Abstract:
:We compared two adaptive procedures for fitting a multi-channel compression hearing aid. "Camadapt" uses judgements of the loudness of speech stimuli and the tonal quality of music stimuli. "Eartuner" uses judgements of the loudness and clarity of speech stimuli with differing spectral characteristics. Sixteen new users of hearing aids were fitted unilaterally, using each procedure. The fittings were assigned to Programs 1 and 2 in the aid, in a counter-balanced order. Subjects kept a diary of their experiences with each program in everyday life. Following 2-4 weeks of experience, they filled in the APHAB and other questionnaires and were re-fitted using both procedures. Camadapt generally led to higher low-level gains and lower high-level gains than Eartuner. Gains recommended by the procedures did not change following experience. Eight subjects preferred the Camadapt fitting and eight preferred the Eartuner fitting. Most subjects gave high overall satisfaction ratings for both procedures. Test-retest reliability was better for Eartuner than for Camadapt. Preference for the Camadapt fitting was associated with slightly better speech communication with Camadapt, while preference for the Eartuner fitting was associated with fewer problems with aversion for that procedure.
journal_name
Int J Audioljournal_title
International journal of audiologyauthors
Moore BC,Marriage J,Alcántara J,Glasberg BRdoi
10.1080/14992020500060198keywords:
subject
Has Abstractpub_date
2005-06-01 00:00:00pages
345-57issue
6eissn
1499-2027issn
1708-8186journal_volume
44pub_type
杂志文章abstract::Tympanometry using 226 Hz, 678 Hz, and 1000 Hz probe tones was undertaken on two groups of babies, age 2 to 21 weeks. A group of 104 babies with normal ABR thresholds or TEOAEs were compared with a second group of 107 babies who had evidence of temporary conductive hearing loss based on the findings of a test battery,...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020600690951
更新日期:2006-07-01 00:00:00
abstract::One limitation with the Bone Anchored Hearing Aid (Baha) is too poor amplification for patients with moderate to severe sensorineural hearing losses. Therefore, we investigated if bone conducted (BC) sound transmission improves when the stimulation approaches the cochlea. Also the influence from the squamosal suture o...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020802311216
更新日期:2008-12-01 00:00:00
abstract::The efferent auditory pathway is known to alter the cochlear electrical properties, at low stimulus levels. This study aims to identify the effect of activation of the efferent auditory pathway through contralateral wide- and narrow-band noise at high sound levels. Acoustical reflex threshold and acoustical reflex amp...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992020209090405
更新日期:2002-03-01 00:00:00
abstract::This is the second paper in a series of two papers comparing auditory measures in depressed and non-depressed individuals. In this paper, we describe the auditory brainstem responses (ABRs), auditory late responses (ALRs) and behavioral speech measures obtained from the same set of 36 individuals as in our previous pa...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020400050064
更新日期:2004-10-01 00:00:00
abstract:OBJECTIVE:Recently, the digit triplet test was shown to be a sensitive speech-in-noise test for early high-frequency hearing loss in noise-exposed workers. This study investigates if a further improvement is achieved when using a closed set of consonant-vowel-consonant (CVC) speech items with the same vowel, and/or a l...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2013.849361
更新日期:2014-03-01 00:00:00
abstract::The dynamics of contralateral acoustic suppression were studied using real time (millisecond resolution) distortion product otoacoustic emissions (DPOAEs) in chinchillas and humans. Latency of DPOAE suppression onset is 26 ms in chinchillas and 45 ms in humans. After onset, suppression builds over time before tending ...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020400029996
更新日期:2005-02-01 00:00:00
abstract::The goal of this study was to examine the relationships between scores obtained from measures of speech perception and language in a group of young children with hearing loss (HL). Eighteen children (mean age = 4.3 years) and their mothers participated in this study. Speech perception was measured using the online imi...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020802607423
更新日期:2009-05-01 00:00:00
abstract::Hearing loss in mucopolysaccharidosis is usually both conductive and sensorineural. The conductive component is attributable to serous otitis media secondary to dysfunction of the eustachian tube and chronic thickening of the mucosa of the middle ear. The conductive component may persist after myringotomy and insertio...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020600975287
更新日期:2007-02-01 00:00:00
abstract:OBJECTIVE:Sudden sensorineural hearing loss (SSHL) is characterized by a rapid loss of hearing, most often of cochlear origin. Very little attention has been paid in the literature to quality of life (QoL), psychosocial consequences and audiological rehabilitation after SSHL. DESIGN:We studied how level of hearing los...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2010.533705
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVES:To introduce the Italian adaptation of the STARR test based on a roving-level adaptive method to mimic challenging real-life listening conditions for use in people with auditory prostheses. DESIGN:Normative data were collected and interlist-variability, as well as learning effects, were investigated using a...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2015.1124296
更新日期:2016-01-01 00:00:00
abstract::Objective: This systematic review investigated if hearing aid use was associated with acute improvements in cognitive function in hearing-impaired adults. Design: The review question and inclusion/exclusion criteria were designed using the Population, Intervention, Control, Outcomes, and Study design (PICOS) mnemonic....
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992027.2019.1594414
更新日期:2019-08-01 00:00:00
abstract::Objective: To clarify the distinction between Auditory Processing Disorder (APD) and Attention Deficit Disorder (ADD) using the CHC Model.Design: A cross-sectional study compared responses of caregivers about their children's behaviour to identify characteristics of APD (CHC Model) and ADD (DSM-5).Study Sample: Caregi...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992027.2019.1682199
更新日期:2020-03-01 00:00:00
abstract::Confirmation of the conditions of the ossicles is essential for tympanoplasty. However, at present, ossicular mobility is experimentally estimated with palpation by a surgeon, and the results depend on the surgeon's skill. In this study, a new apparatus for quantitatively measuring ossicular mobility was developed. Wi...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020500377899
更新日期:2006-02-01 00:00:00
abstract::Clinical procedures related to patients with Alzheimer's Disease (AD) largely fail to address the patient's hearing. Given the challenges of this population, unconventional indicators of treatment efficacy may be required. Palmer et al (1999) reported on caregiver-tracked behaviors as outcome measures for hearing aid ...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020400022637
更新日期:2005-01-01 00:00:00
abstract::The purpose of this study was to determine and to compare the overall intelligibility, articulation, resonance, and voice characteristics in children using cochlear implants (CI) and children using conventional hearing aids (HA). Nine prelingually deaf children using CI and six children with a prelingual severe hearin...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020500189146
更新日期:2005-08-01 00:00:00
abstract:OBJECTIVE:Deaf children with cochlear implants (CIs) show poorer verbal working memory compared to normal-hearing (NH) peers, but little is known about their verbal learning and memory (VLM) processes involving multi-trial free recall. DESIGN:Children with CIs were compared to NH peers using the California Verbal Lear...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992027.2018.1481538
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVE:To use the self-determination theory of motivation to investigate whether different forms of motivation were associated with adults' decisions whether or not to adopt hearing aids. DESIGN:A quantitative approach was used in this cohort study. Participants completed the treatment self-regulation questionnaire...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2015.1007213
更新日期:2015-07-01 00:00:00
abstract::Objective: To compare the temporal processing skills and speech in noise perception of hearing-impaired individuals through channel free and multichannel hearing aids.Design: A quasi-experimental study.Study sample: Twenty-one participants with sensory neural hearing loss were involved in the study. They were subjecte...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992027.2019.1660005
更新日期:2019-12-01 00:00:00
abstract::The study investigated the mental health and other characteristics of people with acquired profound hearing loss (APHL) and contrasted this group with acquired hearing loss (AHL) in general. A survey was completed over the internet by 95 adults and by 27 people who had attended a one-week course of rehabilitation. The...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020600957335
更新日期:2006-12-01 00:00:00
abstract:OBJECTIVE:A significant relationship between dietary nutrient intake and susceptibility to acquired hearing loss is emerging. Variability in the outcomes across studies is likely related to differences in the specific metrics used to quantify nutrient intake and hearing status. Most studies have used single nutrient an...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2013.780133
更新日期:2013-06-01 00:00:00
abstract:OBJECTIVE:To design a test battery and conduct a proof-of-concept experiment of a test method that can be used to measure the detection performance afforded by military advanced hearing protection devices (HPDs) and tactical communication and protective systems (TCAPS). DESIGN:The detection test was conducted with eac...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992027.2016.1256505
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVE:Evaluation of the effectiveness of imaging and genetic testing, and establishment of a cost-effective diagnostic protocol for the etiologic diagnosis of sensorineural hearing loss (SNHL) in Brazil. DESIGN:Prospective cohort study. STUDY SAMPLE:Analysis of 100 unrelated Brazilian patients with severe to prof...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2013.817689
更新日期:2013-11-01 00:00:00
abstract:OBJECTIVE:Music perception and appraisal are generally poor in cochlear implant recipients. Simple musical structures, lyrics that are easy to follow, and clear rhythm/beat have been reported among the top factors to enhance music enjoyment. The present study investigated the preference for modified relative instrument...
journal_title:International journal of audiology
pub_type: 临床试验,杂志文章
doi:10.3109/14992027.2013.873955
更新日期:2014-05-01 00:00:00
abstract:OBJECTIVE:To describe getting used to hearing aids from the perspective of adult hearing-aid users. DESIGN:Three focus group discussions were carried out. A topic guide and discussion exercises were used to elicit views on getting used to hearing aids. Discussion was audio recorded, transcribed verbatim, and subjected...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2014.938782
更新日期:2014-12-01 00:00:00
abstract::This investigation examined how age and test condition affect one's ability to comprehend discourse passages, and determined whether age and test condition affect discourse comprehension and closed-set sentence recognition in a similar way. Young and older adults were tested with closed-set sentences from the newly-cr...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020802301662
更新日期:2008-11-01 00:00:00
abstract:OBJECTIVE:This study aimed to explore the perspectives of caregivers regarding the information and support they received following diagnosis of their child's hearing loss. DESIGN:A mixed methods explanatory sequential design was conducted. STUDY SAMPLE:A total of 445 caregivers of children completed a written survey,...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992027.2017.1301683
更新日期:2018-05-01 00:00:00
abstract::The aim of this study was to compare auditory functions and to analyse the prevalence of hearing impairment and the relationship of self-reported hearing disability with audiometric test results among 75-year-old people in three Nordic localities. The representative samples came from Glostrup, Denmark (n = 571), Göteb...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992020500189112
更新日期:2005-09-01 00:00:00
abstract:OBJECTIVE:Inflammaging, a state of chronic inflammation in the elderly, is now thought to be a key element of the ageing process and contributor to age-related disease. In a previously published study, we identified a significant association between inflammation levels and severity of presbycusis among individuals aged...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2014.891057
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVE:In many low- and middle-income countries, the availability of hearing technology is limited, with few options for hearing aid repairs. Minimising moisture damage to hearing aid electronics improves function and longevity; however, desiccants that absorb moisture from hearing aid components are unavailable in ...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.1080/14992027.2016.1253877
更新日期:2017-04-01 00:00:00
abstract::Audiometric measurements through a hearing aid ('in-situ') may facilitate provision of hearing services where these are limited. This study investigated the validity and reliability of in-situ air conduction hearing thresholds measured with closed and open domes relative to thresholds measured with insert earphones, a...
journal_title:International journal of audiology
pub_type: 杂志文章
doi:10.3109/14992027.2010.503664
更新日期:2010-12-01 00:00:00