Abstract:
PURPOSE:Upper eyelid sulcus deepening has recently been reported as an adverse effect of prostaglandin (PG) eye drop use. However, no data are available regarding the frequency of upper eyelid sulcus deepening caused by different types of PG eye drops. We used 5 types of PG eye drops in Japanese subjects and examined the frequency of appearance of upper eyelid sulcus deepening in these subjects. PATIENTS AND METHODS:The study included 250 patients (250 eyes) diagnosed with primary open-angle glaucoma or ocular hypertension. Five healthy patients were included as controls. One eye of each patient was treated with one of the following PG eye drops for >3 months: latanoprost, travoprost, tafluprost, bimatoprost, and isopropyl unoprostone. A single-lens reflex camera was used to photograph the open eyelids. Three ophthalmologists independently judged the appearance of the deepened upper eyelid sulcus in the photographs of the 250 patients and 5 controls by comparing the right and left eyes. A subjective self-reported symptom questionnaire was also administered. RESULTS:Upper eyelid sulcus deepening was objectively (photograph) and subjectively (questionnaire) noted in 24.0% and 12.0%, 50.0% and 24.0%, 18.0% and 10.0%, 60.0% and 40.0%, and 8.0% and 10.0% of the patients in the latanoprost, travoprost, tafluprost, bimatoprost, and unoprostone groups, respectively. It occurred more frequently (objectively and subjectively) in the bimatoprost group than in the latanoprost, the tafluprost, and the unoprostone groups (P<0.001). CONCLUSION:Upper eyelid sulcus deepening frequently occurred with bimatoprost usage, and this effect should be sufficiently elucidated before starting bimatoprost treatment.
journal_name
J Glaucomajournal_title
Journal of glaucomaauthors
Inoue K,Shiokawa M,Wakakura M,Tomita Gdoi
10.1097/IJG.0b013e31824d8d7csubject
Has Abstractpub_date
2013-10-01 00:00:00pages
626-31issue
8eissn
1057-0829issn
1536-481Xjournal_volume
22pub_type
杂志文章abstract:PURPOSE:Our purpose was to evaluate the clinical outcomes of the Ex-PRESS miniature glaucoma device placed under a partial-thickness scleral flap as a single procedure or combined with phacoemulsification cataract surgery. METHODS:This was a comparative consecutive case series of 345 eyes: 231 eyes treated with Ex-PRE...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31818fb44e
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:To investigate the efficacy of currently available correction factors in correcting intraocular pressure (IOP) measurements for the errors induced by the normal variations in corneal structural characteristics. MATERIALS AND METHODS:Central corneal thickness (CCT) and corneal radius of curvature were measured ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000176940.81799.33
更新日期:2005-10-01 00:00:00
abstract:PURPOSE:To investigate changes in scanning laser polarimetry with variable corneal compensation (GDx-VCC) parameters caused by posterior capsular opacification (PCO). METHODS:In this comparative case-control series, 20 eyes due to undergo YAG laser capsulotomy for PCO were recruited. GDx-VCC was performed before and a...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000243469.05719.0d
更新日期:2007-01-01 00:00:00
abstract:PURPOSE:To evaluate the usefulness of day-long sequential office measurements of intraocular pressure (IOP) to make therapeutic decisions in patients with progressive glaucomatous damage despite apparently 'controlled' IOP. METHODS:We reviewed the records of 93 consecutive glaucoma patients (185 eyes) who underwent se...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000159125.34241.79
更新日期:2005-06-01 00:00:00
abstract:PURPOSE:To assess the relative afferent pupillary defect (RAPD) by swinging flashlight as a potentially useful screening test for glaucomatous optic neuropathy. METHODS:One hundred seven subjects prospectively recruited from a mixed population of glaucomatous and nonglaucomatous patients were examined for a RAPD by 1 ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31826a9742
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:This study aimed to investigate (1) the prevalence of nonadherence with eye drop treatment; (2) selected correlates of nonadherence at the patient and health-care organization level; and (3) the diagnostic value of the ophthalmologists' ratings, using patients' self-reports as standard. METHODS:This cross-sect...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0b013e3181f7b10e
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:The purpose of this study was to determine the proportion of patients in the US population who are receiving long-term intraocular pressure (IOP)-lowering medication, but, deny having a diagnosis of glaucoma or elevated IOP. MATERIALS AND METHODS:The National Health and Nutrition Examination Survey (NHANES) is...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001035
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:To report the use of slit-lamp-adapted optical coherence tomography (SL-OCT) in imaging 2 patients with Descemet membrane detachment following anterior chamber reformation after trabeculectomy. METHODS:Two patients, with leaking and overfiltering blebs, respectively, developed Descemet detachments after reform...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31819c469e
更新日期:2009-12-01 00:00:00
abstract:OBJECTIVES:This study was conducted to evaluate the effect of long-term intraocular pressure reduction with timolol on the incidence of glaucomatous visual field defects and optic nerve cupping in individuals with ocular hypertension and to compare this incidence with that of a similar group on no treatment. ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract:PURPOSE:To evaluate the safety and efficacy of trabeculectomies performed by ophthalmology residents at a metropolitan county hospital, under the supervision of attending physicians. METHODS:A retrospective analysis of resident-performed trabeculectomies at the San Francisco General Hospital from the period of 1994 to...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000243473.59084.dd
更新日期:2007-01-01 00:00:00
abstract::The most effective way to control glaucoma is by lowering intraocular pressure (IOP) in order to prevent the progression of the disease. Glaucoma drainage devices (GDDs) are surgical option reserved for refractory cases and have been designed to address known complications of conventional filtering surgery. They are, ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001417
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. METHODS:A retrospective study of 16 patients (17 eyes) who underwent tube...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1999-10-01 00:00:00
abstract:PURPOSE:Lasers have been used to treat dysfunctional blebs, but the laser remodeling of blebs that dissect into the palpebral fissure has not been reported. We describe the unique use of krypton green laser to treat dissected blebs and discuss treatment outcomes. PATIENTS AND METHODS:Retrospective review of consecutiv...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200604000-00013
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:We aimed to evaluate the ability of new psychophysical discrimination tests, based on readily available hardware, to probe motion, achromatic, and chromatic contrast sensitivity, across the natural history of glaucoma. We assessed the sensitivity of these tests to detect functional damage at ocular hypertension...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000226
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:We measured changes in the corneal morphology and intraocular pressure (IOP) before and after the use of contact lens sensor (CLS). Then, we investigated whether the ocular dimensional change affected the measured IOP value with CLS. MATERIAL AND METHODS:In this prospective study, we examined 112 eyes of glauc...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001318
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:To evaluate morphological features of filtering blebs after trabeculectomy with limbus-based versus fornix-based conjunctival flaps (LBCF and FBCF, respectively) using in vivo confocal microscopy (IVCM) and ultrasound biomicroscopy (UBM). PATIENTS AND METHODS:Seventy-five eyes of 62 patients with glaucoma were...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182120a08
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:To determine whether a structure-function model developed for normal age-related losses of retinal ganglion cells also models the retinal ganglion cell losses in glaucomatous optic neuropathy. METHODS:The model to relate age-related loss of retinal nerve fiber layer thickness and reduced sensitivity for standa...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31820bcfbe
更新日期:2012-02-01 00:00:00
abstract:PRCIS:Use of toric intraocular lenses is a reasonable option for better visual outcomes when a combined minimally invasive glaucoma surgery (MIGS) and cataract surgery is performed in eyes with corneal astigmatism. PURPOSE:To assess the efficacy of toric intraocular lenses (IOLs) in combined cataract and MIGS, visual ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001705
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:To investigate risk factors associated with glaucomatous progression in pseudoexfoliation glaucoma (PXG) patients. PATIENTS AND METHODS:A retrospective observational study with a total of 48 PXG patients and age, sex, and visual field (VF) test mean deviation-matched 48 primary open-angle glaucoma (POAG) patie...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0000000000000791
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:The aim of this study was to compare the peripapillary vessel density between eyes with pseudoexfoliation glaucoma (PXG) and eyes with primary open-angle glaucoma (POAG). METHODS:Peripapillary vessel density in the radial peripapillary capillaries was assessed using optical coherence tomography angiography, an...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001062
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:The aim of the study was to investigate whether floppy eyelid syndrome (FES) could be an indicator of glaucoma in patients with obstructive sleep apnea (OSA). MATERIALS AND METHODS:A total of 152 patients were included: 75 patients with OSA and without FES; 52 patients with OSA and FES; and 25 non-OSA patients...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31829da19f
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:To assess the prevalence of optic disc hemorrhage in Asian patients with established glaucoma using a recently described, highly sensitive detection method. MATERIALS AND METHODS:Patients entering a trial of glaucoma filtering surgery in Southeast Asia (The Singapore 5FU Study) were assessed for the presence o...
journal_title:Journal of glaucoma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00061198-200306000-00008
更新日期:2003-06-01 00:00:00
abstract:PURPOSE:To develop a descriptive system for a glaucoma-specific preference-based health-related quality of life (HRQoL) instrument: the Health Utility for Glaucoma (HUG-5). METHODS:The descriptive system was developed in 2 stages: item identification and item selection. A systematic literature review of HRQoL assessme...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000984
更新日期:2018-07-01 00:00:00
abstract:OBJECTIVE:Pachymetry plays a crucial role in the diagnosis and management of glaucoma and corneal diseases. There have been several outbreaks of epidemic ocular infections in ophthalmology clinics worldwide with reports of viral, parasitic, and prion disease. Contact pachymetry is a possible vehicle of transmission due...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001525
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:To evaluate three new approaches for staging severity of glaucomatous visual field defects using frequency doubling technology. PATIENTS AND METHODS:One hundred and four patients with either ocular hypertension or chronic glaucoma were tested with both standard automated perimetry (SAP, 30-2 Humphrey threshold...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200310000-00004
更新日期:2003-10-01 00:00:00
abstract:PURPOSE:To find the dropout rate and identify the clinical characteristics of patients who drop out in the first year of follow-up from a glaucoma clinic. DESIGN:Descriptive hospital-based study at a tertiary hospital eye department. METHODS:Clinical characteristics of consecutive patients newly diagnosed with glauco...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31815768b3
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:The purpose of this study is to assess the relationship between serum glucose levels and intraocular pressure (IOP) both in subjects with impaired fasting glucose (IFG) as well as in subjects with diabetes mellitus (DM). MATERIALS AND METHODS:Data of a cross-sectional sample of 18,406 subjects who underwent ro...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000700
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:To examine the reproducibility of the new digital Goldmann applanation tonometer AT 900D (DGT) for measuring intraocular pressure and to compare its readings with those provided by the conventional analog Goldmann tonometer (AGT). METHODS:In 3 different sessions (S1, S2, and S3), 3 intraocular pressure measure...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31820bd1e9
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:To compare central corneal thickness between eyes with congenital glaucoma and normal controls and to correlate this parameter with corneal diameter and axial length. METHODS:Eyes of consecutive children with congenital glaucoma with previous glaucoma surgery and eyes of children with inadequacy of lacrimal dr...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200406000-00002
更新日期:2004-06-01 00:00:00
abstract::Glaucoma is a progressive optic neuropathy that is the leading cause of irreversible blindness in the world. Although methods to lower intraocular pressure are the mainstay of glaucoma therapy, there are currently no available treatment modalities targeted at neuroprotection. Erythropoietin is a hematopoietic cytokine...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0b013e318156a556
更新日期:2007-09-01 00:00:00