Comparison of effective doses from various monoenergetic particles based on the stylised and the VIP-Man tomographic models.

Abstract:

:This study compares the effective doses from a MIRD-type stylised model with those derived from the scaled-down version of the tomographic VIP-Man model for photon, electron, neutron and proton beams. The effective dose results from these two models show that they differ from each other within approximately 10% for common high-energy photon beams, within approximately 16% for neutrons, and within approximately 4% for high-energy proton beams. However, for low-energy protons and common electron beams, the effective doses can be different in >100%. It is concluded that the use of a single tomographic models will not improve the operational radiation protection dosimetry involving external beam exposures.

journal_name

Radiat Prot Dosimetry

authors

Xu XG,Chao TC,Bozkurt A

doi

10.1093/rpd/nci116

keywords:

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

530-5

issue

1-4

eissn

0144-8420

issn

1742-3406

pii

115/1-4/530

journal_volume

115

pub_type

杂志文章
  • Radiation dose management in CT, SPECT/CT and PET/CT techniques.

    abstract::New imaging technologies utilising X rays and radiopharmaceuticals are continuously under development. The benefit of computed tomography (CT) has been so dramatic that there is a tendency to overuse it and not to place enough efforts into optimisation of the technique. It is also now more and more common to combine t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncr261

    authors: Mattsson S,Söderberg M

    更新日期:2011-09-01 00:00:00

  • High background radiation areas: the case of Villar de la Yegua village (Spain).

    abstract::The starting point of the Spanish experience in the study of High Background Radiation Areas is the development of a nationwide indoor radon survey carried out in 1988. This campaign, belonging to the first Spanish Radon Framework, consisted of approximately 2000 indoor radon measurements which represented a valuable ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncm196

    authors: Sáinz C,Quindós LS,Fernández PL,Gómez J,Fuente I,Quindós L,Matarranz JL

    更新日期:2007-01-01 00:00:00

  • Validation of efficiency tracing and zero detection threshold techniques using liquid scintillation analyser TriCarb.

    abstract::Efficiency tracing with unquenched 14C and zero detection threshold with unquenched 3H as tracers are practical and simple techniques which have been implemented to quantify the activity of various beta emitters using liquid scintillation analyser. These techniques are used to study the influence of quench level on ac...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq495

    authors: Reddy PJ,Bhade SP,Babu DA,Sharma DN

    更新日期:2011-11-01 00:00:00

  • Radiation protection at low energy proton accelerators.

    abstract::A sample is provided of the radiological safety issues particular to low energy proton accelerators. 'Low' energy in this context is taken to mean proton energies of less than about 1 GeV. Many of the radiation issues are common to all particle accelerators. Here, those issues are addressed that may require perhaps no...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/oxfordjournals.rpd.a006619

    authors: Moritz LE

    更新日期:2001-01-01 00:00:00

  • Evaluation Of Organ Dose Based On Patient Data In East Asian Descent Pediatric Head Ct Examinations.

    abstract::The purpose of this study was to investigate other indices estimating absorbed dose for eye lens and brain, using clinical images of East Asian pediatric patients. We simulated head computed tomography (CT ) examinations in 104 pediatric patients. Effective diameter (deff) and water equivalent diameter (dw) were measu...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncaa200

    authors: Kawamoto K,Fukushima Y,Matsuda A,Nakata M

    更新日期:2020-12-17 00:00:00

  • Considerations and preliminary design of patient exposure registry.

    abstract::To aid in protecting patients from unnecessary exposures and to reduce radiation burdens to the public, a system for tracking a patient's medical exposure history and related radiation doses would be a useful tool. A patient-centred exposure registry, the Patient Exposure Registry (PER), is a mechanism that provides t...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncq280

    authors: Chen J,Moir D,Cornett J

    更新日期:2010-12-01 00:00:00

  • PUBLIC HEALTH ENGLAND-CENTRE FOR RADIATION, CHEMICAL AND ENVIRONMENTAL HAZARDS (PHE-CRCE) EXTERNAL EXPERT EXPERIENCE IN THE JOINT EXTERNAL EVALUATION (JEE) MISSION FOR THE RADIATION EMERGENCIES TECHNICAL AREA.

    abstract::From August 2016 to June 2017, the Public Health England-Centre for Radiation Chemical and Environmental Hazards (PHE-CRCE), collaborating centre of the WHO, through its Radiation Hazards and Emergencies Department Emergency Response Group has successfully supported five WHO Joint External Evaluation (JEE) missions in...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncy142

    authors: de Ruvo A,Cox D

    更新日期:2018-12-01 00:00:00

  • Radiation-induced non-targeted effects: some open questions.

    abstract::The existence of non-targeted effects (NTEs) of radiation (genomic instability and bystander effects) has been generally accepted for >20 y; however, there is research, which was largely ignored going back to 1915 reporting these effects. Despite today's general acceptance of the phenomenon of NTE, there is little agr...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,评审

    doi:10.1093/rpd/ncv155

    authors: Mothersill C,Seymour C

    更新日期:2015-09-01 00:00:00

  • Physical image quality comparison of four types of digital detector for chest radiology.

    abstract::Image quality for similar exposure conditions has been compared for two computed radiography (CR) systems (needle-based and conventional storage phosphor) and two flat-panel (DR) systems from different manufacturers mainly devoted to chest radiology. Image quality was assessed with a contrast-detail object and acrylic...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncn026

    authors: Fernandez JM,Ordiales JM,Guibelalde E,Prieto C,Vano E

    更新日期:2008-01-01 00:00:00

  • Reconstruction of cluster distributions at 100% detection efficiency for a track-nanodosimetric counter through a Bayesian analysis.

    abstract::A Bayesian unfolding has been applied to ionisation distributions due to 5.4 MeV alpha particles in a 20-nm site obtained using Monte Carlo simulations, taking into account different detection efficiency conditions. The ideal case of a target volume with uniform efficiency has been investigated to study the dependence...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch143

    authors: De Nardo L,Lesimple M,Canella S,Grosswendt B

    更新日期:2004-01-01 00:00:00

  • Measured proton sensitivities of bubble detectors.

    abstract::The neutron dose equivalent in aircraft is measured using commercial bubble detectors, but at high altitudes there are not only neutrons but also protons. Bubble detectors have been used because they are considered not to be sensitive to protons, but this has been the subject of only a few studies. In this study, by i...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch330

    authors: Takada M,Kitamura H,Koi T,Nakamura T,Fujitaka K

    更新日期:2004-01-01 00:00:00

  • A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    abstract::Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly c...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw266

    authors: Bonin A,Tsilanizara A

    更新日期:2017-06-01 00:00:00

  • Design and manufacturing of anthropomorphic thyroid-neck phantom for use in nuclear medicine centres in Chile.

    abstract::Anthropomorphic phantoms are used in nuclear medicine for imaging quality control, calibration of gamma spectrometry system for the study of internal contamination with radionuclides and for internal dosimetric studies. These are constructed of materials that have radiation attenuation coefficients similar to those of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu022

    authors: Hermosilla A,Díaz Londoño G,García M,Ruíz F,Andrade P,Pérez A

    更新日期:2014-12-01 00:00:00

  • A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    abstract::To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tis...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx024

    authors: Moslehi A,Raisali G

    更新日期:2017-11-01 00:00:00

  • Biomarkers specific to densely-ionising (high LET) radiations.

    abstract::There have been several suggestions of biomarkers that are specific to high LET radiation. Such a biomarker could significantly increase the power of epidemiological studies of individuals exposed to densely-ionising radiations such as alpha particles (e.g. radon, plutonium workers, individuals exposed to depleted ura...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006640

    authors: Brenner DJ,Okladnikova N,Hande P,Burak L,Geard CR,Azizova T

    更新日期:2001-01-01 00:00:00

  • Optically stimulated luminescence signals of polymineral fine grains in the JSC Mars-1 soil simulant sample.

    abstract::The results of various experiments which characterise the optically stimulated luminescence (OSL) signals from polymineral fine grains of a Martian soil simulant sample (JSC Mars-1) are presented. The blue-green stimulated luminescence signal has greater thermal stability than the infrared stimulated luminescence sign...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a005994

    authors: Banerjee D,Blair M,Lepper K,McKeever SW

    更新日期:2002-01-01 00:00:00

  • A micro-gap, air-filled ionisation chamber as a detector for criticality accident dosimetry.

    abstract::A micro-gap air-filled ionisation chamber was designed for criticality dosimetry. The special feature of the chamber is its very small gap between electrodes of only 0.3 mm. This prevents ion recombination at high dose rates and minimises the influence of gas on secondary particles spectrum. The electrodes are made of...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct323

    authors: Murawski Ł,Zielczyński M,Golnik N,Gryziński MA

    更新日期:2014-10-01 00:00:00

  • Protection from radon exposure at home and at work in the directive 2013/59/Euratom.

    abstract::In recent years, international organisations involved in radiation protection and public health have produced new guidance, recommendations and requirements aiming better protection from radon exposure. These organisations have often worked in close collaboration in order to facilitate the establishment of harmonised ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncu101

    authors: Bochicchio F

    更新日期:2014-07-01 00:00:00

  • Narrow beam dosimetry for high energy hadrons and electrons.

    abstract::Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10-400 GeV. The target organs considered were right eye, thyroid,...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006556

    authors: Pelliccioni M,Silari M,Ulrici L

    更新日期:2001-01-01 00:00:00

  • CAN HALF VALUE LAYER MEASUREMENTS BE USED TOGETHER WITH THE EFFECTIVE ENERGY TO OBTAIN CONVERSION COEFFICIENTS FOR X-RAY SPECTRA?

    abstract::Conversion coefficients are a substantial vehicle in practical radiation protection to determine the dose (rate) of a given radiation field. According to ICRU report 57, their values shall be obtained by means of spectrometry. This is, however, a time-consuming complicated procedure that cannot be performed by all dos...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncw003

    authors: Behnke B,Hupe O

    更新日期:2017-04-15 00:00:00

  • Ethical issues in radiology: perspectives from the Christian tradition.

    abstract::The Christian ethical tradition introduces a number of key values into the clinical context. Moreover, although some denominational differences exist, these are essentially differences of emphasis rather than of substance. Among the central values which the Christian tradition promotes are: the dignity of the person, ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp044

    authors: Hogan L

    更新日期:2009-07-01 00:00:00

  • Investigation of the neutron contribution in the 6 MeV to 7 MeV high energy photon reference field.

    abstract::In order to provide reference fields for the ionising radiation, PTB operates the ion accelerator facility. Referring to high energy photons, reference fields according to International Organization for Standardization 4037 series are produced. The neutron component of the 6-7 MeV photon field (R-F), which is produced...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncp101

    authors: Röttger S,Heiske A,Nolte R

    更新日期:2009-07-01 00:00:00

  • CHARACTERIZATION OF FLUORESCENT NUCLEAR TRACK DETECTORS AS CRITICALITY DOSIMETERS II.

    abstract::Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum n...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx236

    authors: Harrison J,Moreno B,Van Hoey O,Mihailescu LC,Vanhavere F,Million M,Fomenko V,Akselrod M

    更新日期:2018-08-01 00:00:00

  • A simple physical phantom for an intercomparison exercise on 241Am activity determination in the skull.

    abstract::A simple hemispherical phantom has been designed and prepared for the EURADOS intercomparison exercise on (241)Am activity determination in the skull (2011-13). The phantom consists of three parts that substitute bone and soft tissues. (241)Am is deposited on the surfaces of the bone-substituting part. The design and ...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nct213

    authors: Vrba T,Malátová I,Fojtík P,Fülöp M,Ragan P

    更新日期:2014-01-01 00:00:00

  • ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.

    abstract::The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protect...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nci702

    authors: Vano E,Faulkner K

    更新日期:2005-01-01 00:00:00

  • Modelling the 137Cs ingestion dose from consumption of marine fish in Hong Kong.

    abstract::This paper presents a compartmental model for estimating the ingestion dose, due to 137Cs, arising from the consumption of marine fish in Hong Kong. 137Cs is one of the more important radionuclides released in routine liquid effluents discharged from the Guangdong Nuclear Power Station at Daya Bay, which began commerc...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/oxfordjournals.rpd.a006710

    authors: Poon CB,Au SM

    更新日期:2002-01-01 00:00:00

  • A minimally invasive method to evaluate 131I kinetics in blood.

    abstract::The dose limiting factor for 131I therapy in patients with thyroid cancer is myelotoxicity, thus an accurate determination of radioiodine activity in the red marrow is of paramount importance. The reference method for red marrow dosimetry in radiometabolic therapy is based on the measurement of radioiodine kinetics, p...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/nch041

    authors: Traino AC,Di Martino F,Boni G,Mariani G,Lazzeri M

    更新日期:2004-01-01 00:00:00

  • Aircraft crew radiation workplaces: comparison of measured and calculated ambient dose equivalent rate data using the EURADOS in-flight radiation data base.

    abstract::In May 2000, the chairman of the European Radiation Dosimetry Group (EURADOS) invited a number of experts with experience of cosmic radiation dosimetry to form a working group (WG 5) on aircraft crew dosimetry. Three observers from the Article 31 Group of Experts as well as one observer from the Joint Aviation Authori...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncl029

    authors: Beck P,Bartlett D,Lindborg L,McAulay I,Schnuer K,Schraube H,Spurny F

    更新日期:2006-01-01 00:00:00

  • Studies of patient doses in interventional radiological examinations.

    abstract::In Russia, especially in big cities like St. Petersburg, the annual number of interventional radiological (IR) examinations for both diagnostic and treatment purposes is increasing continuously. However, IR examinations might involve high patient doses and even the risk of skin injures that should be prevented. In thi...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章,多中心研究

    doi:10.1093/rpd/ncq021

    authors: Sarycheva S,Golikov V,Kalnicky S

    更新日期:2010-04-01 00:00:00

  • AEROSOL SIZE DISTRIBUTION IN URANIUM PROCESSING FACILITY FOR APPLICATION IN THE ASSESSMENT OF INTERNAL EXPOSURE.

    abstract::In circumstances of inhalation exposure the radiotoxicity of radionuclide depends on the fractional deposition of inhaled activity, which is governed by the aerodynamic characteristics of the particles. Although International Commission on Radiological Protection (ICRP) provides default size distribution parameters fo...

    journal_title:Radiation protection dosimetry

    pub_type: 杂志文章

    doi:10.1093/rpd/ncx231

    authors: Shailesh M,Das T,Prabhat M,Kolekar RV,Gopalakrishnan RK

    更新日期:2018-04-01 00:00:00