Influence of Micro Threads Alteration on Osseointegration and Primary Stability of Implants: An FEA and In Vivo Analysis in Rabbits.

Abstract:

PURPOSE:To describe the early bone tissue response to implants with and without micro threads designed to the full length of an oxidized titanium implant. MATERIALS AND METHODS:A pair of two-dimensional finite element models was designed using a computer aided three-dimensional interactive application files of an implant model with micro threads in between macro threads and one without micro threads. Oxidized titanium implants with (test implants n=20) and without (control implants n=20) micro thread were prepared. A total of 12 rabbits were used and each received four implants. Insertion torque while implant placement and removal torque analysis after 4 weeks was performed in nine rabbits, and histomorphometric analysis in three rabbits, respectively. RESULTS:Finite element analysis showed less stress accumulation in test implant models with 31Mpa when compared with 62.2 Mpa in control implant model. Insertion and removal torque analysis did not show any statistical significance between the two implant designs. At 4 weeks, there was a significant difference between the two groups in the percentage of new bone volume and bone-to-implant contact in the femur (p< .05); however, not in the tibia. CONCLUSIONS:The effect of micro threads was prominent in the femur suggesting that micro threads promote bone formation. The stress distribution supported by the micro threads was especially effective in the cancellous bone.

authors

Chowdhary R,Halldin A,Jimbo R,Wennerberg A

doi

10.1111/cid.12143

subject

Has Abstract

pub_date

2015-06-01 00:00:00

pages

562-9

issue

3

eissn

1523-0899

issn

1708-8208

journal_volume

17

pub_type

杂志文章
  • One-year prospective three-center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant.

    abstract:BACKGROUND:Oral implant treatment ad modum Brånemark has been used for decades in the rehabilitation of edentate and partially dentate patients. Posterior jaw regions frequently exhibit bone of poor texture, and it is often difficult to obtain primary stability. Thus, it may prove beneficial to deviate from the origina...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1708-8208.2003.tb00186.x

    authors: Friberg B,Jisander S,Widmark G,Lundgren A,Ivanoff CJ,Sennerby L,Thorén C

    更新日期:2003-01-01 00:00:00

  • Transcrestal Sinus Lift Using Platelet Concentrates in Association to Short Implant Placement: A Retrospective Study of Augmented Bone Height Remodeling.

    abstract:BACKGROUND:No evidence has been reported yet about dimensional changes in maxillary sinuses grafted with autologous platelet concentrate. PURPOSE:This study aimed to analyze the augmented height alterations around short implants (length ≤ 8.5 mm) placed after transcrestal sinus lift surgery in association with plasma ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12383

    authors: Anitua E,Flores J,Alkhraisat MH

    更新日期:2016-10-01 00:00:00

  • Fracture strength of zirconia implants after artificial aging.

    abstract:BACKGROUND:Zirconia (ZrO(2)) might be an alternative material to titanium (Ti) for dental implant fabrication. However, no data are available on the fracture strength of one-piece ZrO(2) oral implants. PURPOSE:The objective of this study was to evaluate the fracture strength of ZrO(2) implants after exposure to the ar...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00105.x

    authors: Andreiotelli M,Kohal RJ

    更新日期:2009-06-01 00:00:00

  • The effect of a 2-mm inter-implant distance on esthetic outcomes in immediately non-occlusally loaded platform shifted implants in healed ridges: 12-month results of a randomized clinical trial.

    abstract:BACKGROUND:Three millimeter is considered as the minimum distance to obtain soft and bone tissue stability in case of adjacent implants. The possibility to preserve peri-implant bone level using a platform switching connection has questioned this concept. PURPOSE:The study evaluates soft tissue maintenance and margina...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12926

    authors: Rivara F,Macaluso GM,Toffoli A,Calciolari E,Goldoni M,Lumetti S

    更新日期:2020-08-01 00:00:00

  • A long-term prospective cohort study on immediately restored single tooth implants inserted in extraction sockets and healed ridges: CBCT analyses, soft tissue alterations, aesthetic ratings, and patient-reported outcomes.

    abstract:BACKGROUND:Although many studies have been published on single implants, long-term data remain scarce. PURPOSE:To evaluate immediately restored single implants after at least 8 years of follow-up in terms of buccal bone, soft tissue alterations, aesthetic ratings, and patient-reported outcomes. MATERIALS AND METHODS:...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12613

    authors: Raes S,Eghbali A,Chappuis V,Raes F,De Bruyn H,Cosyn J

    更新日期:2018-08-01 00:00:00

  • Terminal Posterior Tilted Implants Planned as a Sinus Graft Alternative for Fixed Full-Arch Implant-Supported Maxillary Restoration: A Case Series with 10- to 19-Year Results on 44 Consecutive Patients Presenting for Routine Maintenance.

    abstract:PURPOSE:Posterior maxillary tilted implants are gaining prevalence as an alternative to sinus grafts supporting fixed maxillary restorations. This paper reports long-term results after loading using this technique. MATERIALS AND METHODS:Consecutive patients presenting for either routine hygiene maintenance or unplanne...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12433

    authors: Fortin Y,Sullivan RM

    更新日期:2017-02-01 00:00:00

  • The precision of fit of milled titanium implant frameworks (I-Bridge) in the edentulous jaw.

    abstract:BACKGROUND:New computer numeric controlled (CNC)-milled frameworks for implant-supported prostheses have been introduced. However, no data are available on the precision of fit of these new frameworks. PURPOSE:The purpose of this study is to evaluate the precision of fit of a new CNC-milled framework technique (I-Brid...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00131.x

    authors: Eliasson A,Wennerberg A,Johansson A,Ortorp A,Jemt T

    更新日期:2010-06-01 00:00:00

  • Contact analysis of gap formation at dental implant-abutment interface under oblique loading: A numerical-experimental study.

    abstract:PURPOSE:To develop numerical and experimental methods for investigating the formation of micro-gaps and the change in contact area at the implant-abutment interface of two different connector designs under oblique cyclic loading. MATERIALS AND METHODS:Samples (n = 10 per group) of two-piece implant systems with the co...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12792

    authors: He Y,Fok A,Aparicio C,Teng W

    更新日期:2019-08-01 00:00:00

  • Hybrid and fully-etched surface implants in periodontally healthy patients: A comparative retrospective study on marginal bone loss.

    abstract:BACKGROUND:Human studies on implants with the same design but with different surfaces are lacking at the present time. PURPOSE:The aim of this study was to compare the survival rate of and marginal bone loss (MBL) around 2 types of implants with the same design, but with different surfaces: fully "sandblasted and doub...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12504

    authors: Spinato S,Bernardello F,Sassatelli P,Zaffe D

    更新日期:2017-08-01 00:00:00

  • Buccal bone thickness at dental implants in the maxillary anterior region with large bony defects at time of immediate implant placement: A 1-year cohort study.

    abstract:BACKGROUND:There is lack of studies regarding preservation and possible changes in BBT at dental implants. PURPOSE:To assess, on cone beam computer tomograms, the presence of bone at the time of tooth extraction in the maxillary esthetic region and the mean buccal bone thickness 1 month and 1 year after final restorat...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12701

    authors: Meijer HJA,Slagter KW,Vissink A,Raghoebar GM

    更新日期:2019-02-01 00:00:00

  • Accuracy of linear measurement provided by cone beam computed tomography to assess bone quantity in the posterior maxilla: a human cadaver study.

    abstract:PURPOSE:The aim of this study was to assess, for implant placement in the posterior maxilla, the accuracy of linear measurements provided by cone beam computed tomography (CBCT) using an image intensifier tube and television (TV) chain as an X-ray detector despite a loss of contrast resolution. The NewTom 9000 (Quantit...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00083.x

    authors: Veyre-Goulet S,Fortin T,Thierry A

    更新日期:2008-12-01 00:00:00

  • Implant-Supported Single Crowns Replacing Congenitally Missing Maxillary Lateral Incisors: A 5-Year Follow-Up.

    abstract:BACKGROUND:Knowledge of the long-term survival of single implants in cases of congenitally missing lateral incisors in the maxilla is limited. PURPOSE:This retrospective study aimed to evaluate the 5-year survival of implants and implant-supported crowns (ISCs) and to assess the functional and aesthetic outcomes from ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12233

    authors: Branzén M,Eliasson A,Arnrup K,Bazargani F

    更新日期:2015-12-01 00:00:00

  • Infraposition of anterior maxillary implant-supported single-tooth restorations in adolescent and adult patients-A prospective follow-up study up to 6 years.

    abstract:BACKGROUND:In the maxillary incisor area infraposition of implant restorations can be an esthetic problem. PURPOSE:The aim was to analyze the prevalence of infraposition of single-tooth implant restorations in the anterior maxilla in adolescent and adult patients. MATERIAL AND METHODS:The study comprised of 31 patien...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12818

    authors: Nilsson A,Johansson LÅ,Stenport VF,Wennerberg A,Ekfeldt A

    更新日期:2019-10-01 00:00:00

  • Bone formation at titanium implants prepared with iso- and anisotropic surfaces of similar roughness: an in vivo study.

    abstract:BACKGROUND:Implant surface topography influences the bone response after implantation. However, the importance of surface orientation is not known. PURPOSE:The aim of this study was to investigate the bone tissue response and the stability of titanium implants prepared with isotropic and anisotropic surfaces of simila...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2005.tb00042.x

    authors: Göransson A,Wennerberg A

    更新日期:2005-01-01 00:00:00

  • Location of implant-retained fixed dentures affects oral health-related quality of life.

    abstract:BACKGROUND:The effects of the locations of dental implants on treatment outcomes, as evaluated by oral health-related quality of life (OHRQoL) assessment, remain controversial. PURPOSE:To investigate the association between the locations of dental implants and changes in OHRQoL. MATERIALS AND METHODS:Sixty-eight subj...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12497

    authors: Hara M,Matsumoto T,Yokoyama S,Higuchi D,Baba K

    更新日期:2017-08-01 00:00:00

  • Immediate rehabilitation of the extremely atrophic mandible with fixed full-prosthesis supported by four implants.

    abstract:PURPOSE:To prospectively assess the outcome of immediate rehabilitation of extremely atrophic mandibles by a full-arch fixed bridge anchored to four implants. MATERIAL AND METHODS:Twenty patients with edentulous mandibles were included in the study. Each patient received a full-arch fixed bridge supported by two axial...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1708-8208.2009.00265.x

    authors: Weinstein R,Agliardi E,Fabbro MD,Romeo D,Francetti L

    更新日期:2012-06-01 00:00:00

  • Immediate loading of two implants with a mandibular implant-retained overdenture: a new treatment protocol.

    abstract:PURPOSE:The aim of this study was to present the clinical outcomes of the immediate loading of two bar-splinted implants retaining a mandibular overdenture. MATERIALS AND METHODS:In a clinical trial, 124 edentulous patients were treated according to a new treatment concept, which involves the immediate loading of two ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1708-8208.2009.00210.x

    authors: Stoker GT,Wismeijer D

    更新日期:2011-12-01 00:00:00

  • Longitudinal analysis on the effect of insertion torque on delayed single implants: A 3-year randomized clinical study.

    abstract:BACKGROUND:Implant stability is commonly related to insertion torque. Recently, it has been suggested that higher insertion torque may lead to greater bone resorption. PURPOSE:The aim of the present randomized clinical study was to evaluate the role of different insertion torque values in terms of implant success, mar...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12586

    authors: Marconcini S,Giammarinaro E,Toti P,Alfonsi F,Covani U,Barone A

    更新日期:2018-06-01 00:00:00

  • One-year outcome of implants strategically placed in the retrocanine bone triangle.

    abstract:BACKGROUND:Implant treatment in the partially edentulous maxilla is often challenging because of minimum bone volumes in distal direction. PURPOSE:The aim of this study was to evaluate, after 1 year of loading, the outcome of three-unit fixed partial dentures supported by two implants in the retrocanine triangle. MAT...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00170.x

    authors: Balleri P,Ferrari M,Veltri M

    更新日期:2010-12-01 00:00:00

  • Turned, machined versus double-etched dental implants in vivo.

    abstract:BACKGROUND:Positive effects on the clinical outcome of moderately rough implant surfaces are described. Intercomparison of clinical data, however, is rarely found. PURPOSE:The aim of this study was to compare the clinical results of two macroscopically identical implants, the one with a turned, machined and the other ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2007.00030.x

    authors: Al-Nawas B,Hangen U,Duschner H,Krummenauer F,Wagner W

    更新日期:2007-06-01 00:00:00

  • Does Timing of Implant Placement Affect Implant Therapy Outcome in the Aesthetic Zone? A Clinical, Radiological, Aesthetic, and Patient-Based Evaluation.

    abstract:PURPOSE:To compare five different implant treatment protocols in the anterior maxilla, including immediate, early, and delayed implant placement, as well as implant placement in conjunction with simultaneous guided bone regeneration and implant placement 3 months following horizontal autologous bone block grafting. MA...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12212

    authors: Hof M,Pommer B,Ambros H,Jesch P,Vogl S,Zechner W

    更新日期:2015-12-01 00:00:00

  • The influence of bone type on the gene expression in normal bone and at the bone-implant interface: experiments in animal model.

    abstract:BACKGROUND:Studies on the biological processes in different bone types and the reaction of different bone types to biomaterials are often hindered because of the difficulties in sampling procedures and lack of sensitive techniques. PURPOSE:The purpose was to assess the suitability of quantitative polymerase chain reac...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00195.x

    authors: Omar O,Suska F,Lennerås M,Zoric N,Svensson S,Hall J,Emanuelsson L,Nannmark U,Thomsen P

    更新日期:2011-06-01 00:00:00

  • Elevated levels of 8-OHdG and PARK7/DJ-1 in peri-implantitis mucosa.

    abstract:BACKGROUND:Reactive oxygen species contribute to periodontal tissue homeostasis under control of anti-oxidative responses. Disruption in this balance induces severe inflammation and extended tissue degradation. PURPOSE:Aim of this study was to identify the expression levels of nuclear factor, erythroid 2 like 2 (NFE2L...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12619

    authors: Kasnak G,Firatli E,Könönen E,Olgac V,Zeidán-Chuliá F,Gursoy UK

    更新日期:2018-08-01 00:00:00

  • Five-year evaluation of Lifecore Restore implants: a retrospective comparison with Nobel Biocare MK II implants.

    abstract:PURPOSE:The purpose of this study was to compare survival rates and marginal bone resorption of the Lifecore (LC) Restore Implant System with the benchmark Nobel Biocare (NB) MK II Implant System. MATERIALS AND METHODS:All implants were inserted by the same surgeon and all radiological analyses were performed by the s...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00115.x

    authors: Kallus T,Bessing C,Homsi G,Eklund I

    更新日期:2009-09-01 00:00:00

  • The effects of cortical bone thickness and trabecular bone strength on noninvasive measures of the implant primary stability using synthetic bone models.

    abstract:PURPOSE:This study investigated how the primary stability of a dental implant as measured by the insertion torque value (ITV), Periotest value (PTV), and implant stability quotient (ISQ) is affected by varying thicknesses of cortical bone and strengths of trabecular bone using synthetic bone models. MATERIALS AND METH...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00349.x

    authors: Hsu JT,Fuh LJ,Tu MG,Li YF,Chen KT,Huang HL

    更新日期:2013-04-01 00:00:00

  • Healing of extraction sockets filled with BoneCeramic® prior to implant placement: preliminary histological findings.

    abstract:BACKGROUND:Various grafting materials have been designed to minimize edentulous ridge volume loss following tooth extraction by encouraging new bone formation in healing sockets. BoneCeramic® is a composite of hydroxyapatite and bèta-tricalcium phosphate with pores of 100-500 microns. PURPOSES:The aim of this study wa...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00184.x

    authors: De Coster P,Browaeys H,De Bruyn H

    更新日期:2011-03-01 00:00:00

  • Immediate/early loading of dental implants: a report from the Sociedad Española de Implantes World Congress consensus meeting in Barcelona, Spain, 2002.

    abstract:BACKGROUND:Immediate/early loading protocols are becoming frequently used in implant dentistry, but the prerequisites for achieving good results and the limitations of such protocols are not fully known. Moreover, the terminology used in immediate/early loading is still confusing. PURPOSE:The purpose of this article i...

    journal_title:Clinical implant dentistry and related research

    pub_type: 共识发展会议,杂志文章,评审

    doi:10.1111/j.1708-8208.2003.tb00183.x

    authors: Aparicio C,Rangert B,Sennerby L

    更新日期:2003-01-01 00:00:00

  • The Effect of Hierarchical Micro/Nanotextured Titanium Implants on Osseointegration Immediately After Tooth Extraction in Beagle Dogs.

    abstract:BACKGROUND:Owing to simplify the operation and shorten the overall duration of treatment, immediate implantation earned much satisfactory from patients and dentists. The results of immediate implantation determined by osseointegration, we fabricated a micro/nanotextured titanium implants to improve osseointegration imm...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12464

    authors: Fu Q,Bellare A,Cui Y,Cheng B,Xu S,Kong L

    更新日期:2017-06-01 00:00:00

  • Addition of a Synthetically Fabricated Osteoinductive Biphasic Calcium Phosphate Bone Graft to BMP2 Improves New Bone Formation.

    abstract:BACKGROUND:Bone morphogenetic protein-2 (BMP2) has been successfully utilized in dentistry to promote new bone formation because of its osteoinductive ability to recruit mesenchymal progenitor cells and induce their differentiation to bone-forming osteoblasts. Recently, novel biphasic calcium phosphate scaffolds have b...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12384

    authors: Zhang Y,Yang S,Zhou W,Fu H,Qian L,Miron RJ

    更新日期:2016-12-01 00:00:00

  • Relationship between self-rated pain and peri-implant clinical, radiographic and whole salivary inflammatory markers among patients with and without peri-implantitis.

    abstract:BACKGROUND:There are no studies that have evaluated the correlation between self-rated pain, peri-implant clinical and radiographic parameters (plaque index [PI], bleeding on probing [BOP], probing depth [PD], and crestal bone loss [CBL]) and whole salivary interleukin (IL)-1β, IL-6, and tumor necrosis factor-alpha (TN...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12866

    authors: Abduljabbar T,Vohra F,Ullah A,Alhamoudi N,Khan J,Javed F

    更新日期:2019-12-01 00:00:00