Visual outcomes of a new toric trifocal diffractive intraocular lens.

Abstract:

PURPOSE:To evaluate the visual, refractive, contrast sensitivity, and aberrometric outcomes as well as the patient quality of life and photic phenomena disturbances after cataract surgery with implantation of a new trifocal toric intraocular lens (IOL). SETTINGS:Premium Clinic, Regional Hospital in Havlickuv Brod, Czech Republic, and Vissum and Universidad Miguel Hernández, Alicante, Spain. DESIGN:Prospective consecutive series of cases. METHODS:The study involved eyes with corneal astigmatism of 1.25 D or more that were having cataract surgery with implantation of the trifocal toric IOL AT Lisa tri toric 939MP (Carl Zeiss Meditec). Visual outcomes and astigmatic changes analyzed by Alpins vector analysis were evaluated at 3 months postoperatively. Contrast sensitivity, quality of life, and photic phenomena were also evaluated. RESULTS:The study involved a total of 30 eyes of 16 patients, age 37 to 64 years. A significant improvement with surgery was observed in uncorrected distance, intermediate, and near visual acuity (P ≤ .01). A significant decrease in the refractive cylinder was observed postoperatively (P < .01), with all eyes showing a postoperative astigmatism below 1.00 D. The difference between targeted and surgically induced astigmatism was small (0.06 ± 0.30 D) but statistically significant (P = .04). The mean magnitude of angle of error was 5.80 ± 8.47 degrees. The low levels of higher-order aberrations found postoperatively were consistent with the good levels of contrast sensitivity achieved. Regarding quality of life, low to moderate levels of difficulty in performing various types of vision-related tasks were found. CONCLUSIONS:The trifocal toric IOL evaluated provides effective restoration of visual function after cataract surgery, with associated high levels of visual acuities and quality of life. FINANCIAL DISCLOSURE:The authors have no proprietary or commercial interest in the medical devices that are involved in this manuscript.

authors

Mojzis P,Majerova K,Plaza-Puche AB,Hrckova L,Alio JL

doi

10.1016/j.jcrs.2015.07.033

subject

Has Abstract

pub_date

2015-12-01 00:00:00

pages

2695-706

issue

12

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(15)01168-2

journal_volume

41

pub_type

杂志文章
  • Thin flap laser in situ keratomileusis: flap dimensions with the Moria LSK-One manual microkeratome using the 100-microm head.

    abstract:PURPOSE:To determine the predictability and consistency of corneal flap thickness, flap diameter, and hinge length with the modern 100 microm head of the Moria LSK-One manual microkeratome. SETTING:Private clinic, office-based practice. METHODS:Forty-two consecutive eyes with no previous surgery having thin flap lase...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.10.056

    authors: Duffey RJ

    更新日期:2005-06-01 00:00:00

  • European clinical evaluation: use of Intacs for the treatment of keratoconus.

    abstract:PURPOSE:To evaluate the safety and efficacy of Intacs inserts in keratoconic eyes to alter corneal shape and refractive power and stabilize the progression of corneal ectasia. SETTING:Service d'Ophtalmologie, Bordeaux, France. METHODS:In this prospective study, 57 eyes with clear central corneas that were diagnosed w...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jcrs.2006.01.064

    authors: Colin J

    更新日期:2006-05-01 00:00:00

  • Accuracy, repeatability, and reproducibility of Artemis very high-frequency digital ultrasound arc-scan lateral dimension measurements.

    abstract:PURPOSE:To determine the accuracy, repeatability, and reproducibility of measurement of lateral dimensions using the Artemis (Ultralink LLC) very high-frequency (VHF) digital ultrasound (US) arc scanner. SETTING:London Vision Clinic, London, United Kingdom. METHODS:A test object was measured first with a micrometer a...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.07.017

    authors: Reinstein DZ,Archer TJ,Silverman RH,Coleman DJ

    更新日期:2006-11-01 00:00:00

  • Preliminary study of argon fluoride (193 nm) excimer laser trabeculectomy. Scanning electron microscopy at five months.

    abstract::There is an increasing interest in the use of the excimer laser in ophthalmology, particularly in refractive surgery. The argon fluoride (193 nm) excimer laser ablates tissue with a high degree of precision and without any mechanical or thermal damage to surrounding structures. In this study, the argon fluoride excime...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80780-8

    authors: Aron-Rosa D,Maden A,Ganem S,Aron B,Gross M

    更新日期:1990-09-01 00:00:00

  • Fluorescence-guided laser removal of chemically damaged cornea.

    abstract:PURPOSE:To correlate the observed fluorescence spectrum with the depth of ablation during 193 nm argon-fluoride excimer laser ablation of chemically damaged corneas. SETTING:Laser facility, Cedars-Sinai Medical Center, Los Angeles, California, USA. METHODS:Three cadaver New Zealand white rabbit corneas were exposed t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01361-5

    authors: Chuck RS,Arnoldussen ME,Behrens A,Sweet PM,Bearman GH,Grundfest WS

    更新日期:2002-10-01 00:00:00

  • Impact of intraocular lens material and design on light scatter: In vitro study.

    abstract:PURPOSE:To determine the typical in vitro straylight levels for intraocular lenses (IOLs) of different materials and designs. SETTING:Abbott Medical Optics, Inc., Groningen, the Netherlands. DESIGN:Experimental study. METHODS:Two optical bench setups were used to determine baseline straylight levels of IOLs placed i...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.10.017

    authors: Langeslag MJ,van der Mooren M,Beiko GH,Piers PA

    更新日期:2014-12-01 00:00:00

  • Impact of cataract surgery on self-reported visual difficulties: comparison with a no-surgery reference group.

    abstract:PURPOSE:To examine the impact of cataract surgery on older adults' self-reported visual difficulties and compare them with those of patients with cataract who declined surgery over the same period. SETTING:Twelve area practices. METHODS:This was a consecutive chart review over a 6-month period. Primary inclusion crit...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/s0886-3350(02)01846-1

    authors: McGwin G Jr,Scilley K,Brown J,Owsley C

    更新日期:2003-05-01 00:00:00

  • Trocar anterior chamber maintainer: Improvised infusion technique.

    abstract:UNLABELLED:We present an improvised technique of infusion that uses a trocar cannula as an anterior chamber maintainer (ACM). Although routinely used in posterior segment surgery, the trocar cannula has been infrequently used in complex anterior segment procedures. The trocar ACM creates a transconjunctival biplanar wo...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.01.015

    authors: Agarwal A,Narang P,Kumar DA,Agarwal A

    更新日期:2016-02-01 00:00:00

  • Epidemiology of retinal detachment following extracapsular cataract extraction: a follow-up study with an analysis of risk factors.

    abstract::We reviewed the medical records of 1,726 eyes consecutively operated on with extracapsular cataract extraction to examine the incidence of and the risk factors for retinal detachment (RD). In Denmark, both diagnoses and deaths are registered centrally; therefore, a complete follow-up was achieved in each case and actu...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80333-1

    authors: Nielsen NE,Naeser K

    更新日期:1993-11-01 00:00:00

  • Implantation of an Artisan iris-fixated phakic intraocular lens for the correction of hyperopia, a 15 year follow-up.

    abstract:PURPOSE:To assess the predictability, efficacy, stability and safety of implantation of an Artisan (Ophtec BV, the Netherlands) iris-fixated phakic intraocular lens (IF-pIOL) for the correction of hyperopia with a follow-up of up to 15 years. SETTING:Leiden University Medical Center, The Netherlands METHODS:: Patients...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000532

    authors: van Rijn GA,Gaurisankar ZS,Saxena R,Gibbes D,Jongman HP,Haasnoot GW,Cheng YYY,Beenakker JM,Luyten GPM

    更新日期:2020-11-27 00:00:00

  • Continuous curvilinear capsulorhexis with use of an endoscope.

    abstract::We describe a technique for creating a continuous curvilinear capsulorhexis (CCC) using an endoscope. Three 2.0 mm limbal incisions 120 degrees apart were made in 4 cadaver eyes. The anterior capsule was stained with trypan blue 0.1% (Vision Blue). Under endoscopic visualization, a CCC was attempted in each of the 4 g...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.09.051

    authors: Moore JE,Herath GD,Sharma A

    更新日期:2004-05-01 00:00:00

  • An algorithm for the preoperative diagnosis and treatment of ocular surface disorders.

    abstract::Any ocular surface disease (OSD), but most commonly, dry-eye disease (DED), can reduce visual quality and quantity and adversely affect refractive measurements before keratorefractive and phacorefractive surgeries. In addition, ocular surgery can exacerbate or induce OSD, leading to worsened vision, increased symptoms...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,评审

    doi:10.1016/j.jcrs.2019.03.023

    authors: Starr CE,Gupta PK,Farid M,Beckman KA,Chan CC,Yeu E,Gomes JAP,Ayers BD,Berdahl JP,Holland EJ,Kim T,Mah FS,ASCRS Cornea Clinical Committee.

    更新日期:2019-05-01 00:00:00

  • Capsular peeling in anterior capsule contraction syndrome: surgical approach and histopathological aspects.

    abstract::We present 4 cases of anterior capsule contraction syndrome in which progressive shrinkage of the anterior capsulorhexis developed after uneventful phacoemulsification. Three eyes were pseudophakic, and 1 eye remained aphakic. The newly formed membrane was surgically peeled from the anterior capsule, restoring the cap...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.08.034

    authors: Reyntjens B,Tassignon MJ,Van Marck E

    更新日期:2004-04-01 00:00:00

  • Reproducibility of LASIK flap thickness using the Hansatome microkeratome.

    abstract:PURPOSE:To evaluate the actual versus the expected thickness of laser in situ keratomileusis (LASIK) flaps and to determine the factors that affect flap thickness. SETTING:Centre For Sight, Queen Victoria Hospital, East Grinstead, United Kingdom. METHODS:A retrospective analysis of LASIK procedures in 757 consecutive...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.09.070

    authors: Giledi O,Mulhern MG,Espinosa M,Kerr A,Daya SM

    更新日期:2004-05-01 00:00:00

  • Reopening of 2 macular holes after neodymium:YAG capsulotomy.

    abstract::We report 2 cases of reopening of macular holes after successful neodymium:YAG (Nd:YAG) posterior capsulotomy. Both patients had surgery for closure of macular holes with recovery of visual acuity. To our knowledge, this is the first report of recurrent macular holes after Nd:YAG laser posterior capsulotomy treated su...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.07.020

    authors: García-Arumí J,Palau MM,Espax AB,Martínez-Castillo V,Garrido HB,Corcóstegui B

    更新日期:2006-02-01 00:00:00

  • Intacs insertion with the femtosecond laser for the management of keratoconus: one-year results.

    abstract:PURPOSE:To assess the outcomes of intrastromal ring segment (Intacs, Addition Technology) implantation for keratoconus using the femtosecond laser. SETTING:Kudret Eye Hospital, Ankara, Turkey. METHODS:In a retrospective noncomparative case series, 118 eyes of 69 patients with keratoconus who had Intacs segments impla...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.08.032

    authors: Ertan A,Kamburoğlu G,Bahadir M

    更新日期:2006-12-01 00:00:00

  • Phacoemulsification with corneal astigmatism correction with the use of a toric intraocular lens in a case of megalocornea.

    abstract::We report the case of a 49-year-old patient with megalocornea and coexisting corneal astigmatism. The corneal diameter in the right eye was 15.0 mm and in the left eye, 14.9 mm. In both eyes, a nuclear sclerotic cataract developed, with the tendency toward cortical mass swelling in the right eye. The aim of surgical t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.04.023

    authors: Rękas M,Pawlik R,Kluś A,Różycki R,Szaflik JP,Ołdak M

    更新日期:2011-08-01 00:00:00

  • Transscleral fixation of foldable intraocular lenses.

    abstract:PURPOSE:To report the results of transscleral implantation of foldable intraocular lenses (IOLs). SETTING:Department of Ophthalmology Dokuz Eylül University School of Medicine, Izmir, Turkey. METHODS:Twenty eyes of 20 patients had transscleral fixation of a foldable IOL combined with conventional 3-port pars plana vi...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.09.050

    authors: Kaynak S,Ozbek Z,Pasa E,Oner FH,Cingil G

    更新日期:2004-04-01 00:00:00

  • Effect of cataract on corneal topography results.

    abstract::This report details the case of a 65-year-old man with advanced cataract in which there was a large discrepancy between the K-readings taken with a keratometer and those taken with a TMS-1 videokeratoscope. It was suspected the discrepancy was caused by the advanced cataract in the presence of a dilated pupil. Repeat ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80155-6

    authors: Singh D

    更新日期:1996-12-01 00:00:00

  • Photorefractive keratectomy with intraoperative mitomycin-C application.

    abstract:PURPOSE:To evaluate the efficacy and safety of photorefractive keratectomy (PRK) with intraoperative application of mitomycin-C (MMC). SETTING:Yonsei Eye Center, Seoul, South Korea. METHODS:This retrospective noncomparative case series included 536 patients (1011 eyes) who had had PRK with intraoperative application ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.05.027

    authors: Lee DH,Chung HS,Jeon YC,Boo SD,Yoon YD,Kim JG

    更新日期:2005-12-01 00:00:00

  • Visual performance after bilateral toric extended depth-of-focus intraocular lens exchange targeted for micro-monovison.

    abstract:PURPOSE:To evaluate overall patient satisfaction, spectacle independence, binocular visual acuity, rotational stability, prevalence of optical phenomena, as well as decentration and tilt after bilateral toric extended depth-of-focus intraocular lens (EDOF IOL) implantation targeted for micromonovision. SETTING:Departm...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000290

    authors: Georgiev S,Palkovits S,Hirnschall N,Döller B,Draschl P,Findl O

    更新日期:2020-06-22 00:00:00

  • Intraocular lens power calculation in eyes with keratoconus.

    abstract:PURPOSE:To assess the refractive accuracy of different formulas for intraocular lens (IOL) power calculation in eyes with keratoconus. SETTING:IRCCS Fondazione Bietti, Rome, Italy. DESIGN:Multicenter retrospective interventional study. METHODS:A consecutive series of eyes with keratoconus that had cataract surgery w...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jcrs.2018.11.029

    authors: Savini G,Abbate R,Hoffer KJ,Mularoni A,Imburgia A,Avoni L,D'Eliseo D,Schiano-Lomoriello D

    更新日期:2019-05-01 00:00:00

  • Cataract surgery in patients with left ventricular assist device support.

    abstract:UNLABELLED:Left ventricular assist devices (LVADs) have been increasingly used for 20 years in terminally ill patients with advanced heart failure or awaiting cardiac transplantation. Despite improvement in morbidity and mortality from use of these devices, quality of life may be limited by cataract. Access to cataract...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.01.024

    authors: Eghrari AO,Rivers RJ,Alkharashi M,Rajaii F,Nyhan D,Sikder S

    更新日期:2014-04-01 00:00:00

  • Femtosecond laser in situ keratomileusis after radial keratotomy.

    abstract:PURPOSE:To assess the safety, efficacy, and predictability of femtosecond laser in situ keratomileusis (LASIK) in eyes with previous radial keratotomy (RK). SETTING:Hospital Virgen del Consuelo de Valencia, Valencia, and Vissum Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS:This prospective study compr...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.02.061

    authors: Muñoz G,Albarrán-Diego C,Sakla HF,Pérez-Santonja JJ,Alió JL

    更新日期:2006-08-01 00:00:00

  • Small-aperture intraocular lens combined with secondary piggyback intraocular lens during cataract surgery after previous radial keratotomy.

    abstract::A 73-year-old woman with bilateral previous radial keratotomies (RK) and symptomatic cataracts was referred. The uncorrected distance visual acuity (UDVA) was 0.24 logarithm of the minimum angle of resolution (logMAR) in the left eye and 0.32 logMAR in the left eye. The American Society of Cataract and Refractive Surg...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.06.005

    authors: Barnett V,Barsam A,Than J,Srinivasan S

    更新日期:2018-08-01 00:00:00

  • Technique to exclude temporal lash incursion in phacoemulsification surgery.

    abstract:UNLABELLED:We describe the use of a Steri-Strip to exclude lashes in cataract surgery cases in which the lashes impinge on the operative field. The technique has been used in 25 cases and achieved uniformly successful lash exclusion. In 6 cases, the strip became partially dislodged and required repositioning intraopera...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2012.09.005

    authors: Fox OJ,Sim BW,Win S,Singh R,Amjadi S,Agar A,Bank A,Francis IC

    更新日期:2012-11-01 00:00:00

  • Characteristics of ocular higher-order aberrations in patients with pellucid marginal corneal degeneration.

    abstract:PURPOSE:To evaluate the characteristics of higher-order aberrations (HOAs) in eyes with pellucid marginal corneal degeneration (PMCD). SETTING:Department of Ophthalmology, Osaka University Medical School, Osaka, Japan. METHODS:Ocular HOAs were measured by aberrometry in 20 eyes with PMCD (PMCD group), 76 eyes with ke...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.06.038

    authors: Oie Y,Maeda N,Kosaki R,Suzaki A,Hirohara Y,Mihashi T,Hori Y,Inoue T,Nishida K,Fujikado T,Tano Y

    更新日期:2008-11-01 00:00:00

  • Capsulorhexis contraction after cataract surgery: comparison of sharp anterior edge and modified anterior edge acrylic intraocular lenses.

    abstract:PURPOSE:To evaluate the reduction in the anterior capsule opening after phacoemulsification, continuous curvilinear capsulorhexis, and implantation of 1 of 2 acrylic intraocular lenses (IOLs). SETTING:Department of Ophthalmology, Vejle Hospital, Vejle, Denmark. METHODS:Eighty-four patients (84 eyes) were included in ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2007.01.020

    authors: Corydon C,Lindholt M,Knudsen EB,Graakjaer J,Corydon TJ,Dam-Johansen M

    更新日期:2007-05-01 00:00:00

  • Biomechanical parameters of the cornea after collagen crosslinking measured by waveform analysis.

    abstract:PURPOSE:To compare 2 corneal biomechanical parameters--corneal hysteresis (CH) and corneal resistance factor (CRF)--before and after collagen crosslinking (CXL) for keratoconus. SETTING:Eye Research Center of Mashhad University of Medical Sciences, Khatam-al-Anbia Eye Hospital, Mashhad, and Department of Ophthalmology...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.06.056

    authors: Sedaghat M,Naderi M,Zarei-Ghanavati M

    更新日期:2010-10-01 00:00:00

  • Validation of a handheld automated keratometer in adults.

    abstract:PURPOSE:To evaluate the Nidek handheld automated keratometer and compare it with the manual Zeiss keratometer. SETTING:St. Paul's Eye Unit, Royal Liverpool University Hospital, Liverpool, United Kingdom. METHODS:Forty-five normal adult volunteers were included in the study. Three sets of randomized keratometry measur...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(98)80333-7

    authors: Noonan CP,Rao GP,Kaye SB,Green JR,Chandna A

    更新日期:1998-03-01 00:00:00