there has been a general improvement in image quality, a paramagnetic contrast agent has been used in clinical practice, and surface coils have been used more generally in imaging. A wider range of disease has been studied, and there has been con...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552362

    authors: Bydder GM

    更新日期:1986-01-01 00:00:00

  • Curved Needles in CT-Guided Fine Needle Biopsies of Abdominal and Retroperitoneal Small Lesions.

    abstract:PURPOSE:To demonstrate the advantages of using curved needles in fine needle aspiration (FNA) with CT-guided, for analyzing abdominal and/or retroperitoneal small lesions which are impossible to reach with conventional non-surgical biopsy techniques, particularly in cases in which the cytology sample was not possible t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1107-2

    authors: De Filippo M,Saba L,Rossi E,Nizzoli R,Tiseo M,Pedrazzi G,Brunese L,Rotondo A,Rossi C

    更新日期:2015-12-01 00:00:00

  • Successful treatment with a covered stent and 6-year follow-up of biliary complication after liver transplantation.

    abstract::The role of covered stent in the management of biliary complications is not yet defined in liver transplant recipients. This Case Report presents a patient with anastomotic stricture and leakage with biloma treated with a covered stent 32 months following liver transplantation. Signs of in-stent restenosis developed 5...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9558-y

    authors: Doros A,Németh A,Deák AP,Hartmann E,Gerlei Z,Fazakas J,Kóbori L

    更新日期:2010-04-01 00:00:00

  • A system for computer-assisted design of stent-grafts for aortic aneurysms using 3-D morphological models.

    abstract::A three-dimensional model was constructed from helical CT images for abdominal aortic aneurysm (AAA) and thoracic aortic aneurysm (TAA). A stent-graft was designed and positioned endoluminally on the computer. One hundred and nine stent-grafts for 101 patients were designed by this method and deployed well in all pati...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-001-0383-8

    authors: Imai Y,Urayama S,Uyama C,Inoue K,Ueno K,Kuribayashi S,Takamiya M,Hamada S,Hirane Y

    更新日期:2001-07-01 00:00:00

  • Results of a seven-year, single-centre experience of the long-term outcomes of bovine ureter grafts used as novel conduits for haemodialysis fistulas.

    abstract:PURPOSE:To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. MATERIALS AND METHODS:Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa(®), Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0096-z

    authors: Das N,Bratby MJ,Shrivastava V,Cornall AJ,Darby CR,Boardman P,Anthony S,Uberoi R

    更新日期:2011-10-01 00:00:00

  • First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    abstract::The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter place...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-008-9483-5

    authors: Kos S,Huegli R,Hofmann E,Quick HH,Kuehl H,Aker S,Kaiser GM,Borm PJ,Jacob AL,Bilecen D

    更新日期:2009-05-01 00:00:00

  • Looking for the ideal particle: an experimental embolization study.

    abstract::This study sought to compare the most frequently used embolic particles in an animal model. In 16 New Zealand white rabbits, right renal arteries were embolized using four different embolic particles (polyvinyl alcohol [PVA] particles, 150-250 microm; PVA microspheres [PVAMs], 150-300 microm; Tris-acryl gelatin micros...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9747-8

    authors: Senturk C,Cakir V,Yorukoglu K,Yilmaz O,Goktay AY

    更新日期:2010-04-01 00:00:00

  • Transnasal Snare Technique for Retrograde Primary Jejunostomy Placement After Surgical Gastrojejunostomy.

    abstract:PURPOSE:To report a transnasal snare technique for retrograde primary jejunostomy placement after surgical gastrojejunostomy. MATERIALS AND METHODS:Two patients underwent the transnasal snare technique for retrograde primary jejunostomy placement. Patients included two females, age 58 and 62. In both patients, a goose...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1777-z

    authors: Srinivasa RN,Chick JFB,Hage AN,Shields JJ,Saad WE,Majdalany BS,Srinivasa RN

    更新日期:2017-12-01 00:00:00

  • A rare case of iatrogenic pseudoaneurysm of the left brachiocephalic vein after central venous catheterization treated with thrombin injection.

    abstract::Rupture of the central veins with venous pseudoaneurysm formation is an unusual complication of central venous catheterization. Only seven cases of brachiocephalic venous pseudoaneurysm have been reported in the literature (among these only one was secondary to central venous catheterization). Plain radiographic exami...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0729-5

    authors: Elsaadany AM,Alaeddin FH,Alsuhaibani HA

    更新日期:2014-08-01 00:00:00

  • Present status of axially angled angiocardiography.

    abstract::Axial angiography visualizes anatomical details of normal and pathological hearts not previously demonstrated by conventional angiography. Progress in the diagnosis of congenital heart malformations using axial projection technique has been reconsidered, emphasizing that the anatomical details of each congenital heart...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552817

    authors: Soto B,Coghlan CH,Bargeron LM

    更新日期:1984-01-01 00:00:00

  • In vitro evaluation of caval filters.

    abstract::This experiment demonstrated the clottrapping ability of two commercially available filters, the Mobin-Uddin and Greenfield, and three experimental filters developed by Amplatz, Günther, and Gianturco. Each filter was tested in a polyethylene tube simulating the inferior vena cava. Separate series of 10 clots, each 3 ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577413

    authors: Robinson JD,Madison MT,Hunter DW,Castaneda-Zuniga WR,Amplatz K

    更新日期:1988-12-01 00:00:00

  • Relief of mesenteric ischemia by Z-stent placement into the superior mesenteric artery compressed by the false lumen of an aortic dissection.

    abstract::In a 58-year-old man acute aortic dissection compromised the origin of the superior mesenteric artery (SMA), resulting in mesenteric ischemia. After failed balloon angioplasty a Gianturco Z-stent was placed. The stenosis improved immediately, followed by resolution of the clinical signs of mesenteric ischemia. SMA flo...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900214

    authors: Yamakado K,Takeda K,Nomura Y,Kato N,Hirano T,Matsumura K,Nakagawa T,Yuasa H,Yada I

    更新日期:1998-01-01 00:00:00