Results of a seven-year, single-centre experience of the long-term outcomes of bovine ureter grafts used as novel conduits for haemodialysis fistulas.

Abstract:

PURPOSE:To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. MATERIALS AND METHODS:Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa(®), Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. RESULTS:Mean follow-up time was 97 weeks (range 4-270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. CONCLUSIONS:Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies [1].

authors

Das N,Bratby MJ,Shrivastava V,Cornall AJ,Darby CR,Boardman P,Anthony S,Uberoi R

doi

10.1007/s00270-011-0096-z

subject

Has Abstract

pub_date

2011-10-01 00:00:00

pages

958-63

issue

5

eissn

0174-1551

issn

1432-086X

journal_volume

34

pub_type

杂志文章
  • Instrumentation for magnetic resonance angiography.

    abstract::Magnetic resonance angiography (MRA) places high demands on instrumentation capabilities. Magnetic gradient strength capabilities, main magnetic field strength and homogeneity, and eddy current compensation all play a role in determining the quality of the flow studies. In addition, radiofrequency coil design and use ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02733895

    authors: Saloner D,Anderson CM

    更新日期:1992-01-01 00:00:00

  • Ultrasound-monitored laser angioplasty: preliminary clinical results.

    abstract::A novel coaxial catheter system for ultrasound (US)-guided, pulsed laser angioplasty was tested clinically in 4 patients with stenoses of the femoral and external iliac artery. The mean lesion length was 1.3 +/- 0.4 cm. The 9F multifiber laser catheter incorporated a 4.8F commercial intravascular US catheter and can b...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02602985

    authors: Duda SH,Huppert PE,Kreis A,Karsch KR,Claussen CD

    更新日期:1993-03-01 00:00:00

  • A system for computer-assisted design of stent-grafts for aortic aneurysms using 3-D morphological models.

    abstract::A three-dimensional model was constructed from helical CT images for abdominal aortic aneurysm (AAA) and thoracic aortic aneurysm (TAA). A stent-graft was designed and positioned endoluminally on the computer. One hundred and nine stent-grafts for 101 patients were designed by this method and deployed well in all pati...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-001-0383-8

    authors: Imai Y,Urayama S,Uyama C,Inoue K,Ueno K,Kuribayashi S,Takamiya M,Hamada S,Hirane Y

    更新日期:2001-07-01 00:00:00

  • A Technical Report on the Performance of a New Large Bore Cerebral Aspiration Catheter, the First Results.

    abstract:AIMS AND BACKGROUND:We describe the initial results of the Syphontrack Super Distal Access (SDA) catheter (InNeuroco Inc., Sunrise, Fl, USA) used for endovascular treatment of patients with acute ischemic stroke of the anterior circulation. METHODS:A retrospective review of prospectively collected data from June 2017 ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02280-z

    authors: Benali F,Goldhoorn RB,Wagemans BAJM,van der Leij C,Brans RJB,de Boer SW,de Haan MW,van Zwam WH

    更新日期:2019-12-01 00:00:00

  • Stereotactic radiofrequency ablation (SRFA) of liver lesions: technique effectiveness, safety, and interoperator performance.

    abstract:PURPOSE:To evaluate technique effectiveness, safety, and interoperator performance of stereotactic radiofrequency ablation (SRFA) of liver lesions. METHODS:Retrospective review including 90 consecutive patients from January 2008 to January 2010 with 106 computed tomography-guided SRFA sessions using both single and mu...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0200-4

    authors: Widmann G,Schullian P,Haidu M,Bale R

    更新日期:2012-06-01 00:00:00

  • MDCT anatomic assessment of right inferior phrenic artery origin related to potential supply to hepatocellular carcinoma and its embolization.

    abstract:PURPOSE:To prospectively assess the anatomic variation of the right inferior phrenic artery (RIPA) origin with multidetector computed tomography (MDCT) scans in relation to the technical and angiographic findings during transcatheter arterial embolization of hepatocellular carcinoma (HCC). METHODS:Two hundred patients...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9236-x

    authors: Basile A,Tsetis D,Montineri A,Puleo S,Massa Saluzzo C,Runza G,Coppolino F,Ettorre GC,Patti MT

    更新日期:2008-03-01 00:00:00

  • Broken esophageal stent successfully treated by interventional radiology technique.

    abstract::Esophageal stent fractures occur quite rarely. A 61-year-old male patient was previously treated for rupture of benign stenosis, occurring after dilatation, by implanting an esophageal stent. However, a year after implantation, the patient suffered from dysphagia caused by the broken esophageal stent. He was treated w...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9648-x

    authors: Zelenák K,Mistuna D,Lúcan J,Polácek H

    更新日期:2010-06-01 00:00:00

  • A migrated aortic stent graft causing erosive spondylopathy.

    abstract::We report about a patient presenting with back pain 4 months after an uneventful endovascular implantation of an aortic stent graft. Computed tomography scan revealed a migration of the stent with consecutive endoleakage, kink formation, and movement of the stent toward the spine, which caused destruction of the aorti...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0695-y

    authors: Gestrich C,Probst C,Wilhelm K,Schiller W

    更新日期:2013-12-01 00:00:00

  • Aneurysm of an anomalous systemic artery supplying the normal basal segments of the left lower lobe: endovascular treatment with the Amplatzer Vascular Plug II and coils.

    abstract::An anomalous systemic artery originating from the descending thoracic aorta supplying the normal basal segments of the lower lobe of the left lung without sequestration is a rare congenital anomaly. The published surgical treatments include lobectomy, segmentectomy, anastomosis, and ligation. In addition, endovascular...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9827-9

    authors: Canyigit M,Gumus M,Kilic E,Erol B,Cetin H,Hasanoglu HC,Arslan H

    更新日期:2011-02-01 00:00:00

  • Pulmonary arterial stent implantation in an adult with Williams syndrome.

    abstract::We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent implantation. Short-t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9009-6

    authors: Reesink HJ,Henneman OD,van Delden OM,Biervliet JD,Kloek JJ,Reekers JA,Bresser P

    更新日期:2007-07-01 00:00:00

  • Emergency endovascular treatment of abdominal aortic aneurysms: feasibility and results.

    abstract:PURPOSE:To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). METHODS:During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0080-6

    authors: Laganà D,Carrafiello G,Mangini M,Fontana F,Caronno R,Castelli P,Cuffari S,Fugazzola C

    更新日期:2006-03-01 00:00:00

  • Transcatheter closure of bilateral multiple huge pulmonary arteriovenous malformations with homemade double-umbrella occluders.

    abstract::A 28-year-old man underwent successful transcatheter occlusion of three huge pulmonary arteriovenous malformations (PAVMs) using homemade double-umbrella occluders and stainless steel coils. Thoracic CT with three-dimensional reconstruction and pulmonary angiography were used for treatment planning and follow-up. The ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9242-z

    authors: Zhong H,Xu K,Shao H

    更新日期:2008-07-01 00:00:00

  • Japanese Patients Treated in the IMPERIAL Randomized Trial Comparing Eluvia and Zilver PTX Stents.

    abstract:PURPOSE:The purpose of the study is to report 12-month efficacy and safety results from the subgroup of Japanese patients in the prospective IMPERIAL 2:1 randomized controlled trial (RCT). METHODS:The global IMPERIAL RCT was designed to compare performance of the Eluvia Drug-Eluting Vascular Stent System (Boston Scien...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00270-019-02355-x

    authors: Soga Y,Fujihara M,Iida O,Kawasaki D,Hirano K,Yokoi H,Miyamoto A,Kichikawa K,Nakamura M,Ohki T,Diaz-Cartelle J,Gray WA,Müller-Hülsbeck S

    更新日期:2020-02-01 00:00:00

  • Pulmonary artery aneurysm presenting as a peripheral coin lesion--the danger of needle biopsy.

    abstract::A peripheral pulmonary artery aneurysm appeared as a solitary, smooth and discrete coin lesion in the lung. The aneurysm was surgically resected. Various etiologies possibly responsible for this entity are discussed. The complications of transthoracic needle aspiration biopsy are reviewed, with emphasis on the hazards...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02625112

    authors: Eisenberg D,Gordon RL,Weineman EE,Romanoff H

    更新日期:1984-01-01 00:00:00

  • Gallbladder varices: a potential collateral pathway in portal hypertension and portal vein occlusion.

    abstract::Varices of the gallbladder were demonstrated angiographically in four patients. One patient who had had a mesocaval shunt developed gallbladder varices as a result of hepatoportal shunting. Three patients had gallbladder varices owing to collateral circulation from portal vein occlusion. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02553144

    authors: Charnsangavej C,Thornhill B,Chuang VP,Bernstein RG

    更新日期:1984-01-01 00:00:00

  • Whole-body magnetic resonance angiography with additional steady-state acquisition of the infragenicular arteries in patients with peripheral arterial disease.

    abstract::The purpose of this investigation was to determine if addition of infragenicular steady-state (SS) magnetic resonance angiography (MRA) to first-pass imaging improves diagnostic performance compared with first-pass imaging alone in patients with peripheral arterial disease (PAD) undergoing whole-body (WB) MRA. Twenty ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9759-4

    authors: Nielsen YW,Eiberg JP,Løgager VB,Just S,Schroeder TV,Thomsen HS

    更新日期:2010-06-01 00:00:00

  • Palliation of esophageal cancer with a double-layered covered nitinol stent: long-term outcomes and predictors of stent migration and patient survival.

    abstract:PURPOSE:To evaluate the long-term clinical outcomes and the negative predictors after the deployment of double-layered stents in malignant esophageal strictures. METHODS:This is a single-center study of patients who received a double-layered covered stent for the palliation of dysphagia due to malignant esophageal str...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0829-2

    authors: Mezes P,Krokidis ME,Katsanos K,Spiliopoulos S,Sabharwal T,Adam A

    更新日期:2014-12-01 00:00:00

  • Small cystic insulinoma: value of arterial stimulation venous sampling.

    abstract::Cystic insulinomas are rare, with only three cases having been reported in the literature. It is not difficult to determine the site of such neoplasms, as cystic insulinomas are usually 4-10 cm in diameter. We report a patient with a histologically confirmed cystic insulinoma. This case is unique because of the small ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02743540

    authors: Baba Y,Miyazono N,Nakajo M,Inoue H,Nishida H,Ueno K,Sagara K,Yasuda H,Hagiwara Y,Kijima F,Imamura H,Aikou T

    更新日期:1997-07-01 00:00:00

  • CT-guided irreversible electroporation in an acute porcine liver model: effect of previous transarterial iodized oil tissue marking on technical parameters, 3D computed tomographic rendering of the electroporation zone, and histopathology.

    abstract:PURPOSE:To evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0910-5

    authors: Sommer CM,Fritz S,Vollherbst D,Zelzer S,Wachter MF,Bellemann N,Gockner T,Mokry T,Schmitz A,Aulmann S,Stampfl U,Pereira P,Kauczor HU,Werner J,Radeleff BA

    更新日期:2015-02-01 00:00:00

  • Tolerance of normal aorta to oversized dual balloon valvuloplasty. Observations in a swine model: technical note.

    abstract::The damage threshold during aortic valvuloplasty was determined in 12 normal swine subjected to inflation of oversized dual balloons. Catheters with combined balloon diameters of 1.2-2.0 times the aortic annulus were selected. Following completion of the procedure, the animals were sacrificed and examined for patholog...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577363

    authors: Moore JW,Laird JR,White CJ,Kirby WC,Ramee SR,Banks AK,Ross TC,Graeber GM,Wahl RC

    更新日期:1990-04-01 00:00:00

  • Usefulness of Amplatzer Vascular Plug for Preoperative Embolization Before Distal Pancreatectomy with En Bloc Celiac Axis Resection.

    abstract:PURPOSE:We evaluated the usefulness of the Amplatzer vascular plug (AVP) for preoperative embolization before distal pancreatectomy with en bloc celiac axis resection (DP-CAR). MATERIALS AND METHODS:Between April 2010 and September 2017, 19 patients with locally advanced pancreatic body cancer underwent preoperative e...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02233-6

    authors: Fuji T,Yamagami T,Fukumoto W,Baba Y,Chosa K,Ishikawa M,Iida M,Naito A,Murakami Y,Uemura K,Kondo N,Awai K

    更新日期:2019-09-01 00:00:00

  • Present status of axially angled angiocardiography.

    abstract::Axial angiography visualizes anatomical details of normal and pathological hearts not previously demonstrated by conventional angiography. Progress in the diagnosis of congenital heart malformations using axial projection technique has been reconsidered, emphasizing that the anatomical details of each congenital heart...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552817

    authors: Soto B,Coghlan CH,Bargeron LM

    更新日期:1984-01-01 00:00:00

  • Evaluation of magnetic resonance imaging-compatible needles and interactive sequences for musculoskeletal interventions using an open high-field magnetic resonance imaging scanner.

    abstract::In this article, we study in vitro evaluation of needle artefacts and image quality for musculoskeletal laser-interventions in an open high-field magnetic resonance imaging (MRI) scanner at 1.0T with vertical field orientation. Five commercially available MRI-compatible puncture needles were assessed based on artefact...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9676-6

    authors: Wonneberger U,Schnackenburg B,Streitparth F,Walter T,Rump J,Teichgräber UK

    更新日期:2010-04-01 00:00:00

  • A prospective randomized trial comparing the safety and efficacy of three commercially available closure devices (Angioseal, Vasoseal and Duett).

    abstract:PURPOSE:We compared the safety and efficacy of three closure devices (Angioseal, Vasoseal and Duett) used to close arterial puncture sites in patients who underwent coronary percutaneous procedures. METHODS:A prospective randomized, single-center trial was carried out of consecutive patients who underwent coronary ang...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s00270-002-1942-9

    authors: Michalis LK,Rees MR,Patsouras D,Katsouras CS,Goudevenos J,Pappas S,Sourla E,Kolettis T,Sioros L,Zotou P,Gartzou-Matsouka P,Sideris DA

    更新日期:2002-09-01 00:00:00

  • Imaging of the left ventricle in patients with ischemic heart disease: role of the contrast angiogram.

    abstract::The contrast left ventriculogram is the gold standard against which all other cardiac imaging techniques are measured. In the past decade, noninvasive methods such as radionuclide angiography, echocardiography, computed tomography (CT), and digital substraction imaging have become available. This review examines the r...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552300

    authors: Baltaxe HA

    更新日期:1982-01-01 00:00:00

  • Radial artery approach to salvage nonmaturing radiocephalic arteriovenous fistulas.

    abstract:PURPOSE:To evaluate the usefulness of an approach through the radial artery distal to the arteriovenous anastomosis for salvaging nonmaturing radiocephalic arteriovenous fistulas. METHODS:Procedures that fulfilled the following criteria were retrospectively reviewed: (1) autogenous radiocephalic fistulas, (2) fistulas...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0533-7

    authors: Hsieh MY,Lin L,Tsai KC,Wu CC

    更新日期:2013-08-01 00:00:00

  • Pulmonary air embolism: case report.

    abstract::The authors encountered a patient with an indwelling central venous catheter who presented with pulmonary edema after the catheter hub was disconnected. Pulmonary arteriography demonstrated diffuse peripheral vasoconstriction, decreased arterial-to-venous transit time, and arterial occlusions. The former two findings ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02578472

    authors: Karr SB,Schwab FJ,Druy EM

    更新日期:1991-07-01 00:00:00

  • Custom-Made Endograft for Endovascular Repair of Thoraco-Abdominal Aneurysm and Type B Dissection: Single-Centre Experience.

    abstract:AIMS:To report a series of patients treated with the Jotec custom-made endograft for thoraco-abdominal aneurysms and dissections and identify predictive factors for re-intervention. METHODS:We retrospectively analysed 49 patients unsuitable for surgery, treated between 2011 and 2017 (71.3 ± 9.5 years; 15 females). Ind...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-1975-3

    authors: Lucatelli P,Cini M,Benvenuti A,Saba L,Tommasino G,Guaccio G,Munneke G,Neri E,Ricci C

    更新日期:2018-08-01 00:00:00

  • Intracranial Aneurysms Treated by Flow-Diverting Stents: Long-Term Follow-Up with Contrast-Enhanced Magnetic Resonance Angiography.

    abstract:PURPOSE:Long-term data on aneurysm treatment with flow-diverting stents are still sparse, and follow-up protocols differ widely between institutions. We present long-term results, with a focus on the usefulness of contrast-enhanced MR angiography (ceMRA). MATERIALS AND METHODS:Interventions and follow-up imaging of pa...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1732-z

    authors: Patzig M,Forbrig R,Ertl L,Brückmann H,Fesl G

    更新日期:2017-11-01 00:00:00

  • Experimental impeller fragmentation of iliocaval thrombosis under tulip filter protection: preliminary results.

    abstract:PURPOSE:To assess the efficacy of catheter fragmentation of massive caval thrombosis and of filter protection against procedure-related pulmonary embolism. METHODS:In 10 sheep, a self-expanding tulip-shaped filter made from Wallstent mesh (diameter 25 mm) was introduced from the right jugular approach into the proxima...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577646

    authors: Schmitz-Rode T,Vorwerk D,Schürmann K,Günther RW

    更新日期:1996-07-01 00:00:00