Identification of the portal vein: wedge hepatic venography with CO2 or iodinated contrast medium.

Abstract:

RATIONALE AND OBJECTIVES:The purpose of this study was to evaluate the utility of CO2 versus iodinated contrast medium for wedge hepatic venography in identifying portal vein anatomy during transjugular intrahepatic portosystemic shunt (TIPS) procedures. MATERIALS AND METHODS:Wedge hepatic venograms obtained with CO2 or iodinated contrast medium and direct portograms of 43 patients undergoing TIPS procedures were analyzed retrospectively. Wedge venography was performed in 23 patients with CO2 and in 21 with iodinated contrast medium; direct portography was subsequently performed in 42 of 44 patients with iodinated contrast medium and in one with CO2. All cases were reviewed systematically to compare portal vein anatomy and completeness of anatomic identification between direct portography and wedge venography, and the results with CO2 were compared to those with iodinated contrast material. RESULTS:On the basis of opacification of the main portal trunk, branches, or both, the portal vein appearance (definition of the portal bifurcation) was good to excellent in 21 of 23 patients imaged with CO2 but in only two of 20 patients imaged with iodinated contrast medium. Wedge venograms agreed with direct portograms in 91% (21 of 23) of the CO2 cases and in 10% (two of 20) of the iodinated contrast medium cases. The two patients with poor opacification using CO2 had poor delineation of the main portal trunk, branches, and varices. TIPS could not be created in three patients, In two, abnormal morphology was identified at CO2 venography; in the third, wedge venography was not performed. CONCLUSION:Wedge hepatic venography with CO2 compared with iodinated contrast medium has a substantially higher likelihood of correctly and completely identifying the location and anatomy of the portal vein.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Yang L,Bettmann MA

doi

10.1016/S1076-6332(99)80487-5

keywords:

subject

Has Abstract

pub_date

1999-02-01 00:00:00

pages

89-93

issue

2

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(99)80487-5

journal_volume

6

pub_type

杂志文章
  • CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the appropriate body mass index (BMI)-dependent noise index (NI) setting in computed tomography pulmonary angiography (CTPA) with automatic tube current modulation with adaptive statistical iterative reconstruction (ASiR). MATERIALS AND METHODS:A total of 480 pati...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.07.018

    authors: Zhao YX,Zuo ZW,Suo HN,Wang JN,Chang J

    更新日期:2016-12-01 00:00:00

  • Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low, intermediate, and high cardiovascular risk.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to compare the diagnostic accuracy of 64-slice computed tomographic coronary angiography (CTCA) in groups of patients with low, intermediate, and high risk for coronary artery disease (CAD) events. MATERIALS AND METHODS:The institutional review board approved this stu...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.12.008

    authors: Husmann L,Schepis T,Scheffel H,Gaemperli O,Leschka S,Valenta I,Koepfli P,Desbiolles L,Stolzmann P,Marincek B,Alkadhi H,Kaufmann PA

    更新日期:2008-04-01 00:00:00

  • How good is the ACR accreditation phantom for assessing image quality in digital mammography?

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to evaluate the American College of Radiology (ACR) accreditation phantom for assessing image quality in digital mammography. MATERIALS AND METHODS:Digital images were obtained of an ACR accreditation phantom at varying mAs (constant kVp) and varying kVp (constant...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80345-8

    authors: Huda W,Sajewicz AM,Ogden KM,Scalzetti EM,Dance DR

    更新日期:2002-07-01 00:00:00

  • Accuracy of Cyst Versus Solid Diagnosis in the Breast Using Quantitative Transmission (QT) Ultrasound.

    abstract:RATIONAL AND OBJECTIVES:This study aims to evaluate the diagnostic utility of breast imaging using transmission ultrasound. We present readers' accuracy in determining whether a breast lesion is a cyst versus a solid using transmission ultrasound as an adjunct to mammography. MATERIALS AND METHODS:This retrospective m...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.03.024

    authors: Iuanow E,Smith K,Obuchowski NA,Bullen J,Klock JC

    更新日期:2017-09-01 00:00:00

  • Identification of noncalcified plaque in young persons with diabetes: an opportunity for early primary prevention of coronary artery disease identified with low-dose coronary computed tomographic angiography.

    abstract:PURPOSE:Coronary computed tomographic angiography (CTA) is a valuable tool for assessing coronary artery disease (CAD). Although statin use is widely recommended for persons with diabetes older than age 40, little is known about the presence and severity of CAD in younger patients with diabetes mellitus (DM). We evalua...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.03.013

    authors: Madaj PM,Budoff MJ,Li D,Tayek JA,Karlsberg RP,Karpman HL

    更新日期:2012-07-01 00:00:00

  • A review of technical advances in interventional magnetic resonance imaging.

    abstract::Initial research in the development of interventional magnetic resonance (MR) imaging in the late 1980s and early to mid-1990s focused on pulse sequences, devices, and clinical applications. This focus was largely a result of the limited number of areas in which the academic research community leading the development ...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2005.06.003

    authors: Elgort DR,Duerk JL

    更新日期:2005-09-01 00:00:00

  • Conspicuity of Screen-Detected Malignancies on Full Field Digital Mammography vs. Synthetic Mammography.

    abstract:RATIONALE AND OBJECTIVES:To evaluate conspicuity of screen-detected cancers on two-dimensional synthetic mammography (SM) reconstructed from digital breast tomosynthesis (DBT) compared to two-dimensional full field digital mammography (FFDM). MATERIALS AND METHODS:IRB-approved retrospective review of consecutive scree...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.06.008

    authors: Chikarmane SA,Yeh ED,Wang A,Ratanaprasatporn L,Giess CS

    更新日期:2020-06-01 00:00:00

  • A preliminary report on the role of spatial frequency analysis in the perception of breast cancers missed at mammography screening.

    abstract:RATIONALE AND OBJECTIVES:Because several factors are involved in cancer detection, a malignant lesion that is visible on a mammogram will not necessarily be reported by the radiologist reading the case. Indeed, a significant fraction of screening-detected cancers are visible in retrospect, and were perceived by the rad...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.04.015

    authors: Mello-Thoms C,Chapman B

    更新日期:2004-08-01 00:00:00

  • Coregistration of Preoperative MRI with Ex Vivo Mesorectal Pathology Specimens to Spatially Map Post-treatment Changes in Rectal Cancer Onto In Vivo Imaging: Preliminary Findings.

    abstract:RATIONALE AND OBJECTIVES:The objective of this study was to develop and quantitatively evaluate a radiology-pathology fusion method for spatially mapping tissue regions corresponding to different chemoradiation therapy-related effects from surgically excised whole-mount rectal cancer histopathology onto preoperative ma...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.006

    authors: Antunes J,Viswanath S,Brady JT,Crawshaw B,Ros P,Steele S,Delaney CP,Paspulati R,Willis J,Madabhushi A

    更新日期:2018-07-01 00:00:00

  • Minimized Radiation and Contrast Agent Exposure for Coronary Computed Tomography Angiography: First Clinical Experience on a Latest Generation 256-slice Scanner.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to evaluate the impact of the latest coronary computed tomography angiography (CCTA) techniques allowing a radiation- and contrast-sparing protocol on image quality in unselected patients referred for exclusion of suspected coronary artery disease (CAD). MATERIALS AND ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.03.015

    authors: Benz DC,Gräni C,Hirt Moch B,Mikulicic F,Vontobel J,Fuchs TA,Stehli J,Clerc OF,Possner M,Pazhenkottil AP,Gaemperli O,Buechel RR,Kaufmann PA

    更新日期:2016-08-01 00:00:00

  • MR imaging of the temporomandibular joint: a validation experiment in vitro.

    abstract:RATIONALE AND OBJECTIVES:The authors compared magnetic resonance (MR) image quality obtained from 3- and 1-mm-thick sections in the depiction of the temporomandibular joint (TMJ) and its adjacent structures. MATERIALS AND METHODS:Eight TMJ specimens from four adult cadaver heads were depicted with MR imaging. Both 3- ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(99)80116-0

    authors: Cavalcanti MG,Lew D,Ishimaru T,Ruprecht A

    更新日期:1999-11-01 00:00:00

  • Prediction accuracy of a sample-size estimation method for ROC studies.

    abstract:RATIONALE AND OBJECTIVES:Sample-size estimation is an important consideration when planning a receiver operating characteristic (ROC) study. The aim of this work was to assess the prediction accuracy of a sample-size estimation method using the Monte Carlo simulation method. MATERIALS AND METHODS:Two ROC ratings simul...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.01.007

    authors: Chakraborty DP

    更新日期:2010-05-01 00:00:00

  • Quantitative computed tomography analysis of local chemotherapy in liver tissue after radiofrequency ablation.

    abstract:RATIONALE AND OBJECTIVES:Computed tomography (CT) was used to noninvasively monitor local drug pharmacokinetics from polymer implants in rat livers before and following radiofrequency ablation. MATERIALS AND METHODS:Polymer matrixes containing carboplatin (a platinum-containing chemotherapeutic agent) were implanted i...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.09.007

    authors: Exner AA,Weinberg BD,Stowe NT,Gallacher A,Wilson DL,Haaga JR,Gao J

    更新日期:2004-12-01 00:00:00

  • Subtraction CT angiography of the lower extremities: single volume subtraction versus multi-segmented volume subtraction.

    abstract:RATIONALE AND OBJECTIVES:To validate the hypothesis that a multisegmented approach during subtraction computed tomography (CT) angiography of the lower extremities can improve bone removal efficiency by suppressing regional motion. MATERIALS AND METHODS:The institutional review board of our hospital approved this retr...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.01.024

    authors: Lee IJ,Chung JW,Hong H,Yin YH,Kim S,Park EA,Lee W

    更新日期:2011-07-01 00:00:00

  • Cardiac imaging training in radiology residency programs: a survey of radiology chief residents.

    abstract:RATIONALE AND OBJECTIVES:Comprehensive training in cardiac imaging during radiology residency is imperative if radiologists are to maintain a significant role in this rapidly growing field. In this study, radiology chief residents were surveyed to assess the current status of cardiac imaging training in radiology resid...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.02.002

    authors: Minocha J,Yaghmai V,Hammond N,Pyrros AT,Nikolaidis P

    更新日期:2010-06-01 00:00:00

  • ABR Core examination preparation: results of a survey of fourth-year radiology residents who took the 2013 examination.

    abstract:RATIONALE AND OBJECTIVES:A survey was administered to fourth-year radiology residents after receiving their results from the first American Board of Radiology (ABR) Core examination in 2013. The purpose was to gather information regarding resources and study strategies to share with program directors and future residen...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.07.026

    authors: Shetty AS,Grajo JR,Decker S,Heitkamp DE,DeStigter KK,Mezwa DG,Deitte L

    更新日期:2015-01-01 00:00:00

  • Assessing patient utilities for varying degrees of low back pain.

    abstract:RATIONALE AND OBJECTIVES:We sought to quantify patient preferences for mild, moderate, and severe low back pain via time-tradeoff analysis and utility measurement. MATERIALS AND METHODS:Forty-one patients being treated for low back pain in a tertiary care teaching hospital participated in the study. Patients were aske...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.11.031

    authors: Lai KC,Provenzale JM,Delong D,Mukundan S Jr

    更新日期:2005-04-01 00:00:00

  • Liver perfusion imaging in patients with primary and metastatic liver malignancy: prospective comparison between 99mTc-MAA spect and dynamic CT perfusion.

    abstract:RATIONALE AND OBJECTIVES:To prospectively analyze the correlation between parameters of liver perfusion from technetium99m-macroaggregates of albumin (99mTc-MAA) single photon emission computed tomography (SPECT) with those obtained from dynamic CT perfusion in patients with primary or metastatic liver malignancy. MAT...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.12.015

    authors: Reiner CS,Goetti R,Burger IA,Fischer MA,Frauenfelder T,Knuth A,Pfammatter T,Schaefer N,Alkadhi H

    更新日期:2012-05-01 00:00:00

  • Healthy aging: an automatic analysis of global and regional morphological alterations of human brain.

    abstract:RATIONALE AND OBJECTIVES:Morphologic changes of the human brain during healthy aging provide useful reference knowledge for age-related brain disorders. The aim of this study was to explore age-related global and regional morphological changes of healthy adult brains. MATERIALS AND METHODS:T1-weighted magnetic resonan...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.03.006

    authors: Long X,Liao W,Jiang C,Liang D,Qiu B,Zhang L

    更新日期:2012-07-01 00:00:00

  • Independent evaluation of computer classification of malignant and benign calcifications in full-field digital mammograms.

    abstract:RATIONALE AND OBJECTIVES:To evaluate whether a computer-aided diagnosis (CADx) technique can accurately classify breast calcifications in full-field digital mammograms (FFDMs) as malignant or benign. The computer technique was developed previously on screen-film mammograms (SFMs) in which individual calcifications were...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.12.012

    authors: Rana RS,Jiang Y,Schmidt RA,Nishikawa RM,Liu B

    更新日期:2007-03-01 00:00:00

  • The Role of Imaging in Health Screening: Overview, Rationale of Screening, and Screening Economics.

    abstract::Imaging screening examinations are growing in their indications and volume to identify conditions at an early, treatable stage. The Radiology Research Alliance's 'Role of Imaging in Health Screening' Task Force provides a review of imaging-based screening rationale, economics, and describes established guidelines by v...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.03.038

    authors: Ballard DH,Burton KR,Lakomkin N,Kim S,Rajiah P,Patel MJ,Mazaheri P,Whitman GJ

    更新日期:2020-05-11 00:00:00

  • Reproducibility of mRECIST in Measurement and Response Assessment for Hepatocellular Carcinoma Treated by Transarterial Chemoembolization.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the reproducibility of Modified Response Evaluation Criteria in Solid Tumors (mRECIST) for hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) using multiphasic computed tomography. MATERIALS AND METHODS:The institutional review board approved this retrospec...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2018.02.013

    authors: Choi MH,Park GE,Oh SN,Park MY,Rha SE,Lee YJ,Jung SE,Choi JI

    更新日期:2018-11-01 00:00:00

  • Discriminating Depth of Response to Therapy in Multiple Myeloma Using Whole-body Diffusion-weighted MRI with Apparent Diffusion Coefficient: Preliminary Results From a Single-center Study.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to measure apparent diffusion coefficient (ADC) in Chinese patients with newly diagnosed multiple myeloma by whole-body diffusion-weighted magnetic resonance imaging (WB-DWI MRI) and assess the diagnostic accuracy of ADC in the discrimination of deep response to induction chemo...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.008

    authors: Wu C,Huang J,Xu WB,Guan YJ,Ling HW,Mi JQ,Yan H

    更新日期:2018-07-01 00:00:00

  • Visual and Quantitative Evaluation of Emphysema: A Case-Control Study of 1111 Participants in the Pilot Swedish CArdioPulmonary BioImage Study (SCAPIS).

    abstract:RATIONALE AND OBJECTIVES:Emphysema is a hallmark of chronic obstructive pulmonary disease. The primary aim of this study was to investigate inter- and intraobserver agreement of visual assessment of mild emphysema in low-dose multidetector computed tomography of subjects in the pilot SCAPIS in order to certify consiste...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.06.019

    authors: Vikgren J,Khalil M,Cederlund K,Sörensen K,Boijsen M,Brandberg J,Lampa E,Sköld MC,Wollmer P,Lindberg E,Engvall JE,Bergström G,Torén K,Johnsson ÅA

    更新日期:2020-05-01 00:00:00

  • Imaging Features of Coronavirus disease 2019 (COVID-19): Evaluation on Thin-Section CT.

    abstract:RATIONALE AND OBJECTIVES:To retrospectively analyze the chest imaging findings in patients with coronavirus disease 2019 (COVID-19) on thin-section CT. MATERIALS AND METHODS:Fifty-three patients with confirmed COVID-19 infection underwent thin-section CT examination. Two chest radiologists independently evaluated the ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.03.002

    authors: Guan CS,Lv ZB,Yan S,Du YN,Chen H,Wei LG,Xie RM,Chen BD

    更新日期:2020-05-01 00:00:00

  • Cause of satisfaction of search effects in contrast studies of the abdomen.

    abstract:RATIONALE AND OBJECTIVES:Extraintestinal abnormalities visible without contrast material on abdominal radiographs are reported less frequently when contrast examinations are performed. Gaze dwell time was used to determine whether this difference is due to failure by observers to scan plain-film regions of contrast stu...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(96)80271-6

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Miller EM,Krupinski EA,Kreinbring K,Caldwell RT,Lu CH

    更新日期:1996-10-01 00:00:00

  • Longitudinal follow-up comparison of educational interventions: multimedia textbook, traditional lecture, and printed textbook.

    abstract:RATIONALE AND OBJECTIVES:The goal of this prospective, interinstitutional study was to compare the long-term instructional effectiveness of a pediatric multimedia textbook (MMTB) to that of a standard lecture and a printed textbook. MATERIALS AND METHODS:A randomized cohort of 89 3rd-year medical students from two ins...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s1076-6332(97)80074-8

    authors: D'Alessandro DM,Kreiter CD,Erkonen WE,Winter RJ,Knapp HR

    更新日期:1997-11-01 00:00:00

  • In vivo MR thermometry of frozen tissue using R2* and signal intensity.

    abstract::Cryoablation is one of several minimally invasive treatments that may be suitable for a targeted treatment of prostate cancer. Because efficacy is improved when a sufficiently cold end temperature is reached, the purpose of this work was to demonstrate an image-based thermometry method that could provide temperature m...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.06.006

    authors: Wansapura JP,Daniel BL,Vigen KK,Butts K

    更新日期:2005-09-01 00:00:00

  • Diffusion tensor tractography in the head-and-neck region using a clinical 3-T MR scanner.

    abstract:RATIONALE AND OBJECTIVES:Diffusion tensor tractography (DTT) for neural fibers of the head-and-neck region at 3T has not been reported. The purpose of this study was to evaluate the feasibility of using DTT for visualizing neural fibers in the head-and-neck region at 3T and to explore the use of this method in patients...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.01.019

    authors: Akter M,Hirai T,Minoda R,Murakami R,Saiki S,Okuaki T,Kitajima M,Fukuoka H,Sasao A,Nishimura S,Yumoto E,Awai K,Yamashita Y

    更新日期:2009-07-01 00:00:00

  • Tracheobronchial metal stents: effects of covering a bronchial ostium in pigs.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to examine the effects of placing a metal stent across a bronchial orifice. MATERIALS AND METHODS:Nine pigs were used as test subjects, because the right upper lobe bronchus comes directly off the trachea in these animals. One of three types of metal stents was pl...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(99)80253-0

    authors: Bjarnason H,Cahill B,Kløw NE,Han YM,Urness M,Günther R,Gomes MR,Rosenberg MS,Dietz CA Jr,Hunter DW

    更新日期:1999-10-01 00:00:00