The precision of fit of milled titanium implant frameworks (I-Bridge) in the edentulous jaw.

Abstract:

BACKGROUND:New computer numeric controlled (CNC)-milled frameworks for implant-supported prostheses have been introduced. However, no data are available on the precision of fit of these new frameworks. PURPOSE:The purpose of this study is to evaluate the precision of fit of a new CNC-milled framework technique (I-Bridge, Biomain AB, Helsingborg, Sweden) using Brånemark System (Nobel Biocare AB, Göteborg, Sweden) and NobelReplace (Nobel Biocare AB) system implants. MATERIALS AND METHODS:Ten test frameworks were fabricated for one master model for each implant system. Five additional frameworks were fabricated for five different models simulating clinical cases as controls (Brånemark System). The distortion of implant center point positions was measured in x-, y-, and z-axes and in three dimensions by using a contact-type coordinate measuring machine and a computer program developed specifically for this purpose. Mann-Whitney U-test was used to compare differences of distortion within and between the groups. RESULTS:The maximal distortion in arch width (x-axis) and curvature (y-axis) was within 71 and 55 microm for all frameworks, respectively. The mean distortion in absolute figures in x-, y-, z-axes and three dimensions was for "clinical control" frameworks 23, 26, 4, and 34 microm as compared with less than 12, 12, 2, and 17 microm for Brånemark and NobelReplace frameworks, respectively. Control frameworks showed significantly (p < .05) greater mean and range of distortions in x- and y-axes and in three dimensions compared with test frameworks. CONCLUSION:All measured frameworks presented signs of misfit, indicating that no framework had a "passive fit." Frameworks produced in a more routine clinical environment seem to present greater levels of distortion as compared with frameworks produced in a strict test situation. However, all measured frameworks presented levels of precision of fit within limits considered to be clinically acceptable in earlier studies of frameworks placed on abutments.

authors

Eliasson A,Wennerberg A,Johansson A,Ortorp A,Jemt T

doi

10.1111/j.1708-8208.2008.00131.x

subject

Has Abstract

pub_date

2010-06-01 00:00:00

pages

81-90

issue

2

eissn

1523-0899

issn

1708-8208

pii

CID131

journal_volume

12

pub_type

杂志文章
  • The midline mandibular lingual canal: importance in implant surgery.

    abstract:PURPOSE:The study aims to determine if midline mandibular dental implants pose a risk for the midline lingual canal (MLC). MATERIALS AND METHODS:Cone beam computed tomography was used to scan 122 mandibles (31 black males; 28 black females; 32 white males and 31 white females). Midsagittal sections in the reconstructe...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12080

    authors: Oettlé AC,Fourie J,Human-Baron R,van Zyl AW

    更新日期:2015-02-01 00:00:00

  • Immediate implant placement combined with maxillary sinus floor elevation utilizing the transalveolar approach and nonsubmerged healing for failing teeth in the maxillary molar area: A randomized controlled trial clinical study with one-year follow-up.

    abstract:BACKGROUND:In previous studies, immediate implant placement in molar sites has been widely applied. PURPOSE:To study the clinical effect and feasibility of immediate implant placement combined with maxillary sinus floor elevation utilizing the transalveolar approach and nonsubmerged healing for failing teeth in the ma...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12783

    authors: Liu H,Liu R,Wang M,Yang J

    更新日期:2019-06-01 00:00:00

  • The influence of wound closure on graft stability: An in vitro comparison of different bone grafting techniques for the treatment of one-wall horizontal bone defects.

    abstract:OBJECTIVES:The aim of this preclinical study was to analyze and compare different grafting techniques with respect to volume stability after wound closure. MATERIALS AND METHODS:Four different grafting techniques were evaluated in vitro for volume stability in a one-wall horizontal defect configuration. Group 1: guide...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12728

    authors: Mertens C,Braun S,Krisam J,Hoffmann J

    更新日期:2019-04-01 00:00:00

  • Peri-implant parameters and C-reactive protein levels among patients with different obesity levels.

    abstract:BACKGROUND:It is hypothesized that peri-implant conditions are worse with increasing severity of obesity, because systemic low-grade inflammatory marker (C-reactive protein [CRP]) is higher in severe form of obese individuals. PURPOSE:The aim of the cross-sectional retrospective study was to compare clinical and radio...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12556

    authors: Vohra F,Alkhudhairy F,Al-Kheraif AA,Akram Z,Javed F

    更新日期:2018-04-01 00:00:00

  • Addition of a Synthetically Fabricated Osteoinductive Biphasic Calcium Phosphate Bone Graft to BMP2 Improves New Bone Formation.

    abstract:BACKGROUND:Bone morphogenetic protein-2 (BMP2) has been successfully utilized in dentistry to promote new bone formation because of its osteoinductive ability to recruit mesenchymal progenitor cells and induce their differentiation to bone-forming osteoblasts. Recently, novel biphasic calcium phosphate scaffolds have b...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12384

    authors: Zhang Y,Yang S,Zhou W,Fu H,Qian L,Miron RJ

    更新日期:2016-12-01 00:00:00

  • Fibrin clot extension on zirconia surface for dental implants: a quantitative in vitro study.

    abstract:PURPOSE:The surface chemical and physical properties of materials used for implants have a major influence on blood clot organization. This study aims to evaluate the blood clot extension (bce) on zirconia and titanium. bce was measured in association to surface roughness (Ra) and static contact angle (θ). MATERIALS A...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12038

    authors: Traini T,Caputi S,Gherlone E,Degidi M,Piattelli A

    更新日期:2014-10-01 00:00:00

  • A retro-prospective long-term follow-up of Brånemark single implants in the anterior maxilla in young adults. Part 1: Clinical and radiographic parameters.

    abstract:BACKGROUND:Single implant restorations have become the primary treatment option for young adults with missing anterior teeth. Yet, long-term studies of single-implants are limited in the literature. PURPOSE:To report long-term survival, success, and complications in young adults with single-implants in the anterior ma...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12673

    authors: Winitsky N,Olgart K,Jemt T,Smedberg JI

    更新日期:2018-12-01 00:00:00

  • Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading.

    abstract:BACKGROUND:Rigorous efforts to reduce the recurrence of abutment screw loosening in single-tooth implant restorations have recently been made. However, the behavior of the implant/abutment joint components with respect to critical bending force is still unclear. PURPOSE:This study investigated the effect of different ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2004.tb00216.x

    authors: Khraisat A,Abu-Hammad O,Dar-Odeh N,Al-Kayed AM

    更新日期:2004-01-01 00:00:00

  • Outcome of peri-implant maintenance care in patients with an implant-supported lower denture-A 3.5-year retrospective analysis.

    abstract:BACKGROUND:Implant-supported overdentures represent a successful treatment for edentulous patients. As early diagnosis, detection and supportive care are considered key factors for the prevention of peri-implant diseases, consistent maintenance of these implants is becoming increasingly relevant. PURPOSE:This retrospe...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12963

    authors: van der Moolen PL,Post BJ,Slot DE,van der Weijden FA

    更新日期:2021-01-18 00:00:00

  • The effects of cortical bone thickness and trabecular bone strength on noninvasive measures of the implant primary stability using synthetic bone models.

    abstract:PURPOSE:This study investigated how the primary stability of a dental implant as measured by the insertion torque value (ITV), Periotest value (PTV), and implant stability quotient (ISQ) is affected by varying thicknesses of cortical bone and strengths of trabecular bone using synthetic bone models. MATERIALS AND METH...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00349.x

    authors: Hsu JT,Fuh LJ,Tu MG,Li YF,Chen KT,Huang HL

    更新日期:2013-04-01 00:00:00

  • Biomedical Ti-Mo alloys with surface machined and modified by laser beam: biomechanical, histological, and histometric analysis in rabbits.

    abstract:PURPOSE:In vivo bone response was assessed by removal torque, hystological and histometrical analysis on a recently developed biomedical Ti-15Mo alloy, after surface modification by laser beam irradiation, installed in the tibia of rabbits. MATERIALS AND METHODS:A total of 32 wide cylindrical Ti-15Mo dental implants w...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00354.x

    authors: Oliveira NT,Guastaldi FP,Perrotti V,Hochuli-Vieira E,Guastaldi AC,Piattelli A,Iezzi G

    更新日期:2013-06-01 00:00:00

  • Evaluation of immediate cell viability and repair of osteotomies for implants using drills and piezosurgery. A randomized, prospective, and controlled rabbit study.

    abstract:PURPOSE:The objective of this study was to evaluate the immediate bone damage and bone repair after osteotomy for implants using conventional drills and drills powered by piezoelectric motor. MATERIALS AND METHODS:Twelve rabbits received a tibial osteotomy with a conventional drill (control), with a diamond like carbo...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12907

    authors: Ponzoni D,Martins FEPB,Conforte JJ,Egas LS,Tonini KR,de Carvalho PSP

    更新日期:2020-06-01 00:00:00

  • The influence of bone type on the gene expression in normal bone and at the bone-implant interface: experiments in animal model.

    abstract:BACKGROUND:Studies on the biological processes in different bone types and the reaction of different bone types to biomaterials are often hindered because of the difficulties in sampling procedures and lack of sensitive techniques. PURPOSE:The purpose was to assess the suitability of quantitative polymerase chain reac...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00195.x

    authors: Omar O,Suska F,Lennerås M,Zoric N,Svensson S,Hall J,Emanuelsson L,Nannmark U,Thomsen P

    更新日期:2011-06-01 00:00:00

  • Comparison of fit accuracy between Procera® custom abutments and three implant systems.

    abstract:BACKGROUND:Although increase of misfit has been reported when associating implant and abutment from different manufacturers, Procera custom abutment has been universally used in clinical practice. PURPOSE:The purpose of this investigation was to compare the vertical gap of zirconia Procera® abutment associated with im...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2010.00323.x

    authors: de Morais Alves da Cunha T,de Araújo RP,da Rocha PV,Amoedo RM

    更新日期:2012-12-01 00:00:00

  • Changes of Marginal Bone Level in Patients with "Progressive Bone Loss" at Brånemark System® Implants: A Radiographic Follow-Up Study over an Average of 9 Years.

    abstract:BACKGROUND:Patients have in many studies been identified with progressive bone loss and peri-implantitis problems, but few studies are available where these groups of patients have been followed up. PURPOSE:The purpose of this paper is to study further progression of bone loss in a cohort of 182 patients that have bee...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12166

    authors: Jemt T,Sundén Pikner S,Gröndahl K

    更新日期:2015-08-01 00:00:00

  • Bone formation at titanium implants prepared with iso- and anisotropic surfaces of similar roughness: an in vivo study.

    abstract:BACKGROUND:Implant surface topography influences the bone response after implantation. However, the importance of surface orientation is not known. PURPOSE:The aim of this study was to investigate the bone tissue response and the stability of titanium implants prepared with isotropic and anisotropic surfaces of simila...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2005.tb00042.x

    authors: Göransson A,Wennerberg A

    更新日期:2005-01-01 00:00:00

  • Clinical and radiographic outcomes of reentry lateral sinus floor elevation after a complete membrane perforation.

    abstract:BACKGROUND:Although small perforation of the maxillary sinus schneiderian membrane is a well-documented complication during lateral sinus floor elevation (LSFE), complete perforations larger than 10 mm often result in discontinuation of surgery. Reports on reentry LSFE and its long-term outcomes are sparse. PURPOSE:To...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12932

    authors: Wang D,Tian J,Wang Y,Wei D,Lin Y

    更新日期:2020-10-01 00:00:00

  • Microbiology and cytokine levels around healthy dental implants and teeth.

    abstract:BACKGROUND:Elicitation of the relationship of periodontopathogens and pro-inflammatory cytokines to bone resorption and formation is significant to a growing body of research known as osteoimmunology. It is essential that clinically healthy peri-implant and periodontal sites are studied to contribute comparison data fo...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2007.00076.x

    authors: Nowzari H,Botero JE,DeGiacomo M,Villacres MC,Rich SK

    更新日期:2008-09-01 00:00:00

  • Long-term clinical, microbiological, and radiographic outcomes of Brånemark™ implants installed in augmented maxillary bone for fixed full-arch rehabilitation.

    abstract:PURPOSE:The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS:Patients of a periodontal practice who had been referred to a maxillofacial surgeon for i...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00359.x

    authors: De Bruyn H,Bouvry P,Collaert B,De Clercq C,Persson GR,Cosyn J

    更新日期:2013-02-01 00:00:00

  • Immediate implant in the posterior region combined with alveolar ridge preservation and sealing socket abutment: A retrospective 3D radiographic analysis.

    abstract:BACKGROUND:Customized sealing socket abutment (SSA) has been claimed to optimize the peri-implant hard and soft tissues in type 1 implant placement. However, the evidence to claim the benefits of this technique over the use a conventional healing abutment remains weak. PURPOSE:The aim of this retrospective study was t...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12974

    authors: Alexopoulou M,Lambert F,Knafo B,Popelut A,Vandenberghe B,Finelle G

    更新日期:2021-01-13 00:00:00

  • RFA values of implants placed in sinus grafted and nongrafted sites after 6 and 12 months.

    abstract:BACKGROUND:Maxillary sinus floor elevation surgery is widely used as a preimplantology method to permit implant insertion. Nevertheless, very few data are available about long-term stability of dental implants inserted in grafted sites. PURPOSE:The aims of the present study were to evaluate the evolution of resonance ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00113.x

    authors: Degidi M,Daprile G,Piattelli A

    更新日期:2009-09-01 00:00:00

  • Monolithic implant-supported lithium disilicate (LS2) crowns in a complete digital workflow: A prospective clinical trial with a 2-year follow-up.

    abstract:BACKGROUND:The technical development of digital processing allows the production of anatomically full-contoured implant-supported restorations. PURPOSE:The aim of this prospective clinical trial was to analyze the treatment concept of monolithic lithium disilicate (LS2) single-unit restorations in a complete digital w...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/cid.12472

    authors: Joda T,Ferrari M,Brägger U

    更新日期:2017-06-01 00:00:00

  • Temporary implants for patients with low bone density of the upper maxilla: an alternative rehabilitation strategy.

    abstract:BACKGROUND:The use of removable provisional prosthesis after implant placement is undesirable for many patients. In addition, removable prostheses place unfavorable pressure over implants during the healing period. PURPOSE:The use of temporary implants enable greater stability and functionality of the prostheses. MAT...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00225.x

    authors: de Aguiar RC,Zabolotsky B,de Souza DC,Ferreira CF,Cardoso AC

    更新日期:2012-03-01 00:00:00

  • The Risk of Prion Infection through Bovine Grafting Materials.

    abstract:BACKGROUND:Bovine-derived grafting materials are frequently used in a variety of bone augmentation techniques. The aim of this paper is to assess the unique safety issue of bovine-derived grafting materials that is rarely addressed in dental literature: risk of bovine spongiform encephalopathy (BSE). METHODS:The valid...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12391

    authors: Kim Y,Rodriguez AE,Nowzari H

    更新日期:2016-12-01 00:00:00

  • A Human Clinical, Histological, Histomorphometrical, and Radiographical Study on Biphasic HA-Beta-TCP 30/70 in Maxillary Sinus Augmentation.

    abstract:BACKGROUND:By mixing hydroxyapatite (HA) and tricalcium phosphate (TCP), biphasic calcium phosphate ceramics can be obtained, and by varying their ratio it is possible to tailor the characteristics of the biomaterial. PURPOSE:The aim of the present human study was to evaluate the histological and radiographical aspect...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12145

    authors: Mangano C,Sinjari B,Shibli JA,Mangano F,Hamisch S,Piattelli A,Perrotti V,Iezzi G

    更新日期:2015-06-01 00:00:00

  • Orthodontic mini-implant stability under continuous or intermittent loading: a histomorphometric and biomechanical analysis.

    abstract:BACKGROUND:Both continuous and intermittent loadings are commonly applied in orthodontics. Clinical experiences and some studies believed that longer duration of force produce more effect (tooth movement, suture expansion, bone remodeling) than transient forces applied with the same magnitude. Alternatively, others ind...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12090

    authors: Wu Y,Xu Z,Tan L,Tan L,Zhao Z,Yang P,Li Y,Tang T,Zhao L

    更新日期:2015-02-01 00:00:00

  • Syncrystallization: a technique for temporization of immediately loaded implants with metal-reinforced acrylic resin restorations.

    abstract:BACKGROUND:Rigid temporization has been recognized to have a significant impact on the peri-implant tissue response in immediate implant loading since it reduces the mechanical stress exerted on each implant. PURPOSE:A successful protocol for immediate loading of multiple implants depends on an adequate fixation and i...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2006.00011.x

    authors: Degidi M,Gehrke P,Spanel A,Piattelli A

    更新日期:2006-01-01 00:00:00

  • Experimental evaluation in rabbits of the effects of thread concavities in bone formation with different titanium implant surfaces.

    abstract:BACKGROUND:Differences in implant microtexture are important in conditioning the bone response around dental implants. PURPOSE:The aim of the present study was an evaluation of the bone response in machined (M), blasted with apatitic calcium phosphate (tricalcium phosphate/hydrossyapatite [HA] blend) particles (resorb...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12033

    authors: Scarano A,Degidi M,Perrotti V,Degidi D,Piattelli A,Iezzi G

    更新日期:2014-08-01 00:00:00

  • "Three-in-one" patient-specific surgical guides for simultaneous dental implants in fibula flap jaw reconstruction: A prospective case series.

    abstract:BACKGROUND:Conventional freehand immediate placement of dental implants is technically challenging in the jaw reconstructive surgery. Computer-aided surgery might be the best solution, however, there has not been any standard approach to ensure the accuracy and efficiency of simultaneous dental implants in fibula flap ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12954

    authors: Zhu WY,Su YX,Pow EHN,Yang WF,Qin L,Choi WS

    更新日期:2020-11-12 00:00:00

  • Histomorphometrical analysis following augmentation of infected extraction sites exhibiting severe bone loss and primarily closed by intrasocket reactive soft tissue.

    abstract:BACKGROUND:Intrasocket reactive soft tissue can be used for primary closure during augmentation of infected extraction sites exhibiting severe bone loss prior to implant placement. The present study evaluated the histological characteristics of the initially used intrasocket reactive soft tissue, the overlying soft tis...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2010.00281.x

    authors: Mardinger O,Vered M,Chaushu G,Nissan J

    更新日期:2012-06-01 00:00:00