Abstract:
:Scatterer properties like the average effective scatterer diameter and acoustic concentration were determined in vivo using a quantitative ultrasound (QUS) technique from two tumor phenotypes grown in animal models. These tumor models included spontaneously occurring mammary fibroadenomas in rats and transplanted 4T1 mammary carcinomas in mice. The scatterer properties of average scatterer diameter and acoustic concentration were estimated using a Gaussian form factor from the backscattered ultrasound measured from both types of tumors. QUS images of the tumors were constructed utilizing estimated scatterer properties from regions in the tumors. The QUS images showed a clear distinction between the two types of tumors and a statistically significant difference existed between their estimated scatterer properties. The average scatterer diameter and acoustic concentration for the mammary fibroadenomas were estimated to be 105 +/- 25 microm and -15.6 +/- 5 dB(mm(-3)), respectively. The average scatterer diameter and acoustic concentration for the carcinomas was estimated to be 28 +/- 4.6 microm and 10.6 +/- 6.9 dB(mm(-3)), respectively. The distinctions in the scattering properties are clearly seen in the QUS images of the tumors and indicate that QUS imaging can be useful in differentiating between different types of mammary tumors.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Oelze ML,O'Brien WD Jr,Blue JP,Zachary JFdoi
10.1109/tmi.2004.826953subject
Has Abstractpub_date
2004-06-01 00:00:00pages
764-71issue
6eissn
0278-0062issn
1558-254Xjournal_volume
23pub_type
杂志文章abstract::Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense compu...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2253117
更新日期:2013-07-01 00:00:00
abstract::The problem of automatic quantification of brain tissue by utilizing single-valued (single echo) magnetic resonance imaging (MRI) brain scans is addressed. It is shown that this problem can be solved without classification or segmentation, a method that may be particularly useful in quantifying white matter lesions wh...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.241885
更新日期:1993-01-01 00:00:00
abstract::True three-dimensional (3-D) volume reconstruction from fully 3-D data in positron emission tomography (PET) has only a limited clinical use because of its large computational burden. Fourier rebinning (FORE) of the fully 3-D data into a set of 2-D sinogram data decomposes the 3-D reconstruction process into multiple ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.870257
更新日期:2000-05-01 00:00:00
abstract::Within-subject analysis in fMRI essentially addresses two problems, the detection of brain regions eliciting evoked activity and the estimation of the underlying dynamics. In Makni et aL, 2005 and Makni et aL, 2008, a detection-estimation framework has been proposed to tackle these problems jointly, since they are con...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2042064
更新日期:2010-04-01 00:00:00
abstract::For certain medical applications resampling of data is required. In magnetic resonance tomography (MRT) or computer tomography (CT), e.g., data may be sampled on nonrectilinear grids in the Fourier domain. For the image reconstruction a convolution-interpolation algorithm, often called gridding, can be applied for res...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.774166
更新日期:1999-05-01 00:00:00
abstract::Many segmentation methods for thoracic volume data require manual input in the form of a seed point, initial contour, volume of interest etc. The aim of the work presented here is to further automate this segmentation initialization step. In this paper an anatomical modeling and matching method is proposed to coarsely...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.764893
更新日期:1999-03-01 00:00:00
abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.56340
更新日期:1990-01-01 00:00:00
abstract::Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.884190
更新日期:2006-12-01 00:00:00
abstract::Interpretation of magnetic resonance angiography (MRA) is problematic due to complexities of vascular shape and to artifacts such as the partial volume effect. We present new methods to assist in the interpretation of MRA. These include methods for detection of vessel paths and for determination of branching patterns ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章,评审
doi:10.1109/42.870662
更新日期:2000-06-01 00:00:00
abstract::X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using l...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2823768
更新日期:2018-06-01 00:00:00
abstract::Deep learning is becoming an indispensable tool for various tasks in science and engineering. A critical step in constructing a reliable deep learning model is the selection of a loss function, which measures the discrepancy between the network prediction and the ground truth. While a variety of loss functions have be...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3031913
更新日期:2020-10-19 00:00:00
abstract::Computerized detection of clustered microcalcifications (MCs) in mammograms often suffers from the occurrence of false positives (FPs), which can vary greatly from case to case. We investigate how to apply statistical estimation to determine the number of FPs that are present in a detected MC lesion. First, we describ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2654799
更新日期:2017-05-01 00:00:00
abstract::The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2142188
更新日期:2011-09-01 00:00:00
abstract::Respiratory motion remains a significant source of errors in treatment planning for the thorax and upper abdomen. Recently, we proposed a method to estimate two-dimensional (2-D) object motion from a sequence of slowly rotating X-ray projection views, which we called deformation from orbiting views (DOVs). In this met...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.889719
更新日期:2007-02-01 00:00:00
abstract::Spectral computed tomography (CT) is a promising technique with the potential for improving lesion detection, tissue characterization, and material decomposition. In this paper, we are interested in kVp switching-based spectral CT that alternates distinct kVp X-ray transmissions during gantry rotation. This system can...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2380993
更新日期:2015-03-01 00:00:00
abstract::Measures of vascular tortuosity-how curved and twisted a vessel is-are associated with a variety of vascular diseases. Consequently, measurements of vessel tortuosity that are accurate and comparable across modality, resolution, and size are greatly needed. Yet in practice, precise and consistent measurements are prob...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3025467
更新日期:2021-01-01 00:00:00
abstract::Ultrafast ultrasound imaging using plane or diverging waves, instead of focused beams, has advanced greatly the development of novel ultrasound imaging methods for evaluating tissue functions beyond anatomical information. However, the sonographic signal-to-noise ratio (SNR) of ultrafast imaging remains limited due to...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2781261
更新日期:2018-04-01 00:00:00
abstract::An optical model for imaging the retina through cataracts has been developed. The images are treated as sample functions of stochastic processes. On the basis of the model a homomorphic Weiner filter can be designed that will optimally restore the cataractous image (in the mean-square-error sense). The design of the f...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.41493
更新日期:1989-01-01 00:00:00
abstract::Imaging systems that form estimates using a statistical approach generally yield images with nonuniform resolution properties. That is, the reconstructed images possess resolution properties marked by space-variant and/or anisotropic responses. We have previously developed a space-variant penalty for penalized-likelih...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.823063
更新日期:2004-03-01 00:00:00
abstract::Image guided interventions have seen growing interest in recent years. The use of X-rays for the procedure impels limiting the dose over time. Image sequences obtained thereby exhibit high levels of noise and very low contrasts. Hence, the development of efficient methods to enable optimal visualization of these seque...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2349034
更新日期:2015-01-01 00:00:00
abstract::Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Registration of 3-D ul...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.918326
更新日期:2008-10-01 00:00:00
abstract::Regularization is desirable for image reconstruction in emission tomography. A powerful regularization method is the penalized-likelihood (PL) reconstruction algorithm (or equivalently, maximum a posteriori reconstruction), where the sum of the likelihood and a noise suppressing penalty term (or Bayesian prior) is opt...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.816960
更新日期:2003-09-01 00:00:00
abstract::Previous work has shown that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this paper investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structu...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2911482
更新日期:2020-02-01 00:00:00
abstract::This paper describes the implementation of a novel and robust threshold energy calibration method for photon counting detectors using polychromatic X-ray tubes. Methods often used for such energy calibration may require re-orientation of the detector or introduce calibration errors that are flux and acquisition time-d...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2875932
更新日期:2019-04-01 00:00:00
abstract::In Soares et al. (2000), the ensemble statistical properties of the rescaled block-iterative expectation-maximization (RBI-EM) reconstruction algorithm and rescaled block-iterative simultaneous multiplicative algebraic reconstruction technique (RBI-SMART) were derived. Included in this analysis were the special cases ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2004.836876
更新日期:2005-01-01 00:00:00
abstract::One-dimensional (1-D) linear transducer arrays can be used for three-dimensional (3-D) ultrasound image acquisition. However, the relatively low spatial resolution of these arrays in the elevation direction results in blurry 3-D images. Here, the authors introduce an elevation direction deconvolution (EDD) method that...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.500148
更新日期:1996-01-01 00:00:00
abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2504240
更新日期:2016-04-01 00:00:00
abstract::To reconstruct electrical activity in the heart from body-surface electrocardiograms (ECGs) is an ill-posed inverse problem. Electrophysiological models have been found effective in regularizing these inverse problems by incorporating a priori knowledge about how the electrical potential in the heart propagates over t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2906600
更新日期:2019-11-01 00:00:00
abstract::High-resolution functional imaging of small animals is often obtained by single pinhole SPECT with circular orbit acquisition. Multipinhole SPECT adds information due to its improved sampling, and can improve the trade-off between resolution and sensitivity. To evaluate different pinhole collimator designs an efficien...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.902802
更新日期:2008-01-01 00:00:00
abstract::A novel splat feature classification method is presented with application to retinal hemorrhage detection in fundus images. Reliable detection of retinal hemorrhages is important in the development of automated screening systems which can be translated into practice. Under our supervised approach, retinal color images...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2227119
更新日期:2013-02-01 00:00:00