Reliability of MR Quantification of Rotator Cuff Muscle Fatty Degeneration Using a 2-point Dixon Technique in Comparison with the Goutallier Classification: Validation Study by Multiple Readers.

Abstract:

RATIONALE AND OBJECTIVES:Presurgical assessment of fatty degeneration is important in the management of patients with rotator cuff tears. The Goutallier classification is widely accepted as a qualitative scoring system, although it is highly observer-dependent and has poor reproducibility. The objective of this study was to quantify fatty degeneration of the supraspinatus muscle using a 2-point Dixon technique in patients with rotator cuff tears by multiple readers, and to evaluate the reproducibility compared to Goutallier classification. MATERIALS AND METHODS:Two hundred patients with rotator cuff tears who underwent magnetic resonance imaging (MRI), including 2-point Dixon sequence at 3.0-T, were selected retrospectively. Qualitative and quantitative analyses of fatty degeneration were performed by two radiologists and three orthopedic surgeons independently. The fat quantification was performed by measuring signal intensity values of in phase (S(In)) and fat image (S(Fat)), and calculating fat fraction as S(Fat)/S(In). The reproducibility of MR quantification was analyzed by the intra- and interclass correlation coefficients and Bland-Altman plots. RESULTS:The interobserver agreement of the Goutallier classification among five readers was moderate (k = 0.51), whereas the interclass correlation coefficient regarding fat fraction value quantified in 2-point Dixon sequence was excellent (0.893). The mean differences in fat fraction values from the individual segmentation results were from -0.072 to 0.081. Proposed fat fraction grading and Goutallier grading showed similar frequency and distribution in severity of rotator cuff tears. CONCLUSIONS:Fat quantification in the rotator cuff muscles using a 2-point Dixon technique at 3.0-T MRI is highly reproducible and clinically feasible in comparison to the qualitative evaluation using Goutallier classification.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Horiuchi S,Nozaki T,Tasaki A,Yamakawa A,Kaneko Y,Hara T,Yoshioka H

doi

10.1016/j.acra.2017.03.026

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

1343-1351

issue

11

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(17)30209-X

journal_volume

24

pub_type

杂志文章
  • A randomized trial of prophylactic acetylcysteine and theophylline compared with placebo for the prevention of renal tubular vacuolization in rats after iohexol administration.

    abstract:RATIONALE AND OBJECTIVES:Renal tubular vacuolization (RTV), which has been shown to occur after the use of iodinated contrast material, may be one of the earliest signs of contrast medium-induced renal injury. In this study, the authors tested a method for preventing RTV with the administration of acetylcysteine, theop...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80061-2

    authors: Emch TM,Haller NA

    更新日期:2003-05-01 00:00:00

  • Efficacy of Diffusion-Weighted Imaging in Neoadjuvant Chemotherapy for Osteosarcoma: A Systematic Review and Meta-Analysis.

    abstract:RATIONALE AND OBJECTIVES:Diffusion-weighted imaging (DWI) is a noninvasive imaging technique that reflects the diffusion movement of water molecules through apparent diffusion coefficient (ADC) values. The role of DWI in predicting the histological response to neoadjuvant chemotherapy in osteosarcoma is being increasin...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2020.11.013

    authors: Yuan W,Yu Q,Wang Z,Huang J,Wang J,Long L

    更新日期:2020-12-29 00:00:00

  • Experimental correlation between T2* and ultimate compressive strength in lumbar porcine vertebrae.

    abstract:RATIONALE AND OBJECTIVES:The authors used magnetic resonance (MR) imaging to investigate the correlation between T2* measurements of trabecular bone and the ultimate compressive strength of lumbar porcine vertebrae. METHODS:Five pigs that weighted 25-32 kg were sacrificed and imaged with a 1.5-T MR system. T2* of the ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(97)80050-5

    authors: Brismar TB,Hindmarsh T,Ringertz H

    更新日期:1997-06-01 00:00:00

  • Optimal timing and diagnostic adequacy of hepatocyte phase imaging with gadoxetate-enhanced liver MRI.

    abstract:RATIONALE AND OBJECTIVES:To evaluate clinical and imaging features associated with adequacy of the hepatocyte phase (HP) in gadoxetate disodium-enhanced liver magnetic resonance imaging (MRI) in patients without chronic liver disease (CLD). MATERIALS AND METHODS:This was a retrospective institutional review board-appr...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.02.005

    authors: Bashir MR,Breault SR,Braun R,Do RK,Nelson RC,Reeder SB

    更新日期:2014-06-01 00:00:00

  • Multi-reader ROC studies with split-plot designs: a comparison of statistical methods.

    abstract:RATIONALE AND OBJECTIVES:Multireader imaging trials often use a factorial design, in which study patients undergo testing with all imaging modalities and readers interpret the results of all tests for all patients. A drawback of this design is the large number of interpretations required of each reader. Split-plot desi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.09.012

    authors: Obuchowski NA,Gallas BD,Hillis SL

    更新日期:2012-12-01 00:00:00

  • Continuous arterial spin-labeling perfusion magnetic resonance imaging of the human testis.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine if continuous arterial spin-labeling perfusion magnetic resonance imaging could be used to detect testicular perfusion in human subjects. MATERIALS AND METHODS:Continuous arterial spin-labeling magnetic resonance perfusion imaging was performed in sev...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)00576-2

    authors: Pretorius ES,Roberts DA

    更新日期:2004-01-01 00:00:00

  • Clinical Applications of DSC-MRI Parameters Assess Angiogenesis and Differentiate Malignant From Benign Soft Tissue Tumors in Limbs.

    abstract:OBJECTIVE:To investigate the correlation between dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) parameters and angiogenesis and to explore prospectively the feasibility of using DSC-MRI to differentiate malignant from benign soft tissue tumors (STTs) in limbs. METHODS:This prospective study inclu...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.04.023

    authors: Bian Y,Jin P,Wang Y,Wei X,Qiang Y,Niu G,Jin G,Yang J

    更新日期:2020-03-01 00:00:00

  • Longitudinal changes in airway remodeling and air trapping in severe asthma.

    abstract:RATIONALE AND OBJECTIVES:Previous cross-sectional studies have demonstrated that airway wall thickness and air trapping are greater in subjects with severe asthma than in those with mild-to-moderate asthma. However, a better understanding of how airway remodeling and lung density change over time is needed. This study ...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.acra.2014.05.001

    authors: Witt CA,Sheshadri A,Carlstrom L,Tarsi J,Kozlowski J,Wilson B,Gierada DS,Hoffman E,Fain SB,Cook-Granroth J,Sajol G,Sierra O,Giri T,O'Neill M,Zheng J,Schechtman KB,Bacharier LB,Jarjour N,Busse W,Castro M,NHLBI Sever

    更新日期:2014-08-01 00:00:00

  • Marking of small pulmonary nodules before thoracoscopic resection: injection of lipiodol under CT-fluoroscopic guidance.

    abstract:RATIONALE AND OBJECTIVES:The aim of the present study was to examine the usefulness and record the complications of preoperative lipiodol marking using computed tomographic (CT) fluoroscopy for the intraoperative localization of 107 pulmonary nodules. METHODS:Lipiodol marking was performed under CT fluoroscopic guidan...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.07.012

    authors: Kawanaka K,Nomori H,Mori T,Ikeda K,Ikeda O,Tomiguchi S,Yamashita Y

    更新日期:2009-01-01 00:00:00

  • Effects of oral 5-fluorouracil drugs on hepatic fat content in patients with colon cancer.

    abstract:RATIONALE AND OBJECTIVES:The association between hepatic steatosis and oral 5-fluorouracil (5-FU) agents is clinically recognized but has not been systematically studied. The aim of this study was to determine the effects of 5-FU on hepatic fat content in patients undergoing oral 5-FU therapy and to compare the effects...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.02.010

    authors: Miyake K,Hayakawa K,Nishino M,Morimoto T,Mukaihara S

    更新日期:2005-06-01 00:00:00

  • Quality of communication: different patterns of reporting the location of the tip of a nasogastric tube.

    abstract:PURPOSE:This investigation is part of a prospective National Institutes of Health-funded study evaluating three different methods for estimating the optimal length for placement of a new nasogastric (NG) tube. Abdomen radiographs were required to determine the location of the tube tip. Our objective was to analyze diff...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.02.007

    authors: Cohen MD,Ellett M

    更新日期:2012-06-01 00:00:00

  • Postoperative CT of the Mandible Following Trauma: Review of Normal Appearances and Common Complications.

    abstract:RATIONALE AND OBJECTIVES:Surgeons aim to restore occlusion and jaw function to baseline status for patients with mandibular fractures using either closed treatment or reduction and fixation. MATERIALS AND METHODS:Occlusion is defined as the relationship between the maxillary and mandibular teeth as they approach each ...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2018.06.009

    authors: Reiter MJ,Schwope RB,Theler JM

    更新日期:2019-05-01 00:00:00

  • Preoperative MRI improves prediction of extensive occult axillary lymph node metastases in breast cancer patients with a positive sentinel lymph node biopsy.

    abstract:RATIONALE AND OBJECTIVES:To test the ability of quantitative measures from preoperative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to predict, independently and/or with the Katz pathologic nomogram, which breast cancer patients with a positive sentinel lymph node biopsy will have four or more positi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2013.10.001

    authors: Loiselle C,Eby PR,Kim JN,Calhoun KE,Allison KH,Gadi VK,Peacock S,Storer BE,Mankoff DA,Partridge SC,Lehman CD

    更新日期:2014-01-01 00:00:00

  • Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    abstract:RATIONALE AND OBJECTIVES:Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influence...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.03.016

    authors: Miglioretti DL,Ichikawa L,Smith RA,Buist DSM,Carney PA,Geller B,Monsees B,Onega T,Rosenberg R,Sickles EA,Yankaskas BC,Kerlikowske K

    更新日期:2017-10-01 00:00:00

  • Are NBME examination scores useful in selecting radiology residency candidates?

    abstract:RATIONALE AND OBJECTIVES:The quality of the graduates of radiology residency programs is powerfully affected by the quality of the candidates admitted to them, making the evaluation and ranking of residency applicants one of the most important tasks of radiology education. In the applicant evaluation process, evaluator...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(00)80575-9

    authors: Gunderman RB,Jackson VP

    更新日期:2000-08-01 00:00:00

  • Radiology faculty evaluation: bi-institutional implementation of an experimental appraisal instrument.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluated the reliability and validity of an experimental radiology faculty appraisal instrument. MATERIALS AND METHODS:Residents from the University of Wisconsin (UW) and Indiana University (IU) were asked to use a previously developed behaviorally based, 53-item experimental facu...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(98)80266-3

    authors: Collins J,Albanese MA,Scanlan KA,Propeck PA,Jackson VP

    更新日期:1998-11-01 00:00:00

  • Combining Washout and Noncontrast Data From Adrenal Protocol CT: Improving Diagnostic Performance.

    abstract:RATIONALE AND OBJECTIVES:To determine if combination of washout and noncontrast data from delayed adrenal computed tomography (CT) improves diagnostic performance, and demonstration of an optimizing analytical framework. MATERIALS AND METHODS:This retrospective study consisted of 97 adrenal lesions, in 96 patients, wi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.005

    authors: Ng CS,Altinmakas E,Wei W,Ghosh P,Li X,Grubbs EG,Perrier NA,Prieto VG,Lee JE,Hobbs BP

    更新日期:2018-07-01 00:00:00

  • Computer-assisted mammography feedback program (CAMFP) an electronic tool for continuing medical education.

    abstract:RATIONALE AND OBJECTIVES:Our goal was to develop and evaluate software to support a computer assisted mammography feedback program (CAMFP) to be used for continuing medical education (CME). MATERIALS AND METHODS:Thirty-five radiologists from our region signed consent to participate in an institutional review board-app...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.05.018

    authors: Urban N,Longton GM,Crowe AD,Drucker MJ,Lehman CD,Peacock S,Lowe KA,Zeliadt SB,Gaul MA

    更新日期:2007-09-01 00:00:00

  • Augmented Radiologist Workflow Improves Report Value and Saves Time: A Potential Model for Implementation of Artificial Intelligence.

    abstract:RATIONALE AND OBJECTIVES:Our primary aim was to improve radiology reports by increasing concordance of target lesion measurements with oncology records using radiology preprocessors (RP). Faster notification of incidental actionable findings to referring clinicians and clinical radiologist exam interpretation time savi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.09.014

    authors: Do HM,Spear LG,Nikpanah M,Mirmomen SM,Machado LB,Toscano AP,Turkbey B,Bagheri MH,Gulley JL,Folio LR

    更新日期:2020-01-01 00:00:00

  • Imaging Hepatocellular Carcinoma with Dynamic CT Before and After Transarterial Chemoembolization: Optimal Scan Timing of Arterial Phase.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to determine the optimal arterial phase delay for computed tomography imaging of hepatocellular carcinoma (HCC) before and after transarterial chemoembolization (TACE) using a low iodine dose protocol. MATERIALS AND METHODS:A total of 39 patients with known HCC were i...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2015.08.021

    authors: Saake M,Lell MM,Eller A,Wuest W,Heinz M,Uder M,Schmid A

    更新日期:2015-12-01 00:00:00

  • Experimentally induced pulmonary arterial occlusion with detachable balloon in pigs: thin-section CT findings.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluated changes of lung attenuation in pigs, with special attention to the mosaic pattern of low attenuation, at thin-section computed tomography (CT) after obstruction of the proximal pulmonary artery with a detachable balloon. MATERIALS AND METHODS:In seven pigs, nine sites of ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(98)80241-9

    authors: Kim TK,Im JG,Kim SH,Won HJ,Seo JB,Yeon KM,Han MC

    更新日期:1998-12-01 00:00:00

  • A comparison of internally water-perfused and cryogenically cooled monopolar and bipolar radiofrequency applicators in ex vivo liver samples.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the ex vivo ablation zones created in hepatic tissue using monopolar and bipolar gas- and water-cooled radiofrequency (RF) applicators. MATERIALS AND METHODS:RF ablations were performed on ex vivo bovine liver tissue using closed circuit water-cooled and closed circuit cryogenicall...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.02.004

    authors: Rempp H,Mezger D,Voigtlaender M,Scharpf M,Hoffmann R,Pereira PL,Enderle MD,Claussen CD,Clasen S

    更新日期:2014-05-01 00:00:00

  • Effect of gravity on drug distribution after port-catheter implantation for hepatic arterial infusion chemotherapy: evaluation of the relationship between the injection posture and intrahepatic perfusion on fused images acquired with a combined SPECT/CT s

    abstract:RATIONALE AND OBJECTIVES:We evaluated the effect of gravity on intrahepatic perfusion (IHP) in patients with a port-catheter system (PCS) implanted for hepatic arterial infusion chemotherapy (HAIC). Using fused single photon-emission computed tomographic (SPECT)/computed tomographic (CT) images, we compared IHP after t...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.acra.2008.12.004

    authors: Tamura Y,Ikeda O,Nakasone Y,Shiraishi S,Tomiguchi S,Yamashita Y,Takamori H,Baba H

    更新日期:2009-06-01 00:00:00

  • Low-dose unenhanced CT for IV contrast bolus timing: is it reliable to assess hepatic steatosis?

    abstract:RATIONALE AND OBJECTIVES:To determine whether an unenhanced low-dose image acquired during automated contrast bolus timing can be used to assess hepatic steatosis. MATERIALS AND METHODS:Fifty subjects (29 male, 21 female; 26-92 years; mean body mass index (BMI; 26.9) with abdominal multiphasic computed tomography were...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.02.013

    authors: Husarik DB,Boll DT,Nelson RC,Merkle EM

    更新日期:2011-07-01 00:00:00

  • Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS:An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.02.021

    authors: Schindera ST,Nelson RC,Yoshizumi T,Toncheva G,Nguyen G,DeLong DM,Szucs-Farkas Z

    更新日期:2009-08-01 00:00:00

  • A model for a PC-based, universal-format, multimedia digitization system: moving beyond the scanner.

    abstract:RATIONALE AND OBJECTIVES:Digitizing images for use in case presentations based on hardcopy films, slides, photographs, negatives, books, and videos can present a challenging task. Scanners and digital cameras have become standard tools of the trade. Unfortunately, use of these devices to digitize multiple images in man...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)00010-2

    authors: McEachen JC,Cusack TJ,McEachen JC

    更新日期:2003-08-01 00:00:00

  • Helical multidetector row quantitative computed tomography (QCT) precision.

    abstract:RATIONALE AND OBJECTIVES:The impact of varying image acquisition parameters on the precision of measurements using quantitative computed tomography is currently based on studies performed before the advent of helical image acquisition and multidetector-row scanners. The aim of this study was to evaluate helical multide...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.08.007

    authors: Bligh M,Bidaut L,White RA,Murphy WA Jr,Stevens DM,Cody DD

    更新日期:2009-02-01 00:00:00

  • New assistive devices for MR-guided microwave thermocoagulation of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to develop and test new assistive devices to aid in the performance of safe, easy, and accurate microwave thermocoagulation therapy guided by magnetic resonance (MR) imaging. MATERIALS AND METHODS:An open-configuration MR imager with an optical tracking system for...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80043-0

    authors: Morikawa S,Inubushi T,Kurumi Y,Naka S,Sato K,Tani T,Haque HA,Tokuda J,Hata N

    更新日期:2003-02-01 00:00:00

  • Performance of dual-energy CT with tin filter technology for the discrimination of renal cysts and enhancing masses.

    abstract:RATIONALE AND OBJECTIVES:To assess the performance of dual-energy computed tomography (DECT) equipped with the new tin filter technology to classify phantom renal lesions as cysts or enhancing masses. MATERIALS AND METHODS:Forty spherical lesion proxies ranging in diameter from 6 to 27 mm were filled with either disti...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.11.007

    authors: Leschka S,Stolzmann P,Baumüller S,Scheffel H,Desbiolles L,Schmid B,Marincek B,Alkadhi H

    更新日期:2010-04-01 00:00:00

  • Local toxicity of hepatic arterial infusion of hexokinase II inhibitor, 3-bromopyruvate: In vivo investigation in normal rabbit model.

    abstract:RATIONALE AND OBJECTIVES:3-Bromopyruvate (3-BrPA), an hexokinase II inhibitor, is known to have high necrotic rate in hyperglycolytic liver tumor models without apparent damage to the normal liver parenchyma. The toxicity of intra-arterial delivery of 3-BrPA in various concentrations has not been specifically investiga...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.09.059

    authors: Chang JM,Chung JW,Jae HJ,Eh H,Son KR,Lee KC,Park JH

    更新日期:2007-01-01 00:00:00