Comparison of fit accuracy between Procera® custom abutments and three implant systems.

Abstract:

BACKGROUND:Although increase of misfit has been reported when associating implant and abutment from different manufacturers, Procera custom abutment has been universally used in clinical practice. PURPOSE:The purpose of this investigation was to compare the vertical gap of zirconia Procera® abutment associated with implants from the same manufacturer (Procera manufacturer) and two other implant systems. MATERIALS AND METHODS:Twenty-four zirconia Procera abutments were produced using computer-assisted design and manufacture and paired with (a) eight MK III, RP 4.1 × 10 mm implants (Nobel Biocare™, Göteborg, Sweden) - GNB group (Nobel Biocare group); (b) eight Try on, 4.1 × 10 mm implants (Sistema de Implantes, São Paulo, Brazil) - ES group (SIN experimental group) ; and (c) eight Master screw, 4.1 × 10 mm implants (Conexão® Sistema de Prótese, São Paulo, Brazil) - EC group (Conexão experimental group). A comparison of the vertical misfit at the implant-abutment interface was taken at six measuring sites on each sample using scanning electron microscopy with a magnification of 408×. One-way analysis of variance was used to test for differences, and Tukey's test was used for pair-wise comparison of groups (α = 0.05). RESULTS:Significant differences relative to average misfit were found when Procera abutments were associated with other implant manufacturers. The ES group and EC group did not differ significantly, but both demonstrated significantly larger average misfit than the GNB group (p = .001). The average misfit was 5.7 µm ± 0.39, 9.53 µm ± 0.52, and 10.62 µm ± 2.16, respectively, for groups GNB, ES, and EC. CONCLUSION:The association of Procera zirconia abutment with other implant systems different from its manufacturer demonstrated significant alteration of vertical misfit at implant-abutment interface.

authors

de Morais Alves da Cunha T,de Araújo RP,da Rocha PV,Amoedo RM

doi

10.1111/j.1708-8208.2010.00323.x

subject

Has Abstract

pub_date

2012-12-01 00:00:00

pages

890-5

issue

6

eissn

1523-0899

issn

1708-8208

journal_volume

14

pub_type

杂志文章
  • Clinical and radiographic outcomes of reentry lateral sinus floor elevation after a complete membrane perforation.

    abstract:BACKGROUND:Although small perforation of the maxillary sinus schneiderian membrane is a well-documented complication during lateral sinus floor elevation (LSFE), complete perforations larger than 10 mm often result in discontinuation of surgery. Reports on reentry LSFE and its long-term outcomes are sparse. PURPOSE:To...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12932

    authors: Wang D,Tian J,Wang Y,Wei D,Lin Y

    更新日期:2020-10-01 00:00:00

  • Jaw Bone Samples From Bisphosphonate-Treated Patients: A Pilot Cohort Study.

    abstract:UNLABELLED:Osteonecrosis of the jaw (ONJ) is a severe complication of bisphosphonate treatment. PURPOSE:A detailed characterization of sampled peri-necrotic jawbone from bisphosphonate-treated patients was performed at tissue and cellular level (histological analyses and gene expression). MATERIALS AND METHODS:Alveol...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12307

    authors: Cardemil C,Thomsen P,Larsson Wexell C

    更新日期:2015-10-01 00:00:00

  • The Risk of Prion Infection through Bovine Grafting Materials.

    abstract:BACKGROUND:Bovine-derived grafting materials are frequently used in a variety of bone augmentation techniques. The aim of this paper is to assess the unique safety issue of bovine-derived grafting materials that is rarely addressed in dental literature: risk of bovine spongiform encephalopathy (BSE). METHODS:The valid...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12391

    authors: Kim Y,Rodriguez AE,Nowzari H

    更新日期:2016-12-01 00:00:00

  • Microstructure of titanium-cement-lithium disilicate interface in CAD-CAM dental implant crowns: a three-dimensional profilometric analysis.

    abstract:BACKGROUND:Peri-implantitis is an infection of the implant surface caused by adhesion of bacteria that generate bone resorption and sometimes even consequent implant loss. Both screw-retained and cemented fixed implants are affected. PURPOSE:The purpose of this study is to investigate the morphological defects at the ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12133

    authors: Cresti S,Itri A,Rebaudi A,Diaspro A,Salerno M

    更新日期:2015-01-01 00:00:00

  • Nonsubmerged implants in the treatment of the edentulous lower jaw: a 5-year prospective longitudinal study of ITI hollow screws.

    abstract:BACKGROUND:Although most implant systems have been designed for a two-stage surgical technique, a one-stage surgical technique has always been advocated for the ITI Dental Implant System (Straumann AG, Waldenburg, Switzerland). A new generation of ITI implants was presented in 1988 and included a hollow cylinder, a hol...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2001.tb00125.x

    authors: Hellem S,Karlsson U,Almfeldt I,Brunell G,Hamp SE,Astrand P

    更新日期:2001-01-01 00:00:00

  • Immediate implant in the posterior region combined with alveolar ridge preservation and sealing socket abutment: A retrospective 3D radiographic analysis.

    abstract:BACKGROUND:Customized sealing socket abutment (SSA) has been claimed to optimize the peri-implant hard and soft tissues in type 1 implant placement. However, the evidence to claim the benefits of this technique over the use a conventional healing abutment remains weak. PURPOSE:The aim of this retrospective study was t...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12974

    authors: Alexopoulou M,Lambert F,Knafo B,Popelut A,Vandenberghe B,Finelle G

    更新日期:2021-01-13 00:00:00

  • Histomorphometrical analysis following augmentation of infected extraction sites exhibiting severe bone loss and primarily closed by intrasocket reactive soft tissue.

    abstract:BACKGROUND:Intrasocket reactive soft tissue can be used for primary closure during augmentation of infected extraction sites exhibiting severe bone loss prior to implant placement. The present study evaluated the histological characteristics of the initially used intrasocket reactive soft tissue, the overlying soft tis...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2010.00281.x

    authors: Mardinger O,Vered M,Chaushu G,Nissan J

    更新日期:2012-06-01 00:00:00

  • Topography, microhardness, and precision of fit on ready-made zirconia abutment before/after sintering process.

    abstract:BACKGROUND:Sintering porcelain on a ceramic abutment may change the microstructure and result in aging processes that influence the mechanical properties, internal strain, and the three-dimensional form of the abutment, thus causing a possible misfit between the abutment and the fixture. PURPOSE:The aim was to investi...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1708-8208.2007.00044.x

    authors: Kanno T,Milleding P,Wennerberg A

    更新日期:2007-09-01 00:00:00

  • The influence of bone type on the gene expression in normal bone and at the bone-implant interface: experiments in animal model.

    abstract:BACKGROUND:Studies on the biological processes in different bone types and the reaction of different bone types to biomaterials are often hindered because of the difficulties in sampling procedures and lack of sensitive techniques. PURPOSE:The purpose was to assess the suitability of quantitative polymerase chain reac...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00195.x

    authors: Omar O,Suska F,Lennerås M,Zoric N,Svensson S,Hall J,Emanuelsson L,Nannmark U,Thomsen P

    更新日期:2011-06-01 00:00:00

  • One-year prospective three-center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant.

    abstract:BACKGROUND:Oral implant treatment ad modum Brånemark has been used for decades in the rehabilitation of edentate and partially dentate patients. Posterior jaw regions frequently exhibit bone of poor texture, and it is often difficult to obtain primary stability. Thus, it may prove beneficial to deviate from the origina...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1708-8208.2003.tb00186.x

    authors: Friberg B,Jisander S,Widmark G,Lundgren A,Ivanoff CJ,Sennerby L,Thorén C

    更新日期:2003-01-01 00:00:00

  • Buccal bone thickness at dental implants in the maxillary anterior region with large bony defects at time of immediate implant placement: A 1-year cohort study.

    abstract:BACKGROUND:There is lack of studies regarding preservation and possible changes in BBT at dental implants. PURPOSE:To assess, on cone beam computer tomograms, the presence of bone at the time of tooth extraction in the maxillary esthetic region and the mean buccal bone thickness 1 month and 1 year after final restorat...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12701

    authors: Meijer HJA,Slagter KW,Vissink A,Raghoebar GM

    更新日期:2019-02-01 00:00:00

  • Bone and soft tissue outcomes, risk factors, and complications of implant-supported prostheses: 5-Years RCT with different abutment types and loading protocols.

    abstract:BACKGROUND:Data on risk factors and complications after long-term implant treatment is limited. The aims were to evaluate the role of various fixation modes and to analyze complications and risks that affect long-term use of implant-supported partial fixed dental prostheses. MATERIALS AND METHODS:Fifty partially edent...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12587

    authors: Göthberg C,Gröndahl K,Omar O,Thomsen P,Slotte C

    更新日期:2018-06-01 00:00:00

  • Maxillary Sinus Augmentation with a New Xenograft: A Randomized Controlled Clinical Trial.

    abstract:BACKGROUND:Insufficient residual alveolar bone height is a common deterrent in the placement of dental implants in the posterior maxilla. The use of autografts, xenografts, allografts and alloplasts or a combination between them has been demonstrated to be effective for increasing bone height and bone volume in the def...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12289

    authors: Calasans-Maia MD,Mourão CF,Alves AT,Sartoretto SC,de Uzeda MJ,Granjeiro JM

    更新日期:2015-10-01 00:00:00

  • Biomechanical measurements of calcium-incorporated oxidized implants in rabbit bone: effect of calcium surface chemistry of a novel implant.

    abstract:BACKGROUND:In oral implantology there has been a general trend away from machine-turned minimally rough and acid-etched and blasted implants toward intermediary roughened surfaces. Mechanical interlocking at micron resolution is claimed to be the dominant reason for the fixation of such implants in bone. However, clini...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2004.tb00032.x

    authors: Sul YT,Byon ES,Jeong Y

    更新日期:2004-01-01 00:00:00

  • Rehabilitation of edentulous mandibles by means of five TiUnite implants after one-stage surgery: a 1-year retrospective study of 90 patients.

    abstract:BACKGROUND:Recently, the present team reported the 1-year data of one-stage surgery and mainly early loading performed in edentulous mandibles using 750 turned Brånemark System implants in 152 patients. PURPOSE:The aim of the present investigation was to retrospectively evaluate the 1-year results of the same treatmen...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2007.00060.x

    authors: Friberg B,Jemt T

    更新日期:2008-03-01 00:00:00

  • Temporary implants for patients with low bone density of the upper maxilla: an alternative rehabilitation strategy.

    abstract:BACKGROUND:The use of removable provisional prosthesis after implant placement is undesirable for many patients. In addition, removable prostheses place unfavorable pressure over implants during the healing period. PURPOSE:The use of temporary implants enable greater stability and functionality of the prostheses. MAT...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00225.x

    authors: de Aguiar RC,Zabolotsky B,de Souza DC,Ferreira CF,Cardoso AC

    更新日期:2012-03-01 00:00:00

  • Influence of surface roughness of barrier walls on guided bone augmentation: experimental study in rabbits.

    abstract:BACKGROUND:By using the guided tissue regeneration concept it is possible to augment bone, beyond the skeletal envelope, provided certain biologic, surgical, and barrier-related demands are met. Among barrier-related factors of importance are the surface properties. PURPOSE:The aim of this study was to evaluate whethe...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.1999.tb00090.x

    authors: Lundgren AK,Lundgren D,Wennerberg A,Hämmerle CH,Nyman S

    更新日期:1999-01-01 00:00:00

  • The Effect of Hierarchical Micro/Nanotextured Titanium Implants on Osseointegration Immediately After Tooth Extraction in Beagle Dogs.

    abstract:BACKGROUND:Owing to simplify the operation and shorten the overall duration of treatment, immediate implantation earned much satisfactory from patients and dentists. The results of immediate implantation determined by osseointegration, we fabricated a micro/nanotextured titanium implants to improve osseointegration imm...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12464

    authors: Fu Q,Bellare A,Cui Y,Cheng B,Xu S,Kong L

    更新日期:2017-06-01 00:00:00

  • Clinical and radiographic peri-implant outcomes of short dental implants placed in posterior jaws of patients with treated generalized aggressive periodontitis: A 3-year follow-up study.

    abstract:BACKGROUND:Studies assessing clinical and radiographic peri-implant parameters around short dental implants (SDIs) in treated generalized aggressive periodontitis (GAgP) patients are scant. OBJECTIVES:This 3-year follow-up study aimed to compare the clinical peri-implant and radiographic bone status around SDIs placed...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12761

    authors: Akram Z,Vohra F,Sheikh SA,Albaijan R,Bukhari IA,Hussain M

    更新日期:2019-08-01 00:00:00

  • "Three-in-one" patient-specific surgical guides for simultaneous dental implants in fibula flap jaw reconstruction: A prospective case series.

    abstract:BACKGROUND:Conventional freehand immediate placement of dental implants is technically challenging in the jaw reconstructive surgery. Computer-aided surgery might be the best solution, however, there has not been any standard approach to ensure the accuracy and efficiency of simultaneous dental implants in fibula flap ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12954

    authors: Zhu WY,Su YX,Pow EHN,Yang WF,Qin L,Choi WS

    更新日期:2020-11-12 00:00:00

  • The profile of inflammatory cytokines in gingival crevicular fluid around healthy osseointegrated implants.

    abstract:OBJECTIVE:Regardless of gingival health and subgingival microbiology, production of cytokines within peri-implant tissues may be different from that of teeth. The objective of this study was to describe the peri-implant levels of pro-inflammatory cytokines and subgingival microbiology in clinically healthy sites. MATE...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2010.00299.x

    authors: Nowzari H,Phamduong S,Botero JE,Villacres MC,Rich SK

    更新日期:2012-08-01 00:00:00

  • Sinus Floor Augmentation Using Straumann® BoneCeramic™ and Bio-Oss® in a Split Mouth Design and Later Placement of Implants: A 5-Year Report from a Longitudinal Study.

    abstract:BACKGROUND:Straumann® BoneCeramic™ is a synthetic biphasic calcium phosphate (BCP) aimed for sinus floor augmentation. Long-term follow-up of implants placed in BCP after sinus augmentation is still missing. PURPOSE:The primary aim of the study was to compare survival rates and marginal bone loss of Straumann SLActive...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12374

    authors: Mordenfeld A,Lindgren C,Hallman M

    更新日期:2016-10-01 00:00:00

  • Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.

    abstract:BACKGROUND:Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES:The aims of this study were...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00095.x

    authors: Turkyilmaz I,Sennerby L,Yilmaz B,Bilecenoglu B,Ozbek EN

    更新日期:2009-03-01 00:00:00

  • Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.

    abstract:BACKGROUND:Few long-term follow-up studies on treatment concepts using computer numeric control-milled titanium frameworks have been conducted. OBJECTIVE:To evaluate the clinical and radiographic performance of implant-supported prostheses provided with computer numeric control-milled titanium frameworks in the edentu...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1708-8208.2004.tb00036.x

    authors: Ortorp A,Jemt T

    更新日期:2004-01-01 00:00:00

  • A 3-year retrospective study of Cresco frameworks: preload and complications.

    abstract:PURPOSE:The aim of this retrospective clinical study was to evaluate the clinical outcome of fixed implant-supported complete prostheses on Astra or Brånemark implants when using either conventional cast frameworks or frameworks produced according to the Cresco Ti Precision method (Cresco Ti Systems Sàrl., Lausanne, Sw...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2005.tb00064.x

    authors: Hjalmarsson L,Smedberg JI

    更新日期:2005-01-01 00:00:00

  • Accidental migration of a dental implant into the ethmoid sinus following a transalveolar sinus elevation procedure.

    abstract:BACKGROUND:Migration of a dental implant into the paranasal sinuses may be the result of sinus membrane perforation, loss of osseointegration, and lack of initial stability. The majority of displaced implants migrate into the maxillary sinus, which may cause sinusitis. PURPOSE:The purpose of this study is to report an...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12099

    authors: Bakhshalian N,Sim YC,Nowzari H,Cha HS,Ahn KM

    更新日期:2015-04-01 00:00:00

  • Experimental evaluation in rabbits of the effects of thread concavities in bone formation with different titanium implant surfaces.

    abstract:BACKGROUND:Differences in implant microtexture are important in conditioning the bone response around dental implants. PURPOSE:The aim of the present study was an evaluation of the bone response in machined (M), blasted with apatitic calcium phosphate (tricalcium phosphate/hydrossyapatite [HA] blend) particles (resorb...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12033

    authors: Scarano A,Degidi M,Perrotti V,Degidi D,Piattelli A,Iezzi G

    更新日期:2014-08-01 00:00:00

  • One-year outcome of implants strategically placed in the retrocanine bone triangle.

    abstract:BACKGROUND:Implant treatment in the partially edentulous maxilla is often challenging because of minimum bone volumes in distal direction. PURPOSE:The aim of this study was to evaluate, after 1 year of loading, the outcome of three-unit fixed partial dentures supported by two implants in the retrocanine triangle. MAT...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00170.x

    authors: Balleri P,Ferrari M,Veltri M

    更新日期:2010-12-01 00:00:00

  • Histological evaluations and inflammatory responses of different dental implant abutment materials: A human histology pilot study.

    abstract:BACKGROUND:Improvements of soft tissue to the abutment surface results in more stable peri-implant conditions, however, few human histological studies have compared soft tissue responses around different abutment materials. PURPOSE:To describe the peri-implant tissue around 3 abutment materials; titanium, zirconia, an...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12562

    authors: Sampatanukul T,Serichetaphongse P,Pimkhaokham A

    更新日期:2018-04-01 00:00:00

  • Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study.

    abstract:BACKGROUND:The original Brånemark protocol for dental implant treatment was based on submerged healing prior to loading. However, immediate loading has been reported possible with high success rates for various indications, provided that good bone quality and quantity are present. In many of these studies, machined-sur...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1708-8208.2003.tb00015.x

    authors: Glauser R,Lundgren AK,Gottlow J,Sennerby L,Portmann M,Ruhstaller P,Hämmerle CH

    更新日期:2003-01-01 00:00:00