Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis.

Abstract:

:In a 3-year prospective randomized trial, the prognostic value of osteoporosis in terms of predicting healing complications due to implant failures or loss of fracture reduction has been studied in 113 patients with inter-trochanteric hip fractures treated with either a sliding screwplate or Ender nailing. According to the Barnet and Nordin's osteoporosis index, 66 patients were considered to have moderate or severe osteoporosis. There were no differences between patients with or without osteoporosis as regards the number of fractures with collapse in varus > 10 degrees, redislocation > 10 mm, or compression exceeding 10 mm. Six months after surgery, 48 patients failed in healing or healed with complications. These cases disclosed increased osteoporosis in comparison with those showing noncomplicated healing. Patients with osteoporosis who had unstable fractures treated by Ender nailing were found to have the worst prognosis for healing complications (p = 0.006). Of the 33 fractures with implant failures, 25 (76%) occurred in patients with osteoporosis (p = 0.04). In patients with osteoporosis, the frequency of mechanical failures was significantly higher in fractures with the device positioned incorrectly. Independently of the device used, patients with unstable trochanteric hip fractures and osteoporotic bone were the group with the highest risk for failures of the implant.

journal_name

J Orthop Trauma

authors

Barrios C,Broström LA,Stark A,Walheim G

doi

10.1097/00005131-199310000-00006

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

438-42

issue

5

eissn

0890-5339

issn

1531-2291

journal_volume

7

pub_type

临床试验,杂志文章,随机对照试验
  • Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.

    abstract:OBJECTIVES:To introduce a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for acute displaced humeral shaft fractures and to evaluate the clinical and radiological outcomes. DESIGN:: Prospective clinical series study. SETTING:University hospital. PATIENTS:Twenty-one patients with acut...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318254895f

    authors: Shin SJ,Sohn HS,Do NH

    更新日期:2012-10-01 00:00:00

  • Use of the reamer irrigator aspirator for the treatment of a 20-year recurrent osteomyelitis of a healed femur fracture.

    abstract:SUMMARY:In the following case, a 20-year-old male was involved in a motorcycle accident where he sustained an open midshaft femur fracture treated with open reduction and internal fixation. Several weeks later, the wound became infected and the plate was removed. Over the following 20 years numerous incision and debrid...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318051532d

    authors: Bellapianta J,Gerdeman A,Sharan A,Lozman J

    更新日期:2007-05-01 00:00:00

  • Low-energy femoral shaft fractures associated with alendronate use.

    abstract:OBJECTIVE:Increasing evidence suggests long-term alendronate use may overly suppress bone metabolism, limiting repair of microdamage and creating risk for insufficiency fractures. The purpose of this study is to demonstrate an association between alendronate use and a specific pattern of low-energy femoral shaft fractu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318172841c

    authors: Neviaser AS,Lane JM,Lenart BA,Edobor-Osula F,Lorich DG

    更新日期:2008-05-01 00:00:00

  • Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.

    abstract:OBJECTIVE:The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically si...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31826f5985

    authors: Domby B,Henderson E,Nayak A,Erdoğan M,Gutierrez S,Santoni BG,Sagi HC

    更新日期:2012-12-01 00:00:00

  • Stereo fluoroscopy-assisted distal interlocking of intramedullary nails.

    abstract::A simulation study of distal interlocking of an intramedullary nail was performed using newly devised, portable stereo fluoroscopy. Two intramedullary nails in which ten holes were drilled perpendicular to the long axis and at various angles to the diameter were inserted into a femoral and a tibial bone model. Ten dri...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199705000-00014

    authors: Ohe T,Nakamura K,Matsushita T,Nishiki M,Watanabe N,Matsumoto K

    更新日期:1997-05-01 00:00:00

  • The Community Orthopaedic Surgeon Taking Trauma Call: Lateral Humeral Condyle Fracture Pearls and Pitfalls.

    abstract::Lateral condyle fractures are second only to supracondylar humeral fractures when it comes to pediatric elbow fractures. Whether minimally displaced or substantially displaced, these growth plate fractures may present significant treatment challenges. These include nonunion, malunion, avascular necrosis, and growth di...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000001543

    authors: Ho CA,Mehlman CT

    更新日期:2019-08-01 00:00:00

  • Navigated femoral nailing using noninvasive registration of the contralateral intact femur to restore anteversion. Technique and clinical use.

    abstract::The difficulty in assessing femoral rotation during intramedullary nailing is well-established. Navigation systems allow the surgeon to detect and set the version of the injured leg at the desired angle. We report the first cases of navigated femoral nailing using noninvasive registration of the contralateral uninjure...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31812f69a9

    authors: Kendoff D,Citak M,Gardner MJ,Gösling T,Krettek C,Hüfner T

    更新日期:2007-11-01 00:00:00

  • Debridement of cancellous bone: a comparison of irrigation methods.

    abstract:OBJECTIVE:This study tests the bone debridement efficacy and damage to cancellous bone produced by different wound irrigation methods. METHODS:Cancellous bone slices of bovine distal femurs (3 cm x 3 cm) were divided into eight test groups and scored with a saw in a latticed pattern. Four test groups were contaminated...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31802b41e2

    authors: Draeger RW,Dirschl DR,Dahners LE

    更新日期:2006-11-01 00:00:00

  • Alleviation of Pain After Femur and Tibia Shaft Fractures Using Nothing Stronger Than Codeine and Tramadol.

    abstract:OBJECTIVE:To determine whether using nothing stronger than codeine and tramadol provides adequate pain alleviation in people recovering from fixation of a fracture of the femur or tibia shaft. DESIGN:Retrospective case series. SETTING:Level 1 trauma center in the United States. PATIENTS:All adult patients from Octob...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001683

    authors: Reich MS,Klahs KJ,Fernandez I,Nguyen MP

    更新日期:2020-02-01 00:00:00

  • Isolated ulnar shaft fractures treated with functional braces.

    abstract:OBJECTIVE:To report the results from functional bracing of isolated ulnar shaft fractures. DESIGN:Retrospective review. SETTING:Two university hospitals. PATIENTS:Isolated ulnar shaft fractures in 444 patients were stabilized in functional braces that permitted full range of motion of all joints. INTERVENTION:Prefa...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199808000-00009

    authors: Sarmiento A,Latta LL,Zych G,McKeever P,Zagorski JP

    更新日期:1998-08-01 00:00:00

  • Preinjury Narcotic Use Does Not Affect Treatment for Compartment Syndrome.

    abstract:OBJECTIVES:To determine the association of preinjury opioid use on incidence of fasciotomy after lower extremity trauma. DESIGN:Retrospective case-control study. SETTING:Level 1 trauma center. PATIENTS/PARTICIPANTS:We identified 245 consecutive patients treated with fasciotomy for compartment syndrome of the lower e...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001650

    authors: Chen SR,Abblitt WP,Knoll OM,Cooper SA,Backstrom ZK,Jahangir AA,Sethi MK

    更新日期:2020-03-01 00:00:00

  • Efficacy of popliteal block in postoperative pain control after ankle fracture fixation: a prospective randomized study.

    abstract:OBJECTIVES:To compare postoperative pain control in patients treated surgically for ankle fractures who receive popliteal blocks with those who received general anesthesia alone. DESIGN:Institutional Review Board approved prospective randomized study. SETTING:Metropolitan tertiary-care referral center. PATIENTS:All ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0b013e3182638b25

    authors: Goldstein RY,Montero N,Jain SK,Egol KA,Tejwani NC

    更新日期:2012-10-01 00:00:00

  • Connective tissue parameters in experimental nonunion.

    abstract::A previously developed experimental model for producing nonunions in rats was used to study the biochemical changes of connective tissue parameters in impaired fracture repair. The model is based on rotational instability between the fracture fragments. A mid-diaphyseal femoral osteotomy was performed on 30 male rats ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199602000-00007

    authors: Hietaniemi K,Paavolainen P,Penttinen R

    更新日期:1996-01-01 00:00:00

  • The Effect of Transiliac-Transsacral Screw Fixation for Pelvic Ring Injuries on the Uninjured Sacroiliac Joint.

    abstract:OBJECTIVE:To evaluate the functional outcomes and pain in patients with unilateral posterior pelvic ring injuries treated with transiliac-transsacral screw fixation compared with unilateral iliosacral screw fixation. DESIGN:Retrospective comparative study. SETTING:Three academic level 1 trauma centers. PATIENTS/PART...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000000622

    authors: Mardam-Bey SW,Beebe MJ,Black JC,Chang EY,Kubiak EN,Bishop JA,McAndrew CM,Ricci WM,Gardner MJ

    更新日期:2016-09-01 00:00:00

  • False positive indium-111 white blood cell scan in a closed clavicle fracture.

    abstract::Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagn...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:

    authors: Friedman RJ,Gordon L

    更新日期:1988-01-01 00:00:00

  • Functional outcomes in women after high-energy pelvic ring injury.

    abstract:OBJECTIVES:Residual dysfunction after pelvic trauma has been previously described, but limited functional outcome data are available in the female population after high-energy pelvic ring injury. The purposes of this study were to determine functional outcomes and to characterize factors predictive of outcome. DESIGN:...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318221e94e

    authors: Vallier HA,Cureton BA,Schubeck D,Wang XF

    更新日期:2012-05-01 00:00:00

  • Stabilization of pediatric diaphyseal femur fractures with flexible intramedullary nails (a technique paper).

    abstract::The indications for surgical stabilization of a pediatric diaphyseal femur fracture are expanding. Children with multiple system injuries, a head injury, and/or multiple fractures have fewer local and distant complications if the femur fracture is treated operatively. Other indications include a pathological fracture ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199212000-00011

    authors: Heinrich SD,Drvaric D,Darr K,MacEwen GD

    更新日期:1992-01-01 00:00:00

  • Superior Outcomes After Operative Fixation of Patella Fractures Using a Novel Plating Technique: A Prospective Cohort Study.

    abstract:OBJECTIVE:The purpose of this prospective cohort study was to determine if a new patella fracture fixation construct resulted in improved outcomes compared with traditional tension band techniques. DESIGN:Comparative cohort study. SETTING:Academic level I trauma center. PATIENTS/PARTICIPANTS:Patients with isolated, ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000787

    authors: Lorich DG,Fabricant PD,Sauro G,Lazaro LE,Thacher RR,Garner MR,Warner SJ

    更新日期:2017-05-01 00:00:00

  • Quantification of the upper and second sacral segment safe zones in normal and dysmorphic sacra.

    abstract:OBJECTIVES:To quantify the obliquity and dimensions of the upper and second sacral segment iliosacral screw safe zones and to determine the differences between normal and dysmorphic sacral morphology. DESIGN:Retrospective cohort. SETTING:University Level I trauma center. PATIENTS/PARTICIPANTS:Fifty patients with pel...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181cf0404

    authors: Gardner MJ,Morshed S,Nork SE,Ricci WM,Chip Routt ML Jr

    更新日期:2010-10-01 00:00:00

  • Reverse shoulder prosthesis for acute four-part fracture: tuberosity fixation using a horseshoe graft.

    abstract::Results of hemiarthroplasty for complex four-part proximal humerus fractures in the elderly have been unreliable. Although patients often achieve pain relief, return of above-shoulder level function can be challenging, because tuberosity nonunion, malunion, and/or resorption is quite common. The reverse shoulder repla...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181f22088

    authors: Levy JC,Badman B

    更新日期:2011-05-01 00:00:00

  • Treatment of displaced, proximal, humeral, epiphyseal fractures with a two-prong splint.

    abstract::To evaluate the use of a two-prong splint for displaced, proximal, humerus, epiphyseal fractures, seven children with Neer-Horwitz Classification Type 3-4 fractures of the proximal humerus were retrospectively investigated. After closed reduction, fracture stabilization was accomplished with the use of a two-prong spl...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200309000-00007

    authors: Karatosun V,Unver B,Alici E,Serin E

    更新日期:2003-09-01 00:00:00

  • Traumatic anterior dislocation of the radial head in an adult.

    abstract::We report an isolated anterior dislocation of the radial head in an adult after sustaining a fall on the outstretched arm. Based on history and presentation, we speculate that the injury occurred in a position of hyperextension and supination. Reduction was achieved by a pronation maneuver. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199505000-00014

    authors: Bonatus T,Chapman MW,Felix N

    更新日期:1995-01-01 00:00:00

  • Pelvic emergency clamps: anatomic landmarks for a safe primary application.

    abstract::The application of the pelvic clamp as a tool for emergency stabilization of unstable pelvic ring fractures has proved to be a life-saving procedure. Using correct technique, the pelvic clamp can be applied within a few minutes after the patient's admission. To avoid severe complications (eg, pin perforation into the ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200402000-00008

    authors: Pohlemann T,Braune C,Gänsslen A,Hüfner T,Partenheimer A

    更新日期:2004-02-01 00:00:00

  • Observed and expected outcomes in transfer and nontransfer patients with a hip fracture.

    abstract:OBJECTIVES:Hospitals and providers that accept transfer patients risk lower ratings on publically reported quality measures that are inadequately adjusted for infirmity and complexity. We compared the outcomes of transferred patients and nontransferred patients after treatment of a hip fracture and sought to determine ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31821146b1

    authors: Wiggers JK,Guitton TG,Smith RM,Vrahas MS,Ring D

    更新日期:2011-11-01 00:00:00

  • Improving business IQ in medicine through mentorship and education.

    abstract::Business intelligence in the field of medicine, particularly with physicians, has been an abstract concept at best with no objective metric. Furthermore, in many arenas, it was taboo for medical students, residents, and physicians to discuss the business and finances of their work for fear that it would interfere with...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000177

    authors: Hill AD

    更新日期:2014-09-01 00:00:00

  • Getting organized in your job.

    abstract::The benefits of being organized when starting one's career are countless and worth the time and effort in developing an effective and efficient practice. Established protocols, good habits, and methodical communication that include all members of the team will help create a system that keeps all components of one's pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a52344

    authors: Siegel J

    更新日期:2013-10-01 00:00:00

  • Surgeons and their patients disagree regarding cosmetic and overall outcomes after surgery for high-energy lower extremity trauma.

    abstract:OBJECTIVES:To determine whether surgeons' and patients' perceptions of outcomes after high-energy lower-extremity trauma are similar and to identify factors associated with disagreement. DESIGN:Prospective study. SETTING:Eight level 1 trauma centers. PATIENTS:Four hundred sixty-three patients treated for limb-threat...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0b013e3181ab2c90

    authors: O'Toole RV,Castillo RC,Pollak AN,MacKenzie EJ,Bosse MJ,LEAP Study Group.

    更新日期:2009-11-01 00:00:00

  • The Incidence of Posterior Malleolar Involvement in Distal Spiral Tibia Fractures: Is it Higher than We Think?

    abstract:OBJECTIVES:To investigate the incidence of concomitant posterior malleolar fractures (PMFs) in operative, distal-third, spiral tibia fractures. DESIGN:Prospective protocol with retrospective review of data. SETTING:Single, Level 1 trauma center. PATIENTS/PARTICIPANTS:One hundred ninety-three consecutive, skeletally ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001307

    authors: Sobol GL,Shaath MK,Reilly MC,Adams MR,Sirkin MS

    更新日期:2018-11-01 00:00:00

  • Complications of nailing in closed tibial fractures.

    abstract::Reamed intramedullary nailing was used to treat 102 closed tibial shaft fractures. Although a high rate of union was achieved (98%), we noted a higher incidence of complications than previously reported. Thirty-five (37%) patients exhibited one or more components of malunion. In 17 (18%) patients, further operative pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199509060-00004

    authors: Williams J,Gibbons M,Trundle H,Murray D,Worlock P

    更新日期:1995-01-01 00:00:00

  • A biomechanical study of three wiring techniques for cerclage-plating.

    abstract::Transverse fractures at the distal tip of a well-fixed femoral prosthesis are difficult to stabilize using plates and screws due to the presence of the underlying intramedullary stem. The attachment of plates using cerclage wires obviates the need for screws, but the stability provided by cerclage plating is a clinica...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199505000-00004

    authors: Stevens SS,Irish AJ,Vachtsevanos JG,Csongradi J,Beaupré GS

    更新日期:1995-01-01 00:00:00