Abstract:
PURPOSE:To evaluate the 12-month U.S. phase II clinical trial results of the Crystalens AT-45 (eyeonics, Inc.) intraocular lens (IOL) used to provide uncorrected distance, intermediate, and near visual acuities in patients having cataract extraction and to compare in a substudy the contrast sensitivity and near visual acuity in patients with the Crystalens AT-45 IOL and those receiving a standard IOL. SETTING:Fourteen clinical sites throughout the U.S. for efficacy and 3 non-U.S. sites for safety and efficacy. METHODS:Patients 50 years or older had small-incision cataract extraction with implantation of the Crystalens AT-45 IOL. Unilateral implantation was followed by fellow-eye implantation. Postoperatively, uncorrected distance, near, and intermediate visual acuities were determined. Near and intermediate visual acuities were tested through a distance correction to eliminate potential pseudoaccommodative effects of residual myopia and corneal cylinder. A substudy tested contrast sensitivity under mesopic conditions with and without glare, as well as visual acuity in a subset of Crystalens AT-45 patients and a control group receiving a standard IOL. RESULTS:A total of 263 patients participated in the U.S. clinical trial and had 1 year of follow-up. Near visual acuities through the distance correction of 20/40 (J3) or better, monocularly and bilaterally, respectively, were seen in 90.1% and 100%; intermediate near visual acuities were seen in 99.6% and 100%. More than half the bilaterally implanted Crystalens AT-45 patients achieved uncorrected near acuity of 20/25 (J1) or better through the distance correction, and 84% achieved 20/32 (J2) or better. In the substudy, monocular near vision through the distance correction of 20/25 (J1) or better was seen in 50.4% with the Crystalens AT-45 IOL and in 4.7% with the standard IOLs. Mesopic contrast sensitivity results with and without glare for the Crystalens AT-45 were similar to those with standard monofocal IOLs. Nearly all patients (74 patients; 97.3%) who bilaterally were within 0.50 diopter of plano postoperatively achieved 20/32 (J2) or better uncorrected near, intermediate, and distance visual acuities. CONCLUSIONS:The Crystalens AT-45 accommodating IOL provided good uncorrected near, intermediate, and distance vision in pseudophakic patients. Contrast sensitivity with the Crystalens AT-45 was not diminished relative to standard monofocal IOLs, and near and intermediate visual performance was significantly better than with standard IOLs.
journal_name
J Cataract Refract Surgjournal_title
Journal of cataract and refractive surgeryauthors
Cumming JS,Colvard DM,Dell SJ,Doane J,Fine IH,Hoffman RS,Packer M,Slade SGdoi
10.1016/j.jcrs.2006.02.007subject
Has Abstractpub_date
2006-05-01 00:00:00pages
812-25issue
5eissn
0886-3350issn
1873-4502pii
S0886-3350(06)00153-2journal_volume
32pub_type
杂志文章,多中心研究abstract:PURPOSE:To evaluate the effect of a capsular tension ring (CTR) on the shape of the capsular bag, the extent of the capsular opening, and the shape of intraocular lenses (IOLs). SETTING:Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea. METHODS:The corneal button was rem...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(00)00610-6
更新日期:2001-03-01 00:00:00
abstract:PURPOSE:To validate clinically in a normal healthy population an algorithm to correct the error in the keratometric estimation of corneal power based on the use of a variable keratometric index of refraction (n(k)). SETTING:Medimar International Hospital (Oftalmar) and University of Alicante, Alicante, Spain. DESIGN:...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2012.03.026
更新日期:2012-08-01 00:00:00
abstract::A 76-year-old woman had sudden visual loss 9 years after an extracapsular cataract extraction with implantation of a poly(methyl methacrylate) disc intraocular lens (IOL) in the capsular bag. Slitlamp examination showed the disc IOL had luxated into the vitreous through a linear inferior opening in the capsular bag; t...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(99)80142-4
更新日期:1999-02-01 00:00:00
abstract:UNLABELLED:We describe an approach to transscleral fixation of a foldable posterior chamber intraocular lens (PC IOL) using a 25-gauge pars plana vitrectomy. The technique was used in 80 consecutive eyes, and the results were analyzed for corrected distance visual acuity and safety indicators. Postoperative complicatio...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2015.09.005
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To apply artificial intelligence models to predict the occurrence of posterior capsule opacification (PCO) after phacoemulsification. SETTING:Farabi Eye Hospital, Tehran, Iran. DESIGN:Clinical-based cross-sectional study. METHODS:The posterior capsule status of eyes operated on for age-related cataract and t...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2011.09.036
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:To evaluate an algorithm for corneal power estimation in intraocular lens (IOL) power calculation after myopic laser refractive surgery using direct corneal measurements. SETTING:International Vision Correction Research Centre, University of Heidelberg, Heidelberg, Germany. METHODS:Corneal parameters in norma...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2009.07.011
更新日期:2010-01-01 00:00:00
abstract::The first 45 cases of extracapsular cataract extraction, with posterior chamber intraocular lens implantation performed by ophthalmology residents at an urban county hospital were evaluated. These cases, which were performed from March 1983 to June 1984, involved a patient population that was primarily black and Hispa...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(86)80054-2
更新日期:1986-01-01 00:00:00
abstract::Measurement of laser in situ keratomileusis flap thickness is required to estimate residual bed thickness. Historically, flap thickness has been assumed, estimated based on microkeratome head labeling, guessed based on flap handling characteristics, or calculated by subtraction pachymetry. We describe a method for mea...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2006.01.003
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:To assess whether iris-claw intraocular lenses (IOLs) undergo gravitation-dependent changes in position and refraction. SETTING:Tertiary referral center, Bern, Switzerland. DESIGN:Observational case study. METHODS:Patients with a history of pars plana vitrectomy and IOL exchange with implantation of an aphak...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2016.07.033
更新日期:2016-10-01 00:00:00
abstract::A capsulorhexis may be difficult to perform in the absence of a red fundus reflex. Using 0.1 mL of trypan blue 0.1% to stain the anterior capsule in 30 patients with a mature cataract enabled us to visualize the capsulorhexis during phacoemulsification. No adverse reactions were observed up to 12 months after surgery....
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章
doi:10.1016/s0886-3350(99)80004-2
更新日期:1999-01-01 00:00:00
abstract:PURPOSE:To study the possible mechanisms of cataractogenesis by evaluating the characteristics of cataractous lens epithelial cells (LECs) in different types of human cataract. SETTING:Kangnam St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea. METHODS:Lens epithelial cells attached to the anterior c...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(99)00009-7
更新日期:1999-05-01 00:00:00
abstract::Horizontal chopping is effective for endocapsular nucleofractis. We describe pop and chop, a variant of chopping that enables an easy first crack and initial segment removal. It involves partial extracapsular prolapse of the nucleus prior to the initial chop. It is particularly useful when hydrodissection results in p...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(03)00339-0
更新日期:2003-11-01 00:00:00
abstract::This case outlines the phacoemulsification technique used to overcome the challenge of the hyperdeep anterior chamber, weak zonules, abnormal anterior capsule, and large capsular bag. Key steps included trypan blue staining of the anterior capsule, a large capsulorhexis, prolapse of the nucleus into the anterior chamb...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2005.12.143
更新日期:2006-07-01 00:00:00
abstract::We present a case of traumatic lens subluxation that was evident only when the patient was in the supine position. This case illustrates that a crystalline lens with traumatic zonular rupture can change its position depending on the posture of the patient. If such a lens is suspended by the remaining zonules at the su...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(01)01167-1
更新日期:2002-06-01 00:00:00
abstract:PURPOSE:To investigate the effect of surface modification of poly(methyl methacrylate) (PMMA) by poly(ethylene glycol) (PEG) grafting on cell adhesion. SETTING:Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea. METHODS:The PMMA surface was oxidized with ozone, and PEG acrylate was then gra...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(00)00701-x
更新日期:2001-05-01 00:00:00
abstract::A 48-year-old man with cataract had uncomplicated phacoemulsification and implantation of a posterior chamber intraocular lens (IOL) into the continuous capsulorhexis. Three years later, part of the capsular bag and a haptic subluxated into the anterior chamber. At the time of repositioning surgery, partial zonular de...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(97)80127-7
更新日期:1997-11-01 00:00:00
abstract:PURPOSE:To evaluate the long-term evolution of refractive error changes in eyes of children who have primary intraocular lens (IOL) implantation to allow more accurate prediction of what IOL power should be implanted at a given age. SETTING:Department of Ophthalmology, Indiana University School of Medicine, Indianapol...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(01)01156-7
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:To determine the appropriate correction of predicted intraocular lens (IOL) power for sulcus fixation and to prospectively assess the validity of the obtained correction value in patients having sulcus fixation. SETTING:Department of Ophthalmology, Saiseikai Kurihashi Hospital, Saitama, Japan. METHODS:The pos...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(03)00250-5
更新日期:2003-10-01 00:00:00
abstract:PURPOSE:To evaluate the efficacy of epithelial-disruption collagen crosslinking (CXL) for progressive keratoconus using a corneal disruptor device and a riboflavin solution designed for a transepithelial technique. SETTING:Magna Graecia University Eye Clinic, Catanzaro, Italy. DESIGN:Prospective comparative case seri...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2013.05.022
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:To evaluate the shift in keratoconus progression rate after corneal collagen crosslinking (CXL). SETTING:Chinese University of Hong Kong Eye Centre, Hong Kong, China. DESIGN:Prospective case series. METHOD:Accelerated epithelium-off CXL was performed in patients with progressive keratoconus. Optical coherenc...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2017.04.033
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:To compare the safety and efficacy of 0.025 mg/mL brilliant blue G (BBG) and an intracameral illuminator for visualizing the anterior capsule. SETTING:University-based tertiary referral center, South Korea. DESIGN:Retrospective cases series. METHODS:The medical records of patients with vitreous hemorrhage fo...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2016.03.038
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:To describe the indications, motivations, and outcomes of artificial iris exchange. SETTING:Stein Eye Institute. DESIGN:Consecutive case series. METHODS:Review of medical records of patients implanted with an artificial iris device who underwent a subsequent artificial iris exchange. RESULTS:Five patients w...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1097/j.jcrs.0000000000000321
更新日期:2020-12-01 00:00:00
abstract::In 1984, our ophthalmology department switched from intracapsular cataract extraction (ICCE) to extracapsular cataract extraction (ECCE). We reviewed the postoperative incidence of retinal detachment (RD) in two consecutive series: (1) 604 eyes operated on by ICCE from 1982 to 1983 and (2) 1726 eyes operated on by ECC...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80498-1
更新日期:1995-03-01 00:00:00
abstract:PURPOSE:To evaluate the formation of glistenings in foldable intraocular lenses (IOLs) of various materials after cataract surgery. SETTING:University Eye Clinic of Trieste, Trieste, Italy. METHODS:In this prospective study, 273 patients were randomized to have implantation of 1 of 7 types of foldable IOLs in the cap...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(02)01353-6
更新日期:2002-07-01 00:00:00
abstract::Recently, scleral fixation has been used in posterior chamber intraocular lens implantation in the absence of the posterior capsule. Fixation is achieved with a suture through the ciliary sulcus and sclera at a horizontal or vertical position. To achieve good functional results, the optical portion of the lens must li...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80585-8
更新日期:1994-05-01 00:00:00
abstract:PURPOSE:To evaluate forward light scattering and straylight in single-piece hydrophobic acrylic intraocular lenses (IOLs) (Acrysof) removed from cadaver eyes and design- and power-matched controls, as well as the effect of subsurface nanoglistenings on other optical quality and performance indicators. SETTING:John A. ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2015.07.043
更新日期:2016-01-01 00:00:00
abstract::There are optical and mechanical advantages of the biconvex posterior chamber intraocular lens (IOL) following cataract surgery. A clinical study of Nd:YAG laser capsulotomy in eyes with biconvex IOLs was undertaken. The lenses were made of injection-molded poly(methyl methacrylate) without laser spacing. Using specif...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(89)80065-3
更新日期:1989-07-01 00:00:00
abstract::Soon after the diagnosis of pellagra in a 20-year-old patient with beta thalassemia, bilateral intumescent cataracts rapidly developed. We believe the patient's crystalline lenses were at an increased oxidative state due to iron overload from the thalassemia. Depletion of the lens epithelial cells of an important anti...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2007.05.011
更新日期:2007-09-01 00:00:00
abstract::A method to measure the power of an intraocular lens (IOL) in situ using an extended range keratometer and a depth measuring apparatus is described. With this method, the IOL power was measured in ten patients with an anterior chamber IOL and in ten patients with a posterior chamber IOL and compared with the labeled p...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(88)80066-x
更新日期:1988-01-01 00:00:00
abstract::We report two cases in which hydrogel lens implants have dislocated posteriorly into the vitreous body following YAG laser capsulotomy. These lenses were placed in the bag in conjunction with a capsulorhexis. A comparison with our results using silicone and poly(methyl methacrylate) implants indicates that this phenom...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80770-5
更新日期:1990-09-01 00:00:00