Endovascular stent-graft management of thoracic aortic diseases.

Abstract:

:The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence.

journal_name

Eur J Radiol

authors

Dake MD

doi

10.1016/s0720-048x(01)00341-2

keywords:

subject

Has Abstract

pub_date

2001-07-01 00:00:00

pages

42-9

issue

1

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(01)00341-2

journal_volume

39

pub_type

杂志文章
  • Diagnosis of right-sided varicocele: a retrospective comparative study between clinical examination, Doppler findings, US imaging and vascular anatomy at phlebography.

    abstract::Historically varicocele is diagnosed almost exclusively on the left side. The introduction of new imaging techniques has allowed the identification and characterization of right varicocele. This study aims to compare the diagnostic accuracy of various imaging techniques to data obtained using phlebography in the diagn...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.05.015

    authors: Cariati M,Pieri S,Agresti P,Cariati M,Candito DF,Damiani G,Marzano D

    更新日期:2012-09-01 00:00:00

  • Presurgical fMRI evaluation of cerebral reorganization and motor deficit in patients with tumors and vascular malformations.

    abstract::The aim of this fMRI study was to evaluate the motor reorganization (cerebral plasticity) and the risk of motor deficit in patients presenting with tumors and vascular malformations, within the framework of their pre-surgical planning. Functional MR imaging data was obtained from 17 patients. Ten patients (seven with ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(02)00083-9

    authors: Baciu M,Le Bas JF,Segebarth C,Benabid AL

    更新日期:2003-05-01 00:00:00

  • Second-generation autologous chondrocyte transplantation: MRI findings and clinical correlations at a minimum 5-year follow-up.

    abstract:OBJECTIVE:To evaluate the clinical outcome of hyaluronan-based arthroscopic autologous chondrocyte transplantation at a minimum of 5 years of follow-up and to correlate it with the MRI evaluation parameters. METHODS:Fifty consecutive patients were included in the study and evaluated clinically using the Cartilage Stan...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.04.002

    authors: Kon E,Di Martino A,Filardo G,Tetta C,Busacca M,Iacono F,Delcogliano M,Albisinni U,Marcacci M

    更新日期:2011-09-01 00:00:00

  • Effects of respiratory manoeuvres on hepatic vein Doppler waveform and flow velocities in a healthy population.

    abstract:OBJECTIVE:This study was performed to determine the variations in Doppler waveforms and flow velocity during respiratory manoeuvres in healthy individuals with no liver disease. MATERIALS AND METHODS:In total, 100 individuals (75 women and 25 men) without known cardiac or liver disease were examined prospectively with...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.01.011

    authors: Altinkaya N,Koc Z,Ulusan S,Demir S,Gurel K

    更新日期:2011-07-01 00:00:00

  • Assessment of the gain transfer function of phosphors for application in medical imaging radiation detectors.

    abstract:OBJECTIVE:to study various phosphors used in detectors of medical imaging systems by the gain transfer function (GTF), defined in terms of X-ray luminescence efficiency, light spectrum and modulation transfer function. MATERIALS AND METHODS:four phosphor materials, La(2)O(2)S:Tb, Y(2)O(2)S:Tb, Y(2)O(2)S:Eu and Y(2)O(3...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(99)00106-0

    authors: Cavouras D,Kandarakis I,Maris T,Panayiotakis GS,Nomicos CD

    更新日期:2000-07-01 00:00:00

  • In vivo 1H MR spectroscopy of thyroid carcinoma.

    abstract::To determine if proton magnetic resonance spectroscopy (1H MRS) of thyroid carcinoma is feasible and to determine if 1H MRS spectra of malignant tumors differ from that of normal thyroid tissue. We performed 1H MRS at 1.5 T at echo-times (TE) 136 and 272 ms to examine eight patients with thyroid cancer (primary tumour...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.05.003

    authors: King AD,Yeung DK,Ahuja AT,Tse GM,Chan AB,Lam SS,van Hasselt AC

    更新日期:2005-04-01 00:00:00

  • Feasibility of an automatic computer-assisted algorithm for the detection of significant coronary artery disease in patients presenting with acute chest pain.

    abstract::Automatic computer-assisted detection (auto-CAD) of significant coronary artery disease (CAD) in coronary computed tomography angiography (cCTA) has been shown to have relatively high accuracy. However, to date, scarce data are available regarding the performance of auto-CAD in the setting of acute chest pain. This st...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.01.017

    authors: Kang KW,Chang HJ,Shim H,Kim YJ,Choi BW,Yang WI,Shim JY,Ha J,Chung N

    更新日期:2012-04-01 00:00:00

  • Multi-detector CT in the paediatric urinary tract.

    abstract::The use of paediatric multi-slice CT (MSCT) is rapidly increasing worldwide. As technology advances its application in paediatric care is constantly expanding with an increasing need for radiation dose control and appropriate utilization. Recommendations on how and when to use CT for assessment of the paediatric urina...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2011.12.005

    authors: Damasio MB,Darge K,Riccabona M

    更新日期:2013-07-01 00:00:00

  • Intraobserver interpretation of breast ultrasonography following the BI-RADS classification.

    abstract:PURPOSE:To use the BI-RADS ultrasound classification in an intraobserver retrospective study of the interpretation of breast images. MATERIALS AND METHODS:The study used 40 breast ultrasound images recorded in orthogonal planes, obtained from patients with an indication for surgery. Eight professionals experienced in ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.04.015

    authors: Calas MJ,Almeida RM,Gutfilen B,Pereira WC

    更新日期:2010-06-01 00:00:00

  • Diaphragmatic hernia: diagnostic approaches with review of the literature.

    abstract::Because surgical repair is indicated for the treatment of diaphragmatic hernia (DH), preoperative imaging of the diaphragmatic defect, hernia content, and associated complications with other organ's pathologies is important. While various techniques can be used on imaging of DHs, selection of the most effective but th...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2004.09.008

    authors: Eren S,Ciriş F

    更新日期:2005-06-01 00:00:00

  • MR imaging of vertebral metastases: evaluation of fat saturation imaging.

    abstract:OBJECTIVE:To compare conventional T1-weighted imaging (SE-T1) and chemical shift fat-saturation T1-weighted imaging (FS-T1) in the diagnosis of bone metastases. SUBJECTS:Twenty-two patients (101 vertebrae) with non-neoplastic lesions (Group 1) and 21 patients (72 vertebrae) with spinal metastases (Group 2) were evalua...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(93)90041-k

    authors: Uchida N,Sugimura K,Kajitani A,Yoshizako T,Ishida T

    更新日期:1993-09-01 00:00:00

  • Pulmonary MR angiography and perfusion imaging-A review of methods and applications.

    abstract::The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposu...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2016.10.003

    authors: Johns CS,Swift AJ,Hughes PJC,Ohno Y,Schiebler M,Wild JM

    更新日期:2017-01-01 00:00:00

  • Novel approach to improve molecular imaging research: correlation between macroscopic and molecular pathological findings in patients.

    abstract:PURPOSE:Currently, clinical research approaches are sparse in molecular imaging studies. Moreover, possible links between imaging features and pathological laboratory parameters are unknown, so far. Therefore, the goal was to find a possible relationship between imaging features and peripheral blood cell apoptosis, and...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.08.030

    authors: Böhm I

    更新日期:2011-09-01 00:00:00

  • Evaluation of traumatic spinal canal stenosis in thoracolumbar burst fractures. A comparison of three methods for measuring the percent canal occlusion.

    abstract:OBJECTIVES:Various percent canal occlusion measurement methods have been used to assess the spinal canal stenosis following a thoracolumbar burst fracture. However, there are no studies performed comparing these techniques. The objective of this study was to determine the reliability of three techniques used to measure...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.08.020

    authors: Dai LY,Wang XY,Jiang LS

    更新日期:2008-09-01 00:00:00

  • Primary extranodal Non-Hodgkin lymphoma of the orbital and paranasal region-a retrospective study.

    abstract:PURPOSE:Primary extranodal lymphomas of the orbit and sinonasal region are rare and occur almost only as Non-Hodgkin lymphoma (NHL). The purpose of this study was to determine the frequency of different subtypes of NHL in these regions and to describe their radiological features. MATERIALS AND METHODS:Between January ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.03.036

    authors: Sandner A,Surov A,Bach AG,Kösling S

    更新日期:2013-02-01 00:00:00

  • Nondiffuse fatty infiltration of the liver: does the uptake of iron-oxide increase or decrease at SPIO-enhanced MR imaging?

    abstract:PURPOSE:To clarify whether the uptake of SPIO increases or decreases in areas of fatty change compared with surrounding areas of nonfatty change at SPIO-enhanced MR imaging. MATERIALS AND METHODS:Approval for this retrospective study was obtained from our institutional review board. This study included 14 patients wit...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.04.004

    authors: Onoda H,Ito K,Tanabe M,Shimizu A,Matsunaga N

    更新日期:2011-08-01 00:00:00

  • Pluridirectional macrotomography with three-fold magnification. An assessment of image quality and clinical application.

    abstract::The purpose of this paper is to present the possible usefulness of macrotomography with three-fold magnification as demonstrated by a new apparatus. It can perform both conventional tomography and macrotomography of the same object plane. Quantitative evaluation included measurements of resolution, modulation transfer...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Ishigaki T,Sakuma S,Kamata N,Kamiya M

    更新日期:1984-02-01 00:00:00

  • Diffusion tensor magnetic resonance imaging of glial brain tumors.

    abstract:AIM:To evaluate the author's experience with the use of diffusion tensor magnetic resonance imaging (DTI) on patients with glial tumors. METHODS:A retrospective evaluation of a group of 24 patients with glial tumors was performed. There were eight patients with Grade II, eight patients with Grade III and eight patient...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.030

    authors: Ferda J,Kastner J,Mukensnabl P,Choc M,Horemuzová J,Ferdová E,Kreuzberg B

    更新日期:2010-06-01 00:00:00

  • PET-CT offers accurate assessment of tumour length in oesophageal malignancy.

    abstract:INTRODUCTION:Radiotherapy is increasingly used for both curative and palliative treatment of oesophageal malignancy. Accurate treatment depends on determining tumour location and length. This study assessed the value of PET-CT versus other staging modalities in determining tumour length. MATERIALS AND METHODS:Oesophag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.10.014

    authors: Rollins KE,Lucas E,Tewari N,James E,Hughes S,Catton JA

    更新日期:2015-02-01 00:00:00

  • Radiation exposure in CT-guided interventions.

    abstract:PURPOSE:To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. MATERIALS AND METHODS:We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage pla...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.08.035

    authors: Kloeckner R,dos Santos DP,Schneider J,Kara L,Dueber C,Pitton MB

    更新日期:2013-12-01 00:00:00

  • Quantitative assessment of the superior sagittal sinus on unenhanced computed tomography.

    abstract:PURPOSE:To determine the relationship between hemoglobin levels and attenuation measurements of the superior sagittal sinus (SSS) on unenhanced computed tomography (UECT). Secondly, to determine if SSS attenuation values are normally distributed such that measurements below and above certain thresholds are suggestive o...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.04.068

    authors: Fanous R,Leung A,Karlik S

    更新日期:2010-09-01 00:00:00

  • Serial magnetic resonance imaging evaluations of irradiated superior cervical sympathetic ganglia: Not every retropharyngeal enlarging mass is a sign of malignancy.

    abstract:INTRODUCTION:To describe serial changes in irradiated superior cervical sympathetic ganglia (SCSGs) on MRI (magnetic resonance imaging) evaluation in patients with head and neck squamous cell carcinoma (HNSCC) and to find the features differentiating them from the metastatic retropharyngeal lymph nodes. MATERIALS AND ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.11.008

    authors: Cho SJ,Lee JH,Park JE,Choi YJ,Kim JH,Kim HJ,Baek JH

    更新日期:2018-01-01 00:00:00

  • Reduced perfusion in white matter lesions in multiple sclerosis.

    abstract:OBJECTIVE:To investigate dynamic susceptibility contrast (DSC) perfusion weighted imaging (PWI) in white matter lesions (WML) in patients with multiple sclerosis (MS), using automatically generated binary masks of brain tissue. BACKGROUND:WML in MS have in some studies demonstrated perfusion abnormalities compared to ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.09.007

    authors: Sowa P,Bjørnerud A,Nygaard GO,Damangir S,Spulber G,Celius EG,Due-Tønnessen P,Harbo HF,Beyer MK

    更新日期:2015-12-01 00:00:00

  • Injuries at the articulating surfaces of bone (chondral, osteochondral, subchondral fractures and osteochondrosis dissecans)

    abstract::Fractures involving the articulating surfaces of bone are a common cause of joint disability. Management options are as numerous as the terms used to describe these lesions. These terms include osteochondral, transchondral, flake or chip fractures as well as osteochondrosis (osteochondritis) dissecans. The understandi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(95)00707-w

    authors: Bohndorf K

    更新日期:1996-03-01 00:00:00

  • Angiographic properties of Gd-DTPA-24-cascade-polymer--a new macromolecular MR contrast agent.

    abstract:PURPOSE:A new macromolecular MR contrast agent, Gd-DTPA-24-cascade-polymer, was assessed for MR angiography of peritumoral vessels in rats. MATERIAL AND METHODS:High resolution 3D-SPGR (TR/TE 100/5ms, alpha = 90 degrees) angiograms were acquired in 10 Fischer rats bearing subcutaneous R3230 mammary adenocarcinomas. MR...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(95)00645-7

    authors: Schwickert HC,Roberts TP,Mühler A,Stiskal M,Demsar F,Brasch RC

    更新日期:1995-07-01 00:00:00

  • Assessment of the diagnostic accuracy of T2*-weighted MR imaging for identifying hepatocellular carcinoma with liver explant correlation.

    abstract:BACKGROUND:T2*-weighted MRI may represent a novel method for identifying hepatocellular carcinoma (HCC). The goal of this study was to assess the diagnostic accuracy of T2*-weighted MRI for HCC with liver explant correlation. MATERIALS AND METHODS:A retrospective review identified 25 patients who had undergone liver t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.10.027

    authors: Hardie AD,Nance JW,Boulter DJ,Kizziah MK

    更新日期:2011-12-01 00:00:00

  • Amyloidosis in the head and neck: CT findings with clinicopathological correlation.

    abstract:PURPOSE:To characterize the CT imaging features of head and neck amyloidosis and correlate with extent of disease and clinical outcomes. MATERIALS AND METHODS:This retrospective study included 80 patients with head and neck amyloidosis who underwent soft tissue neck CT imaging between November 2003 and April 2018. The...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109034

    authors: Takumi K,Staziaki PV,Hito R,Nadgir RN,Berk JL,Andreu-Arasa VC,Chavez W,Sakai O

    更新日期:2020-07-01 00:00:00

  • Mammography with and without radiolucent positioning sheets: Comparison of projected breast area, pain experience, radiation dose and technical image quality.

    abstract:PURPOSE:To compare projected breast area, image quality, pain experience and radiation dose between mammography performed with and without radiolucent positioning sheets. METHODS:184 women screened in the Dutch breast screening programme (May-June 2012) provided written informed consent to have one additional image ta...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.07.005

    authors: Timmers J,Voorde MT,Engen RE,Landsveld-Verhoeven Cv,Pijnappel R,Greve KD,Heeten GJ,Broeders MJ

    更新日期:2015-10-01 00:00:00

  • Comparison of automated 4-chamber cardiac views versus axial views for measuring right ventricular enlargement in patients with suspected pulmonary embolism.

    abstract:PURPOSE:Compare the right ventricle to left ventricle (RV/LV) diameter ratio obtained from axial pulmonary CT angiograms (CTPA) with those derived from automatically generated 4-chamber (4-CH) reformats in patients with suspected pulmonary embolism (PE). METHODS:In this institutional review board-approved study we inc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.041

    authors: Wittenberg R,van Vliet JW,Ghaye B,Peters JF,Schaefer-Prokop CM,Coche E

    更新日期:2012-02-01 00:00:00

  • Assessment of anemia during CT pulmonary angiography.

    abstract:OBJECTIVES:Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. MATERIAL ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.07.008

    authors: Jung C,Groth M,Bley TA,Henes FO,Treszl A,Adam G,Bannas P

    更新日期:2012-12-01 00:00:00