Monte Carlo calculations applied to the parametrical studies in a whole body counter.

Abstract:

:The use of a Monte Carlo code for the analysis and interpretation of whole body counting measurements is described. The sources of error are analysed and commented to show how a counting geometry can be improved by improving accuracy and precision in a measurement. The effects of body size, contamination distribution and counting geometry are also parameters which can be easily used to improve the quality of a body burden assessment. The optimisation of the detector (position, shielding, shape and size) is also commented on the basis of calculations in the photon energy range usually encountered in routine measurements. The results obtained from these simulations are confirmed by experimental results.

journal_name

Radiat Prot Dosimetry

authors

Genicot JL,Koukouliou V,Carinou E

doi

10.1093/rpd/ncm242

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

49-61

issue

1

eissn

0144-8420

issn

1742-3406

pii

ncm242

journal_volume

128

pub_type

杂志文章
  • LEAD COMPOSITE VS. NONLEAD PROTECTIVE GARMENTS: WHICH ARE BETTER? A MULTIVENDOR COMPARISON.

    abstract::This study aims to provide more insight in attenuation characteristics and corresponding lead (Pb) equivalences of a broad range of commercially available lead composite and nonlead protective garments. Thirty garments of five manufacturers (listed as 0.25-0.35-0.50 mm Pb equivalent) were tested. Transmission values w...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw373

    authors: Peters SMB,Zweers D,de Lange F,Mourik JEM

    更新日期:2017-08-01 00:00:00

  • Determination of 137Cs and 60Co pollution in the area of the Laguna Verde Nuclear Power Plant, Mexico.

    abstract::The project 'Radiological Analysis of Environmental Samples in the Gulf of Mexico and the coast of Quintana Roo', had the aim of identifying and quantifying anthropogenic radionuclides in environmental samples consisting of silt, sand and sea water. This paper presents the results of the radiological analysis of these...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv250

    authors: Salas Mar B

    更新日期:2015-11-01 00:00:00

  • Indoor radon and thoron levels in Neendakara and Chavara regions of southern coastal Kerala, India.

    abstract::Some areas of the world, called high background radiation areas (HBRAs), have anomalously high levels of natural background radiation and the population residing in the areas is exposed to higher levels of radiation doses than other parts of the world where the natural radioactivity contents are normal. In the present...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr399

    authors: Pereira CE,Vaidyan VK,Chougaonkar MP,Mayya YS,Sahoo BK,Jojo PJ

    更新日期:2012-07-01 00:00:00

  • ANALYSIS BY SCANNER OF TRACKS PRODUCED BY RADON ALPHA PARTICLES IN CR-39 DETECTORS.

    abstract::The most used passive detectors for Radon measurement are the CR39s, both for the good stability of the material and for the practicality of use. But, commercial reading systems are expensive and not always fast. The aim of the present work was the development of a method for a rapid, efficient and economic evaluation...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa140

    authors: Sabbarese C,Ambrosino F,Roca V

    更新日期:2020-11-27 00:00:00

  • Radiation exposure from radioactive iodine 131I in and surrounding the patients' room.

    abstract::The purpose of this study is to measure the environmental radiation exposure in and surrounding the room of patients treated with (131)I. Absorbed dose rates were measured using thermoluminescence dosemeters, type TLD-200 (CaF(2):Dy), in a continuous monitoring programme. It is found that the estimated annual shallow ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp093

    authors: Abu-Khaled YS,Sandouqa AS,Haddadin IM

    更新日期:2009-07-01 00:00:00

  • A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    abstract::The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq002

    authors: Faulkner K,Järvinen H,Butler P,McLean ID,Pentecost M,Rickard M,Abdullah B

    更新日期:2010-04-01 00:00:00

  • Organ dose conversions from ESR measurements using tooth enamel of atomic bomb survivors.

    abstract::Dose conversions were studied for dosimetry of atomic bomb survivors based upon electron spin resonance (ESR) measurements of tooth enamel. Previously analysed data had clarified that the tooth enamel dose could be much larger than other organ doses from a low-energy photon exposure. The radiation doses to other organ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr408

    authors: Takahashi F,Sato K

    更新日期:2012-03-01 00:00:00

  • A new lead-free radiation shielding material for radiotherapy.

    abstract::Lead has recently been recognised as a source of environmental pollution, including the lead used for radiation shielding in radiotherapy. The bremsstrahlung radiation caused by the interaction between the electron beam and lead may reduce the accuracy of radiotherapy. To avoid the use of lead, a new material composed...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp053

    authors: Yue K,Luo W,Dong X,Wang C,Wu G,Jiang M,Zha Y

    更新日期:2009-02-01 00:00:00

  • Non-targeted effects of radiation: bystander responses in cell and tissue models.

    abstract::The standard paradigm for radiation effects in cellular systems has involved direct damage to DNA and in particular, DNA double strand breaks as the triggering lesions leading to mutation, cell death and transformation. Recently, however, a growing body of evidence has reported non-targeted effects, which are not a di...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006768

    authors: Prise KM,Belyakov OV,Newman HC,Patel S,Schettino G,Folkard M,Michael BD

    更新日期:2002-01-01 00:00:00

  • Neutron spectrometry in a PET cyclotron with a Bonner sphere system.

    abstract::Positron emission tomography (PET) is a non-invasive medical imaging technique normally used for diagnostic purposes to determine the location and concentration of physiologically active compounds in a human body. An unshielded cyclotron is used for PET at the Clinica Universitaria de Navarra to produce short-lived po...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm077

    authors: Fernández F,Amgarou K,Domingo C,García MJ,Quincoces G,Martí-Climent JM,Méndez R,Barquero R

    更新日期:2007-01-01 00:00:00

  • Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital.

    abstract::To assess the frequency of examination, image quality (IQ) and establishment of local diagnostic reference levels (LDRLs) in paediatric radiographic examinations. The X-ray device performance, film reject rate and IQ grading were assessed at Radiology Department of a referral and teaching children's hospital in Kenya....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs270

    authors: Wambani JS,Korir GK,Korir IK,Kilaha S

    更新日期:2013-05-01 00:00:00

  • Non-radiation induced signals in TL dosimetry.

    abstract::One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some eff...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006064

    authors: German U,Weinstein M

    更新日期:2002-01-01 00:00:00

  • Determination of the minimum measurement time for estimating long-term mean radon concentration.

    abstract::Radon measurements, as do any measurements, include errors in their readings. The relative values of such errors depend principally on the measurement methods used, the radon concentration to be measured and the duration of the measurements. Typical exposure times for radon surveys using passive detectors [nuclear tra...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs217

    authors: Janik M,Łoskiewicz J,Tokonami S,Kozak K,Mazur J,Ishikawa T

    更新日期:2012-11-01 00:00:00

  • Neutron absorbed dose determination by calculations of recoil energy.

    abstract::The aim of this work is to calculate the absorbed dose to matter due to neutrons in the 5-150 MeV energy range. Materials involved in the calculations are Al2O3, CaSO4 and CaS, which may be used as dosemeters and have already been studied for their luminescent properties. The absorbed dose is assumed to be mainly due ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch147

    authors: Wrobel F,Benabdesselam M,Iacconi P,Lapraz D

    更新日期:2004-01-01 00:00:00

  • Development of thermal neutron-sensitive glass dosemeter containing lithium.

    abstract::New radiophotoluminescence (RPL) phosphate glass containing (6)Li was successfully made from the powder of NaPO(3), Al(PO(3))(3), LiOH, HPO(3) and AgCl. The ternary diagram of NaPO(3)-Al(PO(3))(3)-LiPO(3) has clarified the region where satisfactory RPL characteristics of the glass are kept up. The synthesised phosphat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq552

    authors: Maki D,Kobayashi H,Sato F,Murata I,Kato Y,Tanaka T,Yamamoto T,Iida T

    更新日期:2011-03-01 00:00:00

  • Natural radioactivity measurements in building materials used in Samsun, Turkey.

    abstract::In this study, radioactivity levels of 35 different samples of 11 commonly used building materials in Samsun were measured by using a gamma spectrometry system. The analysis carried out with the high purity Germanium gamma spectrometry system. Radioactivity concentrations of (226)Ra, (232)Th and (40)K range from 6 to ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct047

    authors: Tufan MÇ,Disci T

    更新日期:2013-01-01 00:00:00

  • WHO's health risk assessment of ELF fields.

    abstract::The World Health Organization (WHO), the International Commission on Non-Ionizing Radiation Protection (ICNIRP), WHO's scientific collaborating centres (including the UK's National Radiological Protection Board (NRPB)) and over 50 participating Member States are participants of WHO's International EMF Project. As part...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006363

    authors: Repacholi MH

    更新日期:2003-01-01 00:00:00

  • The resulting skin dose in two-view mammography examinations.

    abstract::The entrance surface dose (ESD) (skin dose) and its variation due to overlapping radiation fields at mammography have been experimentally investigated on patients during two-view mammography screening examinations of both breasts and on phantoms of silicon gel. Measurements were done using multiple thermoluminescence ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq077

    authors: Adliene D,Cibulskaite I,Laurikaitiene J,Adlys G

    更新日期:2010-04-01 00:00:00

  • The newsletter 'European Research in Radiological Sciences'.

    abstract::The newsletter 'European Research in Radiological Sciences' is jointly published by the European Late Effects Project Group and the European Radiation Dosimetry Group to disseminate information about research projects and activities carried out under the EURATOM Framework Programme. Since May 2003, the Newsletter is o...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch095

    authors: Pihet P,d'Errico F,Dörr W,Gruenberger M,Schofield P

    更新日期:2004-01-01 00:00:00

  • Declassification of radioactive liquid wastes generated in radio immune assay [corrected] (RIA) laboratories.

    abstract::Radioactive liquid wastes of low-medium activity level are generated in radio immune assay (RIA) laboratories, which are also potentially infectious because of the pathogens from patient blood. The most common way of managing these wastes consists of a temporal storage, for partial radioactivity decay, followed by man...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci076

    authors: Sancho M,Arnal JM,Villaescusa JI,Campayo JM,Verdú G

    更新日期:2005-01-01 00:00:00

  • INTERVENTIONAL RADIOLOGICAL PROCEDURES MOST PRONE TO CAUSE HIGH PATIENT PEAK SKIN DOSES BASED ON REVIEW OF 7607 PROCEDURES.

    abstract::Peak skin doses to patients undergoing interventional radiological procedures in a 3-year period were assessed to identify the most critical procedures and evaluate probability for occurrence of radiation-induced tissue injuries. Data of 7607 patients were reviewed, identifying those with cumulative air kerma at a ref...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy119

    authors: Kuhelj D,Kovačič M,Zdešar U,Pekarovič D,Žontar D

    更新日期:2019-05-01 00:00:00

  • Study of natural radionuclide and absorbed gamma dose in Ukhimath area of Garhwal Himalaya, India.

    abstract::Natural radiation is the largest contributor to the collective radiation dose of the world population. It is widely distributed in different geological formations such as soil, rocks, air and groundwater. In the present investigation, (226)Ra, (232)Th and (40)K were measured in soil samples of the Ukhimath region of G...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncs187

    authors: Rautela BS,Yadav M,Bourai AA,Joshi V,Gusain GS,Ramola RC

    更新日期:2012-11-01 00:00:00

  • Neutron calibration facility with radioactive neutron sources at KRISS.

    abstract::For the purpose of radiation protection, the reference neutron field for calibration of neutron monitors was constructed using radioactive neutron sources-bare-(252)Cf, D(2)O-moderated (252)Cf and (241)Am-Be(alpha,n)-at Korea Research Institute of Standards and Science (KRISS). The well-specified neutron source with i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm034

    authors: Park H,Kim J,Choi KO

    更新日期:2007-01-01 00:00:00

  • Response of silicon diode dosemeters to scattered radiation from megavoltage photon beams.

    abstract::Dose response effects of diodes due to the high atomic number of silicon relative to water are investigated. While quality chances in the primary component of a megavoltage beam with depth are minimal. Compton scattered photons are shown to have a substantial effect on the quality leading to their enhanced absorption ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006014

    authors: Yin Z,Hugtenburg RP,Beddoe AH

    更新日期:2002-01-01 00:00:00

  • Determination of committed effective doses to skin due to ²³⁸U, ²³²Th and ²²²Rn from the application of various Moroccan black soap (Saboun Beldi) samples by members of the general public.

    abstract::(238)U, (232)Th, (222)Rn and (220)Rn concentrations were measured inside various Moroccan black soap samples widely used by the Moroccan population in traditional baths (Hammans) by using both CR-39 and LR-115 type II solid state nuclear track detectors. The measured (238)U, (232)Th, (222)Rn and (220)Rn concentrations...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq275

    authors: Misdaq MA,Outeqablit K

    更新日期:2010-12-01 00:00:00

  • Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project.

    abstract::The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in differen...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq508

    authors: Domienik J,Brodecki M,Carinou E,Donadille L,Jankowski J,Koukorava C,Krim S,Nikodemova D,Ruiz-Lopez N,Sans-Mercé M,Struelens L,Vanhavere F

    更新日期:2011-03-01 00:00:00

  • COMPARISON STUDY OF VARIOUS PLASTICS AS THE WALL MATERIAL OF THGEM-BASED MICRODOSEMETERS FOR FAST NEUTRON MEASUREMENTS.

    abstract::To find appropriate substitutions for the expensive plastics of A-150 and rexolite used in the construction of thick gas electron multiplier (THGEM)-based tissue-equivalent proportional counters, in the present work, the responses of a THGEM-based microdosimetric detector made of A-150 and rexolite and three others co...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw008

    authors: Moslehi A,Raisali G,Lamehi M

    更新日期:2017-04-15 00:00:00

  • Quality control of micro-computed tomography systems.

    abstract::The rapid proliferation of micro-computed tomography (micro-CT) scanners in preclinical small animal studies has created a need for a method on scanner performance evaluation and scan parameter optimisation. The purpose of this study was to investigate the performance of the scanner with a dedicated micro-CT phantom. ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq088

    authors: Eloot L,Buls N,Covens P,Willekens I,Lahoutte T,de Mey J

    更新日期:2010-04-01 00:00:00

  • The TSL neutron beam facility.

    abstract::A new quasi-monoenergetic neutron beam facility has been constructed at The Svedberg Laboratory (TSL) in Uppsala, Sweden. Key features include a neutron energy range of 11-175 MeV, high fluxes, user flux control, flexible neutron field size and shape, and spacious and easily accessible user area. The first results of ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm006

    authors: Prokofiev AV,Blomgren J,Byström O,Ekström C,Pomp S,Tippawan U,Ziemann V,Osterlund M

    更新日期:2007-01-01 00:00:00

  • Thorium isotopic analysis by alpha spectrometry.

    abstract::The technique of alpha spectrometry is used to detect alpha particles and to determine their energy. In this way the technique is able to provide simultaneously quantitative information (i.e. the activity) and qualitative information (the identity) on any radionuclide that emits an alpha particle. The longer-lived nat...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006646

    authors: Gingell T

    更新日期:2001-01-01 00:00:00