The effects of cortical bone thickness and trabecular bone strength on noninvasive measures of the implant primary stability using synthetic bone models.

Abstract:

PURPOSE:This study investigated how the primary stability of a dental implant as measured by the insertion torque value (ITV), Periotest value (PTV), and implant stability quotient (ISQ) is affected by varying thicknesses of cortical bone and strengths of trabecular bone using synthetic bone models. MATERIALS AND METHODS:Four synthetic cortical shells (with thicknesses of 0, 1, 2, and 3 mm) were attached to four cellular rigid polyurethane foams (with elastic moduli of 137, 47.5, 23, and 12.4 MPa) and one open-cell rigid polyurethane foam which mimic the osteoporotic bone (with an elastic modulus 6.5 MPa), to represent the jawbones with various cortical bone thicknesses and strengths of trabecular bone. A total of 60 bone specimens accompanied with implants was examined by a torque meter, Osstell resonance frequency analyzer, and Periotest electronic device. All data were statistically analyzed by two-way analysis of variance. In addition, second-order nonlinear regression was utilized to assess the correlations of the primary implant stability with the four cortex thicknesses and five strengths of trabecular bone. RESULTS:ITV, ISQ, and PTV differed significantly (p < .05) and were strongly correlated with the thickness of cortical bone (R(2) > 0.9) and the elastic modulus of trabecular bone (R(2) = 0.74-0.99). CONCLUSIONS:The initial stability at the time of implant placement is influenced by both the cortical bone thickness and the strength of trabecular bone; however, these factors are mostly nonlinearly correlated with ITV, PTV, and ISQ. Using ITV and PTV seems more suitable for identifying the primary implant stability in osteoporotic bone with a thin cortex.

authors

Hsu JT,Fuh LJ,Tu MG,Li YF,Chen KT,Huang HL

doi

10.1111/j.1708-8208.2011.00349.x

subject

Has Abstract

pub_date

2013-04-01 00:00:00

pages

251-61

issue

2

eissn

1523-0899

issn

1708-8208

journal_volume

15

pub_type

杂志文章
  • Osseointegrated implant for single-tooth replacement: a retrospective multicenter study on routine use in private practice.

    abstract:BACKGROUND:Implant restorations first started with total edentulism. Later, the scientific community gave its approval for restorations in partial edentulism, and only recently some studies confirmed the validity of the treatment for single-tooth replacement. PURPOSE:The purpose of the study was to evaluate implant su...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1708-8208.2000.tb00006.x

    authors: Bianco G,Di Raimondo R,Luongo G,Paoleschi C,Piccoli P,Piccoli C,Rangert B

    更新日期:2000-01-01 00:00:00

  • Dental Implant Macro-Design Features Can Impact the Dynamics of Osseointegration.

    abstract:PURPOSE:The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. MATERIALS AND METHODS:Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva im...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12178

    authors: Vivan Cardoso M,Vandamme K,Chaudhari A,De Rycker J,Van Meerbeek B,Naert I,Duyck J

    更新日期:2015-08-01 00:00:00

  • The radiological evaluation of posterior superior alveolar artery topography by using computed tomography.

    abstract:BACKGROUND:Posterior superior alveolar artery (PSAA) is the most important limiting anatomic structure while lateral approach sinus surgeries. PSAA should be taken into consideration to avoid bleeding during preparation of bony window. PURPOSE:The aim of this article was to inform topography of PSAA and to evaluate me...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12794

    authors: Duruel O,Ataman-Duruel ET,Tözüm MD,Karabulut E,Tözüm TF

    更新日期:2019-08-01 00:00:00

  • Horizontal Ridge Augmentation using GBR with a Native Collagen Membrane and 1:1 Ratio of Particulated Xenograft and Autologous Bone: A 1-Year Prospective Clinical Study.

    abstract:AIM:To clinically and radiographically evaluate bone regeneration of severe horizontal bone defects. MATERIALS AND METHODS:This study was designed as a single cohort, prospective clinical trial. Partially or fully edentulous patients, having less then 4 mm of residual horizontal bone width were selected and consecutiv...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/cid.12429

    authors: Meloni SM,Jovanovic SA,Urban I,Canullo L,Pisano M,Tallarico M

    更新日期:2017-02-01 00:00:00

  • Patient satisfaction and dissatisfaction with mandibular two-implant overdentures using different attachment systems: 5-year outcomes.

    abstract:BACKGROUND:Different attachment systems for mandibular two-implant overdentures could influence levels of patient satisfaction. Positive consensus of the majority of patients being satisfied does not preclude the possibility of dissatisfaction for some. PURPOSE:To evaluate patient satisfaction and dissatisfaction befo...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1708-8208.2010.00306.x

    authors: Al-Zubeidi MI,Alsabeeha NH,Thomson WM,Payne AG

    更新日期:2012-10-01 00:00:00

  • Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.

    abstract:BACKGROUND:Few long-term follow-up studies on treatment concepts using computer numeric control-milled titanium frameworks have been conducted. OBJECTIVE:To evaluate the clinical and radiographic performance of implant-supported prostheses provided with computer numeric control-milled titanium frameworks in the edentu...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1708-8208.2004.tb00036.x

    authors: Ortorp A,Jemt T

    更新日期:2004-01-01 00:00:00

  • Elevated levels of 8-OHdG and PARK7/DJ-1 in peri-implantitis mucosa.

    abstract:BACKGROUND:Reactive oxygen species contribute to periodontal tissue homeostasis under control of anti-oxidative responses. Disruption in this balance induces severe inflammation and extended tissue degradation. PURPOSE:Aim of this study was to identify the expression levels of nuclear factor, erythroid 2 like 2 (NFE2L...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12619

    authors: Kasnak G,Firatli E,Könönen E,Olgac V,Zeidán-Chuliá F,Gursoy UK

    更新日期:2018-08-01 00:00:00

  • Immediate Loaded Implants in Split-Crest Procedure.

    abstract:BACKGROUND:The aim of this study was to assess survival rate of immediate loading implants placed after split-crest technique. METHODS:Thirty-six patients were enrolled in the study. They underwent placement of 93 dental implants in edentulous region after split-crest ridge expansion procedure. Implants followed an im...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12316

    authors: Crespi R,Bruschi GB,Gastaldi G,Capparé P,Gherlone EF

    更新日期:2015-10-01 00:00:00

  • Jaw Bone Samples From Bisphosphonate-Treated Patients: A Pilot Cohort Study.

    abstract:UNLABELLED:Osteonecrosis of the jaw (ONJ) is a severe complication of bisphosphonate treatment. PURPOSE:A detailed characterization of sampled peri-necrotic jawbone from bisphosphonate-treated patients was performed at tissue and cellular level (histological analyses and gene expression). MATERIALS AND METHODS:Alveol...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12307

    authors: Cardemil C,Thomsen P,Larsson Wexell C

    更新日期:2015-10-01 00:00:00

  • Evaluation of primary stability in modified implants: Analysis by resonance frequency and insertion torque.

    abstract:BACKGROUND:Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process. PURPOSE:The purpose of the present in vitro study was to evaluate the mechanical behavior of geometric changes in the apex region of dental implants. METHODS:Thirty-five cylindrical de...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12574

    authors: Sciasci P,Casalle N,Vaz LG

    更新日期:2018-06-01 00:00:00

  • Transcrestal Sinus Lift Using Platelet Concentrates in Association to Short Implant Placement: A Retrospective Study of Augmented Bone Height Remodeling.

    abstract:BACKGROUND:No evidence has been reported yet about dimensional changes in maxillary sinuses grafted with autologous platelet concentrate. PURPOSE:This study aimed to analyze the augmented height alterations around short implants (length ≤ 8.5 mm) placed after transcrestal sinus lift surgery in association with plasma ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12383

    authors: Anitua E,Flores J,Alkhraisat MH

    更新日期:2016-10-01 00:00:00

  • Prospective evaluation of morbidity in patients who underwent autogenous bone-graft harvesting from the mandibular symphysis and retromolar regions.

    abstract:BACKGROUND:Autogenous bone grafts are the most favorable and predictable types of bone graft due to their osteogenic, osteoinductive, and osteoconductive properties. The advantages of harvesting from mandibular bone are that it requires only local anesthesia, is less invasive, has less morbidity, and avoids harvesting ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12789

    authors: Pereira RS,Pavelski MD,Griza GL,Boos FBJD,Hochuli-Vieira E

    更新日期:2019-08-01 00:00:00

  • Infraposition of anterior maxillary implant-supported single-tooth restorations in adolescent and adult patients-A prospective follow-up study up to 6 years.

    abstract:BACKGROUND:In the maxillary incisor area infraposition of implant restorations can be an esthetic problem. PURPOSE:The aim was to analyze the prevalence of infraposition of single-tooth implant restorations in the anterior maxilla in adolescent and adult patients. MATERIAL AND METHODS:The study comprised of 31 patien...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12818

    authors: Nilsson A,Johansson LÅ,Stenport VF,Wennerberg A,Ekfeldt A

    更新日期:2019-10-01 00:00:00

  • Single-tooth replacement in the anterior maxilla by means of immediate implantation and early loading: clinical and aesthetic results at 5 years.

    abstract:BACKGROUND:The hypothesis of the present study was that the early loading of single implants-supported restorations, replacing single extracting teeth in the anterior region of the maxilla in case of fresh extraction sockets with residual hard and soft tissue preservation, could be a successful procedure. METHODS:Twen...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12111

    authors: Guarnieri R,Ceccherini A,Grande M

    更新日期:2015-04-01 00:00:00

  • One-year results of a prospective multicenter study on Brånemark System implants with a TiUnite surface.

    abstract:BACKGROUND:A moderately rough surface implant (TiUnite, Nobel Biocare AB, Göteborg, Sweden) was introduced in 2000. Laboratory studies and some clinical studies have demonstrated excellent bone response in the early healing phase. PURPOSE:The aim of this prospective multicenter study was to follow a large number of co...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/j.1708-8208.2005.tb00077.x

    authors: Friberg B,Dahlin C,Widmark G,Ostman PO,Billström C

    更新日期:2005-01-01 00:00:00

  • Accuracy of implant impressions with different impression coping types and shapes.

    abstract:BACKGROUND:Accurate recording of implant location is required so that definitive restorations are properly supported and do not place additional stresses on the implants. Movement of impression copings inside the impression material using an open-tray or close-tray impression technique during clinical and laboratory ph...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00241.x

    authors: Rashidan N,Alikhasi M,Samadizadeh S,Beyabanaki E,Kharazifard MJ

    更新日期:2012-04-01 00:00:00

  • Evaluation of L-PRF combined with deproteinized bovine bone mineral for early implant placement after maxillary sinus augmentation: A randomized clinical trial.

    abstract:PURPOSE:To investigate the effectiveness of adding leukocyte and platelet-rich fibrin (L-PRF) to deproteinized bovine bone mineral (DBBM) for early implant placement after maxillary sinus augmentation. MATERIALS AND METHODS:Twelve patients requiring two-stage bilateral maxillary sinus augmentation were enrolled to the...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12713

    authors: Pichotano EC,de Molon RS,de Souza RV,Austin RS,Marcantonio E,Zandim-Barcelos DL

    更新日期:2019-04-01 00:00:00

  • Biomedical Ti-Mo alloys with surface machined and modified by laser beam: biomechanical, histological, and histometric analysis in rabbits.

    abstract:PURPOSE:In vivo bone response was assessed by removal torque, hystological and histometrical analysis on a recently developed biomedical Ti-15Mo alloy, after surface modification by laser beam irradiation, installed in the tibia of rabbits. MATERIALS AND METHODS:A total of 32 wide cylindrical Ti-15Mo dental implants w...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00354.x

    authors: Oliveira NT,Guastaldi FP,Perrotti V,Hochuli-Vieira E,Guastaldi AC,Piattelli A,Iezzi G

    更新日期:2013-06-01 00:00:00

  • Sinus Floor Augmentation Using Straumann® BoneCeramic™ and Bio-Oss® in a Split Mouth Design and Later Placement of Implants: A 5-Year Report from a Longitudinal Study.

    abstract:BACKGROUND:Straumann® BoneCeramic™ is a synthetic biphasic calcium phosphate (BCP) aimed for sinus floor augmentation. Long-term follow-up of implants placed in BCP after sinus augmentation is still missing. PURPOSE:The primary aim of the study was to compare survival rates and marginal bone loss of Straumann SLActive...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12374

    authors: Mordenfeld A,Lindgren C,Hallman M

    更新日期:2016-10-01 00:00:00

  • Comparison of immediate-load mini dental implants and conventional-size dental implants to retain mandibular Kennedy class I removable partial dentures: A randomized clinical trial.

    abstract:BACKGROUND:Complications of distal extension mandibular removable partial dentures are: loss of retention, irritation, and so forth. Dental implants have been used to support distal extension removable partial dentures. However, many patients have limited bone support in which to place conventional-size dental implants...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12646

    authors: Threeburuth W,Aunmeungtong W,Khongkhunthian P

    更新日期:2018-10-01 00:00:00

  • In vitro measurements of precision of fit of implant-supported frameworks. A comparison between "virtual" and "physical" assessments of fit using two different techniques of measurements.

    abstract:BACKGROUND:Comparisons between different techniques measuring fit of implant-supported frameworks are few. PURPOSE:The purpose of this study was to compare data on precision of fit from two highly accurate measuring techniques and, also, to compare results using software programs for fit assessments considering both a...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00416.x

    authors: Jemt T,Hjalmarsson L

    更新日期:2012-05-01 00:00:00

  • The precision of fit of milled titanium implant frameworks (I-Bridge) in the edentulous jaw.

    abstract:BACKGROUND:New computer numeric controlled (CNC)-milled frameworks for implant-supported prostheses have been introduced. However, no data are available on the precision of fit of these new frameworks. PURPOSE:The purpose of this study is to evaluate the precision of fit of a new CNC-milled framework technique (I-Brid...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00131.x

    authors: Eliasson A,Wennerberg A,Johansson A,Ortorp A,Jemt T

    更新日期:2010-06-01 00:00:00

  • Influence of Micro Threads Alteration on Osseointegration and Primary Stability of Implants: An FEA and In Vivo Analysis in Rabbits.

    abstract:PURPOSE:To describe the early bone tissue response to implants with and without micro threads designed to the full length of an oxidized titanium implant. MATERIALS AND METHODS:A pair of two-dimensional finite element models was designed using a computer aided three-dimensional interactive application files of an impl...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12143

    authors: Chowdhary R,Halldin A,Jimbo R,Wennerberg A

    更新日期:2015-06-01 00:00:00

  • The influence of wound closure on graft stability: An in vitro comparison of different bone grafting techniques for the treatment of one-wall horizontal bone defects.

    abstract:OBJECTIVES:The aim of this preclinical study was to analyze and compare different grafting techniques with respect to volume stability after wound closure. MATERIALS AND METHODS:Four different grafting techniques were evaluated in vitro for volume stability in a one-wall horizontal defect configuration. Group 1: guide...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12728

    authors: Mertens C,Braun S,Krisam J,Hoffmann J

    更新日期:2019-04-01 00:00:00

  • Healing of extraction sockets filled with BoneCeramic® prior to implant placement: preliminary histological findings.

    abstract:BACKGROUND:Various grafting materials have been designed to minimize edentulous ridge volume loss following tooth extraction by encouraging new bone formation in healing sockets. BoneCeramic® is a composite of hydroxyapatite and bèta-tricalcium phosphate with pores of 100-500 microns. PURPOSES:The aim of this study wa...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00184.x

    authors: De Coster P,Browaeys H,De Bruyn H

    更新日期:2011-03-01 00:00:00

  • Nonsubmerged implants in the treatment of the edentulous lower jaw: a 5-year prospective longitudinal study of ITI hollow screws.

    abstract:BACKGROUND:Although most implant systems have been designed for a two-stage surgical technique, a one-stage surgical technique has always been advocated for the ITI Dental Implant System (Straumann AG, Waldenburg, Switzerland). A new generation of ITI implants was presented in 1988 and included a hollow cylinder, a hol...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2001.tb00125.x

    authors: Hellem S,Karlsson U,Almfeldt I,Brunell G,Hamp SE,Astrand P

    更新日期:2001-01-01 00:00:00

  • Biomarkers for Bisphosphonate-Related Osteonecrosis of the Jaw.

    abstract:PURPOSE:The aim of this study was to investigate a possible biomarker for bisphosphonate-related osteonecrosis of the jaw (BRONJ) in an animal model. MATERIALS AND METHODS:Forty-eight Sprague-Dawley rats were randomly divided into the bisphosphonate group (n = 36), who were injected once a week with zoledronic acid, a...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12297

    authors: Kim JW,Cha IH,Kim SJ,Kim MR

    更新日期:2016-04-01 00:00:00

  • Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading.

    abstract:BACKGROUND:Rigorous efforts to reduce the recurrence of abutment screw loosening in single-tooth implant restorations have recently been made. However, the behavior of the implant/abutment joint components with respect to critical bending force is still unclear. PURPOSE:This study investigated the effect of different ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2004.tb00216.x

    authors: Khraisat A,Abu-Hammad O,Dar-Odeh N,Al-Kayed AM

    更新日期:2004-01-01 00:00:00

  • Microbiology and cytokine levels around healthy dental implants and teeth.

    abstract:BACKGROUND:Elicitation of the relationship of periodontopathogens and pro-inflammatory cytokines to bone resorption and formation is significant to a growing body of research known as osteoimmunology. It is essential that clinically healthy peri-implant and periodontal sites are studied to contribute comparison data fo...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2007.00076.x

    authors: Nowzari H,Botero JE,DeGiacomo M,Villacres MC,Rich SK

    更新日期:2008-09-01 00:00:00

  • The Risk of Prion Infection through Bovine Grafting Materials.

    abstract:BACKGROUND:Bovine-derived grafting materials are frequently used in a variety of bone augmentation techniques. The aim of this paper is to assess the unique safety issue of bovine-derived grafting materials that is rarely addressed in dental literature: risk of bovine spongiform encephalopathy (BSE). METHODS:The valid...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12391

    authors: Kim Y,Rodriguez AE,Nowzari H

    更新日期:2016-12-01 00:00:00