Clinical late phase II trials of MultiHance (Gd-BOPTA) for the magnetic resonance imaging of liver tumors in Japan.

Abstract:

OBJECTIVE:The purpose of the study was to evaluate the safety and efficacy of Gd-BOPTA for liver imaging and to determine the most appropriate clinical dose to administer. METHODS:Gd-BOPTA was administered at a dose of 0.05 (group A), 0.1 (group B), or 0.2 (group C) mmol/kg to 201 patients suspected of having malignant liver tumors who had been referred for magnetic resonance imaging. Dynamic phase images (T1-weighted gradient echo sequences obtained during breath-hold), images obtained within 10 min of Gd-BOPTA injection (spin echo images) and delayed images obtained at 40-120 min after Gd-BOPTA injection (T1-weighted spin echo and gradient echo sequences during breathhold) were acquired. All post-contrast images were compared with pre-contrast images (T1- and T2-weighted sequences) obtained immediately prior to Gd-BOPTA administration. Safety was assessed in terms of the incidence of adverse events. RESULTS:The contrast efficacy for the dynamic study was classified as ( ) in 39.7% (27/68), 55.4% (36/65), and 47.0% (31/66) for groups A, B, and C, respectively. The contrast efficacy within 10 min of the injection was classified as ( ) in 7.6% (5/66), 16.9% (11/65), and 12.5% (8/64) for groups A, B, and C, respectively. The contrast efficacy at 40-120 min post-injection was classified as ( ) in 4.4% (3/68), 21.5% (14/65), and 20.0% (13/65) for groups A, B, and C, respectively with significant differences noted between groups A and B and groups A and C. As regards safety, the overall incidence of adverse reactions was 3.5% (7/199). CONCLUSION:Gd-BOPTA is a safe and efficacious contrast agent for use in both dynamic phase imaging and delayed (40-120 min) static imaging. A dose of 0.1 mmol/kg Gd-BOPTA appears to be the ideal dose for use in liver imaging in Japan.

journal_name

J Comput Assist Tomogr

authors

Kuwatsuru R,Kadoya M,Ohtomo K,Tanimoto A,Hirohashi S,Murakami T,Tanaka Y,Yoshikawa K,Katayama H

doi

10.1097/00004728-199911001-00010

keywords:

subject

Has Abstract

pub_date

1999-11-01 00:00:00

pages

S65-74

eissn

0363-8715

issn

1532-3145

journal_volume

23 Suppl 1

pub_type

临床试验,杂志文章,多中心研究,随机对照试验
  • Diffusely calcified renal cell carcinoma: CT features.

    abstract::Calcifications of renal masses are common. They are usually dense, partial, small, punctate, and linear opacities. Diffuse calcification is an extremely rare feature of renal masses. Generally, calcified renal cell carcinomas are hypovascular, with calcifications in the interstitium, and they also contain fibrotic cap...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Onitsuka H,Murakami J,Naito S,Souda R,Shioyama Y,Honda H,Araki A,Torii Y,Masuda K

    更新日期:1992-07-01 00:00:00

  • Attenuation values of fluid collections within the abdomen.

    abstract::In vivo attenuation values of 19 fluid collections in 17 patients were compared with in vitro values obtained on examination of the aspirated fluids within the calibration phantom of an EMI CT5005 body scanner. While the in vitro values showed a 5.2 Hounsfield unit (HU:1,000 scale). difference between cysts and absces...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198004000-00002

    authors: Bydder GM,Kreel L

    更新日期:1980-04-01 00:00:00

  • Whole-Body Diffusion Tensor Imaging: A Feasibility Study.

    abstract:OBJECTIVE:The aim of this study was to demonstrate the feasibility of whole-body diffusion tensor imaging (DTI) as a promising tool for research applications, for instance, for investigation of systemic muscle diseases. MATERIALS AND METHODS:Twelve healthy volunteers (mean age, 26.6 years; range, 20-39 years) underwen...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000324

    authors: Kenkel D,von Spiczak J,Wurnig MC,Filli L,Steidle G,Wyss M,Boss A

    更新日期:2016-01-01 00:00:00

  • Renal xanthogranulomatosis: radiological, clinical, and pathological features in two cases.

    abstract::Xanthogranulomatosis is a multicentric or systemic proliferative disorder of histiocytes. Two cases of xanthogranulomas are reported, each involving the kidneys. One patient also had concomitant orbital and CNS involvement. Primary renal involvement without associated retroperitoneal masses is an uncommon manifestatio...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Merine D,Fishman EK,Siegelman SS

    更新日期:1987-09-01 00:00:00

  • Cancer detection with whole-body PET using 2-[18F]fluoro-2-deoxy-D-glucose.

    abstract:OBJECTIVE:This study was done to determine the feasibility and potential utility of whole-body PET using the glucose analogue 2-[18F]fluoro-2-deoxy-D-glucose (FDG) for the detection of primary malignancies and metastatic lesions. MATERIALS AND METHODS:This was a prospective, nonrandomized study of whole-body FDG-PET i...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199307000-00012

    authors: Hoh CK,Hawkins RA,Glaspy JA,Dahlbom M,Tse NY,Hoffman EJ,Schiepers C,Choi Y,Rege S,Nitzsche E

    更新日期:1993-07-01 00:00:00

  • Changes of the hepatic CT absorption value in hemodialysis patients.

    abstract::The effect of hemodialysis on the CT absorption value of the liver was examined in 14 hemodialysis patients. In the high ultrafiltration group [10 patients with a weight loss of -1.7 to -3.5 (2.9 +/- 0.6) kg], the hepatic CT absorption value increased from 49.6 +/- 7.0 to 58.7 +/- 8.7 Hounsfield units (p less than 0.0...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198408000-00021

    authors: Ishikawa I,Tateishi K,Shinoda A,Onouchi Z,Saito Y,Asato T

    更新日期:1984-08-01 00:00:00

  • Automated image registration: II. Intersubject validation of linear and nonlinear models.

    abstract:PURPOSE:Our goal was to validate linear and nonlinear intersubject image registration using an automated method (AIR 3.0) based on voxel intensity. METHOD:PET and MRI data from 22 normal subjects were registered to corresponding averaged PET or MRI brain atlases using several specific linear and nonlinear spatial tran...

    journal_title:Journal of computer assisted tomography

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004728-199801000-00028

    authors: Woods RP,Grafton ST,Watson JD,Sicotte NL,Mazziotta JC

    更新日期:1998-01-01 00:00:00

  • Disruption of the blood-brain barrier caused by nonionic contrast medium used for abdominal angiography: CT demonstration.

    abstract::We describe a case of disruption of the blood-brain barrier (BBB) by nonionic, low osmolality contrast medium after abdominal angiography. One plausible explanation of this event is that acute hypertension during angiography may have increased the BBB permeability, allowing the contrast medium to leak across it. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198909000-00027

    authors: Okazaki H,Tanaka K,Shishido T,Nagase H,Hoshino M,Takebayashi S,Endoh O,Takamura Y

    更新日期:1989-09-01 00:00:00

  • 64-Channel cardiac computed tomography: intraobserver and interobserver variability, part 2: global and regional ventricular function, mass, and first pass perfusion.

    abstract:OBJECTIVES:To assess intraobserver and interobserver variability in cardiac computed tomographic measurements of global biventricular function, left ventricular (LV) regional wall motion, systolic wall thickening, and first pass perfusion in 3 patient cohorts at very low, low to intermediate, and intermediate to high c...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31817c4259

    authors: Nicol ED,Stirrup J,Roughton M,Padley SP,Rubens MB

    更新日期:2009-03-01 00:00:00

  • MR imaging of lumbar juxtaarticular cysts.

    abstract::Three surgically proven cases of lumbar extradural juxtaarticular cysts were examined by magnetic resonance (MR) imaging. The highly variable MR signal patterns are presented. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199005000-00018

    authors: Awwad EE,Martin DS,Smith KR Jr,Bucholz RD

    更新日期:1990-05-01 00:00:00

  • Imaging of Hereditary Tumors of the Female Genital System.

    abstract::Cancers of the female genital system, particularly endometrial and ovarian cancers, can be associated with hereditary cancer syndromes such as hereditary breast and ovarian cancer and Lynch syndrome. Cancers that are found in the setting of a hereditary cancer syndrome are often unique in presentation, clinical featur...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/RCT.0000000000000558

    authors: Rothan SM,Menias CO,ElGuindy YM,Jensen CT,Shaaban AM,Bhosale P,Lee MV,Katabathina VS,Elsayes KM

    更新日期:2017-05-01 00:00:00

  • High resolution CT findings in miliary lung disease.

    abstract::High-resolution CT (HRCT) and chest radiographs were compared in nine patients with miliary lung disease. In all cases, miliary disease was documented to be infectious in etiology; six of these patients proved to be human immunodeficiency virus (HIV) positive. A mixture of both sharply and poorly defined 1-3 mm nodule...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199205000-00009

    authors: McGuinness G,Naidich DP,Jagirdar J,Leitman B,McCauley DI

    更新日期:1992-05-01 00:00:00

  • Nodular hepatocellular carcinoma: variation of tumor conspicuity on single-level dynamic scan and optimization of fixed delay times for two-phase helical CT.

    abstract:PURPOSE:The purpose of this work was to determine the optimal delay times in two-phase helical CT for nodular hepatocellular carcinoma (HCC). METHOD:Twenty-four patients with nodular HCC (size 2.1-6.7 cm, mean 4.2 cm) were divided into three groups to undergo single-level dynamic CT with 150 ml of contrast material (i...

    journal_title:Journal of computer assisted tomography

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004728-200003000-00005

    authors: Lee KH,Choi BI,Han JK,Jang HJ,Kim TK,Han MC

    更新日期:2000-03-01 00:00:00

  • Anomalous systemic arterialization to normal basal segments of the left lower lobe: helical CT and CTA findings.

    abstract:PURPOSE:The purpose of this work was to evaluate the helical CT and CT angiography (CTA) findings of anomalous systemic artery (ASA) to the basal segments of the left lower lobe (LLL). METHOD:Three patients (two had hemoptysis, one was asymptomatic) with blotchy nodular density in the LLL revealed on chest radiographs...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200011000-00026

    authors: Ko SF,Ng SH,Lee TY,Wan YL,Lee CM,Hsieh MJ,Chen MC

    更新日期:2000-11-01 00:00:00

  • Solid organizing hepatic abscesses mimic hepatic tumor: Multiphasic computed tomography and magnetic resonance imaging findings with histopathologic correlation.

    abstract:OBJECTIVE:To describe the computed tomography (CT) and magnetic resonance imaging (MRI) findings of solid organizing hepatic abscesses and correlate them with the pathologic findings. METHODS:Ten patients with 10 pathologically proven solid organizing hepatic abscesses who underwent 3-phase CT (n = 10) or MRI (n = 7) ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200603000-00004

    authors: Kim YK,Kim CS,Lee JM,Ko SW,Moon WS,Yu HC

    更新日期:2006-03-01 00:00:00

  • Image quality in cranial computed tomography.

    abstract::Image quality in cranial computed tomography (CT) was evaluated with phantom and patient studies on both a first (single beam) and a second (multiple beam) generation scanner. When comparable radiation doses were used, there were only minor differences in resolution, low contrast detectability, and noise level. The pa...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197807000-00020

    authors: Zatz LM

    更新日期:1978-07-01 00:00:00

  • Coronary artery calcification on computed tomography correlates with mortality in chronic obstructive pulmonary disease.

    abstract:OBJECTIVE:This cross-sectional study assessed the prognostic implications of computed tomography (CT) coronary artery calcification (CAC), independent of emphysema, in patients with chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS:Coronary artery calcification and emphysema were assessed on noncontr...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000119

    authors: OʼHare PE,Ayres JF,OʼRourke RL,Slaughter RE,Marshall HM,Bowman RV,Fong KM,Yang IA

    更新日期:2014-09-01 00:00:00

  • Unusual pattern of a deep developmental venous anomaly on CT and MR studies.

    abstract:OBJECTIVE:This article focuses on an unusual cross-sectional imaging pattern of a deep developmental venous anomaly (DVA). Since these anomalies are nonpathologic, they must not be interpreted as a disease that requires further costly workup and potentially injurious procedures (cerebral angiography). MATERIALS AND ME...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199511000-00008

    authors: Borden NM,Khayata MH,Dean BL,Flom RA

    更新日期:1995-11-01 00:00:00

  • Spread of infection to Virchow-Robin spaces in a patient with Streptococcus pneumoniae meningitis.

    abstract::We present a case of a child with acute bacterial leptomeningeal infection caused by Streptococcus pneumoniae. There was an extension of infection along multiple Virchow-Robin spaces into the brain parenchyma, resulting in multiple microabscesses. These abscesses showed restricted diffusion on the diffusion-weighted i...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e318187ff15

    authors: Gordon M,Parmar H,Ibrahim M

    更新日期:2009-07-01 00:00:00

  • Ureteral pseudodiverticulosis: a unique case diagnosed by multidetector computed tomography.

    abstract::Presented is a case of ureteral pseudodiverticulosis diagnosed by multidetector computed tomography (CT). Axial and coronal reformatted CT images revealed multiple small (2-4 mm) outpouchings of both ureters, characteristic of ureteral pseudodiverticulosis. The unenhanced CT also revealed a 6-mm stone at the left uret...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e318173ebd0

    authors: Spalluto LB,Woodfield CA

    更新日期:2009-03-01 00:00:00

  • Virtual Monoenergetic Images for Diagnostic Assessment of Hypodense Lesions Within the Liver: Semiautomatic Estimation of Window Settings Using Linear Models.

    abstract:OBJECTIVE:The aim of the study was to establish the reference window settings for display of virtual monoenergetic images (VMIs) from spectral detector computed tomography when assessing hypodense liver lesions. METHODS:In patients with cysts (n = 24) or metastases (n = 26), objective (HU, signal-to-noise ratio [SNR])...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000794

    authors: Große Hokamp N,Obmann VC,Kessner R,Gilkeson RC,Gupta A,Persigehl T,Haneder S,Ramaiya N

    更新日期:2018-11-01 00:00:00

  • Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection.

    abstract:PURPOSE:The purpose of this work was to determine the accuracy of predicting arterial enhancement from peripheral versus central venous test bolus injections at CT angiography (CTA). METHOD:In 40 patients with abdominal aortic aneurysms, aortoiliac enhancement profiles were predicted by mathematical deconvolution of t...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200103000-00024

    authors: Hittmair K,Fleischmann D

    更新日期:2001-03-01 00:00:00

  • Additional coronal images using low-milliamperage multidetector-row computed tomography: effectiveness in the diagnosis of bronchiectasis.

    abstract:PURPOSE:The aim of our study was to evaluate the effectiveness of additional coronal images using low-milliamperage multidetector-row computed tomography (CT) in the diagnosis of bronchiectasis. METHODS:Helical volumetric CT scans (120 kVp, 70 mA, 2.5-mm collimation, table speed of 15 mm/s, table rotation time of 1 se...

    journal_title:Journal of computer assisted tomography

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004728-200307000-00006

    authors: Sung YM,Lee KS,Yi CA,Yoon YC,Kim TS,Kim S

    更新日期:2003-07-01 00:00:00

  • Minor ossicular anomalies in the middle ear: role of submillimeter multislice computed tomography.

    abstract:OBJECTIVE:The objective was to elucidate clinical effectiveness of submillimeter multislice 2- and 3-dimensional computed tomography (CT) for diagnosis of congenital middle ear anomaly. MATERIALS AND METHODS:Preoperative CT and operative findings were retrospectively analyzed in 36 ears of 33 patients. The distance be...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000093

    authors: Nakasato T,Nakayama T,Nakayama M,Ehara S,Ohtsuka H,Sato H

    更新日期:2014-09-01 00:00:00

  • The rubber circle: a technique for analyzing computed tomography scans.

    abstract::The authors describe a technique for automated analysis of lesions demonstrated by computed tomography. A seed circle may be superimposed on a lesion by an operator controlled program. By selecting density limits, the program will then automatically outline a particular area of abnormal density and calculate the stati...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Hand WM,Wilk J,Huckman MS

    更新日期:1977-07-01 00:00:00

  • Magnetic resonance elastography of liver: clinical applications.

    abstract::Magnetic resonance elastography (MRE) has been successfully implemented in the assessment of diffuse liver diseases. Currently, MRE is the most accurate noninvasive technique for detection and staging of liver fibrosis with a potential to replace liver biopsy. Magnetic resonance elastography is able to differentiate i...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/RCT.0000000000000032

    authors: Venkatesh SK,Yin M,Ehman RL

    更新日期:2013-11-01 00:00:00

  • Diffusion-weighted echo planar imaging of the normal human cervical spinal cord.

    abstract::We obtained diffusion-weighted echo planar images of the human cervical cord in vivo and correlated them with histopathologic findings. Images were obtained in 17 healthy volunteers using a 1.5 T clinical MR unit. When motion-probing gradients were added perpendicular to the long axis of the cord, the white matter was...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200005000-00023

    authors: Nagayoshi K,Kimura S,Ochi M,Hayashi K,Okimoto T,Wakebe T,Saiki K

    更新日期:2000-05-01 00:00:00

  • Solid renal mass in the cancer patient: second primary renal cell carcinoma versus renal metastasis.

    abstract::Most renal metastases are asymptomatic, occur with widespread metastatic disease, and are too small to be detected with computed tomography (CT). Rarely they form large masses. These are typically angiographically hypovascular and show only minimal CT contrast enhancement. Renal carcinoma as a second primary malignanc...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198306000-00011

    authors: Pagani JJ

    更新日期:1983-06-01 00:00:00

  • Squamous cell carcinoma of the anus and rectum in homosexual men: CT findings.

    abstract:OBJECTIVE:Homosexual men are at risk for a variety of infectious and neoplastic diseases of the anus and rectum, many of which have been reported in the radiologic literature. The purpose of this study was to describe the CT findings in homosexual men with squamous cell carcinoma of the anus and rectum, a topic that ha...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199411000-00013

    authors: Radin DR

    更新日期:1994-11-01 00:00:00

  • Rotating conventional gamma camera single-photon tomographic system: physical characterization.

    abstract::A whole-body single-photon emission computed tomography system has been evaluated in terms of its physical performance. It consists of a standard GE 400 T maxi camera rotating on a ring stand, coupled to an Informatek Simis 3 computer system. In its standard mode of operation, 64 or 128 successive views of 64 X 64 or ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198108000-00017

    authors: Soussaline FP,Todd-Popkropek AE,Zurowski S,Huffer E,Raynaud CE,Kellershohn CL

    更新日期:1981-08-01 00:00:00