Relation between office intraocular pressure and 24-hour intraocular pressure in patients with primary open-angle glaucoma treated with a combination of topical antiglaucoma eye drops.

Abstract:

PURPOSE:To determine the relation between office intraocular pressure (IOP) and 24-hour IOP in patients with primary open-angle glaucoma (POAG) treated with 3 kinds of antiglaucoma eye drops. PATIENTS AND METHODS:Subjects were 42 patients with POAG (71 eyes). All were being treated with 3 different topical antiglaucoma eye drops (latanoprost, beta-blocker, and carbonic anhydrase inhibitor). Twenty-four-hour IOP values were obtained in the sitting position with a Goldmann applanation tonometer at 3-hour intervals. RESULTS:Maximum 24-hour IOP (mean+/-SD) was 19.76+/-5.65 mm Hg, minimum 24-hour IOP was 13.06+/-4.75 mm Hg, mean 24-hour IOP was 16.30+/-4.90 mm Hg, and 24-hour IOP fluctuation was 6.70+/-2.81 mm Hg. Office IOP was 16.23+/-4.58 mm Hg, and office IOP fluctuation was 2.75+/-1.68 mm Hg. There was no significant difference between office IOP and mean 24-hour IOP (P=0.93). There was no correlation between office IOP and 24-hour IOP fluctuation (r=0.15; P=0.25) or between office IOP fluctuation and 24-hour IOP fluctuation (r=0.19; P=0.17). Maximum 24-hour IOP occurred during office hours in 22 eyes (33.8%). The frequency of maximum 24-hour IOP occurring during office hours was significantly less than that of minimum 24-hour IOP (P<0.001). CONCLUSIONS:In POAG patients treated with 3 kinds of antiglaucoma eye drops, office IOP was similar to mean 24-hour IOP. However, it was difficult to estimate 24-hour IOP fluctuation and maximum 24-hour IOP on the basis of office IOP.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Nakakura S,Nomura Y,Ataka S,Shiraki K

doi

10.1097/IJG.0b013e31802ff85f

subject

Has Abstract

pub_date

2007-03-01 00:00:00

pages

201-4

issue

2

eissn

1057-0829

issn

1536-481X

pii

00061198-200703000-00006

journal_volume

16

pub_type

杂志文章
  • Tolerability and Functionality of a Wireless 24-Hour Ocular Telemetry Sensor in African American Glaucoma Patients.

    abstract:PURPOSE:The purpose of the study was to evaluate the tolerability and functionality of a wireless ocular telemetry sensor in African American patients with glaucoma. MATERIALS AND METHODS:In this prospective, observational cohort study, 20 African American patients with primary open angle glaucoma (POAG) were evaluate...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001141

    authors: Marando CM,Mansouri K,Kahook MY,Seibold LK

    更新日期:2019-02-01 00:00:00

  • Risk factors for hyphema after trabeculectomy with mitomycin C.

    abstract:PURPOSE:To determine the risk factors for hyphema after trabeculectomy with mitomycin C (MMC). PATIENTS AND METHODS:In total, 420 patients (420 eyes) with glaucoma who underwent trabeculectomy with MMC between June 1, 2005 and December 31, 2010 at Kumamoto University Hospital, Japan, were retrospectively evaluated. Hy...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3182741c85

    authors: Kojima S,Inatani M,Shobayashi K,Haga A,Inoue T,Tanihara H

    更新日期:2014-06-01 00:00:00

  • Evaluation of the whole-field scotopic retinal sensitivity tester in clinical glaucoma practice.

    abstract::We determined the results of routine whole-field scotopic vision testing in consecutive patients with ocular hypertension or glaucoma who underwent Humphrey automated perimetric testing and optic disc examination. In 39 ocular hypertensive patients we found a mean threshold of 16.7 +/- 7.4 dB and in 61 glaucoma patien...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Stewart WC,Chorak RP,Murrell HP

    更新日期:1994-01-01 00:00:00

  • Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery.

    abstract:PURPOSE:Our purpose was to evaluate the clinical outcomes of the Ex-PRESS miniature glaucoma device placed under a partial-thickness scleral flap as a single procedure or combined with phacoemulsification cataract surgery. METHODS:This was a comparative consecutive case series of 345 eyes: 231 eyes treated with Ex-PRE...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31818fb44e

    authors: Kanner EM,Netland PA,Sarkisian SR Jr,Du H

    更新日期:2009-08-01 00:00:00

  • The value of intraocular pressure asymmetry in diagnosing glaucoma.

    abstract:PURPOSE:To investigate the amount of intraocular pressure (IOP) asymmetry in a large group of ethnically diverse patients with and without glaucoma, and to delineate the risk for glaucoma which increasing amounts of IOP asymmetry confer upon the patient. PATIENTS AND METHODS:Collaborative retrospective study of 326 gl...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318237bfb8

    authors: Williams AL,Gatla S,Leiby BE,Fahmy I,Biswas A,de Barros DM,Ramakrishnan R,Bhardwaj S,Wright C,Dubey S,Lynch JF,Bayer A,Khandelwal R,Ichhpujani P,Gheith M,Siam G,Feldman RM,Henderer JD,Spaeth GL

    更新日期:2013-03-01 00:00:00

  • Expression and regulation of LOXL1 and elastin-related genes in eyes with exfoliation syndrome.

    abstract::Variants in LOXL1 are significantly associated with exfoliation syndrome (XFS), however the impact of the associated variants on disease development is not yet understood. Initially the associated missense changes, R141L and G153D, were considered to be pathogenic alleles. Flipping of the risk allele in certain popula...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000124

    authors: Wiggs JL,Pasquale LR

    更新日期:2014-10-01 00:00:00

  • Mask-induced Artifact Impacts Intraocular Pressure Measurement Using Goldmann Applanation Tonometry.

    abstract:PURPOSE:The coronavirus (COVID-19) pandemic has impacted ophthalmology practices significantly. American Academy of Ophthalmology and Center for Disease Control guidelines suggest mandatory masking of patients and physicians during outpatient visits. We have recently become aware of a mask-induced phenomenon, whereby t...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001746

    authors: Davanian AM,Donahue SP,Mogil RS,Groth SL

    更新日期:2020-12-02 00:00:00

  • Do glaucoma patients use eye drops correctly?

    abstract:PURPOSE:To assess how glaucoma patients use their topical medications. METHODS:142 subjects were tested before an examiner as to how they used their eyedrops. RESULTS:Fifty-six patients (39.4%) used one drop. The number of drops instilled increased with age. The tip of the bottle touched the ocular surface in 78 (54....

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Hosoda M,Yamabayashi S,Furuta M,Tsukahara S

    更新日期:1995-06-01 00:00:00

  • Optic disc hemorrhages and generalized vascular disease.

    abstract:PURPOSE:To study the relationship between optic disc hemorrhages and four different groups of medications used in general vascular disease and diabetes. METHODS:The authors screened citizens of the city of Malmö, Sweden who were between 57 and 79 years old (32,918 subjects), in order to find individuals with undetecte...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00061198-200206000-00011

    authors: Grødum K,Heijl A,Bengtsson B

    更新日期:2002-06-01 00:00:00

  • A Role for Clusterin in Exfoliation Syndrome and Exfoliation Glaucoma?

    abstract::The multifunctional protein clusterin (CLU) is a secreted glycoprotein ubiquitously expressed throughout the body, including in the eye. Its primary function is to act as an extracellular molecular chaperone, preventing the precipitation and aggregation of misfolded extracellular proteins. Clusterin is commonly identi...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000916

    authors: Wiggs JL,Kang JH,Fan B,Levkovitch-Verbin H,Pasquale LR

    更新日期:2018-07-01 00:00:00

  • RETeval Portable Electroretinogram Parameters in Different Severity Stages of Glaucoma.

    abstract::PRéCIS:: Four parameters of the noninvasive, portable RETeval electroretinogram (ERG) system were found to correlate with visual field mean deviation and optical coherence tomography (OCT) thickness parameters, and may therefore be suitable for glaucoma detection. PURPOSE:To investigate the RETeval full-field ERG par...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001509

    authors: Kita Y,Holló G,Saito T,Momota Y,Kita R,Tsunoda K,Hirakata A

    更新日期:2020-07-01 00:00:00

  • Autologous patch graft in tube shunt surgery.

    abstract:PURPOSE:To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. METHODS:A retrospective study of 16 patients (17 eyes) who underwent tube...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Aslanides IM,Spaeth GL,Schmidt CM,Lanzl IM,Gandham SB

    更新日期:1999-10-01 00:00:00

  • Needle revision of filtering blebs.

    abstract::The modern version of trabeculectomy is associated with a very high success rate. As time progresses after surgery, failure of filtration, however, is common, as are problems with filtering blebs such as leaks and dysesthesia. Needle revision of filtering blebs is a useful adjunct to failed, failing, leaking, or dyses...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0b013e318181283e

    authors: Feldman RM,Tabet RR

    更新日期:2008-10-01 00:00:00

  • The effect of laser iridotomy on the anterior segment anatomy of patients with plateau iris configuration.

    abstract:PURPOSE:To determine if laser iridotomy altered the anterior segment anatomy of patients with plateau iris configuration. METHODS:Twenty eyes of 9 female and 1 male patients were imaged using an ultrasound biomicroscope within 19 weeks before and 52 weeks after laser iridotomy. Measurements obtained included the anter...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000151687.96785.03

    authors: Polikoff LA,Chanis RA,Toor A,Ramos-Esteban JC,Fahim MM,Gagliuso DJ,Serle JB

    更新日期:2005-04-01 00:00:00

  • Correlation of automated visual field parameters and peripapillary nerve fiber layer thickness as measured by scanning laser polarimetry.

    abstract:PURPOSE:To correlate Humphrey visual field mean sensitivity and peripapillary nerve fiber layer thickness as measured by scanning laser polarimetry. METHODS:The authors studied 54 eyes of 34 patients who visited a university-based glaucoma clinic and had undergone scanning laser polarimetry and Humphrey perimetry with...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200008000-00001

    authors: Kwon YH,Hong S,Honkanen RA,Alward WL

    更新日期:2000-08-01 00:00:00

  • Parapapillary gamma zone hole.

    abstract:PURPOSE:To describe the appearance of a defect in the parapapillary region of a highly myopic eye. METHODS:During a routine ophthalmologic examination, in a 26-year-old man with a visual acuity of 0.80 and a refractive error of -10.25 D, a dehiscence in the parapapillary region was detected. A choroidal vessel appeare...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000438610.31653.48

    authors: Dai Y,Jonas JB,Ling Z,Sun X

    更新日期:2013-12-01 00:00:00

  • Ethnicity and Deprivation are Associated With Blindness Among Adults With Primary Glaucoma in Nigeria: Results From the Nigeria National Blindness and Visual Impairment Survey.

    abstract:PURPOSE:We explored the risk factors for glaucoma blindness among adults aged 40 years and above with primary glaucoma in Nigeria. PARTICIPANTS AND METHODS:A total of 13,591 participants aged 40 years and above were examined in the Nigeria Blindness Survey; 682 (5.02%; 95 CI, 4.60%-5.47%) had glaucoma by ISGEO's crite...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000487

    authors: Kyari F,Wormald R,Murthy GV,Evans JR,Gilbert CE,Nigeria National Blindness and Visual Impairment Study Group.

    更新日期:2016-10-01 00:00:00

  • Scanning Electron Microscopy Evaluation of an EX-PRESS Mini Glaucoma Shunt After Explantation.

    abstract::We report a case of an explanted stainless steel miniature glaucoma drainage device (EX-PRESS) implanted under a scleral flap for pseudoexfoliation open-angle glaucoma surgical treatment. The glaucoma shunt was implanted in a 75-year-old white man with medically refractive glaucoma. Cataract surgery was performed simu...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000521

    authors: Tognetto D,Cecchini P,D'Aloisio R,Vattovani O,Turco G

    更新日期:2017-01-01 00:00:00

  • Outcomes of Bleb Revision With Mitomycin C After Ex-PRESS Shunt Surgery.

    abstract:PURPOSE:Investigate efficacy and safety of bleb revision using mitomycin C after Ex-PRESS shunt surgery. PATIENTS AND METHODS:We performed chart reviews of 36 consecutive eyes from 34 patients with previous Ex-PRESS shunt surgery who underwent subsequent bleb revision with mitomycin C. The mean follow-up time was 13.5...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000308

    authors: Allan EJ,Jones JM,Ding K,Khaimi MA

    更新日期:2016-04-01 00:00:00

  • Determinants of adherence to glaucoma medical therapy in a long-term patient population.

    abstract:PURPOSE:Estimate patient adherence to glaucoma medications and identify potential determinants of nonadherence. DESIGN:Descriptive study. METHODS:Two hundred patients with open angle glaucoma, ocular hypertension, or glaucoma suspects were interviewed regarding their glaucoma and its treatment and their charts were r...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181815421

    authors: Djafari F,Lesk MR,Harasymowycz PJ,Desjardins D,Lachaine J

    更新日期:2009-03-01 00:00:00

  • Optic nerve head circulation after topical calcium channel blocker.

    abstract:PURPOSE:Our purpose was to investigate the effects of the calcium channel blocker verapamil on intraocular pressure and blood circulation in the human optic nerve head. METHODS:The effects of three different concentrations of topical verapamil (0.063%, 0.125%, and 0.25%) on intraocular pressure and optic nerve head ca...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Netland PA,Feke GT,Konno S,Goger DG,Fujio N

    更新日期:1996-06-01 00:00:00

  • Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data: prospective analysis of biophysical parameters in tertiary glaucoma practice populations.

    abstract:PURPOSE:To determine the correlation of central corneal thickness (CCT) to Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT, PASCAL), and to glaucoma stage as assessed by cup-to-disc ratio (CDR). DESIGN:Prospective, cross-sectional tricenter observation study. PATIENTS AND METHODS:From three gl...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00061198-200604000-00003

    authors: Kniestedt C,Lin S,Choe J,Nee M,Bostrom A,Stürmer J,Stamper RL

    更新日期:2006-04-01 00:00:00

  • The Glaucoma Italian Pediatric Study (GIPSy): 1-Year Results.

    abstract:PURPOSE:To investigate the efficacy and safety of a treatment strategy with latanoprost and dorzolamide in primary pediatric glaucoma patients partially responsive to surgery. PATIENTS AND METHODS:Children with primary pediatric glaucoma having postsurgical untreated intraocular pressure (IOP) between 22 and 26 mm Hg ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/IJG.0000000000000773

    authors: Quaranta L,Biagioli E,Riva I,Galli F,Poli D,Rulli E,Katsanos A,Longo A,Uva MG,Torri V,Weinreb RN

    更新日期:2017-11-01 00:00:00

  • Characteristics of Patients Receiving Treatment Who Deny A Diagnosis Glaucoma or Elevated Intraocular Pressure in the United States.

    abstract:PURPOSE:The purpose of this study was to determine the proportion of patients in the US population who are receiving long-term intraocular pressure (IOP)-lowering medication, but, deny having a diagnosis of glaucoma or elevated IOP. MATERIALS AND METHODS:The National Health and Nutrition Examination Survey (NHANES) is...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001035

    authors: Lowry EA,Mansberger SL

    更新日期:2018-11-01 00:00:00

  • Comparison of ICare rebound tonometer with noncontact tonometer in healthy children.

    abstract:PURPOSE:To evaluate the effectiveness of using a noncontact tonometer (NCT) versus a rebound tonometer (ICare) when measuring the intraocular pressure (IOP) in healthy children. DESIGN:Prospective observational study. METHODS:A total of 180 (96 males and 84 females) healthy children, aged 6 months to 15 years, were r...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181d12dc4

    authors: Kageyama M,Hirooka K,Baba T,Shiraga F

    更新日期:2011-01-01 00:00:00

  • Fluctuation of Bacteria on Bleb Surface After Trabeculectomy With Adjunctive Mitomycin C.

    abstract:PURPOSE:To determine whether the bacterial and floral patterns on the bleb surface are affected by the season in eyes that had undergone trabeculectomy with adjunctive mitomycin C. PATIENTS AND METHODS:Forty-four glaucoma patients who had an avascular or a hypovascular cystic filtering bleb were studied. Swabs of the ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000305

    authors: Takahashi N,Sawada A,Mochizuki K,Katada T,Yamamoto T

    更新日期:2016-05-01 00:00:00

  • Comparative study of the efficacy of argon laser trabeculoplasty for exfoliation and primary open-angle glaucoma.

    abstract:PURPOSE:To investigate the efficacy of argon laser trabeculoplasty (ALT) for the treatment of primary open-angle glaucoma (POAG) and of glaucoma associated with exfoliation syndrome (EXF). METHODS:Review of > 200 charts from patients treated with ALT between 1981 and 1987 identified 66 POAG and 29 EXF eyes that underw...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Threlkeld AB,Hertzmark E,Sturm RT,Epstein DL,Allingham RR

    更新日期:1996-10-01 00:00:00

  • Evaluating the Laser Output of the Micropulse P3 Laser Delivery Device Following Repeated Use.

    abstract:PRECIS:Repeated use of the Micropulse P3 (MP3) probe during micropulse transscleral cyclophotocoagulation is associated with an increase in laser output over time. PURPOSE:The purpose of this study was to examine the laser efficacy of the MP3 probe following repeated use. METHODS:This was an observational study carri...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001277

    authors: Lun K,Suwandono ME,Koh V,Chew PT

    更新日期:2019-08-01 00:00:00

  • Continuous monitoring of intraocular pressure: rationale and progress toward a clinical device.

    abstract::Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0b013e3181862490

    authors: Sit AJ

    更新日期:2009-04-01 00:00:00

  • Micropulse Trans-scleral Cyclophotocoagulation in Patients With Glaucoma: 1- and 2-Year Treatment Outcomes.

    abstract::PRéCIS:: Micropulse trans-scleral cyclophotocoagulation (TSCPC) is an effective and safe IOP-lowering treatment for patients with primary or secondary glaucoma. PURPOSE:To investigate the 1-year and 2-year effect on intraocular pressure (IOP) and safety profile of micropulse TSCPC in patients with glaucoma. METHODS:...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001552

    authors: de Crom RMPC,Slangen CGMM,Kujovic-Aleksov S,Webers CAB,Berendschot TTJM,Beckers HJM

    更新日期:2020-09-01 00:00:00