CT-guided irreversible electroporation in an acute porcine liver model: effect of previous transarterial iodized oil tissue marking on technical parameters, 3D computed tomographic rendering of the electroporation zone, and histopathology.

Abstract:

PURPOSE:To evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance. METHODS:After Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann-Whitney test. Histopathological differences were assessed. RESULTS:Mean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm(3), and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm(3), and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone. CONCLUSION:There is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver.

authors

Sommer CM,Fritz S,Vollherbst D,Zelzer S,Wachter MF,Bellemann N,Gockner T,Mokry T,Schmitz A,Aulmann S,Stampfl U,Pereira P,Kauczor HU,Werner J,Radeleff BA

doi

10.1007/s00270-014-0910-5

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

191-200

issue

1

eissn

0174-1551

issn

1432-086X

journal_volume

38

pub_type

杂志文章
  • Cutting-balloon angioplasty versus balloon angioplasty as treatment for short atherosclerotic lesions in the superficial femoral artery: randomized controlled trial.

    abstract:PURPOSE:To evaluate the treatments of a short-segment atherosclerotic stenosis in the superficial femoral arteries with the cutting balloon angioplasty (CBA) versus conventional balloon angioplasty [percutaneous transluminal angioplasty (PTA)] in a randomized controlled trial. MATERIAL AND METHODS:The study group comp...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00270-013-0603-5

    authors: Poncyljusz W,Falkowski A,Safranow K,Rać M,Zawierucha D

    更新日期:2013-12-01 00:00:00

  • Percutaneous lymph node biopsy.

    abstract::Advances in imaging modalities for detecting lymphadenopathy, the ease, safety, and accuracy of the tools and techniques, and the addition of refined ancillary studies for cytologic analysis will continue to increase the acceptance and use of percutaneous lymph node biopsy (PLNB) by fine-needle aspiration (FNA), espec...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/BF02635532

    authors: Lawrence DD,Carrasco CH,Fornage B,Sneige N,Wallace S

    更新日期:1991-01-01 00:00:00

  • Persistent sciatic artery: bilateral percutaneous transluminal angioplasty in ischemic disease.

    abstract::Persistent sciatic artery (PSA) is a rare vascular anomaly that results from failure of an embryonal artery to the lower extremities to regress during fetal development. Aneurysm formation, thromboembolism, and arterial occlusions may complicate this abnormality. We report a patient with complete bilateral PSA and int...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02603144

    authors: Mathias KD,Feldmüller M,Haarmann P,Goldbeck F

    更新日期:1993-11-01 00:00:00

  • Present status of axially angled angiocardiography.

    abstract::Axial angiography visualizes anatomical details of normal and pathological hearts not previously demonstrated by conventional angiography. Progress in the diagnosis of congenital heart malformations using axial projection technique has been reconsidered, emphasizing that the anatomical details of each congenital heart...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552817

    authors: Soto B,Coghlan CH,Bargeron LM

    更新日期:1984-01-01 00:00:00

  • Lifesaving embolization of coronary artery perforation.

    abstract::Coronary artery perforation remains one of the most fearsome complications during cardiac catheterization procedures. Although emergent bypass surgery is the preferred treatment for cases with uncontrollable perforation, endovascular vessel sealing and arrest of bleeding with a combination of balloons, covered stents,...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9657-9

    authors: Katsanos K,Patel S,Dourado R,Sabharwal T

    更新日期:2009-09-01 00:00:00

  • Arteriographic study of variant arterial anatomy of the upper extremities.

    abstract::Anatomic variations in the major arteries of the upper extremities have been reported in 11-24.4% of individuals. In a review of 100 upper extremity arteriograms, we found an overall incidence of 9%. High origin of the radial artery from the brachial artery was the most frequently encountered anomaly occurring in 7% o...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577379

    authors: Uglietta JP,Kadir S

    更新日期:1989-05-01 00:00:00

  • Transarterial Bleomycin-Lipiodol Embolization (B/LE) for Symptomatic Giant Hepatic Hemangioma.

    abstract:BACKGROUND:Large hepatic hemangiomas can cause symptoms such as pain and bleeding. No consensus currently exists on the optimal management of large and symptomatic hemangiomas. The purpose of this study was to evaluate the role of transarterial bleomycin-lipiodol embolization (B/LE) in the treatment of symptomatic larg...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-2010-4

    authors: Akhlaghpoor S,Torkian P,Golzarian J

    更新日期:2018-11-01 00:00:00

  • Segment 2/3 Hypertrophy is Greater When Right Portal Vein Embolisation is Extended to Segment 4 in Patients with Colorectal Liver Metastases: A Retrospective Cohort Study.

    abstract:BACKGROUND:In patients with colorectal cancer liver metastases (CRLM), right portal vein embolisation (RPVE) is used to increase the volume of the future remnant liver (FRL) before major hepatic resection. It is not established whether embolisation of segment 4 in addition RPVE (RPVE + 4) induces greater hypertrophy of...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-02159-5

    authors: Hammond CJ,Ali S,Haq H,Luo L,Wyatt JI,Toogood GJ,Lodge JPA,Patel JV

    更新日期:2019-04-01 00:00:00

  • Renal stenting from the radial artery: a novel approach.

    abstract:PURPOSE:To describe the technique and feasibility of renal artery angioplasty and stenting from the radial artery. METHODS:A series of 19 patients were evaluated for transradial renal artery intervention. Procedures were performed using carbon dioxide gas (CO2) as the preferred angiographic contrast agent. Interventio...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-001-0114-7

    authors: Kessel DO,Robertson I,Taylor EJ,Patel JV

    更新日期:2003-03-01 00:00:00

  • CT guided bone biopsy using a battery powered intraosseous device.

    abstract:PURPOSE:To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. METHODS:Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacar...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0617-z

    authors: Schnapauff D,Marnitz T,Freyhardt P,Collettini F,Hartwig K,Jöhrens K,Hamm B,Kroencke T,Gebauer B

    更新日期:2013-10-01 00:00:00

  • A new balloon-expandable tantalum stent (Strecker-Stent) for the biliary system: preliminary experience.

    abstract::Placement of a balloon-expandable metallic stent (Strecker-Stent) for biliary drainage has been attempted in 30 patients. The stent was successfully implanted in 22 patients; in the remaining 8 patients, dilatation of the biliary stricture prior to stent placement was inadequate and delivery of the Strecker-Stent was,...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02734118

    authors: Jaschke W,Klose KJ,Strecker EP

    更新日期:1992-11-01 00:00:00

  • Therapeutic consequences of variation in intraarterial pressure measurements after iliac angioplasty.

    abstract:PURPOSE:To assess the accuracy of intraarterial measurement of transstenotic pressure gradients for the detection of hemodynamically suboptimal iliac angioplasty. METHODS:In 14 patients, referred for diagnostic angiography, mean pressure gradients in the aorta and iliac artery were obtained twice, using a double-senso...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900187

    authors: Tetteroo E,Haaring C,van Engelen AD,van der Graaf Y,Mali WP

    更新日期:1997-11-01 00:00:00

  • Catheter-directed thrombolysis of inferior vena cava thrombosis in a 13-day-old neonate and review of literature.

    abstract::Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) wit...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-007-9229-9

    authors: Khan JU,Takemoto CM,Casella JF,Streiff MB,Nwankwo IJ,Kim HS

    更新日期:2008-07-01 00:00:00

  • A Prospective Clinical Study of a Percutaneous Vascular Access System for Hemodialysis Catheters.

    abstract:INTRODUCTION:Dysfunctional or infected hemodialysis polyester-cuffed catheters often require removal and are dissected out. The DermaPort™, percutaneous vascular access system (PVAS) permanently integrates a titanium mesh with the skin forming a stable, sterile barrier that allows for catheter placement, adjustment, or...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-2031-z

    authors: Rajan DK,Moran B,Lobl TJ,Asch MR,Steele AW,Lok CE

    更新日期:2018-10-01 00:00:00

  • Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm.

    abstract::We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1161-9

    authors: Goltz JP,Loesaus J,Frydrychowicz A,Barkhausen J,Wiedner M

    更新日期:2016-02-01 00:00:00

  • Access to the superficial femoral artery in the presence of a "hostile groin": a prospective study.

    abstract:PURPOSE:Lower limb angioplasty is commonly performed via antegrade common femoral artery (CFA) puncture, followed by selective superficial femoral artery (SFA) catheterization. Arterial access can be complicated by a "hostile groin" (scarring, obesity, or previous failed CFA puncture). We prospectively investigated col...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0347-y

    authors: Marcus AJ,Lotzof K,Howard A

    更新日期:2007-05-01 00:00:00

  • Carotid stenting in a case of combined kinking and stenosis.

    abstract::Endarterectomy is currently the preferred treatment for severe carotid stenosis. The technique of eversion endarterectomy allows correction of severe vessel elongation and kinking. The latter is generally believed to be a relative contraindication for endovascular stent placement. We report successful percutaneous tra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/pl00021043

    authors: Ahmadi RA,Schillinger M,Haumer M,Willfort A,Minar E

    更新日期:2001-05-01 00:00:00

  • Sclerotherapy for simple cysts with use of ethanolamine oleate: preliminary experience.

    abstract::We evaluated the efficacy of ethanolamine oleate (EO) as a sclerosing agent for a symptomatic hepatic or renal cyst. Seven patients with symptomatic hepatic (n = 3) or renal cysts (n = 4) were treated by sclerotherapy with EO. The cyst size in the greater diameter ranged from 6 to 13 cm. The cyst was punctured under u...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00270-004-0277-0

    authors: Yamamoto K,Sakaguchi H,Anai H,Tanaka T,Morimoto K,Kichikawa K,Uchida H

    更新日期:2005-11-01 00:00:00

  • Application of Percutaneous Osteoplasty in Treating Pelvic Bone Metastases: Efficacy and Safety.

    abstract:BACKGROUND:Percutaneous vertebroplasty has been a good option to treat vertebral metastases. The pelvic bone is a common site of spread for many cancers. Using follow-up data for 126 patients, we evaluated the safety and efficacy of percutaneous osteoplasty (POP) to treat pelvic bone metastases. MATERIALS AND METHODS:...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02320-8

    authors: Liu HF,Wu CG,Tian QH,Wang T,Yi F

    更新日期:2019-12-01 00:00:00

  • Magnetic resonance-guided focused ultrasound ablation in abdominal moving organs: a feasibility study in selected cases of pancreatic and liver cancer.

    abstract:PURPOSE:This study was designed to evaluate preliminarily the feasibility and safety of magnetic resonance-guided focused ultrasound (MRgFUS) for treatment of solid tumors in the upper abdomen. METHODS:We enrolled one patient with hepatocellular carcinoma and two patients with pancreatic adenocarcinoma for MRgFUS abla...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0861-x

    authors: Anzidei M,Napoli A,Sandolo F,Marincola BC,Di Martino M,Berloco P,Bosco S,Bezzi M,Catalano C

    更新日期:2014-12-01 00:00:00

  • Review of the ability of optical coherence tomography to characterize plaque, including a comparison with intravascular ultrasound.

    abstract::Over the last 50 years the introduction of several imaging technologies have been pivotal in reducing mortality associated with coronary artery disease. However coronary disease continues to be the leading cause of mortality in the industrialized world. Optical coherence tomography (OCT) has recently been introduced f...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-003-0021-1

    authors: Patel NA,Stamper DL,Brezinski ME

    更新日期:2005-01-01 00:00:00

  • General theory of predictive dosimetry for yttrium-90 radioembolization to sites other than the liver.

    abstract::Modern advances in interventional radiology and nuclear medicine may now allow for safe and effective 90Y radioembolization to sites other than the liver. A general theory of predictive dosimetry based on the MIRD schema is proposed, adapted from the original partition model for liver 90Y radioembolization. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 评论,信件

    doi:10.1007/s00270-013-0783-z

    authors: Kao YH

    更新日期:2014-08-01 00:00:00

  • Saline as the sole contrast agent for successful MRI-guided epidural injections.

    abstract:PURPOSE:To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. METHODS:A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced sal...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0489-7

    authors: Deli M,Fritz J,Mateiescu S,Busch M,Carrino JA,Becker J,Garmer M,Grönemeyer D

    更新日期:2013-06-01 00:00:00

  • Thoracic Duct Embolization in Post-neck Dissection Chylous Leakage: A Case Series of Six Patients and Review of the Literature.

    abstract::Chylous leak is a serious complication of neck dissection. Patients are often managed conservatively, and failure of conservative management necessitates surgical management, which adds to their morbidity. We present a case series demonstrating the value of thoracic duct embolization (TDE) in management of patients wi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-020-02475-9

    authors: Moussa AM,Maybody M,Gonzalez-Aguirre AJ,Buicko JL,Shaha AR,Santos E

    更新日期:2020-06-01 00:00:00

  • Oscillating probe aspiration thrombectomy: comparative in vitro evaluation of two concepts.

    abstract::Aspiration thrombectomy supported by an oscillating metal probe within the catheter allows continuous aspiration of large thrombi without catheter obstruction. Thrombus aspiration assisted by an ultrasound-driven probe (frequency 26 kHz) and by an electric motor-driven probe (frequency 40 Hz) was compared in two diffe...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02735577

    authors: Schmitz-Rode T,Günther RW

    更新日期:1992-05-01 00:00:00

  • The Randomized Freeway Stent Study: Drug-Eluting Balloons Outperform Standard Balloon Angioplasty for Postdilatation of Nitinol Stents in the SFA and PI Segment.

    abstract:PURPOSE:The prospective randomized multicenter Freeway study evaluated the possible hemodynamic and clinical benefits of primary stent insertion followed by percutaneous transluminal angioplasty (PTA) with drug-eluting balloons (DEB) over post-stent insertion PTA with standard balloons in the treatment of symptomatic f...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00270-019-02309-3

    authors: Tacke J,Müller-Hülsbeck S,Schröder H,Lammer J,Schürmann K,Gross-Fengels W,Fischbach R,Textor J,Boguth L,Loewe C,Häuser H,Gschwendtner M,Tepe G,von Strandmann RP,Stahnke S,Dambach J,Hausegger K

    更新日期:2019-11-01 00:00:00

  • Prophylactic Temporary Occlusion of the Cystic Artery Using a Fibered Detachable Coil During 90Y Radioembolization.

    abstract:PURPOSE:To address the feasibility of prophylactic temporary occlusion of the cystic artery using a detachable coil during 90Y radioembolization. MATERIALS AND METHODS:From January 2012 to October 2016, nine patients underwent temporary occlusion of the cystic artery during 90Y radioembolization. Based on the planning...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1688-z

    authors: Choi JW,Yoo MY,Kim HC,Paeng JC,Kim YJ,Chung JW

    更新日期:2017-10-01 00:00:00

  • Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    abstract:PURPOSE:The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. MATERIALS AND METHODS:Three human cadavers embalmed ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1643-z

    authors: McLeod H,Cox BF,Robertson J,Duncan R,Matthew S,Bhat R,Barclay A,Anwar J,Wilkinson T,Melzer A,Houston JG

    更新日期:2017-09-01 00:00:00

  • Does Technical Success of Angioplasty in Dysfunctional Hemodialysis Accesses Correlate with Access Patency?

    abstract:PURPOSE:To study if <30 % residual stenosis post angioplasty (PTA) correlates with primary access circuit patency, and if any variables predict technical success. MATERIALS AND METHODS:A prospective observational study was performed between January 2009 and December 2012, wherein 76 patients underwent 154 PTA events i...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1401-7

    authors: Sidhu A,Tan KT,Noel-Lamy M,Simons ME,Rajan DK

    更新日期:2016-10-01 00:00:00

  • Tolerance of normal aorta to oversized dual balloon valvuloplasty. Observations in a swine model: technical note.

    abstract::The damage threshold during aortic valvuloplasty was determined in 12 normal swine subjected to inflation of oversized dual balloons. Catheters with combined balloon diameters of 1.2-2.0 times the aortic annulus were selected. Following completion of the procedure, the animals were sacrificed and examined for patholog...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577363

    authors: Moore JW,Laird JR,White CJ,Kirby WC,Ramee SR,Banks AK,Ross TC,Graeber GM,Wahl RC

    更新日期:1990-04-01 00:00:00