Abstract:
PURPOSE:To compare the rates of retinal nerve fiber layer (RNFL) thickness loss using optical coherence tomography (OCT) in progressing versus nonprogressing eyes using 4 methods to define functional progression. METHODS:Normal and glaucomatous eyes with ≥3 years of follow up were prospectively enrolled. Standard automated perimetry (Swedish Interactive Threshold Algorithm Standard 24-2) and OCT (Stratus OCT, Carl Zeiss Meditec, Dublin, CA) imaging were performed every 6 months in glaucomatous eyes. OCT imaging was performed annually in normal eyes. Functional progression was determined using early manifest glaucoma trial criterion, visual field index (VFI), Progressor software, and the 3-omitting method. RESULTS:Seventy-six eyes (46 glaucoma and 30 normal) of 38 patients were enrolled with a mean follow-up of 43.9 ± 5.02 months (range: 36 to 48 mo). Eleven eyes progressed using Progressor criterion, 5 eyes using VFI, 2 eyes using the 3-omitting method, and 2 eyes using Early Manifest Glaucoma Trial criterion. The annual rate of average RNFL loss (μm/y) was significantly greater (P<0.05) in progressing versus nonprogressing eyes using Progressor (-1.0 ± 1.3 vs. 0.02 ± 1.6), VFI (-2.1 ± 1.1 vs. -0.002 ± 1.4), and the 3-omitting method (-2.2 ± 0.2 vs. -0.1 ± 1.5). Mean rate (μm/y) of average and superior RNFL thickness change was similar (P>0.05) in nonprogressing glaucomatous eyes compared with normal eyes. Using linear mixed-effect models, mean (P<0.001) and peak (P=0.01) intraocular pressure were significantly associated with rate of average RNFL atrophy in glaucomatous eyes. CONCLUSIONS:Despite differences in criteria used to judge functional progression, eyes with standard automated perimetry progression have significantly greater rates of RNFL loss measured using OCT compared with nonprogressing eyes.
journal_name
J Glaucomajournal_title
Journal of glaucomaauthors
Grewal DS,Sehi M,Paauw JD,Greenfield DS,Advanced Imaging in Glaucoma Study Group.doi
10.1097/IJG.0b013e3182071cc7subject
Has Abstractpub_date
2012-04-01 00:00:00pages
214-20issue
4eissn
1057-0829issn
1536-481Xjournal_volume
21pub_type
杂志文章abstract:PRECIS:Silica nanoparticles (SiNPs), which are potential drug carriers for glaucoma treatment, may induce mild dose-dependent cytotoxicity but not so severe as to compromise a mammalian target of rapamycin (mTOR) pathway in immortalized trabecular meshwork (TM) cells. PURPOSE:Nanoparticle-based ophthalmic drug deliver...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001709
更新日期:2021-02-01 00:00:00
abstract:PURPOSE:To evaluate whether postural changes of intraocular pressure (IOP) are associated with visual field damage by comparing both eyes of patients with previously untreated normal-tension glaucoma (NTG). PATIENTS AND METHODS:Forty eyes of 20 patients newly diagnosed as bilateral NTG were studied. IOP was measured i...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181a98f30
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:Subconjunctival mitomycin C has been used in glaucoma filtration surgery with success. A prospective, randomized, masked, placebo-controlled study was performed to evaluate whether single transconjunctival mitomycin C applied either preoperatively or postoperatively would enhance the success of filtration surge...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1997-10-01 00:00:00
abstract::We report 2 bilateral cases that presented as primary ocular hypertension and primary angle-closure glaucoma, respectively; however, they were subsequently discovered to be harboring secretory pituitary tumors. After transsphenoidal tumor resection, intraocular pressures (IOPs) in all 4 eyes returned to normal levels....
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31829521f2
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:We assessed vision-related quality of life (VR-QOL) in glaucoma patients and examined the relationship between VR-QOL and indices of visual function and subjective symptoms. PATIENTS AND METHODS:Four hundred seventy-two glaucoma patients completed a questionnaire concerning VR-QOL and subjective symptoms of gl...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0000000000000221
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:To evaluate morphological features of filtering blebs after trabeculectomy with limbus-based versus fornix-based conjunctival flaps (LBCF and FBCF, respectively) using in vivo confocal microscopy (IVCM) and ultrasound biomicroscopy (UBM). PATIENTS AND METHODS:Seventy-five eyes of 62 patients with glaucoma were...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182120a08
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:To report on the prevalence of pseudoexfoliation (PEX) and its association with ophthalmic characteristics and systemic diseases in a well-defined population. METHODS:The Thessaloniki Eye study is a cross-sectional population-based study of chronic eye diseases in Thessaloniki, Greece. Participants with PEX we...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181d9d8bd
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:To compare central corneal thickness between eyes with congenital glaucoma and normal controls and to correlate this parameter with corneal diameter and axial length. METHODS:Eyes of consecutive children with congenital glaucoma with previous glaucoma surgery and eyes of children with inadequacy of lacrimal dr...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200406000-00002
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). METHODS:Four hundred twenty-two eyes (78 healthy, 210 suspects, 134 glaucomatous) of 250 patients were recruited from the...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31822af27a
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:Pseudoexfoliation (PEX) syndrome, an age-related, systemic, elastic microfibrillopathy, is characterized by fibrillar-granular deposits in the anterior segment of the eye. Although not representing a true amyloidosis, PEX syndrome shares some features with amyloid disorders, such as Alzheimer disease. It has be...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181ca76c4
更新日期:2010-10-01 00:00:00
abstract:PURPOSE:To study the additive effect of latanoprost 0.005% in patients who have uncontrolled intraocular pressure (IOP) using timolol 0.5% and dorzolamide 2%. METHODS:Fifty-two consecutive patients with open-angle glaucoma who were using timolol and dorzolamide and were considered to have IOP above their defined targe...
journal_title:Journal of glaucoma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00061198-200004000-00010
更新日期:2000-04-01 00:00:00
abstract::We report a case of acute angle closure with significantly elevated intraocular pressure 9 hours after implantation of a phakic intraocular lens for high myopia. ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001533
更新日期:2020-07-01 00:00:00
abstract:PURPOSE:To determine if a new, normative, race-specific database enhances the ability of confocal scanning laser ophthalmoscopy to differentiate normal from glaucomatous eyes. METHODS:One eye of eligible normal and glaucoma patients was enrolled. All subjects underwent a complete ophthalmologic examination, standard a...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000212289.00917.a8
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:To evaluate the efficacy of transconjunctival revision (TCR) with mitomycin-C (MMC) following failed trabeculectomy. MATERIALS AND METHODS:The medical records of 27 patients (27 eyes) who underwent TCR with subconjunctival injection of MMC by a single surgeon between September 2001 and August 2013 were retrosp...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000408
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:To determine whether the multifocal visual evoked potential (mfVEP) technique can detect early functional damage in ocular hypertensive (OHT) and glaucoma suspect (GS) patients with normal standard achromatic automated perimetry (SAP) results. PATIENTS AND METHODS:Twenty-five GS patients (25 eyes), 25 patients...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000212237.26466.0e
更新日期:2006-08-01 00:00:00
abstract:PURPOSE:To report the efficacy and safety of inferior 180 degrees goniosynechialysis followed by diode laser peripheral iridoplasty in the treatment of chronic angle-closure glaucoma with total synechial angle closure. METHODS:Five patients with chronic angle-closure glaucoma and total synechial angle closure whose in...
journal_title:Journal of glaucoma
pub_type: 临床试验,杂志文章
doi:10.1097/00061198-200010000-00007
更新日期:2000-10-01 00:00:00
abstract:OBJECTIVE AND METHOD:A randomized, double-blind, parallel-group study compared the effectiveness and tolerability of three treatments for glaucoma: 2% carteolol/2% pilocarpine fixed-ratio combination (CBS 341A) twice a day, versus a 0.5% timolol/2% pilocarpine fixed combination twice a day versus 2% carteolol twice a d...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1995-08-01 00:00:00
abstract:PURPOSE:To evaluate tonometric outcomes of patients with primary angle closure glaucoma (PACG) who have undergone trabeculectomy with mitomycin C (MMC) with and without concurrent phacoemulsification and to identify risk factors for postoperative failure. PATIENTS AND METHODS:Retrospective cohort study of 44 eyes of 3...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000493
更新日期:2016-09-01 00:00:00
abstract:PURPOSE:To evaluate the reproducibility of retinal nerve fiber layer (RNFL) thickness measurements in normal and glaucoma patients using the spectral optical coherence tomography (OCT)/scanning laser ophthalmosope (SLO). METHODS:One experienced operator measured peripapillary RNFL thickness 3 times in succession in 98...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181ca7cbe
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:To describe a new and simple technique of glaucoma tube extension that carries several advantages over previously described techniques. PATIENTS AND METHODS:A retrospective noncomparative case series of 3 patients (1 adult and 2 pediatric cases) with glaucoma tube retraction managed by the "tube-in-tube" techn...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000567
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:To evaluate rates of adherence to free follow-up eye exam appointments among participants in the Philadelphia Glaucoma Detection and Treatment Project. PATIENTS AND METHODS:Ophthalmologists and testing equipment were brought directly to participants at risk for glaucoma at 43 community sites in Philadelphia. T...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0000000000000716
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:The purpose of the study was to evaluate the tolerability and functionality of a wireless ocular telemetry sensor in African American patients with glaucoma. MATERIALS AND METHODS:In this prospective, observational cohort study, 20 African American patients with primary open angle glaucoma (POAG) were evaluate...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001141
更新日期:2019-02-01 00:00:00
abstract::Many of these techniques have been adapted to investigate hemodynamic alterations, not only in glaucoma, but in diverse disorders such as diabetic retinopathy, macular degeneration, retinal dystrophies, and nonglaucomatous optic neuropathies. However, each of these techniques has limitations and there is not a single ...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/00061198-200110001-00022
更新日期:2001-10-01 00:00:00
abstract:PURPOSE:To evaluate three new approaches for staging severity of glaucomatous visual field defects using frequency doubling technology. PATIENTS AND METHODS:One hundred and four patients with either ocular hypertension or chronic glaucoma were tested with both standard automated perimetry (SAP, 30-2 Humphrey threshold...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200310000-00004
更新日期:2003-10-01 00:00:00
abstract:PURPOSE:Microvasculature dropout (MvD) is a novel finding seen in optical coherence tomography angiography (OCTA), which is characterized by a localized dehiscence of the choriocapillaris in the parapapillary atrophy area. Disc hemorrhage (DH) is an important factor often associated with the development and especially ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001688
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:This study investigated the effects of posterior sub-Tenon capsule (PST) injection of triamcinolone acetonide (TA) on intraocular pressure (IOP) in the human eye. METHODS:The study included 115 patients who received PST injections of 40-mg TA to treat macular edema with diabetic retinopathy (n=57), branch reti...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31802d696f
更新日期:2007-03-01 00:00:00
abstract:PRECIS:Citicoline eyedrops in patients with progressing glaucoma. PURPOSE:This study aimed to test whether the additional therapy with citicoline eyedrops to intraocular pressure (IOP)-lowering treatment could slow glaucoma progression in patients with worsening of damage and IOP 18 mm Hg or less. DESIGN:This was a r...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1097/IJG.0000000000001565
更新日期:2020-07-01 00:00:00
abstract:PURPOSE:To evaluate aqueous levels of vascular endothelial growth factor (VEGF) and endothelin-1 (ET-1) in patients with branch retinal vein occlusion (BRVO) with and without normal tension glaucoma (NTG), and to assess the therapeutic efficacy of intravitreal bevacizumab (IVB) in these patients. METHODS:Sixteen eyes ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182312047
更新日期:2013-02-01 00:00:00
abstract:PURPOSE:To compare near and distance stereoacuity between patients with primary open-angle glaucoma (POAG) and a control group, and to analyze the associations between stereoacuity and POAG severity. METHODS:This cross-sectional study compared near and distance stereoacuity between the POAG and control groups. The dat...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000963
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:The goal of this study was to identify the early postoperative intraocular pressure (IOP) that predicts low pressure control after a trabeculectomy with mitomycin C. MATERIALS AND METHODS:This study retrospectively analyzed the medical records of the initial trabeculectomy with mitomycin C in patients with pri...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e318285fd7d