Arterial MR imaging phase-contrast flow measurement: improvements with varying velocity sensitivity during cardiac cycle.

Abstract:

:To reduce noise in velocity images of magnetic resonance (MR) phase-contrast measurements, the authors implemented and evaluated a pulse sequence that enables automatic optimization of the velocity-encoding parameter V(enc) for individual heart phases in pulsatile flow on the basis of a rapid prescan. This sequence was prospectively evaluated by comparing velocity-to-noise ratios with those from a standard MR flow scan obtained in the carotid artery in eight volunteers. This sequence was shown to improve velocity-to-noise ratios by a factor of 2.0-6.0 in all but the systolic heart phase and was determined to be an effective technique for reducing noise in phase-contrast velocity measurements.

journal_name

Radiology

journal_title

Radiology

authors

Ringgaard S,Oyre SA,Pedersen EM

doi

10.1148/radiol.2321030783

subject

Has Abstract

pub_date

2004-07-01 00:00:00

pages

289-94

issue

1

eissn

0033-8419

issn

1527-1315

pii

232/1/289

journal_volume

232

pub_type

杂志文章
  • Dynamic contrast-enhanced MR imaging measurement of vertebral bone marrow perfusion may be indicator of outcome of acute myeloid leukemia patients in remission.

    abstract:PURPOSE:To examine whether dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging measurement of bone marrow perfusion in acute myeloid leukemia (AML) patients in complete remission (CR) is associated with outcome and survival. MATERIALS AND METHODS:After institutional review board approval and infor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100995

    authors: Chen BB,Hsu CY,Yu CW,Hou HA,Liu CY,Wei SY,Chou WC,Tien HF,Shih TT

    更新日期:2011-03-01 00:00:00

  • Timing and course of neonatal intracranial hemorrhage using real-time ultrasound.

    abstract::Knowledge of the timing and course of neonatal intracranial hemorrhage is essential in determining the etiology of hemorrhage, since the key to preventing neurologic damage in newborns is to define preventable causes and to treat the complications of hemorrhage. In an intensive study of 49 neonates delivered less than...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.1.3880600

    authors: Rumack CM,Manco-Johnson ML,Manco-Johnson MJ,Koops BL,Hathaway WE,Appareti K

    更新日期:1985-01-01 00:00:00

  • Application of region-of-interest imaging techniques to neurointerventional radiology.

    abstract::To reduce radiation exposure to patients and staff during neurointerventional procedures, region-of-interest (ROI) techniques were used with fluoroscopy, road mapping, and digital subtraction angiography in 19 patients. ROI filters, made of multiple layers of gadolinium, were attached to the collimators. Patient skin ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.3.8638020

    authors: Rudin S,Guterman LR,Granger WE,Bednarek DR,Hopkins LN

    更新日期:1996-06-01 00:00:00

  • A molded acrylic applicator guiding the peroral X-ray beam.

    abstract::An intraoral acrylic mold technique to guide and maintain beam direction during oral roentgen therapy is described. It is used in combination with the treatment cone and a lead tube and protective diaphragm for collimation of the beam. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.2.471

    authors: Pantoja E,Rodriguez-Ibanez I

    更新日期:1976-02-01 00:00:00

  • Preparation of 52Fe and its use in a 52Fe/52mMn generator.

    abstract::Clinically useful quantities of 52Fe have been prepared at the Brookhaven Linac Isotope Producer (BLIP) by bombarding manganese or nickel targets with medium energy protons. After chemical separation, 52Fe is loaded onto a generator column from which carrier-free 52Mn is eluted. The 52mMn generator is potentially usef...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.2.475

    authors: Ku TH,Richards P,Stang LG Jr,Prach T

    更新日期:1979-08-01 00:00:00

  • Acute-phase response after stent implantation in the carotid artery: association with 6-month in-stent restenosis.

    abstract:PURPOSE:To determine the prognostic importance of periintervention serum levels of acute-phase reactants in 6-month restenosis after stent implantation in the carotid artery. MATERIALS AND METHODS:One hundred eight consecutive patients with 70% or greater stenosis of the internal carotid artery (ICA) according to the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2272020183

    authors: Schillinger M,Exner M,Mlekusch W,Rumpold H,Ahmadi R,Sabeti S,Lang W,Wagner O,Minar E

    更新日期:2003-05-01 00:00:00

  • Local control of breast cancer with tumorectomy plus radiotherapy or radiotherapy alone.

    abstract::58 cases of breast cancer treated primarily by radiotherapy were evaluated to determine the optimum dose for local control. Of 36 patients with T1 + T2 lesions who had tumorectomy prior to radiotherapy, incomplete excision of tumor was demonstrated on microscopic examination in 18. The minimum tumor dose to the breast...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/121.2.455

    authors: Ghossein NA,Stacey P,Alpert RT,Ager PJ,Krishnaswamy V

    更新日期:1976-11-01 00:00:00

  • An improved radionuclide method for the diagnosis of gastroesophageal reflux and aspiration in children (milk scan).

    abstract::A radionuclide study using technetium-99m-labelled milk feeding is described for the detection of gastroesophageal reflux and aspiration in children. A comparison of findings in 39 patients referred for both radiographic and radionuclide studies showed that barium studies were positive in 25.6% and radionuclide studie...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.2.479

    authors: Heyman S,Kirkpatrick JA,Winter HS,Treves S

    更新日期:1979-05-01 00:00:00

  • Limitations of liver surface US in the diagnosis of cirrhosis.

    abstract::Ultrasound (US) of the liver surface with a high-frequency, small-parts, short-focused probe has been proposed as a method of diagnosing cirrhosis. US of the liver was performed in 50 consecutive patients undergoing diagnostic liver biopsy to assess the clinical usefulness of this noninvasive procedure in diagnosing h...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.185.1.1523310

    authors: Ladenheim JA,Luba DG,Yao F,Gregory PB,Jeffrey RB,Garcia G

    更新日期:1992-10-01 00:00:00

  • Computed tomography of the parotid gland during contrast sialography.

    abstract::By performing CT scanning during contrast sialography, tumors within the parotid gland can be shown and their configuration in relation to the remaining normal salivary gland and surrounding structures can be appreciated. This permits better evaluation of the relationship of the tumor to the facial nerve, possible ext...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.1.211

    authors: Mancuso A,Rice D,Hanafee W

    更新日期:1979-07-01 00:00:00

  • Survival outcomes of breast cancer patients who receive neoadjuvant chemotherapy: association with dynamic contrast-enhanced MR imaging with computer-aided evaluation.

    abstract:PURPOSE:To retrospectively evaluate whether dynamic contrast agent-enhanced (DCE) magnetic resonance (MR) imaging parameters assessed by a computer-aided evaluation program are associated with recurrence-free and overall survival in breast cancer patients who received neoadjuvant chemotherapy (NAC). MATERIALS AND METH...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13121801

    authors: Yi A,Cho N,Im SA,Chang JM,Kim SJ,Moon HG,Han W,Park IA,Noh DY,Moon WK

    更新日期:2013-09-01 00:00:00

  • Three-dimensional Deep Convolutional Neural Networks for Automated Myocardial Scar Quantification in Hypertrophic Cardiomyopathy: A Multicenter Multivendor Study.

    abstract::Background Cardiac MRI late gadolinium enhancement (LGE) scar volume is an important marker for outcome prediction in patients with hypertrophic cardiomyopathy (HCM); however, its clinical application is hindered by a lack of measurement standardization. Purpose To develop and evaluate a three-dimensional (3D) convolu...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2019190737

    authors: Fahmy AS,Neisius U,Chan RH,Rowin EJ,Manning WJ,Maron MS,Nezafat R

    更新日期:2020-01-01 00:00:00

  • Skeletal development in fetal pig specimens: MR imaging of femur with histologic comparison.

    abstract:PURPOSE:To evaluate the magnetic resonance (MR) imaging features of the developing femur in fetal pig specimens. MATERIALS AND METHODS:MR images of 15 fetal pig femurs, which were categorized into three groups of specimens representing each third of the gestational period, were used to compare increasing femoral lengt...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2332030131

    authors: Connolly SA,Jaramillo D,Hong JK,Shapiro F

    更新日期:2004-11-01 00:00:00

  • Evaluation of a 10-minute comprehensive MR imaging examination of the upper abdomen.

    abstract:PURPOSE:To determine whether a 10-minute magnetic resonance (MR) imaging examination of the upper abdomen provides sufficiently comprehensive information to replace a longer MR protocol. MATERIALS AND METHODS:Images obtained with selected breathing-independent and breath hold MR sequences, with 2 minutes of total acqu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.211.1.r99ap32189

    authors: Semelka RC,Balci NC,Op de Beeck B,Reinhold C

    更新日期:1999-04-01 00:00:00

  • Pathologic conditions in the small bowel: findings at fat-suppressed gadolinium-enhanced MR imaging with an optimized suspension of oral magnetic particles.

    abstract::Depiction of small-bowel pathologic conditions was optimized with use of a negative luminal contrast agent, spectral fat suppression, and gadolinium enhancement in an excised gut phantom. The method was applied in nine patients in conjunction with standard enteroclysis examinations. Bulk susceptibility effects of oral...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.1.9315000

    authors: Faber SC,Stehling MK,Holzknecht N,Gauger J,Helmberger T,Reiser M

    更新日期:1997-10-01 00:00:00

  • Prostate cancer: prediction of extracapsular extension with endorectal MR imaging and three-dimensional proton MR spectroscopic imaging.

    abstract:PURPOSE:To determine if the addition of three-dimensional (3D) proton magnetic resonance (MR) spectroscopic imaging to endorectal MR imaging helps diagnose extracapsular extension (ECE) of prostate cancer. MATERIALS AND METHODS:Endorectal MR imaging and 3D MR spectroscopic imaging were performed in 53 patients with pr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.213.2.r99nv26481

    authors: Yu KK,Scheidler J,Hricak H,Vigneron DB,Zaloudek CJ,Males RG,Nelson SJ,Carroll PR,Kurhanewicz J

    更新日期:1999-11-01 00:00:00

  • Mammography with synchrotron radiation: phase-detection techniques.

    abstract::The authors evaluated the effect on mammographic examinations of the use of synchrotron radiation to detect phase-perturbation effects, which are higher than absorption effects for soft tissue in the energy range of 15-25 keV. Detection of phase-perturbation effects was possible because of the high degree of coherence...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.215.1.r00ap10286

    authors: Arfelli F,Bonvicini V,Bravin A,Cantatore G,Castelli E,Palma LD,Michiel MD,Fabrizioli M,Longo R,Menk RH,Olivo A,Pani S,Pontoni D,Poropat P,Prest M,Rashevsky A,Ratti M,Rigon L,Tromba G,Vacchi A,Vallazza E,Zanconat

    更新日期:2000-04-01 00:00:00

  • Exophytic syrinx, an extreme form of syringomyelia: CT, myelographic, and MR imaging features.

    abstract::Magnetic resonance (MR) imaging and computed tomography (CT) were used to study severe syringomyelia, in which the syrinx was so eccentric relative to the center of the spinal cord that at initial examination it appeared to be an exophytic extramedullary mass, in five of six patients with type 2 Arnold-Chiari malforma...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.1.1549680

    authors: Heinz R,Curnes J,Friedman A,Oakes J

    更新日期:1992-04-01 00:00:00

  • Circular tomosynthesis: potential in imaging of breast and upper cervical spine--preliminary phantom and in vitro study.

    abstract::Phantom and in vitro studies were performed to evaluate the potential application of digital circular tomosynthesis in imaging of the breast and upper cervical spine. A prototype volumetric x-ray system was used to image a mammographic phantom, a fresh mastectomy specimen, and a head phantom containing the upper cervi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2282020295

    authors: Stevens GM,Birdwell RL,Beaulieu CF,Ikeda DM,Pelc NJ

    更新日期:2003-08-01 00:00:00

  • Capsular transgression of prostatic carcinoma: evaluation with transrectal US with pathologic correlation.

    abstract::One hundred twenty-five patients with biopsy proved clinical stage A or B prostatic carcinoma were evaluated with biplane transrectal ultrasonography (US) prior to radical prostatectomy. Sonograms were evaluated for capsular transgression of the tumor into the posterior and posterolateral aspects of the glands as mani...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.178.3.1994420

    authors: Hamper UM,Sheth S,Walsh PC,Holtz PM,Epstein JI

    更新日期:1991-03-01 00:00:00

  • Diagnostic value of spinal US: comparative study with MR imaging in pediatric patients.

    abstract:PURPOSE:To assess the diagnostic value of spinal ultrasonography (US) in pediatric patients. MATERIALS AND METHODS:The findings on 38 spinal US scans in 30 patients (mean age, 5.5 months) were compared with those of corresponding magnetic resonance (MR) images. RESULTS:MR imaging showed a normal spinal canal in 14 of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.200.2.8685330

    authors: Rohrschneider WK,Forsting M,Darge K,Tröger J

    更新日期:1996-08-01 00:00:00

  • Quantification of the left ventricular volumes and function with cine MR imaging: comparison of geometric models with three-dimensional data.

    abstract::Acquisition and measurement of left ventricular (LV) volumes with a three-dimensional data set of cine magnetic resonance (MR) images from apex to base is a time-consuming process. Results of a study with 10 healthy volunteers and 10 patients with LV hypertrophy were prospectively evaluated. The heart was shown in the...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.2.8327680

    authors: Dulce MC,Mostbeck GH,Friese KK,Caputo GR,Higgins CB

    更新日期:1993-08-01 00:00:00

  • Cervical spine tomography with an angiographic C-arm.

    abstract::Phantom studies were performed to develop a technique for linear tomography of the craniocervical junction with a digital fluoroscopic angiographic C-arm unit. Section thicknesses were similar to those used at conventional tomography, and the radiation dose was lower. C-arm tomography was possible with a 6-second expo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.211.3.r99jn02882

    authors: Ridpath CA,Wilson AJ,Langer SG,Mann FA,Hunter JC

    更新日期:1999-06-01 00:00:00

  • Comparison of the Reliability of Acoustic Radiation Force Impulse Imaging and Supersonic Shear Imaging in Measurement of Liver Stiffness.

    abstract:PURPOSE:To compare the reliability of acoustic radiation force impulse (ARFI) imaging and supersonic shear imaging (SSI) in measurement of liver stiffness. MATERIALS AND METHODS:This study was approved by the institutional review board, and written informed consent was obtained for all patients. Seventy-nine patients ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015141975

    authors: Woo H,Lee JY,Yoon JH,Kim W,Cho B,Choi BI

    更新日期:2015-12-01 00:00:00

  • Suspected acute pulmonary embolism: evaluation with multi-detector row CT versus digital subtraction pulmonary arteriography.

    abstract:PURPOSE:To determine diagnostic accuracy of four-channel multi-detector row computed tomography (CT) in emergency room and inpatient populations suspected of having acute pulmonary embolism (PE) who prospectively underwent both CT and pulmonary arteriography (PA). MATERIALS AND METHODS:Patients referred for PA to asse...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2333031744

    authors: Winer-Muram HT,Rydberg J,Johnson MS,Tarver RD,Williams MD,Shah H,Namyslowski J,Conces D,Jennings SG,Ying J,Trerotola SO,Kopecky KK

    更新日期:2004-12-01 00:00:00

  • Articular cartilage: correlation of histologic zones with signal intensity at MR imaging.

    abstract::Zones of high and low signal intensity on magnetic resonance (MR) images of articular cartilage were correlated with the four histologic zones normally found in such cartilage. Grossly normal articular cartilage from knees and ankles of a fresh cadaver were used in the study. The three zones identified on MR images in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.181.3.1947110

    authors: Modl JM,Sether LA,Haughton VM,Kneeland JB

    更新日期:1991-12-01 00:00:00

  • Characteristics of a first-generation x-ray system.

    abstract:PURPOSE:To compare the antiquated x-ray system of Hoffmans and van Kleef (circa 1896) with modern x-ray equipment in terms of radiation dose, x-ray beam properties, image quality, and electrical parameters. MATERIALS AND METHODS:The antiquated x-ray system consisted of a Ruhmkorff inductor, battery, and Crookes tube. ...

    journal_title:Radiology

    pub_type: 历史文章,杂志文章

    doi:10.1148/radiol.11101899

    authors: Kemerink M,Dierichs TJ,Dierichs J,Huynen HJ,Wildberger JE,van Engelshoven JM,Kemerink GJ

    更新日期:2011-05-01 00:00:00

  • Carotid artery invasion by head and neck masses: prediction with MR imaging.

    abstract:PURPOSE:To determine the value of magnetic resonance (MR) imaging in predicting resectability of head and neck neoplasms around the carotid arteries. MATERIALS AND METHODS:Forty-nine patients (28 male patients and 21 female patients aged 17-79 years; mean, 57.3 years) with head and neck masses and clinical evidence of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.3.7754000

    authors: Yousem DM,Hatabu H,Hurst RW,Seigerman HM,Montone KT,Weinstein GS,Hayden RE,Goldberg AN,Bigelow DC,Kotapka MJ

    更新日期:1995-06-01 00:00:00

  • Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: improved reliability with 14-gauge, directional, vacuum-assisted biopsy.

    abstract:PURPOSE:To compare histologic findings of atypical ductal hyperplasia (ADH) at 14-gauge, directional, vacuum-assisted breast biopsy (hereafter, vacuum-assisted biopsy) and at 14-gauge, automated, large-core breast biopsy (hereafter, large-core biopsy) with findings at histologic examination after surgical biopsy. MATE...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiology.204.2.9240540

    authors: Jackman RJ,Burbank F,Parker SH,Evans WP 3rd,Lechner MC,Richardson TR,Tocino I,Wray AB

    更新日期:1997-08-01 00:00:00

  • Percutaneous endoscopic cholecystolithotripsy. Work in progress.

    abstract::In spite of long-term adjunctive oral dissolution therapy, residual gallstones have been reported in up to 50% of gallstone patients 3 months after extracorporeal shock-wave lithotripsy. Six women and five men, aged 31-75 years, underwent percutaneous endoscopic cholecystolithotripsy between April 1988 and October 198...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.2.2678260

    authors: Hruby W,Stackl W,Urban M,Armbruster C,Marberger M

    更新日期:1989-11-01 00:00:00