Femtosecond laser in situ keratomileusis after radial keratotomy.

Abstract:

PURPOSE:To assess the safety, efficacy, and predictability of femtosecond laser in situ keratomileusis (LASIK) in eyes with previous radial keratotomy (RK). SETTING:Hospital Virgen del Consuelo de Valencia, Valencia, and Vissum Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS:This prospective study comprised 11 eyes of 7 patients with residual low myopia after previous RK who had surgery with the IntraLase femtosecond laser (IntraLase Corp.) and the Star 2 excimer laser (Visx, Inc.). Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), defocus equivalent, refraction, flap thickness, flap diameter, and intraoperative complications were evaluated over a minimum 6-month follow-up. RESULTS:Although the RK incisions opened in all eyes when the flap was lifted, LASIK was successfully completed in all cases. Mean flap thickness was 119 microm +/- 13 (SD). There were no cases of slipped flaps, microstriae, or epithelial ingrowth. Defocus equivalent was reduced from a mean of 2.51 +/- 0.62 diopters (D) to 0.52 +/- 0.28 D; 7 eyes (63.6%) were within +/-0.50 D, and 11 eyes (100%) were within +/-1.00 D. All eyes had 20/40 or better UCVA, although 2 eyes (18.1%) lost 1 line of BSCVA. CONCLUSIONS:The femtosecond laser was safely used to create thin LASIK flaps in eyes with previous RK. An increased postoperative inflammatory response may explain the loss of BSCVA in some cases. Efficacy and predictability of the procedure were comparable to those of LASIK after RK with mechanical microkeratomes.

authors

Muñoz G,Albarrán-Diego C,Sakla HF,Pérez-Santonja JJ,Alió JL

doi

10.1016/j.jcrs.2006.02.061

subject

Has Abstract

pub_date

2006-08-01 00:00:00

pages

1270-5

issue

8

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(06)00554-2

journal_volume

32

pub_type

杂志文章
  • Intraocular lens prediction accuracy after corneal refractive surgery using K values from 3 devices.

    abstract:PURPOSE:To compare results of intraocular lens (IOL) power calculation methods using different keratometry (K) values after myopic refractive surgery. SETTING:Seoul St. Mary's Hospital, Seoul, South Korea. DESIGN:Evaluation of diagnostic test or technology. METHODS:The IOL power of patients who had cataract surgery ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.04.045

    authors: Kim EC,Cho K,Hwang HS,Hwang KY,Kim MS

    更新日期:2013-11-01 00:00:00

  • Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.

    abstract:PURPOSE:To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry. SETTING:Clinica Centrofama, Cartagena, Murcia, Spain. METHODS:Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACM...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.10.038

    authors: Lara F,Fernández-Sánchez V,López-Gil N,Cerviño A,Montés-Micó R

    更新日期:2009-02-01 00:00:00

  • Four-point fixation of posterior chamber intraocular lenses in children with unilateral aphakia.

    abstract:PURPOSE:To evaluate the results of 4-point scleral fixation of posterior chamber intraocular lenses (PC IOLs) in children. SETTING:Mansoura Ophthalmic Center, Mansoura University, Mansoura, Egypt. METHODS:This retrospective study comprised 20 aphakic eyes of 20 children. Preoperative investigations proved the absence...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01531-6

    authors: Sewelam A

    更新日期:2003-02-01 00:00:00

  • Long-term results of myopic epikeratoplasty.

    abstract::Twenty-three eyes of 20 patients who had had myopic epikeratoplasty were evaluated and the mean 21-month postoperative results (range: 12 to 47 months) tabulated. Average preoperative myopia was -16.7 diopters (D) spherical equivalent (range: -10 to -33 D), and average postoperative refractive correction was 13 D. Of ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80305-7

    authors: Kim WJ,Lee JH

    更新日期:1993-05-01 00:00:00

  • A new technique of congenital cataract surgery with primary posterior chamber intraocular lens implantation.

    abstract::We present a series of nine cases involving primary intraocular lens implantation in congenital cataracts. Because of the problems encountered with the technique used in the earlier cases, we developed a new surgical technique that may be described as primary epilenticular posterior chamber lens implantation followed ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(88)80088-9

    authors: Tablante RT,Lapus JV,Cruz ED,Santos AM

    更新日期:1988-03-01 00:00:00

  • Imaging corneal crosslinking by autofluorescence 2-photon microscopy, second harmonic generation, and fluorescence lifetime measurements.

    abstract:PURPOSE:To evaluate the use of 2-photon microscopy (TPM), which excites tissue autofluorescence, in detecting and calculating the grade of collagen corneal crosslinks, which are not visible through the slitlamp and in vivo confocal microscopy. SETTING:Departments of Ophthalmology, University of Lübeck, Lübeck, and Uni...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.06.068

    authors: Steven P,Hovakimyan M,Guthoff RF,Hüttmann G,Stachs O

    更新日期:2010-12-01 00:00:00

  • Near-point string: Simple method to demonstrate anticipated near point for multifocal and accommodating intraocular lenses.

    abstract:UNLABELLED:We present a technique that uses a near-point string to demonstrate the anticipated near point of multifocal and accommodating intraocular lenses (IOLs). Beads are placed on the string at distances corresponding to the near points for diffractive and accommodating IOLs. The string is held up to the patient's...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.04.003

    authors: George MC,Lazer ZP,George DS

    更新日期:2016-05-01 00:00:00

  • Using artificial intelligence to predict the risk for posterior capsule opacification after phacoemulsification.

    abstract:PURPOSE:To apply artificial intelligence models to predict the occurrence of posterior capsule opacification (PCO) after phacoemulsification. SETTING:Farabi Eye Hospital, Tehran, Iran. DESIGN:Clinical-based cross-sectional study. METHODS:The posterior capsule status of eyes operated on for age-related cataract and t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.09.036

    authors: Mohammadi SF,Sabbaghi M,Z-Mehrjardi H,Hashemi H,Alizadeh S,Majdi M,Taee F

    更新日期:2012-03-01 00:00:00

  • Rheological behavior of commercial artificial tear solutions.

    abstract:PURPOSE:To measure the rheological behaviour of artificial tears to gain insight into the potential role of rheology in predicting the efficacy of artificial tear solutions for the treatment of dry eye disease (DED). SETTING:Research laboratories of I-MED Pharma, Canada, Rohn and Associates, Inc., New Jersey, and Hyda...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000507

    authors: Arshinoff S,Hofmann I,Nae H

    更新日期:2020-11-30 00:00:00

  • Cytokeratin in lens epithelial cells and its effect on anterior lens capsule opacification.

    abstract::Postoperative lens capsule opacification is a complication of extracapsular cataract extraction. To avoid this problem, we aspirated the epithelial cells lining the internal surface of the capsular bag. Anterior capsule specimens collected three and six years after the first surgical intervention (extracapsular catara...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80302-1

    authors: Budo C,Montanus F,Goffinet G,Goossens G,Gaill F

    更新日期:1993-05-01 00:00:00

  • Functional vision with cataracts of different morphologies: comparative study.

    abstract:PURPOSE:To evaluate the influence of cataract morphology on the functional vision of patients with age-related cataract and normal macular function and compare subjectively perceived functional impairments to distance visual acuity, reading acuity, and maximum reading speed between cataract types. SETTING:Department o...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.01.038

    authors: Stifter E,Sacu S,Weghaupt H

    更新日期:2004-09-01 00:00:00

  • Noncorneal astigmatism related to poly(methyl methacrylate) and plate-haptic silicone intraocular lenses.

    abstract:PURPOSE:To evaluate noncorneal astigmatism after implantation of a one-piece, plate-haptic silicone or one-piece poly(methyl methacrylate) PMMA intraocular lens (IOL). SETTING:Klinik und Poliklinik für Augenheilkunde der Universität Regensburg, Germany. METHODS:After a follow-up of at least 3 months, the degree of po...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(97)80117-4

    authors: Spiegel D,Widmann A,Köll R

    更新日期:1997-11-01 00:00:00

  • Complete capsular bag distension syndrome.

    abstract::After conventional extracapsular cataract extraction and in-the-bag intr aocular lens (IOL) implantation 3 years previously, the partially cut su perior one-third of the anterior capsulotomy flap resealed in the eye of a 55-year-old woman. With the integrity of the capsular bag restored, it distended fully; the IOL wa...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00403-x

    authors: Agrawal S,Agrawal J,Agrawal TP

    更新日期:2000-09-01 00:00:00

  • Laser in situ keratomileusis for -6.00 to -18.00 diopters of myopia and up to -5.00 diopters of astigmatism: 15-year follow-up.

    abstract:PURPOSE:To evaluate the long-term outcomes of laser in situ keratomileusis (LASIK) for high myopia with or without astigmatism. SETTING:Vissum Instituto Oftalmologico de Alicante and Miguel Hernandez University, Alicante, Spain. DESIGN:Retrospective-prospective case series. METHODS:Laser in situ keratomileusis was p...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.08.029

    authors: Alió JL,Soria F,Abbouda A,Peña-García P

    更新日期:2015-01-01 00:00:00

  • Implantation of an Artisan iris-fixated phakic intraocular lens for the correction of hyperopia, a 15 year follow-up.

    abstract:PURPOSE:To assess the predictability, efficacy, stability and safety of implantation of an Artisan (Ophtec BV, the Netherlands) iris-fixated phakic intraocular lens (IF-pIOL) for the correction of hyperopia with a follow-up of up to 15 years. SETTING:Leiden University Medical Center, The Netherlands METHODS:: Patients...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000532

    authors: van Rijn GA,Gaurisankar ZS,Saxena R,Gibbes D,Jongman HP,Haasnoot GW,Cheng YYY,Beenakker JM,Luyten GPM

    更新日期:2020-11-27 00:00:00

  • Transzonular capsulo-hyaloidal hydroseparation with optional triamcinolone enhancement: A technique to detect or induce anterior hyaloid membrane detachment for primary posterior laser capsulotomy.

    abstract::Primary posterior laser capsulotomy (PPLC) requires adequate visualization and spacing of the posterior lens capsule (PLC) and anterior hyaloid membrane (AHM). After intraocular lens implantation and watertight incision hydration, the laser is redocked for optical coherence tomography reimaging. If the PLC and AHM are...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2019.03.008

    authors: Menapace R

    更新日期:2019-07-01 00:00:00

  • Trocar anterior chamber maintainer: Improvised infusion technique.

    abstract:UNLABELLED:We present an improvised technique of infusion that uses a trocar cannula as an anterior chamber maintainer (ACM). Although routinely used in posterior segment surgery, the trocar cannula has been infrequently used in complex anterior segment procedures. The trocar ACM creates a transconjunctival biplanar wo...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.01.015

    authors: Agarwal A,Narang P,Kumar DA,Agarwal A

    更新日期:2016-02-01 00:00:00

  • Use of bipolar diathermy to prevent posterior capsule opacification(1).

    abstract:PURPOSE:To determine the feasibility of using directed bipolar diathermy to eliminate or reduce the formation of new cortical lens material following phacoemulsification in a rabbit model. SETTING:Department of Research & Development, Bausch & Lomb Surgical, and Department of Ophthalmology, St. Louis University, St. L...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)01256-1

    authors: Bretton RH,Kash RL,Schanzlin DJ

    更新日期:2002-05-01 00:00:00

  • Retinal detachment following intracapsular and extracapsular cataract extraction.

    abstract::In 1984, our ophthalmology department switched from intracapsular cataract extraction (ICCE) to extracapsular cataract extraction (ECCE). We reviewed the postoperative incidence of retinal detachment (RD) in two consecutive series: (1) 604 eyes operated on by ICCE from 1982 to 1983 and (2) 1726 eyes operated on by ECC...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80498-1

    authors: Naeser K,Nielsen NE

    更新日期:1995-03-01 00:00:00

  • Aqueous flare intensity after phacoemulsification in patients with diabetes mellitus.

    abstract:PURPOSE:To prospectively compare the postoperative blood-aqueous barrier breakdown induced by phacoemulsification and implantation of a heparin-surface-modified poly(methyl methacrylate) intraocular lens in the capsular bag in eyes with different stages of diabetic retinopathy (DR) and a control group. SETTING:St. Eri...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80104-1

    authors: Zaczek A,Zetterström C

    更新日期:1998-08-01 00:00:00

  • Aspergillus fumigatus keratitis following laser in situ keratomileusis.

    abstract::A 31-year-old woman developed pain, decreased vision, and a corneal flap infiltrate 4 days following laser in situ keratomileusis (LASIK). Treatment with topical antibiotic agents did not improve the symptoms. Approximately 2 weeks after surgery, the patient was referred to Stanford University, with 20/400 visual acui...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.05.051

    authors: Sun Y,Jain A,Ta CN

    更新日期:2007-10-01 00:00:00

  • Prophylactic intracameral cefuroxime. Evaluation of safety and kinetics in cataract surgery.

    abstract:PURPOSE:To evaluate the safety and kinetics of prophylactic intracameral cefuroxime in cataract surgery. SETTING:Department of Ophthalmology, St. Eriks Hospital, Stockholm, Sweden. METHODS:In a nonrandomized observer-masked best-case trial, the visual rehabilitation and the evolution of laser flare intensity and corn...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0886-3350(01)01270-6

    authors: Montan PG,Wejde G,Setterquist H,Rylander M,Zetterström C

    更新日期:2002-06-01 00:00:00

  • Outcomes of cataract surgery and intraocular lens implantation with and without intracameral triamcinolone in pediatric eyes.

    abstract:PURPOSE:To evaluate whether intracameral triamcinolone has an effect on anterior segment inflammation and visual axis obscuration after pediatric cataract surgery with intraocular (IOL) implantation. SETTING:Iladevi Cataract and IOL Research Institute, Ahmedabad, India. METHODS:This retrospective age-matched case-con...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.03.040

    authors: Dixit NV,Shah SK,Vasavada V,Vasavada VA,Praveen MR,Vasavada AR,Trivedi RH

    更新日期:2010-09-01 00:00:00

  • Pathology of 157 human cadaver eyes with round-edged or modern square-edged silicone intraocular lenses: analyses of capsule bag opacification.

    abstract:PURPOSE:To assess the degree of capsular bag opacification in human cadaver eyes with silicone intraocular lenses (IOLs), specifically comparing the differences between round-edged IOLs and modern square-edged IOLs. SETTING:John A. Moran Eye Center, University of Utah, USA. DESIGN:Experimental study. METHODS:The eye...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.10.058

    authors: Maddula S,Werner L,Ness PJ,Davis D,Zaugg B,Stringham J,Burrow M,Yeh O

    更新日期:2011-04-01 00:00:00

  • Laser in situ keratomileusis assisted by corneal topography.

    abstract:PURPOSE:To assess whether laser in situ keratomileusis (LASIK) assisted by corneal topography can successfully treat corneal irregularities or irregular astigmatism in patients with previous ocular surgery or ocular trauma. SETTING:University Eye Hospital, Klinikum Mannheim, Mannheim, Germany. METHODS:In a prospectiv...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80196-x

    authors: Wiesinger-Jendritza B,Knorz MC,Hugger P,Liermann A

    更新日期:1998-02-01 00:00:00

  • Correcting postoperative astigmatism using curved lamellating keratotomy.

    abstract:PURPOSE:To ascertain whether the change in refraction caused by paired lamellating corneal incisions in cadaver eyes could be achieved in living eyes and whether wound healing influences this effect. SETTING:Virchow Hospital Eye Clinic, Humboldt University, Berlin, Germany. METHODS:This prospective study included 45 ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(97)80342-2

    authors: Anders N,Pham DT,Huebscher HJ,Linke C,Wollensak J

    更新日期:1997-03-01 00:00:00

  • Five-year results of deep sclerectomy with collagen implant.

    abstract:PURPOSE:To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI), a nonpenetrating filtration procedure. SETTING:Glaucoma Unit, Department of Ophthalmology, Hôpital Ophtalmique Jules Gonin, University of Lausanne, Lausanne, Switzerland. METHODS:This nonrandomized pros...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0886-3350(01)01032-x

    authors: Shaarawy T,Karlen M,Schnyder C,Achache F,Sanchez E,Mermoud A

    更新日期:2001-11-01 00:00:00

  • Bilateral Candida parapsilosis interface keratitis after laser in situ keratomileusis.

    abstract::We report a case of Candida infection after laser in situ keratomileusis (LASIK) and review the literature for reports of post-LASIK fungal infections. Risk factors may include postoperative surgical intervention and extended use of topical steroids. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00217-7

    authors: Muallem MS,Alfonso EC,Romano AC,Miller D,Kurstin J,Marangon FB,Culbertson WW,Yoo SH

    更新日期:2003-10-01 00:00:00

  • Step-down technique.

    abstract::From the beginning of nuclear fragment removal to the end, we progressively reduce all the parameters, ie, energy, vacuum, and aspiration flow rate, in a step-by-step manner proportionate to the posterior capsule exposure. This promotes adaptation of various parameters to the appropriate stages of surgery and allows t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00121-4

    authors: Vasavada AR,Raj S

    更新日期:2003-06-01 00:00:00

  • C constant: new concept for ray tracing-assisted intraocular lens power calculation.

    abstract:PURPOSE:To evaluate the accuracy of the C constant for ray tracing-assisted intraocular lens (IOL) power calculation. DESIGN:Case series. SETTING:Public university hospital and private clinic. METHODS:Preoperatively, all intraocular distances were measured using laser biometry. Various IOL designs were studied; powe...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1016/j.jcrs.2013.10.037

    authors: Olsen T,Hoffmann P

    更新日期:2014-05-01 00:00:00