Abstract:
OBJECTIVE:To determine whether a cellular phone would interfere with the operation of mechanical ventilators. DESIGN:Laboratory study. SETTING:University medical center. SUBJECTS:Fourteen mechanical ventilators. INTERVENTIONS:We evaluated change in operation and malfunction of the mechanical ventilators. MEASUREMENTS AND MAIN RESULTS:The cellular phone (Nokia 6120i) was computer controlled, operating at 828.750 MHz analog modulation. It was operated at 16, 40, 100, 250, and 600 mW, 30 cm from the floor and 30, 15, and <3 cm from all sides of each ventilator. Six of the 14 ventilators tested malfunctioned when a cellular phone at maximum power output was placed < or =15 cm from the device. None of these responses were considered immediately life threatening except for the response of the Puritan Bennett 840, which stopped ventilating when the cellular phone at maximum power output was placed < or =30 cm from the ventilator. One ventilator doubled the ventilatory rate and another increased the displayed tidal volume from 350 to 1033 mL. In one of the infant ventilators, displayed tidal volume increased from 21 to 100 mL. In another ventilator, the high respiratory rate alarm sounded but the rate had not changed. CONCLUSIONS:In a controlled laboratory setting, cellular phones placed in close proximity to some commercially available intensive care ventilators can cause malfunctions, including irrecoverable cessation of ventilation. This is most likely to occur if the cellular phone is <30 cm from the device and ringing. Based on our data and the available literature, we believe it is reasonably safe to permit the use of cellular phones in the intensive care unit, as long as they are kept > or =3 feet from all medical devices. The current electromagnetic compatibility standards for mechanical ventilators are inadequate to prevent malfunction. Manufacturers should ensure that their products are not affected by wireless technology even when placed immediately next to the device.
journal_name
Crit Care Medjournal_title
Critical care medicineauthors
Shaw CI,Kacmarek RM,Hampton RL,Riggi V,El Masry A,Cooper JB,Hurford WEdoi
10.1097/01.ccm.0000120061.01431.dbsubject
Has Abstractpub_date
2004-04-01 00:00:00pages
928-31issue
4eissn
0090-3493issn
1530-0293pii
00003246-200404000-00005journal_volume
32pub_type
杂志文章abstract:OBJECTIVES:The main objective of the study was to determine the prevalence of venous thromboembolism events in patients infected with severe acute respiratory syndrome coronavirus 2 requiring venovenous extracorporeal membrane oxygenation. The secondary objective was to compare venous thromboembolism events and coagula...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/CCM.0000000000004504
更新日期:2020-10-01 00:00:00
abstract:OBJECTIVES:Sepsis-associated changes of the arachidonic acid metabolism and the utility of arachidonic acid metabolites for the diagnosis of sepsis have been poorly investigated so far. Therefore, the primary objective of our study was to screen for differentially regulated arachidonic acid metabolites in septic patien...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/CCM.0b013e3182416f05
更新日期:2012-05-01 00:00:00
abstract:OBJECTIVE:To determine the blood discard volume, as a multiple of deadspace, that is required for accurate arterial blood gas and electrolyte testing from arterial catheters. DESIGN:Prospective, controlled, crossover trial. SETTING:Eighteen-bed intensive care unit of a metropolitan teaching hospital. PATIENTS:A tota...
journal_title:Critical care medicine
pub_type: 临床试验,杂志文章
doi:10.1097/01.CCM.0000063448.98777.EF
更新日期:2003-06-01 00:00:00
abstract:OBJECTIVE:Mannitol is widely used in hospitals worldwide to treat patients with high intracranial pressure and/or cerebral edema. One of the mechanisms by which mannitol is thought to affect intracranial pressure is by increasing the patient's serum osmolarity, but not the osmolarity in the brain or cerebrospinal fluid...
journal_title:Critical care medicine
pub_type: 临床试验,杂志文章
doi:10.1097/01.CCM.0000050287.68977.84
更新日期:2003-02-01 00:00:00
abstract:BACKGROUND:Early excision with autograft-allograft closure is standard in severe burn management. Cadaver skin is associated with risks such as antigenicity, infection, and limited availability and shelf life. Previous studies have shown that Integra is safe to use in burns of <20% total body surface area. However, the...
journal_title:Critical care medicine
pub_type: 杂志文章,随机对照试验
doi:10.1097/01.CCM.0000285991.36698.E2
更新日期:2007-11-01 00:00:00
abstract:OBJECTIVE:The flow rate of a liquid drainage from the lungs is limited because of the elastic nature of the airways. This study was designed to clarify the relationship between intrapulmonary liquid volume and the development of the flow limitation or choked flow phenomenon as a function of expiratory flow rate during ...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/01.CCM.0000104918.48411.91
更新日期:2004-01-01 00:00:00
abstract::Measuring gas exchange in critically ill patients can provide valuable information on their nutritional status and energy expenditure. Several semiautomated machines are available for measuring oxygen consumption (VO2) and carbon dioxide production (VCO2). This study evaluated, under controlled laboratory conditions, ...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-198609000-00010
更新日期:1986-09-01 00:00:00
abstract:OBJECTIVE:To determine prevalence, risk factors, and outcome of thrombocytopenia in medical intensive care patients. DESIGN:Prospective observational study. SETTING:The 12-bed medical intensive care unit of a university hospital. PATIENTS:All consecutively admitted patients with normal platelet count at admission an...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-200208000-00015
更新日期:2002-08-01 00:00:00
abstract:OBJECTIVE:This report will describe the preparations for and the provision of care of two patients with Ebola virus disease in the biocontainment unit at the University of Nebraska Medical Center. DATA SOURCES:Patient medical records. STUDY SELECTION:Not applicable. DATA EXTRACTION:Not applicable. DATA SYNTHESIS:No...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/CCM.0000000000000935
更新日期:2015-06-01 00:00:00
abstract::The venous-arterial PCO2 gradient may increase in certain low-flow states, such as CPR and canine endotoxemia. To determine whether venous hypercarbia also occurs in hemorrhagic shock, we studied 12 anesthetized, mechanically ventilated dogs. We performed laparotomies on the animals, inserting catheters into their ren...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-198705000-00013
更新日期:1987-05-01 00:00:00
abstract:OBJECTIVE:To evaluate the occurrence of complications and patient deteriorations during the air and ground transportation of intubated pediatric patients, performed by a nonphysician-based team under the direction of an intensive care attending physician or fellow. DESIGN:Retrospective chart review. SETTING:A 600-bed...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-199207000-00011
更新日期:1992-07-01 00:00:00
abstract:OBJECTIVE:Anecdotal reports suggest that propofol (Diprivan) may stimulate mucus hypersecretion in patients without pulmonary disease. The purpose of this study was to evaluate the effect of methohexital or propofol anesthesia on the physical and transport properties of airway mucus in spontaneously breathing dogs. DE...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-200105000-00035
更新日期:2001-05-01 00:00:00
abstract::We compared the degree of complement activation in 15 patients receiving massive blood transfusions and 21 patients with the septic syndrome and examined its association with other risk factors for adult respiratory distress syndrome (ARDS). Patients with massive transfusion (n = 8) as their only risk factor for ARDS ...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-198612000-00001
更新日期:1986-12-01 00:00:00
abstract:OBJECTIVES:In postcardiac surgery patients, we often noticed that monitored tidal volumes exceeded the ventilator settings. We investigated whether cardiogenic oscillation causes overestimation of tidal volume. DESIGN:Prospective, observational, clinical study. SETTING:Surgical intensive care unit in a national heart...
journal_title:Critical care medicine
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/01.ccm.0000129487.25203.1f
更新日期:2004-07-01 00:00:00
abstract:OBJECTIVE:Quality of care for patients admitted with pneumonia varies across hospitals, but causes of this variation are poorly understood. Whether hospitals with high ICU utilization for patients with pneumonia provide better quality care is unknown. We sought to investigate the relationship between a hospital's ICU a...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/CCM.0000000000000925
更新日期:2015-06-01 00:00:00
abstract:OBJECTIVE:To evaluate the possible effects of a combination of systemic nitric oxide synthesis inhibition (to increase mean arterial blood pressure) and nitric oxide inhalation (to decrease pulmonary vascular pressure) in porcine endotoxin shock. DESIGN:Prospective trial. SETTING:Laboratory at a large university medi...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-199505000-00020
更新日期:1995-05-01 00:00:00
abstract::A new quantitative method for measuring the prognosis and severity of illness in terms of probability of survival was developed from 224 studies in an index population of 220 critically ill surgical patients. Patients were selected preoperatively to eliminate pre-existing cardiac disease, cirrhosis, nutritional debili...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-198502000-00007
更新日期:1985-02-01 00:00:00
abstract::The recommended rates for closed-chest cardiac compressions during CPR are based on physiologic variations with increasing age rather than experimental data. Using puppies, we compared mean arterial pressure, cardiac index (CI), and cerebral blood flow (CBF) at a slow (40/min, group 1) and a rapid (120/min, group 2) r...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-198710000-00009
更新日期:1987-10-01 00:00:00
abstract:OBJECTIVE:To evaluate whether current criteria for the diagnosis of brain death fulfill the requirement for the "irreversible cessation of all functions of the entire brain, including the brainstem." DATA SOURCES:Clinical, philosophical, legal, and public policy literature on the subject of brain death. DATA EXTRACTI...
journal_title:Critical care medicine
pub_type: 杂志文章,评审
doi:10.1097/00003246-199212000-00018
更新日期:1992-12-01 00:00:00
abstract:BACKGROUND AND METHODS:To determine the effects of reduced cerebral perfusion pressures produced by hemorrhage alone or in combination with intracranial hypertension on thromboxane A2 (TxA2) production, we undertook a randomized study in 38 anesthetized, mongrel dogs. Animals were subjected to 30 mins of hemorrhagic sh...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-199104000-00013
更新日期:1991-04-01 00:00:00
abstract:OBJECTIVES:Increases in exhaled nitric oxide have been demonstrated to originate from the lungs of rats after septic lung injury. The aim of this study was to investigate whether treatment with the nitric oxide synthase inhibitor N-nitro-L-arginine methyl ester (L-NAME) would prevent lipopolysaccharide (LPS)-induced in...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-199802000-00033
更新日期:1998-02-01 00:00:00
abstract:OBJECTIVE:The neuroprotective effects of the noble gas xenon are well known. Argon, in contrast to xenon, is abundant, inexpensive, and therefore widely applicable. In this study, we analyzed the possible neuroprotective role of argon in an in vivo rat model of acute focal cerebral ischemia. DESIGN:Controlled laborato...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/CCM.0b013e31821209be
更新日期:2011-06-01 00:00:00
abstract:OBJECTIVE:To assess the effect of high-dose N-acetylcysteine on renal function in cardiac surgery patients at higher risk of postoperative renal failure. DESIGN:Multiblind, placebo-controlled, randomized, phase II clinical trial. SETTING:Operating rooms and intensive care units of two tertiary referral hospitals. PA...
journal_title:Critical care medicine
pub_type: 杂志文章,随机对照试验
doi:10.1097/01.CCM.0000261887.69976.12
更新日期:2007-05-01 00:00:00
abstract::Significant resistance was encountered when an attempt was made to withdraw a persistently wedged pulmonary artery catheter. A small amount of air was injected into the balloon lumen with great difficulty. This injection freed the catheter which was removed, but produced significant sudden hemoptysis and a pneumothora...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/00003246-198106000-00013
更新日期:1981-06-01 00:00:00
abstract:OBJECTIVES:To assess the reversibility of acute kidney injury-induced neutrophil dysfunction and to identify involved mechanisms. DESIGN:Controlled laboratory experiment and prospective observational clinical study. SETTING:University laboratory and hospital. SUBJECTS:C57BL/6 wild-type mice. PATIENTS:Patients with ...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/CCM.0000000000001472
更新日期:2016-07-01 00:00:00
abstract:OBJECTIVES:Excessive inflammation is closely related to severity and outcome of sepsis. Because interleukin-1-receptor-associated kinase 1 is a key signaling protein in the activation of NF-κB during infection, we aimed to evaluate the effect of functionally relevant haplotypes of IRAK1 on severity, development of acut...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/CCM.0b013e3181f9f9c7
更新日期:2010-12-01 00:00:00
abstract:OBJECTIVE:To assess the intrarater and interrater reliability of electrocardiogram (ECG) interpretation in critically ill patients and to assess the effect of knowledge of cardiac troponin values on these reliability estimates. DESIGN:Prospective cohort study. SETTING:Fifteen-bed medical-surgical intensive care unit....
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/01.CCM.0000214679.23957.90
更新日期:2006-05-01 00:00:00
abstract:OBJECTIVE:This article analyzes, from a legal perspective, a recent phenomenon involving a clash between the values of attending medical personnel and the instructions of surrogate decision-makers acting on behalf of incompetent patients. Some hospitals have gone to court to challenge decisions by surrogates to continu...
journal_title:Critical care medicine
pub_type: 杂志文章,评审
doi:10.1097/00003246-199605000-00026
更新日期:1996-05-01 00:00:00
abstract:OBJECTIVE:Nondepolarizing neuromuscular blocking agents are commonly used in the intensive care setting, but they have occasionally been associated with development of myopathy. In addition, diaphragmatic atrophy and a reduction in diaphragmatic force were reported after short-term controlled mechanical ventilation in ...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/01.CCM.0000245783.28478.AD
更新日期:2006-12-01 00:00:00
abstract:OBJECTIVES:There is controversy regarding the benefits of N-acetylcysteine in acute kidney injury. This study was to compare three commonly used regimens and explore which regimen is best for the protection of acute kidney injury. DESIGN:Prospective experimental study. SETTING:University research laboratory. INTERVE...
journal_title:Critical care medicine
pub_type: 杂志文章
doi:10.1097/CCM.0b013e31822575fc
更新日期:2011-11-01 00:00:00