Abstract:
:A prospective randomized study was set up, comparing a compression hip screw with the Vandeputte (VDP) endoprosthesis treatment for fresh, unstable peritrochanteric fractures, according to the Evans-Jensen and AO systems. Ninety patients, ages > or = 70 years, 47 of whom were treated with a compression hip screw and 43 with a VDP endoprosthesis, were included. All patients were being followed for 3 months. No difference between the two groups was found for operating time, wound complications, and mortality rate, but there was a higher transfusion need in VDP treatment. Severe fracture redisplacement or total collapse of the fracture occurred in 11 (26%) compression hip screw patients, two of whom had revision surgery. Only one patient needed reintervention after VDP treatment. Functional capacity of preoperative independent patients at hospital discharge did not differ for the two groups. In conclusion, the compression hip screw seemed to be an appropriate implant for most of the peritrochanteric fractures, but for very old patients with advanced osteoporosis, with a complex, unstable peritrochanteric fracture, and who are eligible for early mobilization, primary cemented endoprosthesis might be the best treatment.
journal_name
J Orthop Traumajournal_title
Journal of orthopaedic traumaauthors
Stappaerts KH,Deldycke J,Broos PL,Staes FF,Rommens PM,Claes Pdoi
10.1097/00005131-199509040-00004subject
Has Abstractpub_date
1995-01-01 00:00:00pages
292-7issue
4eissn
0890-5339issn
1531-2291journal_volume
9pub_type
临床试验,杂志文章,随机对照试验abstract:BACKGROUND:Traumatic spondylolisthesis of the axis, is a common cervical spine fracture; however, to date there is limited data available to guide the treatment of these injuries. The purpose of this review is to provide an evidence-based analysis of the literature and clinical outcomes associated with the surgical and...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000000952
更新日期:2017-09-01 00:00:00
abstract::Fracture healing is a unique multifaceted process requiring the presence of cells, molecular mediators, and angiogenic factors. The state of inflammation dominates the initial phase, but the ideal magnitude and duration of the process for an optimal outcome remains obscure. Biological response modifiers, such as plate...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0000000000000465
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVE:The aim of the current study was to see how different interlocking mechanisms would affect construct stability and overall failure in the treatment of two-part surgical neck fractures in the proximal humerus in vitro. METHODS:Left and right bones of eight pairs of fresh-frozen human cadaveric humeri were ass...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181ffdf9a
更新日期:2011-07-01 00:00:00
abstract:INTRODUCTION:External rotation and gravity stress radiographs have been described to distinguish stable supination-external rotation-II (SER-II) ankle fractures from unstable SER-IV fractures. It has been previously shown that both external rotation and gravity stress views are equivalent in their ability to diagnose d...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000817
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVE:New locked plate devices offer theoretical advantages for the treatment of supracondylar femur fractures associated with a total knee arthroplasty (TKA). These devices also can be inserted with relative ease by using minimally invasive techniques, provide a fixed angle construct, and improve fixation in osteo...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200603000-00005
更新日期:2006-03-01 00:00:00
abstract:OBJECTIVE:To evaluate the functional outcomes and pain in patients with unilateral posterior pelvic ring injuries treated with transiliac-transsacral screw fixation compared with unilateral iliosacral screw fixation. DESIGN:Retrospective comparative study. SETTING:Three academic level 1 trauma centers. PATIENTS/PART...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,多中心研究
doi:10.1097/BOT.0000000000000622
更新日期:2016-09-01 00:00:00
abstract::Results of hemiarthroplasty for complex four-part proximal humerus fractures in the elderly have been unreliable. Although patients often achieve pain relief, return of above-shoulder level function can be challenging, because tuberosity nonunion, malunion, and/or resorption is quite common. The reverse shoulder repla...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181f22088
更新日期:2011-05-01 00:00:00
abstract:OBJECTIVE:To quantify intrapelvic surface symmetry in reference to a preshaped suprapectineal acetabular implant. METHODS:In this cross-sectional study, an anatomically preshaped acetabular fracture implant was fitted on 3D surface models of 516 pelvises from a preexisting bone database using a software tool for autom...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001373
更新日期:2019-03-01 00:00:00
abstract:OBJECTIVE:Screw fixation of the injured syndesmosis restores stability but may reduce motion. The purpose of this study is to determine whether functional outcomes and radiographic results after ankle fracture are affected by the status of the syndesmosis screw. DESIGN:Retrospective review of a consecutive clinical se...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181a9f7a5
更新日期:2010-01-01 00:00:00
abstract:BACKGROUND:Acceptable amounts of malrotation after CRPP for pediatric supracondylar humerus fracture (SCHFx) have yet to be defined. This is an attempt to correlate radiographic parameters of a malrotated SCHFx with degrees of rotational malalignment to assist intraoperative assessment of reduction. METHODS:3D models ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001735
更新日期:2020-07-01 00:00:00
abstract::Recent innovations have greatly increased the range of proximal humeral fractures that are amenable to open reduction and plate fixation.The optimum technique for some of the more complex fracture patterns is not yet fully refined.This article aims to describe the recent advances in the treatment of complex proximal h...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章,评审
doi:10.1097/BOT.0b013e31821c0a2f
更新日期:2011-10-01 00:00:00
abstract:OBJECTIVES:Evaluate the effect of the COVID-19 pandemic and the "shelter-in-place" order on orthopaedic trauma presenting to a community level II trauma center. It is hypothesized the overall number of orthopaedic trauma encounters (OTE), the number of OTEs related to both high and low severity injuries, as well as the...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001860
更新日期:2020-06-08 00:00:00
abstract::Periprosthetic humerus fractures are relatively uncommon occurrence that can be difficult to manage nonoperatively. Locking plate technology has enhanced the surgical management of these fractures. However, adequate fixation around the stem remains of some concern. We describe an osteosynthesis technique using a locki...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000646
更新日期:2016-11-01 00:00:00
abstract:OBJECTIVES:To determine how often preoperative testing is requested for geriatric hip fracture patients, to assess the extent to which preoperative testing is associated with delayed surgery, and to measure the frequency with which preoperative testing changes patient management. DESIGN:Retrospective. SETTING:Academi...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000444
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVE:To compare the mechanical stability of fixation of an unstable bicondylar tibial plateau fracture with several different fixation techniques in a cadaveric model. DESIGN:Randomized laboratory investigation using a simulated bicondylar tibial plateau fracture with metaphyseal-diaphyseal dissociation. SETTING...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00005131-199911000-00005
更新日期:1999-11-01 00:00:00
abstract::We reviewed 13 cases of unstable cervical spine treated by stabilization with posterior Roy-Camille plates and fusion. The patients were treated between 1985-1988. Six patients had acute traumatic episodes, three patients had posttraumatic instabilities, one patient had laminectomy for cervical spondylotic myelopathy,...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-198903010-00005
更新日期:1989-01-01 00:00:00
abstract:OBJECTIVE:To evaluate and compare the mechanical stability of two different fixation techniques on experimentally induced calcaneus fractures. METHODS:Thirteen fresh frozen cadaver lower limbs had intraarticular calcaneal fractures produced with an impact loading device. Internal fixation was then performed through la...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199708000-00010
更新日期:1997-08-01 00:00:00
abstract:OBJECTIVES:To compare reports of implant fatigue failure submitted to the FDA of 2 commonly used cephalomedullary nails. METHODS:In total, 2724 medical device reports from the FDA's MAUDE database from Jan 2015 to Oct 2019 were reviewed for the Trochanteric Femoral Nail-Advanced (TFNa) and Gamma 3 implants. RESULTS:D...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000001864
更新日期:2021-02-01 00:00:00
abstract:OBJECTIVE:To determine the prognostic reliability, sensitivity, and specificity of the Hawkins sign. The Hawkins sign is a subchondral radiolucent band in the talar dome that is indicative of viability at 6 to 8 weeks after a talus fracture. It is visible in the anterior-posterior view, but seldom appears on lateral ra...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e318148c665
更新日期:2007-09-01 00:00:00
abstract:OBJECTIVE:To study the effect of tourniquet control on intramedullary reaming. DESIGN:An experimental prospective nonsurvival animal study was performed using 5 mongrel dogs. A pneumatic tourniquet was randomized to either the right or left hind limb. Tibial intramedullary reaming was performed with progressively larg...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200411000-00004
更新日期:2004-11-01 00:00:00
abstract::In a 3-year prospective randomized trial, the prognostic value of osteoporosis in terms of predicting healing complications due to implant failures or loss of fracture reduction has been studied in 113 patients with inter-trochanteric hip fractures treated with either a sliding screwplate or Ender nailing. According t...
journal_title:Journal of orthopaedic trauma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00005131-199310000-00006
更新日期:1993-01-01 00:00:00
abstract::The current literature tends to favor rigid internal fixation with plates for symptomatic midclavicular nonunions. From 1985 to 1992, 14 patients with clavicular nonunions were treated by open reduction and intramedullary Steinman pin fixation with onlay iliac crest bone grafting. The average age of patients was 36 ye...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199404000-00002
更新日期:1994-01-01 00:00:00
abstract:OBJECTIVES:Hand dominance has been reported to be an important factor affecting outcomes after upper extremity trauma but remains unstudied after hemiarthroplasty for fracture. This study determined whether dominance affected outcomes after hemiarthroplasty for proximal humerus fractures. DESIGN:Retrospective cohort s...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000294
更新日期:2015-08-01 00:00:00
abstract:OBJECTIVE:Evaluate the ability of osteogenic protein-1 to induce formation of de novo bone in the presence of bacterial infection and metal in an intramuscular osteoinduction model in the rat. DESIGN:Prospective experimental design with assessment time points of up to 4 weeks. SETTING:Intramuscular pocket surgically ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-200408000-00008
更新日期:2004-08-01 00:00:00
abstract:OBJECTIVE:To assess surgical and functional results after corrective reconstruction of malunited, scapula neck or body fractures in patients who presented with chronic pain, limited range of motion, weakness, and gross deformity of the shoulder. DESIGN:Case series. SETTING:Level I teaching trauma center. PATIENTS:Be...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31820af67f
更新日期:2011-11-01 00:00:00
abstract::This report presents a case demonstrating the nonunion of a capital femoral physeal fracture with a large metaphyseal fragment in a 10-year-old boy. To our knowledge, there is no previously reported case of this type of nonunion. The treatment of this nonunion presented a potential risk of premature physeal closure an...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e3181c83a3b
更新日期:2010-08-01 00:00:00
abstract::Standard 5-mm AO Schanz pedicle screws were biomechanically compared with a new design, featuring 6-mm threads with a 5-mm core diameter continuous with the shaft. One each of the two screw designs was surgically inserted into the matching pedicles of 32 cadaveric vertebrae. The pull-out strengths of the screws were t...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199308000-00015
更新日期:1993-01-01 00:00:00
abstract:OBJECTIVE:To report the results from functional bracing of isolated ulnar shaft fractures. DESIGN:Retrospective review. SETTING:Two university hospitals. PATIENTS:Isolated ulnar shaft fractures in 444 patients were stabilized in functional braces that permitted full range of motion of all joints. INTERVENTION:Prefa...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/00005131-199808000-00009
更新日期:1998-08-01 00:00:00
abstract::In the current health care environment, cost containment is more important than ever. Most physicians currently are unaware of the cost of operating room supplies. A large amount of waste occurs secondary to lack of knowledge and absence of physician incentives for cost saving. Many of the decisions for supply use can...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0000000000000718
更新日期:2016-12-01 00:00:00
abstract:OBJECTIVE:To report our experience with computed tomography (CT) scans to detect traumatic arthrotomies of the knee (TAK) joint based on the presence of intra-articular air. DESIGN:Retrospective review. SETTING:Level I trauma center. PATIENTS:Sixty-two consecutive patients (63 knees) underwent a CT scan of the knee ...
journal_title:Journal of orthopaedic trauma
pub_type: 杂志文章
doi:10.1097/BOT.0b013e31828219bc
更新日期:2013-09-01 00:00:00