Quality control of micro-computed tomography systems.

Abstract:

:The rapid proliferation of micro-computed tomography (micro-CT) scanners in preclinical small animal studies has created a need for a method on scanner performance evaluation and scan parameter optimisation. The purpose of this study was to investigate the performance of the scanner with a dedicated micro-CT phantom. The phantom was developed with different independent sections that allow for measurement of major scanner characteristics such as uniformity, linearity, contrast response, dosimetry and resolution. The results of a thorough investigation are discussed.

journal_name

Radiat Prot Dosimetry

authors

Eloot L,Buls N,Covens P,Willekens I,Lahoutte T,de Mey J

doi

10.1093/rpd/ncq088

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

463-7

issue

1-3

eissn

0144-8420

issn

1742-3406

pii

ncq088

journal_volume

139

pub_type

杂志文章
  • The use of a figure-of-merit (FOM) for optimisation in digital mammography: a literature review.

    abstract::The use of image quality parameters in digital mammography such as contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) has been widespread, with the intention of detector evaluation and/or quantitative evaluation of the system performance. These parameters are useful in en...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncr465

    authors: Borg M,Badr I,Royle GJ

    更新日期:2012-08-01 00:00:00

  • PATIENT DOSE ASSESSMENT AFTER INTERVENTIONAL CARDIOLOGY PROCEDURES: A MULTI-CENTRIC APPROACH TO TRIGGER OPTIMISATION.

    abstract::As the number and complexity of fluoroscopically guided interventions increase, a serious effort has to be put on the optimisation of the X-ray dose delivered to the patient. In order to set up this optimisation process, the clinical practice for a given cardiology centre has to be analysed with relevant statistical p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncv525

    authors: Ryckx N,Goy JJ,Stauffer JC,Verdun FR

    更新日期:2016-06-01 00:00:00

  • Natural radioactivity levels in lake sediment samples.

    abstract::The radioactivity concentrations of nuclides (238)U, (232)Th and (40)K in lake sediments collected from 15 different stations at Altınkaya dam lake and 12 different stations at Derbent dam lake in Turkey were measured using high-resolution gamma-ray spectrometry. The measurement was done using a coaxial HPGe detector ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct071

    authors: Eroğlu H,Kabadayi Ö

    更新日期:2013-09-01 00:00:00

  • HOW DO HOSPITAL STERILISATION PROCEDURES AFFECT THE RESPONSE OF PERSONAL EXTREMITY RINGS AND OF EYE LENS TL DOSEMETERS?

    abstract::Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effec...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv539

    authors: Kopeć R,Bubak A,Budzanowski M,Sas-Bieniarz A,Szumska A

    更新日期:2016-09-01 00:00:00

  • Fast neutron spectrometry and dosimetry using a spherical moderator with position-sensitive detectors.

    abstract::A neutron spectrometry and dosimetry measurement system has been developed based on a different design of the divided regions for a sphere, with three position-sensitive counters. The characteristics of the measurement system have been investigated in the reference radiation fields of Am-Be and (252)Cf sources. When r...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl077

    authors: Li T,Yang L,Ma J,Fang D

    更新日期:2007-01-01 00:00:00

  • MITOCHONDRIAL MEMBRANE POTENTIAL, MORPHOLOGY AND ATP PRODUCTION IN MAMMALIAN CELLS EXPOSED TO X-RAYS.

    abstract::This study aimed to reveal the effect of X-irradiation on mitochondrial function in terms of mitochondrial membrane potential (ΔΨm) and ATP productivity. At the cellular level, ΔΨm was quantified using JC-1, a mitochondrial probe that emits red or green fluorescence at high or low ΔΨm sites, respectively. The fluoresc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy254

    authors: Hamada R,Kaminaga K,Suzuki K,Yokoya A

    更新日期:2019-05-01 00:00:00

  • High-Dose TL Dosimetry of Reactor Neutrons.

    abstract::Radiation dose was measured with set of TL dosimeters during checkout of neutron radiation hardness of the ORTEC preamplifier type 142A in the experiment at the MARIA nuclear reactor at the National Centre for Nuclear Research (NCBJ), Otwock-Świerk, Poland. Different types of LiF-based TL detectors have been used for ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx244

    authors: Obryk B,Malik K,Bilski P,Igielski A,Dankowski J,Kurowski A,Prokopowicz R,Pytel K

    更新日期:2018-08-01 00:00:00

  • The first operational dosemeter for neutrons which complies with IEC standard 1323.

    abstract::Individual neutron dosimetry represents one of the current difficulties in the field of radiological protection of workers. Since March 1999, the regulatory requirements in France for active (i.e. operational) dosimetry have been those of ICRP Publication 60, applicable from May 2000, necessitating the introduction of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006592

    authors: Lahaye T,Cutarella D,Ménard S,Bolognese-Milsztajn T

    更新日期:2001-01-01 00:00:00

  • Fishing for radiation quality: chromosome aberrations and the role of radiation track structure.

    abstract::The yield of chromosome aberrations is not only dependent on dose but also on radiation quality, with high linear energy transfer (LET) typically having a greater biological effectiveness per unit dose than those of low-LET radiation. Differences in radiation track structure and cell morphology can also lead to quanti...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv151

    authors: Hill MA

    更新日期:2015-09-01 00:00:00

  • THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013): AN INTRODUCTION TO THE DOCUMENTATION.

    abstract::The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013....

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx020

    authors: Napier BA

    更新日期:2017-11-01 00:00:00

  • Radiative models for the evaluation of the UV radiation at the ground.

    abstract::The variety of radiative models for solar UV radiation is discussed. For the evaluation of measured UV radiation at the ground the basic problem is the availability of actual values of the atmospheric parameters that influence the UV radiation. The largest uncertainties are due to clouds and aerosol, which are highly ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp211

    authors: Koepke P

    更新日期:2009-12-01 00:00:00

  • Protection from radon exposure at home and at work in the directive 2013/59/Euratom.

    abstract::In recent years, international organisations involved in radiation protection and public health have produced new guidance, recommendations and requirements aiming better protection from radon exposure. These organisations have often worked in close collaboration in order to facilitate the establishment of harmonised ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu101

    authors: Bochicchio F

    更新日期:2014-07-01 00:00:00

  • CT dosimetry: getting the best from the adult Cristy phantom.

    abstract::The use of geometrical phantoms for computed tomography (CT) dosimetry can incur errors in the calculation of effective dose due to the anatomically incorrect organ shapes and distributions, and unrepresentative body dimensions. A Monte Carlo program that makes use of an anatomically correct voxel phantom has been dev...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch521

    authors: Castellano IA,Dance DR,Evans PM

    更新日期:2005-01-01 00:00:00

  • Personal dose equivalent conversion coefficients for electrons to 1 Ge V.

    abstract::In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr252

    authors: Veinot KG,Hertel NE

    更新日期:2012-04-01 00:00:00

  • Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments.

    abstract::High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with (252)Cf neutron sources and are used in various wor...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu298

    authors: Lee KW,Sheu RJ

    更新日期:2015-04-01 00:00:00

  • Non-radiation induced signals in TL dosimetry.

    abstract::One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some eff...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006064

    authors: German U,Weinstein M

    更新日期:2002-01-01 00:00:00

  • New data on direct ion storage dosemeters.

    abstract::The DIS-1 dosemeter from the Finnish company RADOS is an innovative kind of passive electronic dosemeter for photon and beta radiation. This study examines the 'long-term' linear response behaviour, the calibration and readout accuracy with large samples of 'used' DIS-1 dosemeters especially in the low-dose region, wh...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm240

    authors: Fuchs H,Stähler S,Dittmar M

    更新日期:2008-01-01 00:00:00

  • DEVELOPMENT OF A NATIONAL EMERGENCY PLAN FOR MEDICAL DIAGNOSTICS AND THERAPY OF DETERMINISTIC EFFECTS AFTER RADIATION ACCIDENTS.

    abstract::The focus of nuclear emergency planning in Austria has been so far on mitigating effects of widespread contamination (e.g. after NPP accidents); however, these plans did not contain provisions on the medical management of an acute radiation syndrome. To close this gap, a 'Medical Radiation Emergency Plan' was created ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw210

    authors: Ziegler A

    更新日期:2016-09-01 00:00:00

  • Japanese adult male voxel phantom constructed on the basis of CT images.

    abstract::A Japanese adult male voxel (volume pixel) phantom (hereinafter referred to as the JM phantom) was constructed on the basis of CT images of a healthy Japanese adult male volunteer. Body characteristics of the JM phantom were compared with those of a voxelised MIRD5 type phantom and a Japanese adult male voxel phantom ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl101

    authors: Sato K,Noguchi H,Emoto Y,Koga S,Saito K

    更新日期:2007-01-01 00:00:00

  • Variability of radiocaesium inventory in Fukushima soil cores from one site measured at different times.

    abstract::The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident has resulted in the deposition of radioactive contamination of soils mainly by (134)Cs and (137)Cs. The contaminated areas are of a great concern since external radiation may lead to significant long-term doses to humans and animals. External dose rate above g...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncv276

    authors: Mishra S,Sahoo SK,Arae H,Sorimachi A,Hosoda M,Tokonami S,Ishikawa T

    更新日期:2015-11-01 00:00:00

  • Thermoluminescence properties of KCl(1-X)KBrX:Pb2+ mixed crystals.

    abstract::A study is presented of the thermoluminescence (TL) of phosphors based on potassium halides doped with divalent lead, such as KCl:Pb2+, KBr:Pb2+ and the crystalline series KCl(1-X)Br(X):Pb2+. The defects in the crystals generated by irradiation have been investigated as well as the trapping and room temperature recomb...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005913

    authors: Cruz-Zaragoza E,Meléndrez R,Chernov V,Barboza-Flores M,Piters TM,Hernández JA,Murrieta HS

    更新日期:2002-01-01 00:00:00

  • A comparative study of quality control in diagnostic radiology.

    abstract::The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn096

    authors: Kharita MH,Khedr MS,Wannus KM

    更新日期:2008-01-01 00:00:00

  • The response of a bonner sphere spectrometer to charged hadrons.

    abstract::Bonner sphere spectrometers (BSSs) are employed in neutron spectrometry and dosimetry since many years. Recent developments have seen the addition to a conventional BSS of one or more detectors (moderator plus thermal neutron counter) specifically designed to improve the overall response of the spectrometer to neutron...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch187

    authors: Agosteo S,Dimovasili E,Fassò A,Silari M

    更新日期:2004-01-01 00:00:00

  • OCCUPATIONAL EXPOSURE TO RADON IN DIFFERENT KINDS OF NON-URANIUM MINES.

    abstract::For more accurate assessments of the occupational exposure to radon for miners, the individual monitoring was conducted by using an improved passive integrating (222)Rn monitor. A total of 120 miners in 3 different kinds of mines were monitored throughout a year. The results showed that the individual exposure to rado...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw026

    authors: Fan D,Zhuo W,Zhang Y

    更新日期:2016-09-01 00:00:00

  • Comparison of a CCD and a flat-panel digital system in an Interventional Cardiology Laboratory.

    abstract::We evaluated the performances of angiographic units equipped with a flat-panel (FP) detector and image intensifier (II) charge-coupled device (CCD) in the Interventional Cardiology (IC) Department. Entrance dose rate and dose per image, along with the dose at the II level were measured using 2 mm copper sheets to simu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci746

    authors: Tsapaki V,Kottou S,Kollaros N,Kyriakidis Z,Neofotistou V

    更新日期:2005-01-01 00:00:00

  • Novel Al2O3:C,Mg fluorescent nuclear track detectors for passive neutron dosimetry.

    abstract::The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al(2)O(3):C,Mg) ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm058

    authors: Sykora GJ,Akselrod MS,Salasky M,Marino SA

    更新日期:2007-01-01 00:00:00

  • Occupational exposure to electromagnetic fields in physiotherapy departments.

    abstract::To assess occupational exposure to electromagnetic fields, 11 microwave (MW), 4 short-wave diathermy and 15 magneto therapy devices were analysed in eight physiotherapy departments. Measurements taken at consoles and environmental mapping showed values above European Directive 2004/40/EC and ACGIH exposure limits at a...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm309

    authors: Maccà I,Scapellato ML,Carrieri M,Pasqua di Bisceglie A,Saia B,Bartolucci GB

    更新日期:2008-01-01 00:00:00

  • Simulation of 3D objects into breast tomosynthesis images.

    abstract::Digital breast tomosynthesis is a new three-dimensional (3D) breast-imaging modality that produces images of cross-sectional planes parallel to the detector plane from a limited number of X-ray projections over a limited angular range. Several technical and clinical parameters have not yet been completely optimised. S...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq084

    authors: Shaheen E,Zanca F,Sisini F,Zhang G,Jacobs J,Bosmans H

    更新日期:2010-04-01 00:00:00

  • Assessment of doses and risk due to natural radionuclides in edible biota of Domiasiat, Meghalaya.

    abstract::A radiation dose assessment exercise was carried out for the edible biota Solanum nigrum, Carica papaya, Raphnus sativum and Phaseolus domesticus due to naturally available radionuclides (40)K, (238)U and (232)Th in the Domiasiat area in Meghalaya, India. The concentration of radionuclides in biota and corresponding s...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncr435

    authors: Kumar N,Chaturvedi SS,Jha SK

    更新日期:2012-07-01 00:00:00

  • Indoor concentration of radon, thoron and their progeny around granite regions in the state of Karnataka, India.

    abstract::An extensive studies on the indoor activity concentrations of thoron, radon and their progeny in the granite region in the state of Karnataka, India, has been carried out since, 2007 in the scope of a lung cancer epidemiological study using solid-state nuclear track detector-based double-chamber dosemeters (LR-115, ty...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct243

    authors: Sannappa J,Ningappa C

    更新日期:2014-03-01 00:00:00