Abstract:
PURPOSE:Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). METHODS:We compared weighted volume CT dose index (CTDI(vol)) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. RESULTS:CTDI(Vol) of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority" of scanner E regarding image quality. CONCLUSIONS:The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level.
journal_name
Clin Neuroradioljournal_title
Clinical neuroradiologyauthors
Ozdoba C,Slotboom J,Schroth G,Ulzheimer S,Kottke R,Watzal H,Weisstanner Cdoi
10.1007/s00062-013-0263-5subject
Has Abstractpub_date
2014-03-01 00:00:00pages
23-8issue
1eissn
1869-1439issn
1869-1447journal_volume
24pub_type
杂志文章abstract:PURPOSE:Since the incidental discovery and systematic introduction of mechanical endovascular stroke treatment in 2015 there are few reports about the real-life situation in daily clinical practice. The aim of this study was to evaluate the mechanical thrombectomy data documented in the quality assurance database of th...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-020-00989-w
更新日期:2021-01-22 00:00:00
abstract:BACKGROUND AND PURPOSE:The GestSure system is an Food and Drugs Administration (FDA)-registered depth-sensing infrared device initially developed for touchless image navigation during open surgery. The goal of this study was to explore the feasibility of this technology with medical students, residents, fellows and sta...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-019-00829-6
更新日期:2019-11-06 00:00:00
abstract:BACKGROUND AND PURPOSE:A new curative embolization technique with Onyx for selected small- and medium-sized superficially located brain arteriovenous malformations (AVMs) was developed, which consists of obliteration of the nidus, including incremental occlusion of the draining veins. We report our first clinical resul...
journal_title:Clinical neuroradiology
pub_type: 临床试验,杂志文章
doi:10.1007/s00062-012-0149-y
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Acute major stroke with high-grade stenosis or occlusion of the extracranial internal carotid artery (ICA) and additional intracranial large artery occlusion is increasingly treated with a mechanical endovascular approach by extracranial stenting and intracranial thrombectomy due to poor response to systemic th...
journal_title:Clinical neuroradiology
pub_type: 临床试验,杂志文章
doi:10.1007/s00062-014-0318-2
更新日期:2015-12-01 00:00:00
abstract:PURPOSE:Internal jugular vein (IJV) narrowing superiorly is likely relatively frequent. IJV narrowing has been proposed as a potential pathophysiologic component for multiple sclerosis (MS). Our purpose was to investigate the prevalence of incidental superior IJV narrowing in patients imaged with neck computed tomograp...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-013-0232-z
更新日期:2014-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to compare vertebral failure loads, predicted from finite element (FE) analysis of patients with and without osteoporotic vertebral fractures (OVF) at virtually reduced dose levels, compared to standard-dose exposure from multidetector computed tomography (MDCT) imaging and evaluate wh...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-018-0722-0
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:Diagnosis of cortical vein thrombosis (CVT) on the basis of clot hyperintensity on diffusion-weighted imaging (DWI) has been reported as limited. Our aim was to evaluate different DWI findings of CVT either in isolated form or in combination with sinus thrombosis. METHODS:In this review-board-approved study, p...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-014-0301-y
更新日期:2015-09-01 00:00:00
abstract::The technology available for the endovascular treatment of intracranial aneurysms is rapidly evolving. Both current and future devices are described. This includes, among others, UNO for parent vessel occlusion, the Medina device for saccular filling, the Comaneci device for remodeling, pCONus for assisted coil occlus...
journal_title:Clinical neuroradiology
pub_type: 杂志文章,评审
doi:10.1007/s00062-015-0403-1
更新日期:2015-10-01 00:00:00
abstract::The aim of the study was to evaluate the B‑flow sonography (BFS) to image the basal cerebral arteries in newborn infants. For this purpose 34 newborns, who underwent standardized ultrasound of the brain including BFS, color Doppler (CDS) and power Doppler (PDS) techniques were retrospectively assessed. Delineation of ...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-017-0624-6
更新日期:2019-03-01 00:00:00
abstract:BACKGROUND:Distal embolization or movement of the thrombus to previously uninvolved vasculature are feared complications during stroke thrombectomy. We looked at associated factors in a consecutive series of patients who underwent thrombectomy with the same endovascular device. METHODS:We included all patients with ac...
journal_title:Clinical neuroradiology
pub_type: 杂志文章,评审
doi:10.1007/s00062-018-0679-z
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:Patients with transient global amnesia (TGA) present with a characteristic clinical syndrome although other differential diagnoses have to be considered. Diffusion-weighted imaging (DWI) represents a highly specific diagnostic tool in the context of TGA; however, standard clinical DWI often fails to detect the ...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-012-0140-7
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:Our aim was to identify imaging characteristics of pilocytic astrocytomas (PAs) in the cerebral ventricles to help radiologists distinguish PAs from other brain tumors preoperatively. METHODS:Twelve postsurgery patients with a pathological PA diagnosis were included. Among them, 10 had submitted to surgery bas...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-015-0370-6
更新日期:2016-09-01 00:00:00
abstract:PURPOSE:Evaluation of a new postprocessing method for postoperative control of cochlear implants (CI) based on a single flat detector computed tomography (FD-CT) run and volume rendering of 3D models of the inner ear. METHODS:The FD-CT datasets of CIs were selected and postprocessed to generate both standard multiplan...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-019-00832-x
更新日期:2020-12-01 00:00:00
abstract:PURPOSE:Brain arteriovenous malformations (bAVM) are the main cause of pediatric intracerebral hemorrhage (pICH). Embolization with Onyx (ev3, Irvine, CA, USA) in children with ruptured bAVM has been infrequently reported. The aim of this study was to assess the safety and efficacy profile of Onyx embolization as first...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-019-00861-6
更新日期:2019-12-04 00:00:00
abstract::Conventional magnetic resonance (MR) imaging of space-occupying lesions may answer most of the questions concerning the diagnosis and subsequent treatment strategies if patient age, clinical and paraclinical findings are considered as well. However, crucial and relevant differential diagnoses require additional MR met...
journal_title:Clinical neuroradiology
pub_type: 杂志文章,评审
doi:10.1007/s00062-011-0073-6
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:The aim of this study was to compare a recently established whole brain MR spectroscopic imaging (wbMRSI) technique using spin-echo planar spectroscopic imaging (EPSI) acquisition and the Metabolic Imaging and Data Analysis System (MIDAS) software package with single voxel spectroscopy (SVS) technique and LCMod...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-018-00757-x
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:Knowledge about the localization and outcome of iatrogenic dissection (ID) during endovascular treatment of acute ischemic stroke (AIS) is limited. We aimed to determine the frequency, clinical aspects and morphology of ID in endovascular AIS treatment and to identify predictors of this complication. METHODS:D...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-017-0639-z
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:Stroke is a rising cause of mortality in human immunodeficiency virus (HIV) and acquired immunodeficiency syndrome (AIDS) populations. The etiology of stroke remains at the core of the decision-making process to treat and prevent recurrent events. In this population HIV vasculopathy (HIV-V) and varicella zoster...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-011-0087-0
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:Visualization of the abducens nerve in its petroclival segment still remains challenging. We aimed to investigate the detectability of the petroclival segment of the abducens nerve and to evaluate the role of the size of the petroclival venous confluence (PVC) in the visibility of the nerve using contrast-enhan...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-015-0415-x
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:The optimal strategy for the treatment of M1 segment aneurysms has not yet been determined as both standard microneurosurgical and endovascular techniques can pose challenges. We sought to determine the efficacy of flow diverting stents to treat small, unruptured aneurysms of the M1 segment. METHODS:We retrosp...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-016-0553-9
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:Septo-optic dysplasia is a congenital disorder consisting of optic nerve hypoplasia and absent septum pellucidum. While associated anomalies have been described, olfactory sulcus and bulb-tract hypoplasia have been scantily reported and was the focus of this study. METHODS:The picture archival and communicatio...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-018-0687-z
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:Isolated posterior inferior cerebellar artery dissecting aneurysms are rare lesions. Their underlying pathology, presentation, and natural history are poorly understood. Their treatment is controversial, and few data are available regarding the best treatment. We conducted the first study comparing selective co...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-013-0247-5
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:Claustrophobic reactions in patients undergoing magnetic resonance imaging (MRI) have a significant impact on the workflow, patient acceptance and ultimately the costs involved in obtaining a diagnostic scan. The purpose of this study was to determine if the use of a wide, short bore MRI scanner could reduce th...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-011-0075-4
更新日期:2011-09-01 00:00:00
abstract:BACKGROUND:In the diagnosis of brain death (BD), computed tomography angiography (CTA) results in some cases show intracranial filling, leading to diagnostic confusion. Because cerebral circulatory arrest commences at the capillary level, we hypothesized that computed tomography perfusion (CTP) would be a more sensitiv...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-017-0631-7
更新日期:2019-03-01 00:00:00
abstract:OBJECTIVES:The overlapping symptoms of Parkinson's disease (PD) and progressive supranuclear palsy-Richardson's syndrome (PSP-RS) often make a correct clinical diagnosis difficult. The volume of subcortical brain structures derived from high-resolution T1-weighted magnetic resonance imaging (MRI) datasets is frequently...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-018-0727-8
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:The authors investigated the potential of a 32-channel (32ch) receiving head coil for functional magnetic resonance imaging (fMRI) compared to a standard eight-channel (8ch) coil using a motor task. MATERIAL AND METHODS:Brain activation was analyzed in 14 healthy right-handed subjects performing finger tapping...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-010-0029-2
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:Against the background of the increasing dilemma in the scientific community regarding protected versus unprotected carotid artery stent (CAS) placement and the disputed points in interpreting the results of scientific studies as well as the difficulty in conducting such randomized controlled studies, this arti...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-011-0057-6
更新日期:2011-06-01 00:00:00
abstract:PURPOSE:To review the fundamental principles of susceptibility-weighted imaging (SWI) and quantitative susceptibility mapping (QSM), and to discuss recent clinical developments. METHODS:SWI is a magnetic resonance imaging method that takes advantage of magnitude signal loss and phase information to reveal anatomic and...
journal_title:Clinical neuroradiology
pub_type: 杂志文章,评审
doi:10.1007/s00062-015-0432-9
更新日期:2015-10-01 00:00:00
abstract:OBJECTIVE:Tinnitus is defined as an imaginary subjective perception in the absence of an external sound. Convergent evidence proposes that tinnitus perception includes auditory, attentional and emotional components. The aim of this study was to investigate the thalamic, auditory and limbic interactions associated with ...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-015-0473-0
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. ME...
journal_title:Clinical neuroradiology
pub_type: 杂志文章
doi:10.1007/s00062-013-0279-x
更新日期:2015-03-01 00:00:00