Abstract:
BACKGROUND:Only a few studies on the cephalic vein cutdown technique for pacemaker lead implantation in children weighing ≤10 kg have been reported even though the procedure is widely accepted in adults. OBJECTIVE:The purpose of this study was to prove that cephalic vein cutdown for pacemaker lead implantation is a reliable technique with a low incidence of complications in children weighing ≤10 kg. METHODS:The study included 44 children weighing ≤10 kg with an endocardial pacemaker. Cephalic, subclavian, and axillary vein diameters were measured by ultrasound before implantation. The measured diameters were used to select either an endocardial or epicardial surgical technique. Regular 6-month follow-up visits included pacemaker interrogation and clinical and ultrasound examinations. RESULTS:Two dual-chamber and 42 single-chamber pacemakers were implanted. Mean weight at implantation was 6.24 kg (range 2.25-10.40 kg), and mean age was 11.4 months (range 1 day-47 months). In 40 children (90.1%), the ventricular leads were implanted using the cephalic vein cutdown technique, and implantation was accomplished via the prepared right external jugular vein in 4 of the children (9.9%). The atrial leads were implanted using axillary vein puncture and external jugular vein preparations. Mean follow-up was 8.9 years (range 0-20.9 years). Only 1 pacemaker-related complication was detected (a lead fracture near the connector that was successfully resolved using a lead repair kit). CONCLUSION:The cephalic vein cutdown technique is feasible and reliable in children weighing ≤10 kg, which justifies the application of additional surgical effort in the treatment of these small patients.
journal_name
Heart Rhythmjournal_title
Heart rhythmauthors
Kircanski B,Vasic D,Savic D,Stojanov Pdoi
10.1016/j.hrthm.2015.04.025subject
Has Abstractpub_date
2015-08-01 00:00:00pages
1820-6issue
8eissn
1547-5271issn
1556-3871pii
S1547-5271(15)00492-0journal_volume
12pub_type
杂志文章相关文献
HEART RHYTHM文献大全abstract:BACKGROUND:Pulmonary vein (PV) isolation has become the mainstay acute procedural end point for paroxysmal atrial fibrillation (AF) ablation. OBJECTIVE:To examine the incidence of conduction recovery in the PVs in patients without clinical recurrence of AF after paroxysmal AF ablation. METHODS:From August 2008 to Mar...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2014.03.015
更新日期:2014-06-01 00:00:00
abstract:BACKGROUND:Catheter ablation for polymorphic ventricular tachycardia and ventricular fibrillation (PMVT/VF) may target triggering premature ventricular contractions (PVCs). Targeting ventricular scar has also been suggested, but data are limited. OBJECTIVE:The purpose of this study was to characterize the electrophysi...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.01.032
更新日期:2019-07-01 00:00:00
abstract:BACKGROUND:The vein of Marshall (VOM) is a left atrial (LA) vein that contains autonomic innervation and triggers of AF. Its location coincides with areas usually ablated during pulmonary vein (PV) antral isolation (PVAI). OBJECTIVE:This study sought to delineate the safety and ablative effects of ethanol infusion in ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2009.07.036
更新日期:2009-11-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to determine if AV delay optimization with continuous-wave Doppler aortic velocity-time integral (VTI) is clinically superior to an empiric program in patients treated with cardiac resynchronization therapy (CRT) for severe heart failure. BACKGROUND:The impact of AV delay progr...
journal_title:Heart rhythm
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/j.hrthm.2004.07.006
更新日期:2004-11-01 00:00:00
abstract:BACKGROUND:Right-sided accessory pathway (RAP) ablation is sometimes challenging. OBJECTIVE:Our study aimed to demonstrate an alternative ablation approach to RAPs under the tricuspid valve, especially when the conventional ablation attempts at the atrial side failed. METHODS:Twelve patients with RAPs were enrolled, ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.07.022
更新日期:2019-01-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to identify risk markers in patients with Brugada syndrome. BACKGROUND:Patients with Brugada syndrome who experience syncope or aborted sudden death are at high risk for recurrent lethal arrhythmias. The prognosis and therapeutic approaches in asymptomatic individuals with a Br...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2004.11.022
更新日期:2005-03-01 00:00:00
abstract:BACKGROUND:In recent years, upgrade and revision procedures of cardiac implantable electronic devices (CIEDs) have become increasingly frequent. Patency of the access veins is critical for procedural success. OBJECTIVE:The purpose of this study was to determine the incidence of venous obstruction at the time of system...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.08.012
更新日期:2020-02-01 00:00:00
abstract:BACKGROUND:Implantable cardioverter-defibrillators monitor intracardiac electrograms (EGMs) to discriminate between ventricular and supraventricular tachycardias. The incidence of inappropriate shocks remains high because of misclassification of the tachycardia in an otherwise hemodynamically stable individual. Couplin...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2014.06.034
更新日期:2014-11-01 00:00:00
abstract::I am deeply grateful and honored to receive the 2006 Distinguished Scientist Award from the Heart Rhythm Society. Many outstanding individuals have received this award since it was established in 1982, and it is humbling to realize that my small feet are walking in the footsteps of these giants. I would be remiss if I...
journal_title:Heart rhythm
pub_type: 杂志文章,评审
doi:10.1016/j.hrthm.2007.02.004
更新日期:2007-05-01 00:00:00
abstract:BACKGROUND:Ventricular late potentials (VLPs) have been known to be a predictor of lethal ventricular arrhythmias (L-VAs); however, detection of other arrhythmogenic signals within the QRS complex remains obscure. OBJECTIVE:The aim of this study was to evaluate whether abnormal intra-QRS high-frequency powers (IQHFP) ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2011.06.027
更新日期:2011-10-01 00:00:00
abstract:BACKGROUND:Magnetic resonance imaging (MRI) has been performed safely in patients without MRI-conditional cardiac implantable electronic devices (CIEDs), but experience specifically with cardiac magnetic resonance imaging (CMR) is limited in this patient population. OBJECTIVE:Evaluate the safety of CMR in non-MRI-cond...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2017.10.003
更新日期:2018-02-01 00:00:00
abstract:BACKGROUND:Pericardial effusion, a sign of cardiac perforation, may complicate permanent pacemaker placement. Risk factors for development of post-permanent pacemaker effusion have not been evaluated. OBJECTIVES:The purpose of this study was to determine the predictors of symptomatic pericardial effusion after permane...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2005.06.011
更新日期:2005-09-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to evaluate the safety and efficacy of cryoablation in a closed chest canine epicardial ablation model. BACKGROUND:Limitations of radiofrequency energy in the epicardial space warrants investigation of alternative energy sources. METHODS:A linear-tip catheter with a 3-cm freez...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2004.09.022
更新日期:2005-01-01 00:00:00
abstract:BACKGROUND:We previously showed that the cardioversion threshold (CVT) for ventricular tachycardia (VT) is phase dependent when a single monophasic shock (1MP) is used. OBJECTIVE:The purpose of this study was to extend these findings to a biphasic shock (1BP) and to compare the efficacy of phase-independent multiple m...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2009.03.015
更新日期:2009-07-01 00:00:00
abstract:BACKGROUND:The occurrence of congestive heart failure (CHF) hospitalization among patients with atrial fibrillation (AF) is a poor prognostic marker. OBJECTIVE:The purpose of this study was to assess whether insulin-like growth factor-binding protein 7 (IGFBP-7), a marker of myocardial damage, identifies AF patients a...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.11.028
更新日期:2020-12-03 00:00:00
abstract:BACKGROUND:Approximately 30% of all accessory pathways (APs) are located in the septal area, and understanding the electrocardiographic and electrophysiologic of these APs is crucial for safe and effective ablation of these pathways. OBJECTIVE:In this study, the electrocardiographic and electrophysiologic characterist...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2007.07.009
更新日期:2007-11-01 00:00:00
abstract:BACKGROUND:There is a close anatomical relationship between the right coronary cusp (RCC) and noncoronary aortic cusp (NCC) and sites recording His bundle (HB) activation in the right ventricle (RV). OBJECTIVE:The purpose of this study was to examine the electrocardiographic and electrophysiological characteristics of...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2007.08.032
更新日期:2008-01-01 00:00:00
abstract:BACKGROUND:Conventional cardiac device infections are increasing in incidence, causing significant morbidity and mortality. Leadless pacemaker (LP) therapy may provide new opportunities for the management of pacemaker (PM) infections as it does not require implantation of transvenous leads and a pectoral pocket. OBJEC...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.07.006
更新日期:2019-01-01 00:00:00
abstract:BACKGROUND:Epicardial pacing increases risk of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) when pacing in proximity to scar. Endocardial pacing may be less arrhythmogenic as it preserves the physiological sequences of activation and repolarization. OBJECTIVE:The purpose of this study wa...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.03.021
更新日期:2020-08-01 00:00:00
abstract:BACKGROUND:The spatial resolution of pacemapping using 12-lead electrocardiography (ECG) or PaSo software is unknown. OBJECTIVE:The purpose of this study was to determine the spatial resolution of traditional ECG pacemapping and pacemapping using the PaSo coefficients. METHODS:Seventeen patients undergoing ablation o...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.08.029
更新日期:2020-02-01 00:00:00
abstract:BACKGROUND:Physicians will increasingly encounter patients who require rhythm management devices but have venous obstructions that prevent conventional access. Alternate access options, such as thoracotomy or transiliac approaches, exist but are associated with greater cost and morbidity. OBJECTIVE:The purpose of this...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2011.01.024
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:The cardiac sodium channel (SCN5A) mutation R222Q neutralizes a positive charge in the domain I voltage sensor. Mutation carriers display very frequent ectopy and dilated cardiomyopathy. OBJECTIVES:To describe the effect of SCN5A R222Q on murine myocyte and Purkinje fiber electrophysiology, and identify und...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.05.017
更新日期:2019-11-01 00:00:00
abstract:BACKGROUND:Data on inappropriate implantable cardioverter-defibrillator (ICD) therapy and effects of programming by heart rate are lacking. OBJECTIVE:We aimed to characterize inappropriate ICD therapy and assess the effects of novel programming by heart rate. METHODS:Incidence and causes of inappropriate therapy by h...
journal_title:Heart rhythm
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1016/j.hrthm.2015.05.021
更新日期:2015-09-01 00:00:00
abstract:BACKGROUND:Obesity and weight gain are established risk factors for atrial fibrillation (AF). OBJECTIVE:The purpose of this study was to investigate whether bodyweight variability is also a risk factor for AF development. METHODS:A nationwide population-based cohort of 8,091,401 adults from the Korean National Health...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.09.029
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND:Areas of conduction delay (CD) or conduction block (CB) are associated with higher recurrence rates after ablation therapy for atrial fibrillation (AF). OBJECTIVE:Thus far, there are no reports on the quantification of the extensiveness of CD and CB at the pulmonary vein area (PVA) and their clinical releva...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.10.027
更新日期:2019-04-01 00:00:00
abstract:BACKGROUND:Prolongation of the PR interval has been associated with an increased risk of incident atrial fibrillation (AF). OBJECTIVE:To determine if there was a nonlinear relation between PR interval duration and the risk of AF. METHODS:We included 288,181 individuals, corresponding to one third of the population in...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2013.04.012
更新日期:2013-09-01 00:00:00
abstract:BACKGROUND:Hyperthyroidism is a known reversible cause of atrial fibrillation (AF). However, some patients remain in AF despite restoration of euthyroid status. OBJECTIVE:The purpose of this study was to compare the electrophysiologic characteristics and long-term ablation outcome in AF patients with and without histo...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2015.06.004
更新日期:2015-09-01 00:00:00
abstract:BACKGROUND:Verification of bidirectional block is important for mitral isthmus (MI) ablation. However, recurrent perimitral reentry exists despite apparently MI block. OBJECTIVE:The purpose of this study was to identify and investigate the characteristics of the ridge breakthrough despite apparent bidirectional MI blo...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2016.06.018
更新日期:2016-09-01 00:00:00
abstract:BACKGROUND:In patients with ventricular tachycardia or ventricular fibrillation (VT/VF) electrical storm (ES) undergoing catheter ablation (CA), hypotension due to refractory VT/VF, use of anesthesia, and cardiac stunning due to repeated implantable cardioverter-defibrillator shocks might precipitate acute hemodynamic ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2017.09.005
更新日期:2018-01-01 00:00:00
abstract:BACKGROUND:Tissue refractoriness to conduction is a crucial electrophysiological factor in determining susceptibility to fibrillation. The relationship between atrial refractoriness and future onset of atrial fibrillation (AF) has not been well studied. OBJECTIVES:We investigated whether atrial effective refractory pe...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2016.03.037
更新日期:2016-08-01 00:00:00