First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

Abstract:

:The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

authors

Kos S,Huegli R,Hofmann E,Quick HH,Kuehl H,Aker S,Kaiser GM,Borm PJ,Jacob AL,Bilecen D

doi

10.1007/s00270-008-9483-5

subject

Has Abstract

pub_date

2009-05-01 00:00:00

pages

514-21

issue

3

eissn

0174-1551

issn

1432-086X

journal_volume

32

pub_type

杂志文章
  • Oscillating probe aspiration thrombectomy: comparative in vitro evaluation of two concepts.

    abstract::Aspiration thrombectomy supported by an oscillating metal probe within the catheter allows continuous aspiration of large thrombi without catheter obstruction. Thrombus aspiration assisted by an ultrasound-driven probe (frequency 26 kHz) and by an electric motor-driven probe (frequency 40 Hz) was compared in two diffe...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02735577

    authors: Schmitz-Rode T,Günther RW

    更新日期:1992-05-01 00:00:00

  • General theory of predictive dosimetry for yttrium-90 radioembolization to sites other than the liver.

    abstract::Modern advances in interventional radiology and nuclear medicine may now allow for safe and effective 90Y radioembolization to sites other than the liver. A general theory of predictive dosimetry based on the MIRD schema is proposed, adapted from the original partition model for liver 90Y radioembolization. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 评论,信件

    doi:10.1007/s00270-013-0783-z

    authors: Kao YH

    更新日期:2014-08-01 00:00:00

  • Two cases of spontaneous lysis of arterial thrombi.

    abstract::Two cases of spontaneous lysis of arterial thrombi are described. The occurrence of spontaneous thrombolysis and the relative ease of performing Fogarty embolectomy (thrombectomy) in peripheral arteries should be considered along with the clinical status of a patient who is viewed as a possible candidate for thromboly...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552672

    authors: Weiner MA,Sniderman KW,Sos TA,Saddekni S,Silane M

    更新日期:1984-01-01 00:00:00

  • Iodine-125 seeds strand for treatment of tumor thrombus in inferior vena cava: an experimental study in a rabbit model.

    abstract:OBJECTIVE:The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. METHODS:Tumor cell line VX2 was inoculated subcutaneously into New Zealand rabbit to develop the parent t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0628-9

    authors: Zhang W,Yan Z,Luo J,Fang Z,Wu L,Liu Q,Qu X,Liu L,Wang J

    更新日期:2013-10-01 00:00:00

  • Analysis of particle size generated during plaque ablation with a flashlamp pumped pulsed dye laser.

    abstract:PURPOSE:To examine debris size generated during in vitro plaque ablation by laser energy and estimate the risk of peripheral embolization following laser angioplasty. METHODS:A flashlamp pumped pulsed dye laser of 480-nm wavelength was used to ablate calcified arteriosclerotic plaque, fibrous fatty plaque, and normal ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02807353

    authors: Froelich JJ,Möckel JW,Azumi N,Barth KH

    更新日期:1995-01-01 00:00:00

  • Acute thrombocytopenia: an unusual complication occurring after drug-eluting microspheres transcatheter hepatic chemoembolization.

    abstract::Image-guided transcatheter hepatic chemoembolization (TACE) is accepted worldwide as an effective treatment for patients with unresectable hepatocellular carcinoma and liver metastases from neuroendocrine tumors, colorectal carcinomas, and uveal melanomas. Although the technique is relatively safe, it has been associa...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9983-y

    authors: Poggi G,Quaretti P,Montagna B,Sottotetti F,Tagliaferri B,Pozzi E,Amatu A,Pagella C,Bernardo G

    更新日期:2011-02-01 00:00:00

  • Catheter-directed thrombolysis with percutaneous rheolytic thrombectomy versus thrombolysis alone in upper and lower extremity deep vein thrombosis.

    abstract:PURPOSE:To compare the efficacy of catheter-directed thrombolysis (CDT) alone versus CDT with rheolytic percutaneous mechanical thrombectomy (PMT) for upper and lower extremity deep vein thrombosis (DVT). METHODS:A retrospective cohort of consecutive patients with acute iliofemoral or brachiosubclavian DVT treated wit...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0341-4

    authors: Kim HS,Patra A,Paxton BE,Khan J,Streiff MB

    更新日期:2006-11-01 00:00:00

  • Driven around the bend: novel use of a curved steerable needle.

    abstract:PURPOSE:This technical note describes the novel use of a curved, steerable needle to access symptomatic osseous lesions in the pelvis and sacrum for palliative percutaneous treatment that would otherwise be difficult to treat using conventional straight needles. MATERIALS AND METHODS:Seven patients with lytic bone les...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0482-1

    authors: Murphy DT,Korzan JR,Ouellette HA,Liu DM,Clarkson PW,Munk PL

    更新日期:2013-04-01 00:00:00

  • Routine use of three-dimensional contrast-enhanced moving-table MR angiography in patients with peripheral arterial occlusive disease: comparison with selective digital subtraction angiography.

    abstract:PURPOSE:To compare the diagnostic accuracy of contrast-enhanced (CE) three-dimensional (3D) moving-table magnetic resonance (MR) angiography with that of selective digital subtraction angiography (DSA) for routine clinical investigation in patients with peripheral arterial occlusive disease. METHODS:Thirty-eight patie...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0309-9

    authors: Deutschmann HA,Schoellnast H,Portugaller HR,Preidler KW,Reittner P,Tillich M,Pilger E,Szolar DH

    更新日期:2006-09-01 00:00:00

  • Isolated right segmental hepatic duct injury following laparoscopic cholecystectomy.

    abstract:PURPOSE:Laparoscopic cholecystectomy (LC) is the treatment of choice for gallstones. There is an increased incidence of bile duct injuries in LC compared with the open technique. Isolated right segmental hepatic duct injury (IRSHDI) represents a challenge not only for management but also for diagnosis. We present our e...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-2678-5

    authors: Perini RF,Uflacker R,Cunningham JT,Selby JB,Adams D

    更新日期:2005-03-01 00:00:00

  • Massive hemoptysis from pulmonary artery pseudoaneurysm caused by lung radiofrequency ablation: successful treatment by coil embolization.

    abstract::A 75-year-old man received lung radiofrequency (RF) ablation to treat lung metastases from hepatocellular carcinoma. Massive hemoptysis occurred 1 week after lung RF ablation. Emergent contrast-enhanced CT and pulmonary arteriography revealed a pulmonary artery pseudoaneurysm, which was embolized with coils. The poste...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9564-0

    authors: Yamakado K,Takaki H,Takao M,Murashima S,Kodama H,Kashima M,Nakatsuka A,Uraki J,Shimpo H,Takeda K

    更新日期:2010-04-01 00:00:00

  • Successful Balloon-Assisted Hepatic Tract Embolization Using the Pull-Through Technique to Remove a Malpositioned Chest Tube Penetrating the Liver and into the Right Ventricle.

    abstract::Intra-abdominal injury is an uncommon complication of chest tube insertion. A 66-year-old man had empyema and underwent chest tube insertion for drainage. Massive hemorrhage occurred; the postprocedural radiograph showed the malpositioned chest tube in the mediastinum. Computed tomography scan showed that the tube's t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-1974-4

    authors: Hamanaka K,Hirokawa Y,Itoh T,Yamasaki M,Hayashi K,Sawai S,Nishiyama K

    更新日期:2018-09-01 00:00:00

  • Embolic control of lumbar artery hemorrhage complicating percutaneous renal biopsy with a 3-F coaxial catheter system: case report.

    abstract::A case is presented in which massive retroperitoneal hemorrhage from the left first lumbar artery complicating a percutaneous renal biopsy was successfully controlled by superselective embolization with microcoils. An anterior radiculomedullary artery (artery of Adamkiewicz) originated from the lumbar artery. To minim...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577724

    authors: Kim KT,Kim BS,Park YH,Cho KJ,Shinn KS,Bahk YW

    更新日期:1991-05-01 00:00:00

  • Benign Metastasizing Leiomyomas Following Myomectomy and Uterine Artery Embolization.

    abstract::Benign metastasizing leiomyomas (BMLs) are rare sequelae of common uterine leiomyomas and most frequently found in the lungs. Most cases of BMLs occur with a history of prior gynecologic procedures; however, none have yet been reported in association with uterine artery embolization (UAE). This case report highlights ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1696-z

    authors: Yoon J,Spies JB,Caridi TM

    更新日期:2017-11-01 00:00:00

  • JAG tearing technique with radiofrequency guide wire for aortic fenestration in thoracic endovascular aneurysm repair.

    abstract::An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided i...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0267-y

    authors: Ricci C,Ceccherini C,Leonini S,Cini M,Vigni F,Neri E,Tucci E,Benvenuti A,Tommasino G,Sassi C

    更新日期:2012-02-01 00:00:00

  • Phase II feasibility study on the combination of two different regional treatment approaches in patients with colorectal "liver-only" metastases: hepatic interstitial brachytherapy plus regional chemotherapy.

    abstract::The aim of this study was to evaluate the feasibility, safety, and efficacy of combined treatment with hepatic interstitial brachytherapy (HIB) and hepatic arterial infusion (HAI) of chemotherapy after interventional implantation of port catheter systems. Thirty-three patients with unresectable "liver-only" metastases...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9597-4

    authors: Wieners G,Pech M,Hildebrandt B,Peters N,Nicolaou A,Mohnike K,Seidensticker M,Sawicki M,Wust P,Ricke J

    更新日期:2009-09-01 00:00:00

  • Endovascular stent-graft applications in latrogenic vascular injuries.

    abstract:PURPOSE:To report the results of covered stent applications in iatrogenic vascular injuries. METHODS:We report 17 patients (11 men, 6 women; age range 20-59 years, mean age 40 years) who underwent repair of different iatrogenic vascular lesions by means of endovascular covered stents. The patient population consisted ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0038-5

    authors: Baltacioğlu F,Cimşit NC,Cil B,Cekirge S,Ispir S

    更新日期:2003-09-01 00:00:00

  • Acute Thrombus Burden on Coated Flow Diverters Assessed by High Frequency Optical Coherence Tomography.

    abstract:PURPOSE:The implantation of flow diverters requires administration of dual anti-platelet therapy, posing the potential for complications. The p48MW HPC (phenox, Bochüm, Germany) hydrophilic-coated flow diverting stent is designed to be anti-thrombotic, thus opening the potential for single anti-platelet therapy. We dep...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02482-w

    authors: King RM,Langan ET,Ughi GJ,Raskett CM,Puri AS,Henkes H,Gounis MJ

    更新日期:2020-08-01 00:00:00

  • Triple catheter aortoiliac angioplasty in a patient with a horseshoe kidney: technical note.

    abstract::A method is described for protecting a nonstenotic anomalous artery to the left-lower pole of a horseshoe kidney that originated from a stenotic left common iliac artery. Using a triple catheter technique, injury to this anomalous renal artery was prevented while using "kissing balloons" to dilate bilateral proximal c...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02575433

    authors: Matsumoto AH,Baum PA,Barth KH,Teitelbaum GP

    更新日期:1989-11-01 00:00:00

  • Novel percutaneous radiofrequency ablation of portal vein tumor thrombus: safety and feasibility.

    abstract:PURPOSE:We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. METHODS:Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0451-8

    authors: Mizandari M,Ao G,Zhang Y,Feng X,Shen Q,Chen M,Lau W,Nicholls J,Jiao L,Habib N

    更新日期:2013-02-01 00:00:00

  • Metallic stents for the treatment of biliary obstruction: a report of 100 cases.

    abstract::The results of the first 100 patients to receive Gianturco-Rösch "Z" stents is presented along with recommendations for their use. The patient population was comprised of 57 men and 43 women, age range 17-85 years (mean 65 years). Fifty-four of the patients had benign obstruction and 46 had malignant obstruction. Of t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02734120

    authors: Coons H

    更新日期:1992-11-01 00:00:00

  • Expandable metallic stent treatment for malignant colorectal strictures.

    abstract::Four patients were treated by placement of an expandable metallic stent (two Gianturco Z-stents, two Ultraflex stents) for malignant colorectal strictures. All four patients were able to defecate after stent placement. Stent migration was recognized in one patient. Two patients suffered from tenesmus after stent place...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900355

    authors: Mishima K,Sawada S,Tanigawa N,Okuda Y,Kobayashi M,Koyama T

    更新日期:1999-03-01 00:00:00

  • Total anomalous pulmonary venous connection to the portal vein.

    abstract::Anomalous pulmonary venous return represents a rare congenital anomaly with wide anatomic and physiologic variability. We report a case of the newborn with a rare form of total infracardiac anomalous pulmonary venous connection (TAPVC). The pulmonary veins draining both lungs formed two vertical veins, which joined to...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02563905

    authors: Wyttenbach M,Carrel T,Schüpbach P,Tschäppeler H,Triller J

    更新日期:1996-03-01 00:00:00

  • Endovascular treatment of autogenous radiocephalic fistulas with the "eighth note" deformity for hemodialysis.

    abstract::The purpose of this paper is to describe a unique "eighth note" deformity of the autogenous radiocephalic fistula for hemodialysis and to retrospectively evaluate the efficacy and safety of its endovascular treatment. Over 3 years, a total of 808 patients and 558 autogenous radiocephalic fistulas were treated for vasc...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9639-y

    authors: Weng MJ,Chen MC,Chi WC,Liu YC,Chien KF,Liang HL,Pan HB

    更新日期:2010-02-01 00:00:00

  • Failed retrieval of potentially retrievable IVC filters: a report of two cases.

    abstract::Retrievable inferior vena cava filters are being increasingly used for the prevention of life-threatening pulmonary emboli in patients who have temporary contraindications to anticoagulation therapy. We report two cases of failure to remove these devices. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0145-6

    authors: Kumar BC,Chakraverty S,Zealley I

    更新日期:2006-01-01 00:00:00

  • Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor.

    abstract::A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1160-x

    authors: Panizza PS,de Albuquerque Cavalcanti CF,Yamaguchi NH,Leite CC,Cerri GG,de Menezes MR

    更新日期:2016-02-01 00:00:00

  • Treatment of acute lower limb ischemia following the use of the Duett sealing device: report of three cases and review of the literature.

    abstract::Three cases of local thrombolysis in the treatment of acute lower limb ischemia complicating the utilization of the Duett sealing device are presented. Routine usage of several vascular closure devices after cardiac catheterization and percutaneous coronary intervention (PCI) has been adopted in our institution during...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0155-1

    authors: Katsouras CS,Michalis LK,Leontaridis I,Kolettis T,Naka KK,Goudevenos JA,Rees MR,Sideris DA

    更新日期:2004-05-01 00:00:00

  • Embolization of acute nonvariceal upper gastrointestinal hemorrhage resistant to endoscopic treatment: results and predictors of recurrent bleeding.

    abstract::Acute nonvariceal upper gastrointestinal (UGI) hemorrhage is a frequent complication associated with significant morbidity and mortality. The most common cause of UGI bleeding is peptic ulcer disease, but the differential diagnosis is diverse and includes tumors; ischemia; gastritis; arteriovenous malformations, such ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-010-9829-7

    authors: Loffroy R,Rao P,Ota S,De Lin M,Kwak BK,Geschwind JF

    更新日期:2010-12-01 00:00:00

  • Pulmonary Thermal Ablation Enables Long Chemotherapy-Free Survival in Metastatic Colorectal Cancer Patients.

    abstract:BACKGROUND:Chemotherapy (ct) is the preferred treatment option in metastatic colorectal cancer (mCRC). The objective of the study was to determine the overall survival (OS), disease-free survival (DFS) and ct-free survival (CFS) of pulmonary thermal ablation (TA) and its place in the treatment of mCRC. PATIENTS AND ME...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-1939-7

    authors: Fonck M,Perez JT,Catena V,Becouarn Y,Cany L,Brudieux E,Vayre L,Texereau P,Le Brun-Ly V,Verger V,Brouste V,Bechade D,Buy X,Palussière J

    更新日期:2018-11-01 00:00:00

  • Retrieval of an embolization coil from the internal carotid artery using the Amplatz microsnare retrieval system.

    abstract::An unusual case of unintentional release of an embolization coil into the proximal internal carotid artery is reported. The coil migrated and lodged distally in the petrous portion of the internal carotid artery during initial removal attempts using a regular nitinol loop snare. The coil was retrieved with the Amplatz...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF00239425

    authors: Cekirge S,Saatci I,Firat MM,Balkanci F

    更新日期:1995-07-01 00:00:00