Transrectal and transvaginal ultrasonography in the preoperative staging of rectal carcinoma.

Abstract:

:To evaluate the diagnostic ability of transrectal and transvaginal ultrasonography (TRUS and TVUS), 132 patients with rectal carcinoma were examined. Analysis of the data obtained has shown that the high quality of endosonographic imaging allows the performance of detailed staging of rectal carcinoma. In the great majority of patients (91%) the staging was carried out correctly. Neoplastic invasion was overstaged in only five cases and understaged in another five cases. Altered pararectal lymph nodes could be visualized by endosonographic examination in 54.5% of patients.

journal_name

Eur J Radiol

authors

Fedyaev EB,Volkova EA,Kuznetsova EE

doi

10.1016/0720-048x(95)00616-x

subject

Has Abstract

pub_date

1995-05-01 00:00:00

pages

35-8

issue

1

eissn

0720-048X

issn

1872-7727

pii

0720-048X(95)00616-X

journal_volume

20

pub_type

杂志文章
  • Diagnostic strategies in spinal trauma.

    abstract::Spinal injuries may result in severe neurological deficits, especially if nerve roots or even the spinal cord are affected. Besides presenting the important anatomical and technical basis underlying the imaging findings of spinal injuries, the trauma mechanisms and the resulting injuries are discussed. Based on the cu...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2005.12.007

    authors: Heinemann U,Freund M

    更新日期:2006-04-01 00:00:00

  • The rate of breast fibroglandular enhancement during dynamic contrast-enhanced MRI reflects response to neoadjuvant therapy.

    abstract:PURPOSE:This study assesses the rate of enhancement of breast fibroglandular tissue after administration of a magnetic resonance imaging (MRI) gadolinium-based contrast agent and determines its relationship with response to neoadjuvant therapy (NAT) in women with breast cancer. METHOD:Women with locally advanced breas...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2021.109534

    authors: Virostko J,Kuketz G,Higgins E,Wu C,Sorace AG,DiCarlo JC,Avery S,Patt D,Goodgame B,Yankeelov TE

    更新日期:2021-01-09 00:00:00

  • CT evaluation of the low severity cervical spine trauma: when is the scout view enough?

    abstract::The aim of the current study was to compare the diagnostic information obtained from a helical CT examination in low severity cervical spine trauma with that from a lateral CT scout view. We included alert and clinically stable patients, who had suffered acute blunt trauma of low or moderate severity. Their scout imag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.024

    authors: Theocharopoulos N,Chatzakis G,Karantanas A,Chlapoutakis K,Damilakis J

    更新日期:2010-07-01 00:00:00

  • Role of CT colonography in inflammatory bowel disease.

    abstract::CT colonography (CTC), or virtual colonoscopy, is a non-invasive imaging method that uses CT data sets combined with specialized imaging software to examine the colon. CTC is not used routinely in patients with inflammatory bowel disease (IBD). However, investigating contemporarily the colon, other abdominal organs an...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2008.11.027

    authors: Regge D,Neri E,Turini F,Chiara G

    更新日期:2009-03-01 00:00:00

  • Quantitative analysis of the dual-energy CT virtual spectral curve for focal liver lesions characterization.

    abstract:OBJECTIVE:To assess the usefulness of the spectral curve slope of dual-energy CT (DECT) for differentiating between hepatocellular carcinoma (HCC), hepatic metastasis, hemangioma (HH) and cysts. METHODS:In total, 121 patients were imaged in the portal venous phase using dual-energy mode. Of these patients, 23 patients...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.07.009

    authors: Wang Q,Shi G,Qi X,Fan X,Wang L

    更新日期:2014-10-01 00:00:00

  • ¹⁸F-fluorodeoxyglucose uptake on positron emission tomography in mucinous adenocarcinoma.

    abstract:BACKGROUND:The prognostic value of maximum standardized uptake value (maxSUV) on (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) is known for localized pulmonary adenocarcinoma, which is most commonly non-mucinous adenocarcinoma. We examined the validity of thin-section computed tomography (TS-CT) and F...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.07.028

    authors: Murakami S,Saito H,Karino F,Kondo T,Oshita F,Ito H,Nakayama H,Yokose T,Yamada K

    更新日期:2013-11-01 00:00:00

  • COV is a readily available quantitative indicator of metabolic heterogeneity for predicting survival of patients with early and locally advanced NSCLC manifesting as central lung cancer.

    abstract:OBJECTIVES:The aim of our study was to investigate the value of a simple metabolic heterogeneity parameter, COV (coefficient of variation), by 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in the prognosis prediction of central lung cancer in early and locally advanced non-small-cell lung cancer (NSC...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109338

    authors: Yu T

    更新日期:2020-11-01 00:00:00

  • Screening US and CT for blunt abdominal trauma: a retrospective study.

    abstract:OBJECTIVE:To assess the accuracy of screening US and CT in patients with blunt abdominal trauma admitted to the trauma centre of our General Hospital. MATERIALS AND METHOD:The abdominal US reports of 864 primary trauma patients (139 with major and 725 with minor injuries) and 162 CT reports of a subgroup of the same s...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2005.02.001

    authors: Marco GG,Diego S,Giulio A,Luca S

    更新日期:2005-10-01 00:00:00

  • Observer agreement in the reporting of knee and lumbar spine magnetic resonance (MR) imaging examinations: selectively trained MR radiographers and consultant radiologists compared with an index radiologist.

    abstract:PURPOSE:To assess agreement between trained radiographers and consultant radiologists compared with an index radiologist when reporting on magnetic resonance imaging (MRI) examinations of the knee and lumbar spine and to examine the subsequent effect of discordant reports on patient management and outcome. METHODS:At ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.05.024

    authors: Brealey S,Piper K,King D,Bland M,Caddick J,Campbell P,Gibbon A,Highland A,Jenkins N,Petty D,Warren D

    更新日期:2013-10-01 00:00:00

  • MR imaging evaluation of endoscopic cranial base reconstruction with pedicled nasoseptal flap following endoscopic endonasal skull base surgery.

    abstract:INTRODUCTION:Postoperative CSF leak is the most common complication of endoscopic endonasal approach (EEA) to skull base lesions. Endoscopic multilayer closure of skull base defect using pedicled nasoseptal flaps (NSF) based off the sphenopalatine artery reduces CSF leaks. EEA robustly expands in surgical arena, yet po...

    journal_title:European journal of radiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.ejrad.2012.09.029

    authors: Learned KO,Adappa ND,Loevner LA,Palmer JN,Newman JG,Lee JY

    更新日期:2013-03-01 00:00:00

  • MRI of orofacial tumors and paragangliomas with 2D GE sequences: indications and optimal sequence parameters.

    abstract::The aim of this paper is to determine to what extent and in which cases 2D gradient echo (2D GE) sequences can be applied alternatively or additionally to spin echo (SE) sequences for improved diagnostic evaluation. Imaging with SE sequences is the most frequently used MR technique in the assessment of ear, nose and t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(94)90364-6

    authors: Held P

    更新日期:1994-02-01 00:00:00

  • Multiple simultaneous percutaneous needle biopsy (MSPNB) technique for masses of the abdomen and peritoneum.

    abstract::A technique for the biopsy of abdominal masses consisting of the simultaneous insertion of multiple needles is described. This technique was employed in 45 patients. The results were compared with the author's preceding experience with 32 cases performed with a conventional technique of sequential biopsies. Adequate s...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Morettin LB,Brown RW,Amparo EG,Matteson R

    更新日期:1987-05-01 00:00:00

  • Automatic coronary calcium scoring in chest CT using a deep neural network in direct comparison with non-contrast cardiac CT: A validation study.

    abstract:PURPOSE:To evaluate deep-learning based calcium quantification on Chest CT scans compared with manual evaluation, and to enable interpretation in terms of the traditional Agatston score on dedicated Cardiac CT. METHODS:Automated calcium quantification was performed using a combination of deep-learning convolution neur...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109428

    authors: van Assen M,Martin SS,Varga-Szemes A,Rapaka S,Cimen S,Sharma P,Sahbaee P,De Cecco CN,Vliegenthart R,Leonard TJ,Burt JR,Schoepf UJ

    更新日期:2021-01-01 00:00:00

  • Gastric leiomyosarcoma in a child.

    abstract::Gastric leiomyosarcoma is a rare tumor in pediatric patients. The histological differentiation between leiomyoma and leiomyosarcoma is difficult. Computed tomography may allow the presumptive diagnosis of leiomyosarcoma to be made preoperatively and the surgical treatment can be planned in advance. We report a case of...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(96)01060-1

    authors: Jaeger HJ,Schmitz-Stolbrink A,Albrecht M,Mathias K

    更新日期:1996-09-01 00:00:00

  • Shear wave elastography of thyroid nodules for the prediction of malignancy in a large scale study.

    abstract:OBJECTIVES:The purpose of this study is to validate the usefulness of shear wave elastography (SWE) in predicting thyroid malignancy with a large-scale quantitative SWE data. METHODS:This restrospective study included 476 thyroid nodules in 453 patients who underwent gray-scale US and SWE before US-guided fine-needle ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.11.019

    authors: Park AY,Son EJ,Han K,Youk JH,Kim JA,Park CS

    更新日期:2015-03-01 00:00:00

  • Diffusion weighted MRI and 18F-FDG PET/CT in non-small cell lung cancer (NSCLC): does the apparent diffusion coefficient (ADC) correlate with tracer uptake (SUV)?

    abstract:INTRODUCTION:To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). MATERIALS AND METHODS:18F-FDG PET/CT and DWI (TR/TE, 200...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.11.050

    authors: Regier M,Derlin T,Schwarz D,Laqmani A,Henes FO,Groth M,Buhk JH,Kooijman H,Adam G

    更新日期:2012-10-01 00:00:00

  • Lymphatic interventions for isolated, iatrogenic chylous ascites: A multi-institution experience.

    abstract:OBJECTIVES:Lymphangiography and thoracic duct embolization are established treatments for post-surgical chylothorax. There is only limited experience in their application to treat post-surgical chylous ascites. A multi-center analysis of the technical and clinical success of lymphangiography and lymphatic interventions...

    journal_title:European journal of radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.ejrad.2018.10.019

    authors: Majdalany BS,Khayat M,Downing T,Killoran TP,El-Haddad G,Khaja MS,Saad WA

    更新日期:2018-12-01 00:00:00

  • Contrast enhanced ultrasound in liver imaging.

    abstract::Ultrasound contrast agents were originally introduced to enhance the Doppler signals when detecting vessels with low velocity flow or when imaging conditions were sub-optimal. Contrast agents showed additional properties, it was discovered that a parenchymal enhancement phase in the liver followed the enhancement of t...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2004.03.022

    authors: Nielsen MB,Bang N

    更新日期:2004-06-01 00:00:00

  • 18F-FDG PET, combined FDG-PET/CT and MRI for evaluation of bone marrow infiltration in staging of lymphoma: a systematic review and meta-analysis.

    abstract:BACKGROUND AND PURPOSE:Evaluation of bone marrow infiltration is an essential step in the staging of lymphoma. The accuracy of (18)F-fluorodeoxyglucose-positron emission tomography ((18)F-FDG PET), combined (18)F-fluorodeoxyglucose-positron emission tomography/computed tomography ((18)F-FDG-PET/CT) and magnetic resonan...

    journal_title:European journal of radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.ejrad.2010.11.020

    authors: Wu LM,Chen FY,Jiang XX,Gu HY,Yin Y,Xu JR

    更新日期:2012-02-01 00:00:00

  • Image quality performance of liquid crystal display systems: influence of display resolution, magnification and window settings on contrast-detail detection.

    abstract::The aim of this study was to investigate the combined effects of liquid crystal display (LCD) resolution, image magnification and window/level adjustment on the low-contrast performance in soft-copy image interpretation in digital radiography and digital mammography. In addition, the effect of a new LCD noise reductio...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2005.12.016

    authors: Bacher K,Smeets P,De Hauwere A,Voet T,Duyck P,Verstraete K,Thierens H

    更新日期:2006-06-01 00:00:00

  • Dynamic sequential computed tomography in abdominal tumours. Some aspects for differential diagnosis.

    abstract::Dynamic CT in combination with intravenous bolus injection of contrast material provides a study of the pharmacokinetics in great vessels as well as in tissues. If the enhancement in the region of interest is plotted against time, the time-enhancement diagrams obtained reflect the contrast material passage mathematica...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Metzger HO,Hübener KH

    更新日期:1985-02-01 00:00:00

  • S-MRI score: A simple method for assessing bone marrow involvement in Gaucher disease.

    abstract::Semi quantitative MRI is a very useful procedure for evaluating the bone marrow burden (BMB) in Gaucher disease (GD). Score systems have been applied to obtain a parameter for evaluating the severity of bone disease. Our purpose was to test a simple, reproducible and accurate score to evaluate bone marrow involvement ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.11.024

    authors: Roca M,Mota J,Alfonso P,Pocoví M,Giraldo P

    更新日期:2007-04-01 00:00:00

  • Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver: comparison of different concentrations of contrast material with multi-detector row helical CT--a prospective randomized study.

    abstract:PURPOSE:To evaluate two different iodine concentrations of contrast material for detecting hypervascular hepatocellular carcinomas (HCCs) in cirrhotic liver by multi-detector row helical CT (MDCT) when a fixed contrast material volume and injection rate is used. MATERIALS AND METHODS:Institutional Review Board approva...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2010.10.006

    authors: Sofue K,Tsurusaki M,Kawasaki R,Fujii M,Sugimura K

    更新日期:2011-12-01 00:00:00

  • Multi-slice CT angiography of small cerebral aneurysms: is the direction of aneurysm important in diagnosis?

    abstract:PURPOSE:Multi-slice CT (MSCT) has great potential in evaluation of vascular structures. Our purpose was to investigate if there is any difference in detection of superiorly, inferiorly and horizontally directed small cerebral aneurysms (<5 mm) on MSCTA compared to digital subtraction angiography (DSA) or surgery. MATE...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.05.002

    authors: Teksam M,McKinney A,Cakir B,Truwit CL

    更新日期:2005-03-01 00:00:00

  • Measurement of single-kidney glomerular filtration function from magnetic resonance perfusion renography.

    abstract::Glomerular filtration rate (GFR) describes the flow rate of filtered fluid through the kidney, and is considered to be the reference standard in the evaluation of renal function. There are many ways to test the GFR clinically, such as serum creatinine concentration, blood urea nitrogen and SPECT renography, however, t...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2015.05.009

    authors: Zeng M,Cheng Y,Zhao B

    更新日期:2015-08-01 00:00:00

  • Time-resolved quantitative evaluation of diaphragmatic motion during forced breathing in a health screening cohort in a standing position: Dynamic chest phrenicography.

    abstract:OBJECTIVE:To assess diaphragmatic motion during forced breathing in a health screening center cohort by time-resolved quantitative analysis using dynamic chest radiography and demonstrate the characteristics and associations with demographics and pulmonary function of participants. MATERIALS AND METHODS:This prospecti...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.01.034

    authors: Hida T,Yamada Y,Ueyama M,Araki T,Nishino M,Kurosaki A,Jinzaki M,Honda H,Hatabu H,Kudoh S

    更新日期:2019-04-01 00:00:00

  • Assessment of colorectal liver metastases using MRI and CT: impact of observer experience on diagnostic performance and inter-observer reproducibility with histopathological correlation.

    abstract:INTRODUCTION:To compare the diagnostic performance and inter-observer reproducibility of CT and MRI in detecting colorectal liver metastases (CRLM) of observers with different levels of experience. MATERIALS AND METHODS:Data from 51 CT and 54 MRI examinations of 105 patients with CRLM were analysed. Intraoperative and...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.07.005

    authors: Albrecht MH,Wichmann JL,Müller C,Schreckenbach T,Sakthibalan S,Hammerstingl R,Bechstein WO,Zangos S,Ackermann H,Vogl TJ

    更新日期:2014-10-01 00:00:00

  • Mammography with and without radiolucent positioning sheets: Comparison of projected breast area, pain experience, radiation dose and technical image quality.

    abstract:PURPOSE:To compare projected breast area, image quality, pain experience and radiation dose between mammography performed with and without radiolucent positioning sheets. METHODS:184 women screened in the Dutch breast screening programme (May-June 2012) provided written informed consent to have one additional image ta...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.07.005

    authors: Timmers J,Voorde MT,Engen RE,Landsveld-Verhoeven Cv,Pijnappel R,Greve KD,Heeten GJ,Broeders MJ

    更新日期:2015-10-01 00:00:00

  • Spinal trauma: therapy--options and outcomes.

    abstract::The management of patients with spinal trauma is based on the following goals: (1) the preservation of life; (2) preserving and maximising the neurological function; and (3) providing a stable, painless vertebral column. There have been advances in both non operative as well operative modalities of treatment of patien...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(02)00045-1

    authors: Trivedi JM

    更新日期:2002-05-01 00:00:00

  • Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers.

    abstract:OBJECTIVE:The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. MATERIALS AND METHODS:CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers dete...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.08.024

    authors: Sadaf A,Crystal P,Scaranelo A,Helbich T

    更新日期:2011-03-01 00:00:00