Abstract:
OBJECTIVES:We aim to compare the diagnostic performance to assess thyroid nodules and reliability for recommending fine needle aspiration biopsy (FNAB) between American College of Radiology thyroid image reporting and data system (ACR TI-RADS) and American Thyroid Association (ATA) guidelines. METHODS:In total, this retrospective study included 1001 consecutive thyroid nodules in 918 patients from May 2016 to December 2017. US features of the thyroid nodules, including composition, echogenicity, shape, margins, echogenic foci, and size, were reviewed and were classified according to ACR TI-RADS and ATA guidelines, respectively. The diagnostic performance to assess thyroid nodules and reliability for recommending fine needle aspiration biopsy were compared between ACR TI-RADS and ATA guidelines. RESULTS:Of the 1001 thyroid nodules, 609 (60.8%) were benign and 392 (39.2%) were malignant. The sensitivity, specificity, PPV, NPV, and accuracy were 96.7%, 77.3%, 73.3%, 97.3%, and 84.9%, respectively, for ACR TI-RADS and 99.2%, 16.1%, 43.2%, 97.0%, and 48.7%, respectively, for ATA guidelines. AUC of ACR TI-RADS was significantly greater than ATA guidelines (0.935 (0.918, 0.949) vs 0.884 (0.862, 0.903), p < 0.001). Biopsy yield of malignancy, biopsy rate of malignancy, and unnecessary FNAB rate were 59.5%, 91.3%, and 40.5%, respectively, for ACR TI-RDS and 38.5%, 97.4%, and 61.5%, respectively, for ATA guidelines. CONCLUSIONS:ACR TI-RADS was more accurate than ATA guidelines for differentiating malignant thyroid nodules from benign nodules and more reliable than ATA guidelines for recommending thyroid nodules for FNAB. KEY POINTS:• Malignant risk of thyroid nodules can be stratified by ultrasound. • American College of Radiology guidelines were more accurate for differentiating malignant thyroid nodules from benign nodules. • American College of Radiology guidelines were more reliable for recommending thyroid nodules for biopsy.
journal_name
Eur Radioljournal_title
European radiologyauthors
Ruan JL,Yang HY,Liu RB,Liang M,Han P,Xu XL,Luo BMdoi
10.1007/s00330-018-5992-zsubject
Has Abstractpub_date
2019-09-01 00:00:00pages
4871-4878issue
9eissn
0938-7994issn
1432-1084pii
10.1007/s00330-018-5992-zjournal_volume
29pub_type
杂志文章abstract::We report the CT and pathological findings of an intra-abdominal desmoplastic small round-cell tumor in a young man. Computed tomography showed an extensive peritoneal and mesenteric disease with gross bulky masses, direct liver invasion, and lymph node involvement. This entity should be considered in the differential...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300051011
更新日期:2000-01-01 00:00:00
abstract:AIM:To evaluate the accuracy of a T2-weighted (T2w) - and a parallel transmit zoomed b = 2000 s/mm2 (b2000) - diffusion-weighted imaging sequence among three readers with different degrees of experience for prostate cancer (Pca) detection. METHODS:Ninety-three patients with suspected Pca were enrolled. For b2000 a two...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5004-8
更新日期:2018-02-01 00:00:00
abstract:OBJECTIVES:To develop and evaluate the performance of a deep learning-based system for automatic patellar height measurements using knee radiographs. METHODS:The deep learning-based algorithm was developed with a data set consisting of 1018 left knee radiographs for the prediction of patellar height parameters, specif...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06856-z
更新日期:2020-09-01 00:00:00
abstract::In the absence of reliable supplies of X-ray film, direct fluoroscopy is still extensively used in Albania, with chest radiology a particularly common application. This paper aims to quantify both patient skin dose and the risk-related quantity effective dose for direct fluoroscopy units based in seven different Alban...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300000462
更新日期:2001-01-01 00:00:00
abstract:OBJECTIVE:To assess the role of colour Doppler flow imaging (CDFI) in the diagnosis and management of lacrimal fossa lesions. METHODS:Institutional ethical committee approval was obtained. Fifty-one patients with 62 lacrimal fossa lesions were retrospectively included from 2003-2015. All patients underwent conventiona...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4438-8
更新日期:2017-02-01 00:00:00
abstract::Imaging is the standard method for the evaluation of emergency bile ducts and gallbladder diseases. Imaging may help to treat the patient also. In acute cholecystitis, association of clinical and sonographic data is accurate for the diagnosis, even when the patient is examined by a junior radiologist. Computed tomogra...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-002-1613-x
更新日期:2002-10-01 00:00:00
abstract:OBJECTIVES:To evaluate factors associated with increased fluoroscopy time or the need for complex techniques at IVC filter retrieval. METHODS:This is a single-institution retrospective cohort study of 187 consecutive patients who underwent IVC filter retrieval. An analysis was performed on associations of patient fact...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5766-7
更新日期:2019-04-01 00:00:00
abstract::The aim of this study was to describe type and rate of complications in a series of patients with liver tumors treated by the radiofrequency (RF) expandable system. A total of 166 patients, 114 with hepatocellular carcinoma (HCC; 92 small HCC, 22 large) and 52 with liver metastasis, were treated by the percutaneous RF...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-1990-9
更新日期:2004-01-01 00:00:00
abstract:OBJECTIVE:To qualitatively and quantitatively compare different late gadolinium enhancement (LGE) sequences acquired at 3T with a parallel RF transmission technique. METHODS:One hundred and sixty participants prospectively enrolled underwent a 3T cardiac MRI with 3 different LGE sequences: 3D Phase-Sensitive Inversion...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-4002-y
更新日期:2016-06-01 00:00:00
abstract:OBJECTIVES:To investigate the imaging findings and clinical time course of COVID-19 pneumonia. METHODS:A total of 113 baseline and follow-up CT scans from 24 January 2020 to 18 February 2020 were longitudinally collected from 29 confirmed COVID-19 patients in a single center. The changes in the clinical and laboratory...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07007-0
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVE:To investigate the application value of the ADC(difference) value in evaluating the pathological grade of uterine cervical cancer and to analyse the correlations among microvascular density (MVD), vascular endothelial growth factor (VEGF) expression and maximum ADC(difference) value. METHODS:Fifty-six patien...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2657-1
更新日期:2013-03-01 00:00:00
abstract:OBJECTIVES:To develop a radiomics model for predicting hematoma expansion in patients with intracerebral hemorrhage (ICH) and to compare its predictive performance with a conventional radiological feature-based model. METHODS:We retrospectively analyzed 251 consecutive patients with acute ICH. Two radiologists indepen...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06378-3
更新日期:2020-01-01 00:00:00
abstract::Peripheral nerve tumors are not frequent, but due to their association with a nerve they are somewhat special. They may be encountered incidentally during evaluation of a soft-tissue mass or when a nerve lesion is clinically suspected and the recognition of such a lesion and its differential diagnosis is key for succe...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-007-0645-7
更新日期:2007-11-01 00:00:00
abstract:OBJECTIVE:The objective was to evaluate the initial experience and safety of magnetic resonance imaging (MRI)-guided transcranial cryoablation in cystic metastatic brain tumours. MATERIAL AND METHODS:Seven cystic metastatic brain tumours in six patients were treated with cryoablation. The approval from the local ethic...
journal_title:European radiology
pub_type: 临床试验,杂志文章
doi:10.1007/s00330-009-1554-8
更新日期:2010-02-01 00:00:00
abstract::This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between ...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-008-1239-8
更新日期:2009-05-01 00:00:00
abstract:OBJECTIVE:To test a digital imaging X-ray device based on the direct capture of X-ray photons with pixel detectors, which are coupled with photon-counting readout electronics. METHODS:The chip consists of a matrix of 256 × 256 pixels with a pixel pitch of 55 μm. A monolithic image of 11.2 cm × 7 cm was obtained by the...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-011-2246-8
更新日期:2012-01-01 00:00:00
abstract::To assess both sensitivity and specificity of digital chest radiography alone and in conjunction with dual-exposure dual-energy chest radiography for the detection and classification of pulmonary nodules. One hundred patients with a total of 149 lung nodules (3-45 mm; median, 11 mm) confirmed by CT were included in th...
journal_title:European radiology
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1007/s00330-008-0945-6
更新日期:2008-09-01 00:00:00
abstract::The aim of this study was to assess the interobserver variations in diagnosis of pulmonary embolism (PE) with cine technique and to compare the diagnostic accuracy of pulmonary arteriograms to final-outcome diagnosis. One hundred and seventy patients with clinical suspicion of acute PE were examined with ECG, laborato...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050667
更新日期:1999-01-01 00:00:00
abstract:OBJECTIVES:To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) in identifying bone marrow edema (BME) around the hip joint in non-traumatic patients. METHODS:This prospective IRB-approved study was conducted between January 2019 and October 2019 and included 59 consecutive patients (18 males,...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06775-z
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to investigate the association of relaxation-compensated chemical exchange saturation transfer (CEST) MRI with overall survival (OS) and progression-free survival (PFS) in newly diagnosed high-grade glioma (HGG) patients. METHODS:Twenty-six patients with newly diagnosed high-gr...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06066-2
更新日期:2019-09-01 00:00:00
abstract:OBJECTIVE:To compare the diagnostic performance of full-field digital mammography (FFDM) with screen-film mammography (SFM) in a corporate screening programme including younger women. METHODS:Data were available on 14,946 screening episodes, 5010 FFDM and 9936 SFM. Formal analysis was by logistic regression, adjusting...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-1968-3
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVES:This study evaluated the predictive role of 1D, 2D and 3D quantitative, enhancement-based MRI regarding overall survival (OS) in patients with colorectal liver metastases (CLM) following intra-arterial therapies (IAT). METHODS:This retrospective analysis included 29 patients who underwent transarterial chem...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3595-5
更新日期:2015-07-01 00:00:00
abstract::The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance i...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1362-x
更新日期:2002-09-01 00:00:00
abstract::We retrospectively reviewed surgical biopsy findings of lesions diagnosed as radial scars (RS) at stereotactic core-needle biopsy (SCNB). RS was diagnosed in 52 of 1415 (3.7%) consecutive mammographically detected lesions that underwent 14-gauge automated SCNB. Subsequent surgical biopsy findings were available for 43...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0196-3
更新日期:2006-08-01 00:00:00
abstract::We assessed the effect of intra-coronary attenuation on diagnostic accuracy using 64-slice computed tomography coronary angiography (CT-CA). We enrolled 170 patients with suspected coronary artery disease who underwent conventional coronary angiography (CA) and 64-slice CT-CA (100 ml of Iomeprol 400 mg I/ml at 4 ml/s)...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-007-0773-0
更新日期:2008-03-01 00:00:00
abstract::The blood-ocular barrier (BOB) shares similar neuroepithelial origin, microanatomy and functions with the blood-brain barrier. There are many natural (e. g. diabetes, hypertension) or iatrogenic (chemotherapy, retinal photocoagulation) conditions which can cause a BOB breakdown, resulting in visual acuity impairment o...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050121
更新日期:1997-01-01 00:00:00
abstract::A novel ultrasonic imaging method, wideband harmonic imaging, for nonlinear imaging of microbubble contrast agents is evaluated. In wideband harmonic mode, two pulses of alternate phase are send out. The image is then processed from the sum of both pulses, resulting in an image of nonlinear scatterers such as microbub...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/pl00014075
更新日期:1999-01-01 00:00:00
abstract:PURPOSE:To evaluate the sensitivity of computer-aided detection(CAD) and dual-energy software('Lung PBV', 'Lung Vessels') for detecting peripheral pulmonary embolism(PE). MATERIALS AND METHODS:Between Jan-2007 and Jan-2008, 309 patients underwent dual-energy CT angiography(DECTA) for the evaluation of suspected PE. Am...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-1903-7
更新日期:2011-01-01 00:00:00
abstract::Our objective was to evaluate the hemolytic effect of stents and stent grafts in an in vitro flow model. The model consisted of silicone tubings. Pulsatile flow was delivered at 1170 ml/min. Diluted packed erythrocytes were used (hematocrit of 33%). The Palmaz, MegaLink stents or Passager, Hemobahn stent grafts were p...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1664-z
更新日期:2003-06-01 00:00:00
abstract:OBJECTIVES:To determine the correlation between CT measurements of emphysema or peripheral airways and airflow obstruction in chronic obstructive pulmonary disease (COPD). METHODS:PubMed, Embase and Web of Knowledge were searched from 1976 to 2011. Two reviewers independently screened 1,763 citations to identify artic...
journal_title:European radiology
pub_type: 杂志文章,meta分析,评审
doi:10.1007/s00330-012-2480-8
更新日期:2012-10-01 00:00:00