A comparison of three methods for the estimation of capillary blood glucose in filter paper spots.

Abstract:

:A comparison has been made between three methods for measuring capillary blood glucose collected on filter paper, including a new method using a Beckman glucose analyser 2. The methods are suitable for use with capillary blood spots collected onto filter paper for monitoring the control of diabetic patients. Their accuracy, precision, and recovery of glucose were similar. Glucose measurement with the Beckman glucose analyser 2 involves elution of the dried blood spots with 2% trichloroacetic acid and injection of a fraction of the eluate into the analyser. The method provides a simple and rapid alternative procedure for laboratories that do not have a heavy workload for this type of assay.

journal_name

Ann Clin Biochem

authors

Taylor RP,Pennock CA

doi

10.1177/000456328201900105

subject

Has Abstract

pub_date

1982-01-01 00:00:00

pages

22-5

issue

Pt 1

eissn

0004-5632

issn

1758-1001

journal_volume

19

pub_type

杂志文章
  • Alkaline phosphatase activity measurement in the UK by AMP-buffered methods: an appraisal of current practice.

    abstract::Most UK clinical laboratories use alkaline phosphatase (ALP) methods similar to that proposed by the International Federation of Clinical Chemistry (IFCC), based on the use of 2-amino-2-methyl-1-propanol (AMP) buffer. We present evidence of significant differences in results produced by apparently similar commercial A...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329803500117

    authors: Lamb EJ,Browne M,John WG,Price CP

    更新日期:1998-01-01 00:00:00

  • An automated method for the analysis of urinary free catecholamines using ASTED and high-pressure liquid chromatography.

    abstract::A high-pressure liquid chromatography procedure for the measurement of free catecholamines in urine is described. 'On-line' sample preparation using a cartesian robot combined with the ASTED process ensures minimal operator intervention and reduced costs. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600412

    authors: Green B,Cooper JD,Turnell DC

    更新日期:1989-07-01 00:00:00

  • The ratio of erythrocyte zinc-protoporphyrin to protoporphyrin IX in disease and its significance in the mechanism of lead toxicity on haem synthesis.

    abstract::Protoporphyrin and zinc-protoporphyrin were measured in the erythrocytes of normal subjects, workers exposed to lead and patients with iron deficiency and erythropoietic protoporphyria (EPP). Results showed significantly higher levels of zinc-protoporphyrin in the lead-exposed workers (P < 0.0001), patients with iron ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329803500313

    authors: Nelson JC,Westwood M,Allen KR,Newton KE,Barth JH

    更新日期:1998-05-01 00:00:00

  • Serum binding of steroid tracers and its possible effects on direct steroid immunoassay.

    abstract::We studied the serum protein binding of 3H-labelled progesterone, oestradiol and testosterone, and five 125I-labelled analogues of these steroids. All tracers investigated appeared to be bound by proteins in every serum sample tested. The addition of blocking agents caused a substantial reduction in serum protein bind...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329503200609

    authors: Micallef JV,Hayes MM,Latif A,Ahsan R,Sufi SB

    更新日期:1995-11-01 00:00:00

  • Plasma alkaline phosphatase activity and its relation to rickets in pre-term infants.

    abstract::Sequential measurements of plasma alkaline phosphatase activity were made in 84 pre-term infants delivered before 38 weeks gestation. In 67% of infants, without evidence of rickets but in whom three or more measurements were made and the peak activity was less than 10 times the adult reference range, the activity rose...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328602300604

    authors: Walters EG,Murphy JF,Henry P,Gray OP,Elder GH

    更新日期:1986-11-01 00:00:00

  • The case of stainless statins.

    abstract::Two cases of hypercholesterolaemic patients are presented in whom raised plasma creatine kinase was noted during treatment with statins. The plasma creatine kinase failed to fall following cessation of therapy. Further investigation revealed the aetiology of the raised plasma creatine kinase to be due to previously un...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456303322326542

    authors: Barth JH,Brownjohn AM,Jamieson DR

    更新日期:2003-09-01 00:00:00

  • Assay of glycosylated haemoglobin using agar electrophoresis.

    abstract::A fast electrophoretic method for measuring glycosylated haemoglobin (HbA1) is described. Eight samples per cell can be assayed in a single run. Results are compatible with those found by macro-column cation-exchange chromatography; precision is good. The practical short-comings of the commercially ready-made mini-col...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328101800310

    authors: Thornton WE,Schellekens AP,Sanders GT

    更新日期:1981-05-01 00:00:00

  • Evaluation of menstrual cycle-related changes in 85 clinical laboratory analytes.

    abstract:OBJECTIVE:The menstrual cycle-related changes in clinical laboratory values were analysed by use of data obtained in the Asian multicentre study aimed at derivation of common reference intervals for 85 major clinical laboratory tests. METHODS:Among 1876 healthy female volunteers, 893 had regular menstruation. They wer...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215617212

    authors: Masuda S,Ichihara K,Yamanishi H,Hirano Y,Tanaka Y,Kamisako T,Scientific Committee for Asia-Pasific Federation of Clinical Biochemistry.

    更新日期:2016-05-01 00:00:00

  • The significance of serum troponin T in patients with kidney disease: a review of the literature.

    abstract::The last 10 years have witnessed radical changes in the definition and diagnosis of the acute coronary syndrome (ACS), including myocardial infarction, as a result of the introduction of sensitive and specific markers of myocardial damage, the cardiac troponins. One barrier to the universal acceptance of these markers...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1258/000456304322664645

    authors: Lamb EJ,Webb MC,Abbas NA

    更新日期:2004-01-01 00:00:00

  • Evaluation and clinical application of a two-site immunoradiometric assay for alpha-1-foetoprotein using readily available reagents.

    abstract::The development and evaluation in routine clinical practice of a simple, rapid, high-throughput, immunoradiometric assay (IRMA) for alpha-foetoprotein (AFP) in serum and amniotic fluid is described. The assay uses readily available reagents; a radioiodinated mouse monoclonal antibody produced by the authors and the im...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328702400411

    authors: Stevenson JD,Chapman RS,Perry B,Logue FC

    更新日期:1987-07-01 00:00:00

  • Rapidly rule out acute myocardial infarction by combining copeptin and heart-type fatty acid-binding protein with cardiac troponin.

    abstract:BACKGROUND:The rapid exclusion of acute myocardial infarction in patients with chest pain can reduce the length of hospital admission, prevent unnecessary diagnostic work-up and reduce the burden on our health-care systems. The combined use of biomarkers that are associated with different pathophysiological aspects of ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215578189

    authors: Jacobs LH,van Borren M,Gemen E,van Eck M,van Son B,Glatz JF,Daniels M,Kusters R

    更新日期:2015-09-01 00:00:00

  • Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter.

    abstract::The effect of ambient temperature on the analytical and clinical performance of a glucose meter was examined. A total of 114 venous whole blood samples were analysed for glucose by a reference method, and by a glucose meter at 21-22 degrees C, room temperatures, 26-27 degrees C and 33-34 degrees C. Glucose meter readi...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563011901091

    authors: Nawawi H,Sazali BS,Kamaruzaman BH,Yazid TN,Jemain AA,Ismail F,Khalid BA

    更新日期:2001-11-01 00:00:00

  • Prevalence of macroamylasaemia using polyethylene glycol precipitation as a screening method.

    abstract::Four hundred and fifty-four subjects with hyperamylasaemia were screened for the presence of macroamylase using polyethylene glycol precipitation (PEG) and the Beckman automated amylase assay based on the hydrolysis of maltotetraose. Twenty-five subjects (5.5%) exhibited PEG precipitation values suggestive of macroamy...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563011900263

    authors: Lawson GJ

    更新日期:2001-01-01 00:00:00

  • Influence of age, posture and intra-individual variation on plasma levels of atrial natriuretic peptide.

    abstract::This paper describes some factors to which attention should be paid when atrial natriuretic peptide (ANP) values are to be interpreted. Changing from the supine to the sitting position decreased ANP levels, while no further decrease was observed when the upright position was assumed. On the other hand, plasma renin ac...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600604

    authors: Tan AC,Kloppenborg PW,Benraad TJ

    更新日期:1989-11-01 00:00:00

  • Intraindividual variation in serum thyroid hormones, parathyroid hormone and insulin-like growth factor-1.

    abstract:BACKGROUND:Biological variation of an analyte is an important determinant of its usefulness. Intraindividual variation in serum thyroid hormones, parathyroid hormone (PTH) and insulin-like growth factor-1 (IGF-1) in healthy subjects was determined in this study. METHODS:Blood samples were taken at weekly intervals for...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2007.007103

    authors: Ankrah-Tetteh T,Wijeratne S,Swaminathan R

    更新日期:2008-03-01 00:00:00

  • Why the assay of serum cystine by protein precipitation and chromatography should be abandoned.

    abstract::The higher bias of serum cystine estimations by a HPLC method compared with those by ion exchange techniques is shown to be largely due to differences in the sample preparation procedures of the two techniques. The ion exchange methods utilised sulphosalicylic acid serum protein precipitation and post-column ninhydrin...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328802500516

    authors: Cooper JD,Turnell DC,Green B,Wright DJ,Coombes EJ

    更新日期:1988-09-01 00:00:00

  • Bloodspot testosterone assay suitable for study of neonates and monitoring of children with congenital adrenal hyperplasia.

    abstract::A bloodspot assay for testosterone has been developed using an antiserum raised against testosterone-3-carboxymethyloxime-bovine serum albumin (T-3 CMO-BSA) conjugate and 125I-T-3CMO-histamine tracer. The method has a detection limit of 0.4 nmol/L with between-batch precision of less than 15% for testosterone values b...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329903600411

    authors: Walker J,Hughes IA,Wood PJ

    更新日期:1999-07-01 00:00:00

  • A new method of measuring the antioxidant activity of polyphenols using cumene hydroperoxide.

    abstract:BACKGROUND:It is well known that polyphenols lower the risk of chronic diseases such as heart disease and cancer. We describe a new method using cumene hydroperoxide (CHP) to determine the antioxidant activity of polyphenols. CHP is considered to be a model reactive lipid peroxidation product. METHODS:The method was b...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456304322664744

    authors: Sugita O,Ishizawa N,Matsuto T,Okada M,Kayahara N

    更新日期:2004-01-01 00:00:00

  • A rapid method for measuring serum amyloid A protein by latex agglutination nephelometric immunoassay.

    abstract::Serum amyloid A protein (SAA) is a sensitive acute phase reactant. We developed a method for the rapid measurement of human SAA in serum by kinetic nephelometry of anti-SAA antibody-coated latex agglutination. Measurement takes less than 6 min using an automated analyser. Standardization of the assay employs SAA-enric...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329303000112

    authors: Yamada T,Nomata Y,Sugita O,Okada M

    更新日期:1993-01-01 00:00:00

  • Prognostic evaluation of serum long non-coding RNA H19 for endoscopic keyhole surgery or craniotomy in glioma.

    abstract:BACKGROUND:Our study aims to explore the effect of serum long non-coding RNA (lncRNA) H19 level on the long-term prognosis of endoscopic keyhole surgery or craniotomy for glioma. METHODS:A total of 264 glioma patients were selected. Patients were randomly divided into the Craniotomy-high H19 group, the Craniotomy-low ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563220941888

    authors: Shen L,Xu M,Wang Z,Yu Z

    更新日期:2020-09-01 00:00:00

  • Microalbuminuria in type 2 diabetic patients: a prospective follow-up study.

    abstract::We have studied 46 patients, 30 men and 16 women, with type 2 (non-insulin-dependent) diabetes in a follow-up period of 6-52 months (mean 30 months). The patients were consecutively entered in the study from the out-patient diabetic clinic. None had urinary tract infections nor proteinuria at entry. Investigations wer...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329703400304

    authors: Friis T,Pedersen LR

    更新日期:1997-05-01 00:00:00

  • A review of troponin assay performance in Wales: can the same (method-dependent) decision limits be used in different sites?

    abstract::An audit of troponin measurement protocols in use in Wales showed significant variations in practice with no consensus on analytical methods, or in the selection of a decision limit for the diagnosis of myocardial damage. Peer review data on assay imprecision at concentrations approaching the analytical limit of detec...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1258/0004563054890006

    authors: Thomas MA,Singh GK,Williams EJ,McDowell IF,Tovey JA,Wayte AM,All Wales Clinical Biochemistry Audit Group.

    更新日期:2005-09-01 00:00:00

  • Continuous glucose monitoring and haemoglobin A(1c).

    abstract:BACKGROUND:Measurement of HbA(1c) is the standard test for assessment of glycaemic control in diabetic subjects. Using new glucose sensing technology we re-evaluated the significance of HbA(1c) in terms of the aspects of the blood profile it measures in patients with diabetes. METHODS:In a group of 27 patients with ty...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456302320314557

    authors: Sharp P,Rainbow S

    更新日期:2002-09-01 00:00:00

  • A possible analytical and clinical role of endogenous antibodies causing discrepant adrenocorticotropic hormone measurement in a case of ectopic Cushing's syndrome.

    abstract::Heterophilic antibodies are well described, but poorly appreciated interferents and is often not a recognized problem affecting most immunoassays. We report a patient presented with ectopic Cushing's syndrome (CS), but repeated plasma adrenocorticotropic hormone (ACTH) concentrations conducted by immunoassay were inap...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563214520751

    authors: Saiegh L,Odeh M,Chen-Konak L,Elias N,Sheikh-Ahmad M,Reut M,Slobodin G,Bejar J,Shechner C

    更新日期:2014-07-01 00:00:00

  • EXPRESS: Calculated globulin as a screening tool for hypogammaglobulinaemia or paraproteins in hospitalised patients.

    abstract:BACKGROUND:Calculated globulin fraction is derived from the liver function tests by subtracting albumin from the total protein. Since immunoglobulins comprise the largest component of the serum globulin concentration, increased or decreased calculated globulins and may identify patients with hypogammaglobulinaemia or h...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563221989737

    authors: Hoo T,Lim E,John M,D'Orsogna L,McLean-Tooke A

    更新日期:2021-01-11 00:00:00

  • Essential data derived from biological variation for establishment and use of lipid analyses.

    abstract::The analytical and biological components of variation of total cholesterol, high density lipoprotein (HDL) cholesterol, HDL3 cholesterol, HDL2 cholesterol and apolipoproteins A-I and B in serum were assessed in 12 apparently healthy individuals. All analytes showed marked individuality and therefore conventional popul...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600314

    authors: Ford RP

    更新日期:1989-05-01 00:00:00

  • Clinical impact of variability in HbA1c as assessed by simultaneously measuring fructosamine and use of error grid analysis.

    abstract:BACKGROUND:Haemoglobin A1c (HbA1c) is the only measure of glycaemic control used for many patients with diabetes, but it has limitations and might sometimes be misleading. HbA(1c) concentrations are influenced by conditions that alter red-cell life and there is evidence that biochemical variation in intracellular glyca...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2008.007259

    authors: Macdonald DR,Hanson AM,Holland MR,Singh BM

    更新日期:2008-07-01 00:00:00

  • Assessment of the Beckman System 1.

    abstract::The System 1 produced results for glucose and urea which were precise and accurate. It proved suitable as a general laboratory instrument as it samples 28 mul of specimen, is able to calibrate itself, produces results in three minutes, and has the capacity to analyse 56 samples an hour. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327701400179

    authors: Potezny N,Quelch J,Fuller B,Geary TD

    更新日期:1977-09-01 00:00:00

  • Predicting refeeding hypophosphataemia: insulin growth factor 1 (IGF-1) as a diagnostic biochemical marker for clinical practice.

    abstract:BACKGROUND:Refeeding syndrome (RS) is a potentially fatal condition that can occur following the re-introduction of nutrition after a period of starvation. Hypophosphataemia following the reintroduction of nutrition is often the only reliable biochemical marker of RS. Refeeding index (RI) generated from baseline insuli...

    journal_title:Annals of clinical biochemistry

    pub_type: 临床试验,杂志文章

    doi:10.1177/0004563214523739

    authors: Goyale A,Ashley SL,Taylor DR,Elnenaei MO,Alaghband-Zadeh J,Sherwood RA,le Roux CW,Vincent RP

    更新日期:2015-01-01 00:00:00

  • Elevated erythrocyte sedimentation rate and high-sensitivity C-reactive protein in osteoarthritis of the knee: relationship with clinical findings and radiographic severity.

    abstract:PURPOSE:We assessed erythrocyte sedimentation rate and high-sensitivity C-reactive protein concentration in knee osteoarthritis and non-knee osteoarthritis. In addition, we investigated potential relationship between the levels of erythrocyte sedimentation rate and high-sensitivity C-reactive protein with clinical find...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215610142

    authors: Hanada M,Takahashi M,Furuhashi H,Koyama H,Matsuyama Y

    更新日期:2016-09-01 00:00:00