Predictive value of early IOP in mitomycin-C augmented trabeculectomy.

Abstract:

PURPOSE:To determine whether early intraocular pressure (IOP) after mitomycin-C (MMC) augmented trabeculectomy has any predictive value for intermediate IOP outcome. METHODS:Retrospective case note review. All cases of trabeculectomy using MMC augmentation and at least 1-year follow-up during the study period were included. Cases where a bleb leak occurred were excluded from the analysis. Only first eyes operated upon during the study period were included. Patient demographics and postoperative course were documented and analyzed. Early IOP measurements at day 1, day 7, and month 1 postoperatively were correlated to IOP at 1 year or final follow-up. RESULTS:One hundred nineteen trabeculectomies were identified. Of these 27 (22.7%) had an early bleb leak and were excluded. Further analysis was carried out on the remaining 92 cases. Mean age of cases was 70.8 years. Nine cases (9.8%) were repeat trabeculectomies. Mean follow-up time was 18.5 months (range 12 to 60 mo). Patients with a final IOP of < or =16 mm Hg (without drops or further surgery) (unqualified successes) had a mean day 1 IOP of 12.5 mm Hg compared with 17.4 mm Hg in those with an IOP more than 16 mm Hg at final follow-up (P=0.02). Patients with a final IOP of < or =16 mm Hg (with or without drops) (qualified successes) had mean day 1 IOP of 13.3 mm Hg compared with 17.1 mm Hg in those with an IOP of >16 mm Hg at final follow-up (P=0.06). At 1 month the mean IOPs were 10.7 mm Hg and 19.5 mm Hg, respectively (P<0.001). By logistic regression analysis at final recorded visit those cases in the lowest IOP quartile at 1 month were 14 times more likely to have an IOP < or =16 mm Hg without treatment than those in the highest quartile at 1 month. CONCLUSIONS:Our data suggests that a low early postoperative IOP measurement is a predictive factor for IOP value and success after intermediate length follow-up in patients undergoing trabeculectomy surgery augmented with MMC.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Alwitry A,Moodie J,Rotchford A,Abedin A,Patel V,King AJ

doi

10.1097/IJG.0b013e31805d014a

subject

Has Abstract

pub_date

2007-10-01 00:00:00

pages

616-21

issue

7

eissn

1057-0829

issn

1536-481X

pii

00061198-200710000-00007

journal_volume

16

pub_type

杂志文章
  • Risk factors for decompression retinopathy after glaucoma surgery.

    abstract:PURPOSE:To evaluate the risk factors for decompression retinopathy after glaucoma surgery. METHODS:We reviewed the medical records of patients who underwent a trabeculectomy or Ahmed valve implantation and divided them into 2 groups by the development of decompression retinopathy. Various factors were compared between...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318287aba0

    authors: Jung KI,Lim SA,Lopilly Park HY,Park CK

    更新日期:2014-12-01 00:00:00

  • Evaluation of Quality of Life in Japanese Glaucoma Patients and its Relationship With Visual Function.

    abstract:PURPOSE:We assessed vision-related quality of life (VR-QOL) in glaucoma patients and examined the relationship between VR-QOL and indices of visual function and subjective symptoms. PATIENTS AND METHODS:Four hundred seventy-two glaucoma patients completed a questionnaire concerning VR-QOL and subjective symptoms of gl...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/IJG.0000000000000221

    authors: Takahashi G,Otori Y,Urashima M,Kuwayama Y,Quality of Life Improvement Committee.

    更新日期:2016-03-01 00:00:00

  • Peripapillary Vessel Density in Glaucomatous Eyes: Comparison Between Pseudoexfoliation Glaucoma and Primary Open-angle Glaucoma.

    abstract:PURPOSE:The aim of this study was to compare the peripapillary vessel density between eyes with pseudoexfoliation glaucoma (PXG) and eyes with primary open-angle glaucoma (POAG). METHODS:Peripapillary vessel density in the radial peripapillary capillaries was assessed using optical coherence tomography angiography, an...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001062

    authors: Park JH,Yoo C,Girard MJA,Mari JM,Kim YY

    更新日期:2018-11-01 00:00:00

  • Autologous patch graft in tube shunt surgery.

    abstract:PURPOSE:To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. METHODS:A retrospective study of 16 patients (17 eyes) who underwent tube...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Aslanides IM,Spaeth GL,Schmidt CM,Lanzl IM,Gandham SB

    更新日期:1999-10-01 00:00:00

  • Diurnal pattern of intraocular pressure is affected by microgravity when measured in space with the pressure phosphene tonometer (PPT).

    abstract:PURPOSE:This study was designed to evaluate the effect of microgravity on the diurnal variation of intraocular pressure (IOP). METHODS:IOPs were measured with the pressure phosphene tonometer in 1 subject (the first Korean astronaut) during spaceflight. IOPs were measured every 3 hours during day time (6 times per day...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181f464d2

    authors: Chung KY,Woo SJ,Yi S,Choi GH,Ahn CH,Hur GC,Lim JG,Kim TW

    更新日期:2011-10-01 00:00:00

  • Replacing maximum-tolerated medications with latanoprost versus adding latanoprost to maximum-tolerated medications: a two-center randomized prospective trial.

    abstract:PURPOSE:To compare the replacement of every drug with latanoprost 0.005% once a day in glaucomatous eyes with poorly controlled intraocular pressure upon combination therapy, versus addition of latanoprost to the pre-existing treatment. PATIENTS AND METHODS: STUDY DESIGN:prospective, investigator-masked, two-center, ...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/00061198-200308000-00009

    authors: Gandolfi SA,Rossetti L,Cimino L,Mora P,Tardini M,Orzalesi N

    更新日期:2003-08-01 00:00:00

  • Postural response of intraocular pressure and visual field damage in patients with untreated normal-tension glaucoma.

    abstract:PURPOSE:To evaluate whether postural changes of intraocular pressure (IOP) are associated with visual field damage by comparing both eyes of patients with previously untreated normal-tension glaucoma (NTG). PATIENTS AND METHODS:Forty eyes of 20 patients newly diagnosed as bilateral NTG were studied. IOP was measured i...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181a98f30

    authors: Kiuchi T,Motoyama Y,Oshika T

    更新日期:2010-03-01 00:00:00

  • Measurement of superficial optic nerve head capillary blood velocities by scanning laser fluorescein angiography.

    abstract::Scanning laser ophthalmoscopy is capable of producing video fluorescein angiograms with high spatial and temporal resolution. Digital image analysis of these angiograms has been used to produce measures of capillary flow velocities in perimacular capillaries. We have recently utilized the same technique to measure flo...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Cantor LB,Harris A,Wolf S,Sponsel WE,Arend O

    更新日期:1994-07-01 00:00:00

  • The effect of dehydration and fasting on ocular blood flow.

    abstract:PURPOSE:To investigate the effects of dehydration and fasting on retrobulbar-vessel blood velocity in healthy subjects. METHODS:Twenty-eight eyes of 28 normal subjects without ocular disease were enrolled in this study. Each subject had a baseline color-Doppler imaging ultrasound of the central retinal artery, tempora...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200210000-00007

    authors: Inan UU,Yücel A,Ermis SS,Oztürk F

    更新日期:2002-10-01 00:00:00

  • Two-year Results After Deep Sclerectomy With Nonabsorbable Uveoscleral Implant (Esnoper-Clip): Surgical Area Analysis Using Anterior Segment Optical Coherence Tomography.

    abstract:PURPOSE:To report 2-year results of deep sclerectomy (DS) with mitomycin C and the uveoscleral implant Esnoper-Clip (AJL Ophthalmics, Álava, Spain), a nonabsorbable hema implant, and the morphologic analysis of the surgical area with anterior segment optical coherence tomography (AS-OCT). MATERIALS AND METHODS:In tota...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000756

    authors: Romera-Romero P,Loscos-Arenas J,Moll-Udina A,Romanic-Bubalo N,Castellvi-Manent J,Valldeperas X

    更新日期:2017-10-01 00:00:00

  • Clinical Presentation and Management Outcomes of Coexistent Congenital Glaucoma and Retinopathy of Prematurity.

    abstract:PURPOSE:The purpose of this study was to report presentation and outcomes of coexisting congenital glaucoma with retinopathy of prematurity (ROP) in "Indian Twin cities ROP study (ITCROPS)." METHODS:Children with ROP and congenital glaucoma were identified from ITCROPS (prospective digital database) between 1997 and 2...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001124

    authors: Senthil S,Balijepalli P,Garudadri C,Jalali S

    更新日期:2019-01-01 00:00:00

  • Prevalence and correlates of self-reported nonadherence with eye drop treatment: the Belgian Compliance Study in Ophthalmology (BCSO).

    abstract:PURPOSE:This study aimed to investigate (1) the prevalence of nonadherence with eye drop treatment; (2) selected correlates of nonadherence at the patient and health-care organization level; and (3) the diagnostic value of the ophthalmologists' ratings, using patients' self-reports as standard. METHODS:This cross-sect...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/IJG.0b013e3181f7b10e

    authors: Vandenbroeck S,De Geest S,Dobbels F,Fieuws S,Stalmans I,Zeyen T

    更新日期:2011-09-01 00:00:00

  • Corneal parameters and difference between goldmann applanation tonometry and dynamic contour tonometry in normal eyes.

    abstract:PURPOSE:To compare the difference between 2 methods of measuring the intraocular pressure (IOP), namely, Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) and to study the relationship with the corneal parameters in patients with no glaucoma signs. METHODS:One hundred and eighteen eyes of 118 he...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31816224bd

    authors: Lanza M,Borrelli M,De Bernardo M,Filosa ML,Rosa N

    更新日期:2008-09-01 00:00:00

  • Comparison of fluctuations of intraocular pressure before and after selective laser trabeculoplasty in normal-tension glaucoma patients.

    abstract:PURPOSE:The aim of this study was to examine the effects of selective laser trabeculoplasty (SLT) treatment on habitual intraocular pressure (IOP) fluctuations in patients with normal-tension glaucoma (NTG) using a SENSIMED Triggerfish contact lens sensor (CLS). MATERIALS AND METHODS:Ten patients diagnosed with NTG we...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章

    doi:10.1097/IJG.0000000000000026

    authors: Tojo N,Oka M,Miyakoshi A,Ozaki H,Hayashi A

    更新日期:2014-10-01 00:00:00

  • A randomized clinical trial of selective laser trabeculoplasty versus argon laser trabeculoplasty in patients with pseudoexfoliation.

    abstract:PURPOSE:To evaluate the efficacy of selective laser trabeculoplasty (SLT) versus argon laser trabeculoplasty (ALT) in lowering the intraocular pressure (IOP) in patients with open-angle glaucoma or ocular hypertension secondary to pseudoexfoliation. DESIGN:Multicentered randomized clinical trial. PARTICIPANTS:A total...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/IJG.0b013e31829e55e4

    authors: Kent SS,Hutnik CM,Birt CM,Damji KF,Harasymowycz P,Si F,Hodge W,Pan I,Crichton A

    更新日期:2015-06-01 00:00:00

  • Asymmetry of Macular Vessel Density in Bilateral Early Open-angle Glaucoma With Unilateral Central 10-2 Visual Field Loss.

    abstract::PRéCIS:: Glaucomatous eyes without detectable 10-2 visual field loss showed significant macular vessel density loss, especially in inferior quadrant of perifoveal area. Macular vessel density loss spatially corresponded with structural and functional damage. PURPOSE:The purpose of this study was to investigate the ch...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001578

    authors: Lu P,Xiao H,Chen H,Ye D,Huang J

    更新日期:2020-10-01 00:00:00

  • Reproducibility of the new Goldmann AT900D digital tonometer.

    abstract:PURPOSE:To examine the reproducibility of the new digital Goldmann applanation tonometer AT 900D (DGT) for measuring intraocular pressure and to compare its readings with those provided by the conventional analog Goldmann tonometer (AGT). METHODS:In 3 different sessions (S1, S2, and S3), 3 intraocular pressure measure...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31820bd1e9

    authors: Morales-Fernandez L,Martinez-de-la-Casa JM,Garcia-Feijoo J,Saenz-Frances F,Santos-Bueso E,Garcia-Sanchez J

    更新日期:2012-03-01 00:00:00

  • Concordance of high-pass resolution perimetry and frequency-doubling technology perimetry results in glaucoma: no support for selective ganglion cell damage.

    abstract:PURPOSE:To compare the results of frequency-doubling technology perimetry (FDT), assumed to test the magnocellular visual pathway, and high-pass resolution perimetry (HRP), assumed to test the parvocellular visual pathway, in patients with ocular hypertension or glaucoma. PATIENTS AND METHODS:Forty-eight consecutive p...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200302000-00008

    authors: Martin L,Wanger P,Vancea L,Göthlin B

    更新日期:2003-02-01 00:00:00

  • Surgical Technique for Pars Plana Ahmed Glaucoma Valve Implantation in Advanced Glaucoma: The Upside-Down Technique.

    abstract:PRCIS:Ahmed glaucoma valve implantation using the upside-down technique resulted in an aqueous humor outflow pathway, occurring primarily on the scleral side and secondarily on the conjunctival side, and was effective in treating refractory glaucoma. PURPOSE:To describe the Ahmed glaucoma valve (AGV) surgical techniqu...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001791

    authors: Masuda Y,Saito Y,Oki T,Hayashi T,Takahashi G,Nakano T

    更新日期:2021-01-13 00:00:00

  • Changes in Ocular Hypotensive Drug Usage for Glaucoma Treatment After Cataract Surgery: A Nationwide Population-based Study in Taiwan.

    abstract:PURPOSE:The aims of this study were to observe the changes in the demand for prescriptions of ocular hypertensive drug (OHD) after cataract surgery, to investigate patterns of change in the required OHD amount in open-angle glaucoma (OAG) and angle-closure glaucoma (ACG) cases, and to determine the associated factors r...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000969

    authors: Chang PY,Wang JY,Chang SW,Chang YC

    更新日期:2018-07-01 00:00:00

  • Clinical Implications of In Vivo Lamina Cribrosa Imaging in Glaucoma.

    abstract::The lamina cribrosa (LC) is a multilayered, collagenous, sieve-like structure at the deep optic nerve head, and is presumed to be the primary site of axonal injury. According to biomechanical theory, intraocular pressure-induced posterior deformation of the LC causes blockage of axonal transport and alters the ocular ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000728

    authors: Kim YW,Jeoung JW,Kim YK,Park KH

    更新日期:2017-09-01 00:00:00

  • Effects of Axial Length and Age on Circumpapillary Retinal Nerve Fiber Layer and Inner Macular Parameters Measured by 3 Types of SD-OCT Instruments.

    abstract:PURPOSES:To evaluate the effects of axial length and age on the circumpapillary retinal nerve fiber layer (cpRNFL) and the inner macular parameters measured using 3 spectral-domain optical coherence tomography (OCT) instruments. METHODS:A total of 102 normal eyes (1 eye per subject) were imaged using Cirrus, RTVue, an...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000216

    authors: Ueda K,Kanamori A,Akashi A,Tomioka M,Kawaka Y,Nakamura M

    更新日期:2016-04-01 00:00:00

  • Influence of Ocular Dimensional Change on 24-Hour Intraocular Pressure Measurement With Contact Lens Sensor.

    abstract:PURPOSE:We measured changes in the corneal morphology and intraocular pressure (IOP) before and after the use of contact lens sensor (CLS). Then, we investigated whether the ocular dimensional change affected the measured IOP value with CLS. MATERIAL AND METHODS:In this prospective study, we examined 112 eyes of glauc...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001318

    authors: Tojo N,Hayashi A

    更新日期:2019-09-01 00:00:00

  • Peripapillary focal retinal arteriolar narrowing in open angle glaucoma.

    abstract:PURPOSE:Optic disc photographs of 750 patients attending a glaucoma practice were examined to identify focal peripapillary arteriolar narrowing. METHODS:A subgroup of 110 of these patients' photographs, who had also had finger circulation tested for vasospasm to cold, were divided into patients with peripapillary foca...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Rankin SJ,Drance SM

    更新日期:1996-02-01 00:00:00

  • Fluctuation of Bacteria on Bleb Surface After Trabeculectomy With Adjunctive Mitomycin C.

    abstract:PURPOSE:To determine whether the bacterial and floral patterns on the bleb surface are affected by the season in eyes that had undergone trabeculectomy with adjunctive mitomycin C. PATIENTS AND METHODS:Forty-four glaucoma patients who had an avascular or a hypovascular cystic filtering bleb were studied. Swabs of the ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000305

    authors: Takahashi N,Sawada A,Mochizuki K,Katada T,Yamamoto T

    更新日期:2016-05-01 00:00:00

  • Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes.

    abstract:PURPOSE:To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs. MATERIALS AND METHODS:Twenty-seven eyes of 27 patients with open-angle glaucoma,...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000253

    authors: Loscos-Arenas J,Parera-Arranz A,Romera-Romera P,Castellvi-Manent J,Sabala-Llopart A,de la Cámara-Hermoso J

    更新日期:2015-08-01 00:00:00

  • A new model of glaucoma filtering surgery in the rat.

    abstract:PURPOSE:The most common reason for long-term failure of glaucoma filtering surgery (GFS) is scarring of the external filtering "bleb" tissues. The identification of the factors that mediate this process, as well as the development and initial testing of new therapies to limit scarring is enhanced by the use of appropri...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000131482.86547.5a

    authors: Sherwood MB,Esson DW,Neelakantan A,Samuelson DA

    更新日期:2004-10-01 00:00:00

  • Sterile single use cover for the G-probe Transscleral Cyclodiode.

    abstract:PURPOSE:Multiuse of the G-probe transscleral cyclophotocoagulation (TSCPC) device can lead to contamination. We evaluated the mechanical stability and clinical efficacy of a disposable sterile barrier for the G-probe footplate. METHODS:We measured diode laser output with and without the G-probe barrier both before and...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181e08109

    authors: Rootman DB,Howarth D,Kerr JQ,Flanagan JG,Trope GE,Buys YM

    更新日期:2011-04-01 00:00:00

  • Ciliary body melanocytoma with anterior segment pigment dispersion and elevated intraocular pressure.

    abstract:PURPOSE:To discuss a case in which melanocytoma of the ciliary body presented with widespread pigment dispersion and elevated intraocular pressure (IOP). METHODS:A 64-year old woman presented with increased IOP and persistent anterior segment inflammation in her right eye. She had undergone a trabeculectomy for uncont...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Bhorade AM,Edward DP,Goldstein DA

    更新日期:1999-04-01 00:00:00

  • Surgical outcomes of the Baerveldt Glaucoma Implant: differences between surgical techniques in the Rotterdam Eye Hospital.

    abstract:PURPOSE:During the last decades, the Baerveldt Glaucoma Implant (BGI) has proven effective in the surgical treatment of glaucoma. Various surgical procedures have been used for its implantation and these may yield different clinical outcomes and different intraoperative and postoperative complications. We evaluated the...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3182447b7c

    authors: Poels MM,Niessen AG,de Waard PW,Lemij HG

    更新日期:2013-06-01 00:00:00