Iatrogenic Vessel Dissection in Endovascular Treatment of Acute Ischemic Stroke.

Abstract:

PURPOSE:Knowledge about the localization and outcome of iatrogenic dissection (ID) during endovascular treatment of acute ischemic stroke (AIS) is limited. We aimed to determine the frequency, clinical aspects and morphology of ID in endovascular AIS treatment and to identify predictors of this complication. METHODS:Digital subtraction angiography (DSA) of ID carried out during endovascular treatment between January 2000 and March 2012 have been re-evaluated. The ID localization and morphology were analyzed and related to the interventional techniques. Baseline clinical and radiological findings, treatment modality and outcome were compared with patients without ID. RESULTS:Out of 866 patients 18 (2%) suffered an ID (44% female, median age 64 years). Localization was extracranial in 15 (83%, 14 internal carotid artery and 1 vertebral artery) and intracranial in 3 (17%; 1 vertebrobasilar dissection and 2 in the anterior circulation). Of the IDs 5 (28%) resulted in a high-degree, 3 (17%) in a moderate, 5 (28%) in a mild and 5 (28%) in no stenosis and 8 IDs were stented in the acute phase. At 3 months 7 (42%) patients had a favorable outcome (modified Rankin score mRS ≤ 2) and 6 (33%) patients had died. Patients with ID had a different stroke etiology (p = 0.041), were more likely to be smokers (44% versus 19%, p = 0.015) and were more likely to be treated with mechanical thrombectomy (100% versus 60%, p < 0.001). Although two ID patients had relevant complications, the outcome did not differ between the groups. CONCLUSION:The occurrence of ID is a rare complication of endovascular AIS treatment associated with smoking and mechanical thrombectomy.

journal_name

Clin Neuroradiol

journal_title

Clinical neuroradiology

authors

Goeggel Simonetti B,Hulliger J,Mathier E,Jung S,Fischer U,Sarikaya H,Slotboom J,Schroth G,Mordasini P,Gralla J,Arnold M

doi

10.1007/s00062-017-0639-z

subject

Has Abstract

pub_date

2019-03-01 00:00:00

pages

143-151

issue

1

eissn

1869-1439

issn

1869-1447

pii

10.1007/s00062-017-0639-z

journal_volume

29

pub_type

杂志文章
  • [Middle cerebral artery infarct after aneurysm coiling].

    abstract::The report concerns a 44-year-old female patient with incidental left middle cerebral artery aneurysm. After endovascular therapy by coiling, a hemiparesis was observed following extubation. Disturbance of speech and disorientation added later. An infarct of the lenticular nucleus was found. The angiography showed an ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-010-0007-8

    authors: Turowski B,Becker H

    更新日期:2010-06-01 00:00:00

  • Two in One: Endovascular Treatment of Acute Tandem Occlusions in the Anterior Circulation.

    abstract:PURPOSE:Acute major stroke with high-grade stenosis or occlusion of the extracranial internal carotid artery (ICA) and additional intracranial large artery occlusion is increasingly treated with a mechanical endovascular approach by extracranial stenting and intracranial thrombectomy due to poor response to systemic th...

    journal_title:Clinical neuroradiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00062-014-0318-2

    authors: Maurer CJ,Joachimski F,Berlis A

    更新日期:2015-12-01 00:00:00

  • Comparison of ESWAN, SWI-SPGR, and 2D T2*-weighted GRE sequence for depicting cerebral microbleeds.

    abstract:PURPOSE:We aimed to compare images obtained with an Enhanced 3D multi-echo GRE T2*-weighted angiography (ESWAN) sequence with those obtained with a susceptibility-weighted imaging-spoiled gradient-recalled echo (SWI-SPGR) sequence and a two-dimensional (2D) T2*-weighted gradient-recalled echo (GRE) sequence for the des...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-012-0185-7

    authors: Guo LF,Wang G,Zhu XY,Liu C,Cui L

    更新日期:2013-06-01 00:00:00

  • Optical Coherence Tomography as an Adjunct During Carotid Artery Stenting for Carotid Atherosclerotic Disease.

    abstract:PURPOSE:Carotid artery stenting (CAS) has been proven to decrease the risk of stroke in symptomatic patients with moderate/high-grade carotid stenosis; however, there is an increased periprocedural risk of stroke with CAS compared to carotid endarterectomy. The goal of this article is to report the utilization of endov...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00799-9

    authors: Pasarikovski CR,Ramjist J,da Costa L,Black SE,Cardinell J,Yang VX

    更新日期:2020-09-01 00:00:00

  • Evaluation of an Artificial Intelligence-Based 3D-Angiography for Visualization of Cerebral Vasculature.

    abstract:PURPOSE:The three-dimensional digital subtraction angiography (3D DSA) technique is the current standard and is based on both mask and fill runs to enable the subtraction technique. Artificial intelligence (AI)-based 3D angiography (3DA) was developed to reduce radiation dosage because only one contrast-enhanced run of...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00836-7

    authors: Lang S,Hoelter P,Schmidt M,Eisenhut F,Kaethner C,Kowarschik M,Lücking H,Doerfler A

    更新日期:2020-12-01 00:00:00

  • Neuroradiological viewpoint on the diagnostics of space-occupying brain lesions.

    abstract::Conventional magnetic resonance (MR) imaging of space-occupying lesions may answer most of the questions concerning the diagnosis and subsequent treatment strategies if patient age, clinical and paraclinical findings are considered as well. However, crucial and relevant differential diagnoses require additional MR met...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-011-0073-6

    authors: Faehndrich J,Weidauer S,Pilatus U,Oszvald A,Zanella FE,Hattingen E

    更新日期:2011-09-01 00:00:00

  • The Past, Present and Future of Endovascular Aneurysm Treatment.

    abstract::The technology available for the endovascular treatment of intracranial aneurysms is rapidly evolving. Both current and future devices are described. This includes, among others, UNO for parent vessel occlusion, the Medina device for saccular filling, the Comaneci device for remodeling, pCONus for assisted coil occlus...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-015-0403-1

    authors: Henkes H,Weber W

    更新日期:2015-10-01 00:00:00

  • SVM-Based Normal Pressure Hydrocephalus Detection.

    abstract:BACKGROUND AND PURPOSE:As magnetic resonance imaging (MRI) signs of normal pressure hydrocephalus (NPH) may precede clinical symptoms we sought to evaluate an algorithm that automatically detects this pattern. METHODS:A support vector machine (SVM) was trained in 30 NPH patients treated with ventriculoperitoneal shunt...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-020-00993-0

    authors: Rau A,Kim S,Yang S,Reisert M,Kellner E,Duman IE,Stieltjes B,Hohenhaus M,Beck J,Urbach H,Egger K

    更新日期:2021-01-26 00:00:00

  • Evaluation of a Touchless Angiography Suite Computer Controller for Neuroendovascular Procedures.

    abstract:BACKGROUND AND PURPOSE:The GestSure system is an Food and Drugs Administration (FDA)-registered depth-sensing infrared device initially developed for touchless image navigation during open surgery. The goal of this study was to explore the feasibility of this technology with medical students, residents, fellows and sta...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00829-6

    authors: Dmytriw AA,Phan K,Tremaine J,Strickland M,Radovanovic I,Krings T,Pereira VM

    更新日期:2019-11-06 00:00:00

  • Magnetic resonance imaging appearance of primary spinal extradural Ewing's sarcoma: case report and literature review.

    abstract:PURPOSE:Primary spinal extradural Ewing's sarcoma (PSEES) or primitive neuroectodermal tumor (PNET) is uncommon. The present study summarizes the magnetic resonance (MR) imaging appearance of PSEES. METHODS:Literature search from 1994 to 2012 with our representative case presentation. RESULTS:Twenty-one patients, 12 ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-013-0222-1

    authors: Tsutsumi S,Yasumoto Y,Manabe A,Ogino I,Arai H,Ito M

    更新日期:2013-06-01 00:00:00

  • First Line Onyx Embolization in Ruptured Pediatric Arteriovenous Malformations : Safety and Efficacy.

    abstract:PURPOSE:Brain arteriovenous malformations (bAVM) are the main cause of pediatric intracerebral hemorrhage (pICH). Embolization with Onyx (ev3, Irvine, CA, USA) in children with ruptured bAVM has been infrequently reported. The aim of this study was to assess the safety and efficacy profile of Onyx embolization as first...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00861-6

    authors: Alias Q,Boulouis G,Blauwblomme T,Benichi S,Beccaria K,Gariel F,Garzelli L,Meyer P,Kossorotoff M,Boddaert N,Brunelle F,Naggara O

    更新日期:2019-12-04 00:00:00

  • Potential impact of a 32-channel receiving head coil technology on the results of a functional MRI paradigm.

    abstract:PURPOSE:The authors investigated the potential of a 32-channel (32ch) receiving head coil for functional magnetic resonance imaging (fMRI) compared to a standard eight-channel (8ch) coil using a motor task. MATERIAL AND METHODS:Brain activation was analyzed in 14 healthy right-handed subjects performing finger tapping...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-010-0029-2

    authors: Albrecht J,Burke M,Haegler K,Schöpf V,Kleemann AM,Paolini M,Wiesmann M,Linn J

    更新日期:2010-12-01 00:00:00

  • Angiographic Patterns and Outcomes Achieved by Proximal Balloon Occlusion in Symptomatic Carotid Artery Stenosis Stenting.

    abstract:BACKGROUND AND PURPOSE:The best embolic protection strategy has not yet been established for carotid artery stenting (CAS). This article reports a new simplified approach using a balloon guide catheter inspired by stroke therapy, in patients harboring a symptomatic ICA atherosclerotic stenosis or web. In addition, the ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00770-8

    authors: Dargazanli C,Mahmoudi M,Cappucci M,Collemiche FL,Labreuche J,Habza O,Gascou G,Lefèvre PH,Eker O,Mourand I,Gaillard N,Charif M,Derraz I,Arquizan C,Costalat V

    更新日期:2020-06-01 00:00:00

  • Parametric color coding of digital subtraction angiography in the evaluation of carotid cavernous fistulas.

    abstract:PURPOSE:Angiographic assessment of carotid cavernous fistulas (CCFs) can be complex. Our purpose was to examine whether the use of parametric color coding in the postprocessing of DSA series is advantageous in the evaluation of CCFs. METHODS:We enrolled 16 patients with angiographically proven CCFs. Endovascular treat...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-012-0184-8

    authors: Gölitz P,Struffert T,Lücking H,Rösch J,Knossalla F,Ganslandt O,Deuerling-Zheng Y,Doerfler A

    更新日期:2013-06-01 00:00:00

  • Wide, short bore magnetic resonance at 1.5 t: reducing the failure rate in claustrophobic patients.

    abstract:PURPOSE:Claustrophobic reactions in patients undergoing magnetic resonance imaging (MRI) have a significant impact on the workflow, patient acceptance and ultimately the costs involved in obtaining a diagnostic scan. The purpose of this study was to determine if the use of a wide, short bore MRI scanner could reduce th...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-011-0075-4

    authors: Hunt CH,Wood CP,Lane JI,Bolster BD,Bernstein MA,Witte RJ

    更新日期:2011-09-01 00:00:00

  • Posterior Circulation Occlusions May Be Associated with Distal Emboli During Thrombectomy : Factors for Distal Embolization and a Review of the Literature.

    abstract:BACKGROUND:Distal embolization or movement of the thrombus to previously uninvolved vasculature are feared complications during stroke thrombectomy. We looked at associated factors in a consecutive series of patients who underwent thrombectomy with the same endovascular device. METHODS:We included all patients with ac...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-018-0679-z

    authors: Yeo LLL,Holmberg A,Mpotsaris A,Söderman M,Holmin S,Kuntze Söderqvist A,Ohlsson M,Bhogal P,Gontu V,Andersson T,Brouwer PA

    更新日期:2019-09-01 00:00:00

  • Isometric non-machine-based prevention training program: effects on the cross-sectional area of the paravertebral muscles on magnetic resonance imaging.

    abstract:PURPOSE:The purpose of this study was to determine potential effects of isometric non-machine-based training on the cross-sectional area (CSA) of the paravertebral muscles in volunteers who were participants in a prevention program. An increase in the CSA of back muscles after various machine-based exercises have been ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-011-0104-3

    authors: Lescher S,Bender B,Eifler R,Haas F,Gruber K,Felber S

    更新日期:2011-11-01 00:00:00

  • Diffusion-Weighted MR Imaging Findings of Cortical Vein Thrombosis at 3 T.

    abstract:PURPOSE:Diagnosis of cortical vein thrombosis (CVT) on the basis of clot hyperintensity on diffusion-weighted imaging (DWI) has been reported as limited. Our aim was to evaluate different DWI findings of CVT either in isolated form or in combination with sinus thrombosis. METHODS:In this review-board-approved study, p...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-014-0301-y

    authors: Yıldız ME,Ozcan UA,Turk A,Ulus OS,Erzen C,Dinçer A

    更新日期:2015-09-01 00:00:00

  • Stent Retriever Thrombectomy with Mindframe Capture LP in Isolated M2 Occlusions.

    abstract:BACKGROUND AND PURPOSE:Mechanical thrombectomy is an effective recanalization technique in acute ischemic stroke patients with large vessel occlusions; however, it is unclear to what extent stent retriever thrombectomy may be applicable to occlusions of smaller peripheral cerebral vessels. The outcome of patients with ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-0739-4

    authors: Dobrocky T,Bellwald S,Kurmann R,Piechowiak EI,Kaesmacher J,Mosimann PJ,Zibold F,Jung S,Arnold M,Fischer U,Gralla J,Mordasini P

    更新日期:2020-03-01 00:00:00

  • Regional Metabolite Concentrations in Aging Human Brain: Comparison of Short-TE Whole Brain MR Spectroscopic Imaging and Single Voxel Spectroscopy at 3T.

    abstract:PURPOSE:The aim of this study was to compare a recently established whole brain MR spectroscopic imaging (wbMRSI) technique using spin-echo planar spectroscopic imaging (EPSI) acquisition and the Metabolic Imaging and Data Analysis System (MIDAS) software package with single voxel spectroscopy (SVS) technique and LCMod...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-00757-x

    authors: Maghsudi H,Schmitz B,Maudsley AA,Sheriff S,Bronzlik P,Schütze M,Lanfermann H,Ding X

    更新日期:2020-06-01 00:00:00

  • MR angiography at 3 Tesla to assess proximal internal carotid artery stenoses: contrast-enhanced or 3D time-of-flight MR angiography?

    abstract:PURPOSE:The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. ME...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-013-0279-x

    authors: Weber J,Veith P,Jung B,Ihorst G,Moske-Eick O,Meckel S,Urbach H,Taschner CA

    更新日期:2015-03-01 00:00:00

  • Presurgical MR Imaging in Epilepsy.

    abstract::Primary goal of magnetic resonance imaging in epilepsy patients is to detect epileptogenic lesions with small lesions best detectable on a 3D FLAIR SPACE sequence with 1 mm(3) voxels. Morphometric analysis of 3D T1-weighted data sets helps to find subtle lesions and may reveal the true extent of a lesion. In further p...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-015-0387-x

    authors: Urbach H,Mast H,Egger K,Mader I

    更新日期:2015-10-01 00:00:00

  • Magnetic resonance imaging in transient global amnesia: lessons learned from 198 cases.

    abstract:PURPOSE:Patients with transient global amnesia (TGA) present with a characteristic clinical syndrome although other differential diagnoses have to be considered. Diffusion-weighted imaging (DWI) represents a highly specific diagnostic tool in the context of TGA; however, standard clinical DWI often fails to detect the ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-012-0140-7

    authors: Scheel M,Malkowsky C,Klingebiel R,Schreiber SJ,Bohner G

    更新日期:2012-12-01 00:00:00

  • MDCT-based Finite Element Analysis of Vertebral Fracture Risk: What Dose is Needed?

    abstract:PURPOSE:The aim of this study was to compare vertebral failure loads, predicted from finite element (FE) analysis of patients with and without osteoporotic vertebral fractures (OVF) at virtually reduced dose levels, compared to standard-dose exposure from multidetector computed tomography (MDCT) imaging and evaluate wh...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-0722-0

    authors: Anitha D,Mei K,Dieckmeyer M,Kopp FK,Sollmann N,Zimmer C,Kirschke JS,Noel PB,Baum T,Subburaj K

    更新日期:2019-12-01 00:00:00

  • Subtle Imaging Findings Aid the Diagnosis of Adolescent Hereditary Spastic Paraplegia and Ataxia.

    abstract:PURPOSE:Hereditary spastic paraplegia (HSP) and hereditary spastic ataxia (HSA) are a heterogeneous group of genetic disorders characterized by progressive lower limb spasticity resulting from pyramidal tract dysfunction. By identifying critical imaging findings within the clinical context of spasticity, radiologists a...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-0665-5

    authors: Wagner F,Titelbaum DS,Engisch R,Coskun EK,Waugh JL

    更新日期:2019-06-01 00:00:00

  • Advanced MR Imaging in Neuro-oncology.

    abstract::The value of magnetic resonance (MR) imaging for the clinical management of brain tumour patients has greatly increased in recent years through the introduction of functional MR sequences. Previously, MR imaging for brain tumours relied for the most part on contrast-enhanced T1-weighted MR sequences but today with the...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-015-0439-2

    authors: Radbruch A,Bendszus M

    更新日期:2015-10-01 00:00:00

  • B-Flow Sonography for Evaluation of Basal Cerebral Arteries in Newborns.

    abstract::The aim of the study was to evaluate the B‑flow sonography (BFS) to image the basal cerebral arteries in newborn infants. For this purpose 34 newborns, who underwent standardized ultrasound of the brain including BFS, color Doppler (CDS) and power Doppler (PDS) techniques were retrospectively assessed. Delineation of ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0624-6

    authors: Groth M,Ernst M,Deindl P,Herrmann J

    更新日期:2019-03-01 00:00:00

  • Imaging Features of Pilocytic Astrocytoma in Cerebral Ventricles.

    abstract:PURPOSE:Our aim was to identify imaging characteristics of pilocytic astrocytomas (PAs) in the cerebral ventricles to help radiologists distinguish PAs from other brain tumors preoperatively. METHODS:Twelve postsurgery patients with a pathological PA diagnosis were included. Among them, 10 had submitted to surgery bas...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-015-0370-6

    authors: Xia J,Yin B,Liu L,Lu Y,Geng D,Tian W

    更新日期:2016-09-01 00:00:00

  • Orbital masses: the usefulness of diffusion-weighted imaging in lesion categorization.

    abstract:INTRODUCTION:Diffusion-weighted imaging (DWI) produces contrast among different kinds of tissues according to their diffusibility characteristics. The purpose of our study was to evaluate the role of DWI including measurement of apparent diffusion coefficient (ADC) values in recognizing benignancy or malignancy of orbi...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-013-0234-x

    authors: Fatima Z,Ichikawa T,Ishigame K,Motosugi U,Waqar AB,Hori M,Iijima H,Araki T

    更新日期:2014-06-01 00:00:00

  • Management of Unruptured Saccular Aneurysms of the M1 Segment with Flow Diversion : A Single Centre Experience.

    abstract:PURPOSE:The optimal strategy for the treatment of M1 segment aneurysms has not yet been determined as both standard microneurosurgical and endovascular techniques can pose challenges. We sought to determine the efficacy of flow diverting stents to treat small, unruptured aneurysms of the M1 segment. METHODS:We retrosp...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-016-0553-9

    authors: Bhogal P,Martinez R,Gansladt O,Bäzner H,Henkes H,Aguilar M

    更新日期:2018-06-01 00:00:00