Temporary arterial embolization of liver parenchyma with degradable starch microspheres (EmboCept®S) in a swine model.

Abstract:

BACKGROUND:This study aimed to evaluate the embolic properties, time to reperfusion, and histologic changes in temporary embolization of liver tissue with degradable starch microspheres (DSM) in a swine model. METHODS:In four adult minipigs, DSMs were injected into the right or left hepatic artery on the lobar level until complete stasis of the blood flow was detectable angiographically. The time required to complete angiographically determined reperfusion was noted. The animals were killed 3 h after complete reperfusion, and samples were taken from the liver. Histologic examinations of the embolized liver parenchyma and untreated tissue were performed. RESULTS:Hepatic arterial embolization using DSMs was technically successful in all cases, with complete blood flow stasis shown by control angiography. A single vial of DSMs (450 mg/7.5 ml) was sufficient to embolize a whole liver lobe in all cases. Angiography showed complete reconstitution of hepatic arterial perfusion after a mean time to reperfusion of 32 ± 6.1 min (range, 26-39 min). Hematoxylin and eosin staining showed no histologically detectable differences between untreated tissue and parenchyma embolized with DSMs except for mild sinusoidal congestion in one case. Indirect in situ DNA nick end labeling staining (TUNEL) showed only single positive hepatocytes, indicating apoptosis. CONCLUSION:Temporary embolization of the hepatic artery using DSMs is feasible with complete reperfusion after 30 min in pigs. Even after complete arterial blood flow stasis, no extensive tissue damage to the embolized liver parenchyma was observed at histologic examinations in this short-term study.

authors

Pieper CC,Meyer C,Vollmar B,Hauenstein K,Schild HH,Wilhelm KE

doi

10.1007/s00270-014-0966-2

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

435-41

issue

2

eissn

0174-1551

issn

1432-086X

journal_volume

38

pub_type

杂志文章
  • Cryoablation for Secondary Renal Cell Carcinoma After Surgical Nephrectomy.

    abstract:PURPOSE:To retrospectively evaluate the clinical outcomes of cryoablation for secondary renal cell carcinoma for patients with a history of nephrectomy for initial renal cell carcinoma. MATERIALS AND METHODS:Thirty patients with 40 renal tumors who had undergone a nephrectomy for initial renal cell carcinoma and cryoa...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02709-w

    authors: Ushijima Y,Asayama Y,Nishie A,Takayama Y,Kubo Y,Ishimatsu K,Ishigami K

    更新日期:2020-11-17 00:00:00

  • Transluminal penile venoablation for impotence: a progress report.

    abstract::Based on theoretical advantages and successful pilot experiments in dogs, therapeutic transluminal penile venoablation underwent clinical trials in 13 impotent men. Catheter access to the penile venous structures was gained via (1) direct percutaneous puncture of the deep dorsal penile vein, (2) cut-down over the dors...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577012

    authors: Bookstein JJ,Lurie AL

    更新日期:1988-08-01 00:00:00

  • High-Flow Vascular Malformation in the Sigmoid Mesentery Successfully Treated with a Combination of Transarterial and Transvenous Embolization.

    abstract::Mesenteric high-flow vascular malformation can cause various clinical symptoms and demand specific therapeutic interventions owing to its peculiar hemodynamics. We report a case of high-flow vascular malformation in the sigmoid mesentery which presented with ischemic colitis. The main trunk of the inferior mesenteric ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1431-1

    authors: Kamo M,Yagihashi K,Okamoto T,Nakamura K,Fujita Y,Kurihara Y

    更新日期:2016-12-01 00:00:00

  • The Influence of Preoperative Aneurysmal Thrombus Quantity and Distribution on the Development of Type II Endoleaks with Aneurysm Sac Enlargement After EVAR of AAA.

    abstract:PURPOSE:To determine the influence of preoperative aneurysmal thrombus quantity and distribution on the development of type II endoleak with aneurysm sac enlargement after endovascular aneurysm repair (EVAR). MATERIALS AND METHODS:We retrospectively analyzed the pre- and postoperatively performed CT scans of 118 patie...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1386-2

    authors: Müller-Wille R,Güntner O,Zeman F,Dollinger M,Hälg C,Beyer LP,Pfister K,Kasprzak P,Stroszczynski C,Wohlgemuth WA

    更新日期:2016-08-01 00:00:00

  • Factors limiting complete tumor ablation by radiofrequency ablation.

    abstract::The purpose of this study was to determine radiological or physical factors to predict the risk of residual mass or local recurrence of primary and secondary hepatic tumors treated by radiofrequency ablation (RFA). Eighty-two patients, with 146 lesions (80 hepatocellular carcinomas, 66 metastases), were treated by RFA...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9208-1

    authors: Paulet E,Aubé C,Pessaux P,Lebigot J,Lhermitte E,Oberti F,Ponthieux A,Calès P,Ridereau-Zins C,Pereira PL

    更新日期:2008-01-01 00:00:00

  • A comparison of three transarterial lipiodol-based formulations for hepatocellular carcinoma: in vivo biodistribution study in humans.

    abstract::This study aimed to evaluate and compare the biodistribution properties of three transarterial Lipiodol-based therapeutic regimens in human hepatocellular carcinoma (HCC). In this prospective study with 13 patients randomly allocated to one of three study groups, each of the patients received transcatheter intra-arter...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00270-007-9173-8

    authors: Yu SC,Leung TW,Lau WY,Lee N,Hui EP,Yeo W,Lai PB,Mok TS

    更新日期:2008-03-01 00:00:00

  • improved patency of transjugular intrahepatic portosystemic shunt: the efficacy of cilostazol for the prevention of pseudointimal hyperplasia in swine TIPS models.

    abstract:PURPOSE:To investigate the efficacy of oral administration of cilostazol to inhibit pseudointimal/intimal hyperplasia in swine TIPS models. METHODS:Successful TIPS creation was carried out in 11 of 12 healthy young pigs (20-25 kg). In the treatment group (n = 6), both cilostazol and aspirin were administered daily, fr...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9001-1

    authors: Park SW,Cha IH,Kim CH,Jeon HJ,Park JH,Hong SJ,Lee IS

    更新日期:2007-07-01 00:00:00

  • New Alcohol and Onyx Mixture for Embolization: Feasibility and Proof of Concept in Both In Vitro and In Vivo Models.

    abstract:INTRODUCTION:Onyx and ethanol are well-known embolic and sclerotic agents that are frequently used in embolization. These agents present advantages and disadvantages regarding visibility, injection control and penetration depth. Mixing both products might yield a new product with different characteristics. The aim of t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1559-z

    authors: Saeed Kilani M,Zehtabi F,Lerouge S,Soulez G,Bartoli JM,Vidal V,Badran MF

    更新日期:2017-05-01 00:00:00

  • Use of the TriSpan coil to facilitate the transcatheter occlusion of pulmonary arteriovenous malformation.

    abstract::Pulmonary arteriovenous malformation (PAVM) is a rare vascular malformation of the lung which may occur as an isolated entity or in association with hereditary hemorrhagic telangiectasia (HHT). Because of considerable risk of serious complications such as cerebral embolism, brain abscess and pulmonary hemorrhage, defi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0023-7

    authors: Cil BE,Erdogan C,Akmangit I,Cekirge S,Balkanci F

    更新日期:2004-11-01 00:00:00

  • Fluoroscopically guided feeding tube insertion for relief of postoperative gastrointestinal anastomotic obstruction and leakage.

    abstract:PURPOSE:To evaluate the feasibility and effectiveness of feeding tube insertion and enteral feeding for the treatment of postoperative gastrointestinal anastomotic obstruction and leakage. MATERIALS AND METHODS:From June 1999 to June 2002, thirty-four cases of postoperative gastrointestinal anastomotic obstruction and...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0095-z

    authors: Han YM,Kim CY,Yang DH,Kwak HS,Jin GY

    更新日期:2006-05-01 00:00:00

  • Acute coronary artery air embolism following CT-guided lung biopsy.

    abstract::CT-guided needle biopsy is a common procedure for obtaining a tissue diagnosis and consequently correctly managing patients. This procedure has many potential complications, ranging from simple pneumothorax or self-limiting hemoptysis to life-threatening pulmonary hemorrhage and air embolism. Though the latter is a ra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0118-1

    authors: Mansour A,AbdelRaouf S,Qandeel M,Swaidan M

    更新日期:2005-01-01 00:00:00

  • Embolization of large aneurysms with long wire coils.

    abstract::The authors report the experience of using long coils of 2 m length in the management of large aneurysms. Knowledge of the characteristics of these coils is of value for correct placement. These coils are safe and cost-effective for excluding large aneurysms. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-001-0046-2

    authors: Golzarian J,Dussaussois L,Ait Said K,Abada HT,Dereume JP,Struyven J

    更新日期:2002-01-01 00:00:00

  • 3D stereoscopic visualization of fenestrated stent grafts.

    abstract::The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were sele...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-008-9494-2

    authors: Sun Z,Squelch A,Bartlett A,Cunningham K,Lawrence-Brown M

    更新日期:2009-09-01 00:00:00

  • Dissection of the abdominal aorta in blunt trauma: management by percutaneous stent placement.

    abstract::We implanted stents in three patients who had traumatic abdominal aortic dissections, complicated by right limb ischemia in one case. The circulating false channel extended to the left iliac artery in one case and to both iliac arteries in the last case. Diagnosis and radiological follow-up included ultrasound, comput...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900197

    authors: Vernhet H,Marty-Ané CH,Lesnik A,Chircop R,Serres-Cousiné O,Picard E,Mary H,Senac JP

    更新日期:1997-11-01 00:00:00

  • Usefulness of Amplatzer Vascular Plug for Preoperative Embolization Before Distal Pancreatectomy with En Bloc Celiac Axis Resection.

    abstract:PURPOSE:We evaluated the usefulness of the Amplatzer vascular plug (AVP) for preoperative embolization before distal pancreatectomy with en bloc celiac axis resection (DP-CAR). MATERIALS AND METHODS:Between April 2010 and September 2017, 19 patients with locally advanced pancreatic body cancer underwent preoperative e...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02233-6

    authors: Fuji T,Yamagami T,Fukumoto W,Baba Y,Chosa K,Ishikawa M,Iida M,Naito A,Murakami Y,Uemura K,Kondo N,Awai K

    更新日期:2019-09-01 00:00:00

  • Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm.

    abstract::We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1161-9

    authors: Goltz JP,Loesaus J,Frydrychowicz A,Barkhausen J,Wiedner M

    更新日期:2016-02-01 00:00:00

  • Stereotactic Radiofrequency Ablation for Metastatic Melanoma to the Liver.

    abstract:PURPOSE:To evaluate the outcome of patients with melanoma liver metastasis treated with stereotactic radiofrequency ablation (SRFA). MATERIAL AND METHOD:Following IRB approval, a retrospective evaluation of the treatment of 20 patients with 75 melanoma liver metastases was performed. RESULTS:A median number of 2 lesi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1336-z

    authors: Bale R,Schullian P,Schmuth M,Widmann G,Jaschke W,Weinlich G

    更新日期:2016-08-01 00:00:00

  • Dialysis access graft thrombolysis: randomized study of pulse-spray versus continuous urokinase infusion.

    abstract:PURPOSE:To compare pulse-spray to continuous-infusion thrombolysis with high-dose urokinase in thrombosed dialysis access grafts. METHODS:A prospective randomized controlled trial was performed. From August 1992 to September 1993, 30 thrombosed polytetrafluoroethylene (PTFE) grafts in 24 patients were included, 15 gra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s002709900229

    authors: Goodwin SC,Arora LC,Razavi MK,Sayre J,McNamara TO,Yoon C

    更新日期:1998-03-01 00:00:00

  • A new balloon-expandable tantalum stent (Strecker-Stent) for the biliary system: preliminary experience.

    abstract::Placement of a balloon-expandable metallic stent (Strecker-Stent) for biliary drainage has been attempted in 30 patients. The stent was successfully implanted in 22 patients; in the remaining 8 patients, dilatation of the biliary stricture prior to stent placement was inadequate and delivery of the Strecker-Stent was,...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02734118

    authors: Jaschke W,Klose KJ,Strecker EP

    更新日期:1992-11-01 00:00:00

  • The need for anticoagulation following inferior vena cava filter placement: systematic review.

    abstract:PURPOSE:To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. METHODS:A comprehensive computerized literature search was performed to id...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-007-9244-x

    authors: Ray CE Jr,Prochazka A

    更新日期:2008-03-01 00:00:00

  • Cross-sectional imaging in a case of adventitial cystic disease of the popliteal artery.

    abstract::Adventitial cystic disease of the popliteal artery is an unusual condition of uncertain etiology, in which a mucin-containing cyst forms in the wall of the artery and produces lower extremity claudication, typically in young and middle-aged men. A diagnosis of adventitial cystic disease of the popliteal artery was mad...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900333

    authors: Ricci P,Panzetti C,Mastantuono M,Bassetti E,Iascone C,Ragonesi B,Bernucci P,Gallo P,Rossi P

    更新日期:1999-01-01 00:00:00

  • Histopathological and Bacteriological Analysis of Thrombus Material Extracted During Mechanical Thrombectomy in Acute Stroke Patients.

    abstract:PURPOSE:Management of stroke secondary to septic emboli (SE) remains challenging, due to both the lack of specific recommendations and the gravity of the underlying pathology.The aim of this study is to describe the presence of SE in a series of mechanical thrombectomies (MT), analyzing technical complexity and outcome...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1718-x

    authors: Hernández-Fernández F,Rojas-Bartolomé L,García-García J,Ayo-Martín Ó,Molina-Nuevo JD,Barbella-Aponte RA,Serrano-Heras G,Juliá-Molla E,Pedrosa-Jiménez MJ,Segura T

    更新日期:2017-12-01 00:00:00

  • Diameters of pulmonary veins in normal children--an angiocardiographic study.

    abstract::The diameters of the pulmonary veins at their atrial junction were measured from cineangiocardiographic films in 27 children (mean height 128.5 cm) without heart disease. Right upper pulmonary veins and right lower pulmonary veins were measured in all 27 films. The left upper pulmonary veins could be measured in 23 ch...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02575426

    authors: Robida A

    更新日期:1989-11-01 00:00:00

  • Imaging of the fibrous cap in atherosclerotic carotid plaque.

    abstract::In the last two decades, a substantial number of articles have been published to provide diagnostic solutions for patients with carotid atherosclerotic disease. These articles have resulted in a shift of opinion regarding the identification of stroke risk in patients with carotid atherosclerotic disease. In the recent...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-010-9828-8

    authors: Saba L,Potters F,van der Lugt A,Mallarini G

    更新日期:2010-08-01 00:00:00

  • Impact and Effectiveness of Dual Aspiration Technique in Stent-Assisted Mechanical Thrombectomy: Recent Improvements in Acute Stroke Management.

    abstract:BACKGROUND AND PURPOSE:To evaluate feasibility and impact of dual aspiration technique (DAT) within stent-assisted mechanical thrombectomy on procedural parameters and clinical outcome. MATERIALS AND METHODS:Within 16 months, 76 consecutive patients (mean age 70.7 year; range 33-89) underwent stent-assisted mechanical...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1404-4

    authors: Hopf-Jensen S,Preiß M,Marques L,Lehrke S,Schattschneider J,Stolze H,Müller-Hülsbeck S

    更新日期:2016-11-01 00:00:00

  • Percutaneous Antegrade Varicocele Embolization Via the Testicular Vein in a Patient with Recurrent Varicocele After Surgical Repair.

    abstract::This is a case report of an adolescent male who underwent surgical ligation for a left-sided varicocele that recurred 2 years later. Standard retrograde embolization via the left renal vein was not possible, because there was no connection from the renal vein to the gonadal vein following surgical ligation. The patien...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0978-y

    authors: Guevara CJ,El-Hilal AH,Darcy MD

    更新日期:2015-10-01 00:00:00

  • The use of color-coded duplex scanning in the selection of patients with lower extremity arterial disease for percutaneous transluminal angioplasty: a prospective study.

    abstract:PURPOSE:To exploit the potential benefits of percutaneous transluminal angioplasty (PTA) in patients with short obstructive lesions in the lower extremity, it is preferable to select patients suitable for PTA before proceeding to hospital admission and angiography. The aim of this prospective study was to evaluate the ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02570181

    authors: Elsman BH,Legemate DA,van der Heyden FW,de Vos H,Mali WP,Eikelboom BC

    更新日期:1996-09-01 00:00:00

  • Left femoral vein approach for the percutaneous placement of the Bird's Nest Filter.

    abstract::The Bird's Nest Filter femoral catheter set has proven to be too short in some patients to permit placement in close proximity to the renal veins via the left femoral vein approach. The use of the longer, but otherwise identical Bird's Nest Filter jugular catheter set via the left femoral vein eliminates this problem....

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577893

    authors: Taylor FC,Roehm JO

    更新日期:1991-11-01 00:00:00

  • The road to bioabsorbable stents: reaching clinical reality?

    abstract::This article provides an overview of the evolution of revascularization devices since Grüntzig's initial introduction of balloon angioplasty in 1977. In-stent restenosis (ISR) is the major shortcoming of conventional (permanent-implant) stent therapy; even with the innovation and promising benefits of drug-eluting ste...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-004-0341-9

    authors: Erne P,Schier M,Resink TJ

    更新日期:2006-01-01 00:00:00

  • Time management in acute vertebrobasilar occlusion.

    abstract::Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. E...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-008-9410-9

    authors: Kamper L,Rybacki K,Mansour M,Winkler SB,Kempkes U,Haage P

    更新日期:2009-03-01 00:00:00