Optimizing the perception of soft speech and speech in noise with the Advanced Bionics cochlear implant system.

Abstract:

OBJECTIVE:This study aimed to provide guidelines to optimize perception of soft speech and speech in noise for Advanced Bionics cochlear implant (CI) users. DESIGN:Three programs differing in T-levels were created for ten subjects. Using the T-level setting that provided the lowest FM-tone, sound-field threshold levels for each subject, three additional programs were created with input dynamic range (IDR) settings of 50, 65 and 80 dB. STUDY SAMPLE:Subjects were postlinguistically deaf adults implanted with either the Clarion CII or 90K CI devices. RESULTS:Sound-field threshold levels were lowest with T-levels set higher than 10% of M-levels and with the two widest IDRs. Group data revealed significantly higher scores for CNC words presented at a soft level with an IDR of 80 dB and 65 dB compared to 50 dB. Although no significant group differences were seen between the three IDRs for sentences in noise, significant individual differences were present. CONCLUSIONS:Setting Ts higher than the manufacturer's recommendation of 10% of M-levels and providing IDR options can improve overall speech perception; however, for some users, higher Ts and wider IDRs may not be appropriate. Based on the results of the study, clinical programming recommendations are provided.

journal_name

Int J Audiol

authors

Holden LK,Reeder RM,Firszt JB,Finley CC

doi

10.3109/14992027.2010.533200

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

255-69

issue

4

eissn

1499-2027

issn

1708-8186

journal_volume

50

pub_type

杂志文章
  • College students' personal listening device usage and knowledge.

    abstract:OBJECTIVE:To determine the usage and knowledge of safe limits on personal listening devices (PLD) among college students. DESIGN:First, information on health history was collected. Second, microphone in real ear techniques determined eardrum to free-field correction factors. Third, hearing levels were evaluated and in...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2014.986691

    authors: Hutchinson Marron K,Marchiondo K,Stephenson S,Wagner S,Cramer I,Wharton T,Hughes M,Sproat B,Alessio H

    更新日期:2015-06-01 00:00:00

  • Assessment of the efferent auditory system in children with suspected auditory processing disorder: the Middle ear muscle reflex and contralateral inhibition of OAEs.

    abstract:OBJECTIVE:To determine whether children aged 7 to 12 years with listening difficulties show objective evidence for efferent auditory function based on measurements of medial olivo-cochlear and middle ear muscle reflexes. DESIGN:Click-evoked otoacoustic emissions recorded with and without contralateral broadband noise ...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2018.1523578

    authors: Smart JL,Kuruvilla-Mathew A,Kelly AS,Purdy SC

    更新日期:2019-01-01 00:00:00

  • Thresholds for vestibular-evoked myogenic potentials (VEMPs) produced by impulsive transmastoid acceleration.

    abstract:OBJECTIVE:To evaluate methods for estimating thresholds of vestibular evoked myogenic potentials (VEMPs) and ocular VEMPs (OVEMPs) produced by impulsive transmastoid acceleration (ITA). DESIGN:VEMPs and OVEMPs were obtained simultaneously from subjects in supine posture with both head and eyes elevated. Thresholds to ...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2013.853134

    authors: Paillard AC,Kluk K,Todd NP

    更新日期:2014-02-01 00:00:00

  • Music mixing preferences of cochlear implant recipients: a pilot study.

    abstract:OBJECTIVE:Music perception and appraisal are generally poor in cochlear implant recipients. Simple musical structures, lyrics that are easy to follow, and clear rhythm/beat have been reported among the top factors to enhance music enjoyment. The present study investigated the preference for modified relative instrument...

    journal_title:International journal of audiology

    pub_type: 临床试验,杂志文章

    doi:10.3109/14992027.2013.873955

    authors: Buyens W,van Dijk B,Moonen M,Wouters J

    更新日期:2014-05-01 00:00:00

  • Cochrane corner: platinum-induced hearing loss after treatment for childhood cancer.

    abstract::This Cochrane Corner features the review entitled "Platinum-induced hearing loss after treatment for childhood cancer" published in 2016. In their review, van As et al. identified 13 cohort studies including 2837 participants with a hearing test after treatment with a platinum-based therapy for different types of chil...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2018.1539808

    authors: Brennan-Jones CG,McMahen C,Van Dalen EC

    更新日期:2019-04-01 00:00:00

  • Linear and nonlinear hearing aid fittings--1. Patterns of benefit.

    abstract::We evaluated the benefits of fast-acting WDRC, slow-acting AVC, and linear reference fittings for speech intelligibility and reported disability, in a within-subject within-device masked crossover design on 50 listeners with SNHL. Five hearing aid fittings were implemented having two compression channels and seven fre...

    journal_title:International journal of audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1080/14992020500429518

    authors: Gatehouse S,Naylor G,Elberling C

    更新日期:2006-03-01 00:00:00

  • Azimuthal auditory localization of gunshots in a realistic field environment: effects of open-ear versus hearing protection-enhancement devices (HPEDs), military vehicle noise, and hearing impairment.

    abstract:OBJECTIVE:A controlled field experiment was conducted to evaluate localization of suprathreshold gunshot reports (from blank cartridges) with four hearing protection-enhancement devices (HPEDs) in comparison to the open ear with ambient outdoor noise and in 82 dBA diesel military heavy truck noise. DESIGN:Five measure...

    journal_title:International journal of audiology

    pub_type: 临床试验,杂志文章

    doi:10.3109/14992027.2011.631591

    authors: Talcott KA,Casali JG,Keady JP,Killion MC

    更新日期:2012-02-01 00:00:00

  • Development of a new method for deriving initial fittings for hearing aids with multi-channel compression: CAMEQ2-HF.

    abstract::Moore et al (1999b) described a procedure, CAMEQ, for the initial fitting of multi-channel compression hearing aids. The procedure was derived using a model of loudness perception for impaired hearing. We describe here the development of a new fitting method, CAMEQ2-HF, which differs from CAMEQ in the following ways: ...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992020903296746

    authors: Moore BC,Glasberg BR,Stone MA

    更新日期:2010-03-01 00:00:00

  • Examination of differences between successful and unsuccessful elderly hearing aid candidates matched for age, hearing loss and gender.

    abstract::This study examined group differences on a variety of measures for three groups of elderly hearing aid candidates matched for gender, age and hearing loss. These three groups were: (1) 26 candidates who declined amplification (non-adherents); (2) 24 individuals who purchased hearing aids, but subsequently returned the...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992020309080053

    authors: Humes LE,Wilson DL,Humes AC

    更新日期:2003-10-01 00:00:00

  • The effects of training format on earplug performance.

    abstract::This experiment investigated the effect of small-group versus individual hearing loss prevention (HLP) training on the attenuation performance of passive insert-type hearing protection devices (HPDs). A subject-fit (SF) methodology, which gave naive listeners access only to the instructions printed on the HPD product ...

    journal_title:International journal of audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1080/14992020701438805

    authors: Joseph A,Punch J,Stephenson M,Paneth N,Wolfe E,Murphy W

    更新日期:2007-10-01 00:00:00

  • Permanent t-tube insertion in two patients with Hurler's syndrome.

    abstract::Hearing loss in mucopolysaccharidosis is usually both conductive and sensorineural. The conductive component is attributable to serous otitis media secondary to dysfunction of the eustachian tube and chronic thickening of the mucosa of the middle ear. The conductive component may persist after myringotomy and insertio...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020600975287

    authors: Oghan F,Harputluoglu U,Guclu E,Guvey A,Turan N,Ozturk O

    更新日期:2007-02-01 00:00:00

  • Prevalence of hearing loss and associated factors in subjects with normal otoscopy: a national cross-sectional study.

    abstract:OBJECTIVE:To report the prevalence of hearing loss (HL) and associated factors in a nationwide study. DESIGN:Cross-sectional study. STUDY SAMPLE:We investigated the prevalence of HL in 10,845 participants ≥12 years of age and analysed the associated factors with HL from 7434 participants ≥40 years of age. RESULTS:Th...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2017.1373866

    authors: Park HJ,Yoo MH,Woo SY,Kim SW,Cho YS

    更新日期:2017-12-01 00:00:00

  • When expectation meets experience: parents' recollections of and experiences with a child diagnosed with hearing loss soon after birth.

    abstract:OBJECTIVE:To examine parents' recollections of and their experiences with bringing up a child diagnosed with hearing loss at a very young age. DESIGN:Based on the analysis of informal parent discussion groups, four open-ended questions were formulated to solicit information about parents' expectations following diagno...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2013.825051

    authors: Gilliver M,Ching TY,Sjahalam-King J

    更新日期:2013-12-01 00:00:00

  • A convergent validity study: Listening in Spatialized Noise-Sentences (LiSN-S) test and the Hearing in Noise Test (HINT).

    abstract:OBJECTIVES:The primary purpose of this study was to compare Listening in Spatialized Noise - Sentence (LiSN-S) test and the Hearing in Noise Test (HINT) thresholds in order to determine if the two tests measure the same construct (convergent validity). The secondary purpose was to determine performance differences betw...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2020.1791367

    authors: Vermiglio AJ,Bulla E,Skinner J,Heeke P,Fang X,Velappan K,Bonilla E,Garner E

    更新日期:2021-01-01 00:00:00

  • Voice gender discrimination provides a measure of more than pitch-related perception in cochlear implant users.

    abstract:OBJECTIVES:(1) To investigate whether voice gender discrimination (VGD) could be a useful indicator of the spectral and temporal processing abilities of individual cochlear implant (CI) users; (2) To examine the relationship between VGD and speech recognition with CI when comparable acoustic cues are used for both perc...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2011.576274

    authors: Li T,Fu QJ

    更新日期:2011-08-01 00:00:00

  • Effect of inverting electrode on mismatch negativity presence for perceptible/imperceptible tonal frequency contrasts.

    abstract::The effect of inverting electrode location and stimulus perceptibility on the presence of the mismatch negativity (MMN) evoked response was investigated in 20 normal-hearing adult females. Perceptible and imperceptible frequency contrasts were employed in an oddball paradigm. The perceptible contrast consisted of an 1...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020802283241

    authors: Walker-Black L,Stuart A

    更新日期:2008-11-01 00:00:00

  • Distortion product otoacoustic emissions: an objective technique for the screening of hearing loss in children treated with platin derivatives.

    abstract::In order to develop a sensitive audiometric protocol for identifying ototoxicity in children, a retrospective study of 16 children treated with cisplatin and/or carboplatin was performed. Audiometric testing was done by means of pure-tone threshold audiometry (PTA), high-frequency audiometry (HFA), and distortion prod...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020600582117

    authors: Dhooge I,Dhooge C,Geukens S,De Clerck B,De Vel E,Vinck BM

    更新日期:2006-06-01 00:00:00

  • The parents' perspective of the early diagnostic period of their child with hearing loss: information and support.

    abstract:OBJECTIVE:This study aimed to explore the perspectives of caregivers regarding the information and support they received following diagnosis of their child's hearing loss. DESIGN:A mixed methods explanatory sequential design was conducted. STUDY SAMPLE:A total of 445 caregivers of children completed a written survey,...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2017.1301683

    authors: Scarinci N,Erbasi E,Moore E,Ching TYC,Marnane V

    更新日期:2018-05-01 00:00:00

  • Self reported hearing difficulties following excision of vestibular schwannoma.

    abstract::A new questionnaire, developed to investigate self-reported hearing difficulties in unilateral deafness, was completed by 221 post-surgical vestibular schwannoma patients. Results were compared to a group of 51 normal hearers and 12 patients with severe unilateral deafness from other causes. The vestibular schwannoma ...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020802033083

    authors: McLeod B,Upfold L,Taylor A

    更新日期:2008-07-01 00:00:00

  • Evolving concepts of developmental auditory processing disorder (APD): a British Society of Audiology APD special interest group 'white paper'.

    abstract::Children with listening difficulties, but normal audiometry, may be diagnosed with APD. The diagnosis is typically based on poor performance on tests of perception of both non-speech and speech stimuli. However, non-speech test results correlate only weakly with evaluations of speech-in-noise processing, cognitive ski...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2012.723143

    authors: Moore DR,Rosen S,Bamiou DE,Campbell NG,Sirimanna T

    更新日期:2013-01-01 00:00:00

  • Adaptation of the "active communication education" programme into Spanish for older adults with hearing loss.

    abstract::Objective: To adapt the Active Communication Education (ACE) programme into Spanish. In addition, this study aimed at determining the effects of the adapted ACE programme on the social/emotional impacts of hearing loss and hearing functioning in a group of older adults with hearing loss who do not wear hearing aids.De...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2020.1740801

    authors: Rivera S,Marcotti A,Fuente A,Fuentes-López E,Hickson L

    更新日期:2020-09-01 00:00:00

  • Can adolescents and young adults with prelingual hearing loss benefit from a second, sequential cochlear implant?

    abstract::This study aimed to determine if adolescents/young adults gained additional perceptual benefit from sequential bilateral cochlear implants within 12 months, and to document adaptation to the second implant. Assessments comprised a pediatric version of The Speech, Spatial and Qualities of Hearing Scale (SSQ), anecdotal...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992020903470767

    authors: Galvin KL,Hughes KC,Mok M

    更新日期:2010-05-01 00:00:00

  • Choice of probe tone and classification of trace patterns in tympanometry undertaken in early infancy.

    abstract::Tympanometry using 226 Hz, 678 Hz, and 1000 Hz probe tones was undertaken on two groups of babies, age 2 to 21 weeks. A group of 104 babies with normal ABR thresholds or TEOAEs were compared with a second group of 107 babies who had evidence of temporary conductive hearing loss based on the findings of a test battery,...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992020600690951

    authors: Baldwin M

    更新日期:2006-07-01 00:00:00

  • A systematic review of stimulus parameters for eliciting distortion product otoacoustic emissions from adult humans.

    abstract:OBJECTIVE:The objective of this study is to review the scientific literature to determine if a set of stimulus parameters can be described to elicit distortion product otoacoustic emissions (DPOAEs) of higher absolute level and/or greater reliability in healthy adult humans and higher sensitivity and specificity in adu...

    journal_title:International journal of audiology

    pub_type: 杂志文章,评审

    doi:10.1080/14992027.2017.1290282

    authors: Petersen L,Wilson WJ,Kathard H

    更新日期:2017-06-01 00:00:00

  • Influence of stimulation position on the sensitivity for bone conduction hearing aids without skin penetration.

    abstract:OBJECTIVE:This study explores the influence of stimulation position on bone conduction (BC) hearing sensitivity with a BC transducer attached using a headband. DESIGN:(1) The cochlear promontory motion was measured in cadaver heads using laser Doppler vibrometry while seven different positions around the pinna were st...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2016.1172120

    authors: Dobrev I,Stenfelt S,Röösli C,Bolt L,Pfiffner F,Gerig R,Huber A,Sim JH

    更新日期:2016-08-01 00:00:00

  • Psychiatric comorbidity in a population of outpatients affected by tinnitus.

    abstract::The aim of this study was to outline the psychopathological characteristics of a population of outpatients affected by tinnitus and to consider its impact on their mental state and ability to function in major areas of their lives. Seventy-five consecutive tinnitus patients were enrolled on their first visit to the ou...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992020309056079

    authors: Marciano E,Carrabba L,Giannini P,Sementina C,Verde P,Bruno C,Di Pietro G,Ponsillo NG

    更新日期:2003-01-01 00:00:00

  • Hearing-aid use and long-term health outcomes: Hearing handicap, mental health, social engagement, cognitive function, physical health, and mortality.

    abstract:OBJECTIVE:To clarify the impact of hearing aids on mental health, social engagement, cognitive function, and physical health outcomes in older adults with hearing impairment. DESIGN:We assessed hearing handicap (hearing handicap inventory for the elderly; HHIE-S), cognition (mini mental state exam, trail making, audit...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2015.1059503

    authors: Dawes P,Cruickshanks KJ,Fischer ME,Klein BE,Klein R,Nondahl DM

    更新日期:2015-01-01 00:00:00

  • Hearing aid review appointment: clients' reasons for attendance and non-attendance.

    abstract::Objective: To investigate hearing aid owners' decisions to attend or not to attend an annual hearing aid review (HAR) appointment. To investigate the possible factors associated with appointment attendance, including age, gender, transportation, travel time, and hearing aid outcomes.Design: A prospective cohort study....

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.1080/14992027.2019.1663373

    authors: Bennett RJ,Zhang M,Mulders WHAM,Stegeman I,Vagg B,Brennan-Jones CG,Eikelboom RH

    更新日期:2020-02-01 00:00:00

  • Older adults expend more listening effort than young adults recognizing audiovisual speech in noise.

    abstract:OBJECTIVE:Using a dual task paradigm, two experiments were conducted to: (1) quantify the listening effort that young and older adults expend to recognize speech in noise when presented under audio-only (Experiment 1) and audiovisual conditions (Experiment 2) and, (2) determine the influence visual cues have on listeni...

    journal_title:International journal of audiology

    pub_type: 杂志文章

    doi:10.3109/14992027.2011.599870

    authors: Gosselin PA,Gagné JP

    更新日期:2011-11-01 00:00:00

  • The effect of tinnitus specific intracochlear stimulation on speech perception in patients with unilateral or asymmetric hearing loss accompanied with tinnitus and the effect of formal auditory training.

    abstract:OBJECTIVES:Previous studies show that intracochlear electrical stimulation independent of environmental sounds appears to suppress tinnitus, even long-term. In order to assess the viability of this potential treatment option it is essential to study the effects of this tinnitus specific electrical stimulation on speech...

    journal_title:International journal of audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1080/14992027.2017.1408964

    authors: Arts RAGJ,George ELJ,Janssen MAML,Griessner A,Zierhofer C,Stokroos RJ

    更新日期:2018-06-01 00:00:00