Evaluation of a Touchless Angiography Suite Computer Controller for Neuroendovascular Procedures.

Abstract:

BACKGROUND AND PURPOSE:The GestSure system is an Food and Drugs Administration (FDA)-registered depth-sensing infrared device initially developed for touchless image navigation during open surgery. The goal of this study was to explore the feasibility of this technology with medical students, residents, fellows and staff neurointerventionalists, using cases of intracranial aneurysm coiling. MATERIAL AND METHODS:This was a prospective cohort study of operative performance using standard keyboard and mouse against a gestural interface. A total of four medical students, six residents, six fellows and five staff neurointerventionalists were involved in the training and subsequent testing. Training involved description and demonstration of a set of gestures optimized for 3D software functions. Cases were selected from the set of patients who underwent endovascular aneurysm coiling at the Toronto Western Hospital. RESULTS AND CONCLUSION:For the overall group 15/21 (71.4%) individuals learned the left anterior oblique 30 degrees (LAO30) task within 20 cases, 17/21 (80.9%) learned the aneurysm neck task within 20 cases, 16/21 (76.2%) learned the parent vessel task and 14/21 (66%) learned the neck and parent vessel (anatomical) tasks. Staff were more consistent (i.e. smallest standard deviation) amongst the groups compared to medical students and residents; however, it was noted that a significant learning effect was observed in participants across every level of medical and angiographic expertise. Touchless angiography suite control with a gestural interface is feasible for the manipulation of angiographic images for neuroendovascular procedures. Learning to use the system was rapid across any level of medical training but greatest for staff neurointerventionalists.

journal_name

Clin Neuroradiol

journal_title

Clinical neuroradiology

authors

Dmytriw AA,Phan K,Tremaine J,Strickland M,Radovanovic I,Krings T,Pereira VM

doi

10.1007/s00062-019-00829-6

subject

Has Abstract

pub_date

2019-11-06 00:00:00

eissn

1869-1439

issn

1869-1447

pii

10.1007/s00062-019-00829-6

pub_type

杂志文章
  • B-Flow Sonography for Evaluation of Basal Cerebral Arteries in Newborns.

    abstract::The aim of the study was to evaluate the B‑flow sonography (BFS) to image the basal cerebral arteries in newborn infants. For this purpose 34 newborns, who underwent standardized ultrasound of the brain including BFS, color Doppler (CDS) and power Doppler (PDS) techniques were retrospectively assessed. Delineation of ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0624-6

    authors: Groth M,Ernst M,Deindl P,Herrmann J

    更新日期:2019-03-01 00:00:00

  • Merged Volume Rendered Flat-panel Computed Tomography for Postoperative Cochlear Implant Assessment.

    abstract:PURPOSE:Evaluation of a new postprocessing method for postoperative control of cochlear implants (CI) based on a single flat detector computed tomography (FD-CT) run and volume rendering of 3D models of the inner ear. METHODS:The FD-CT datasets of CIs were selected and postprocessed to generate both standard multiplan...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00832-x

    authors: Eisenhut F,Lang S,Taha L,Doerfler A,Iro H,Hornung J

    更新日期:2020-12-01 00:00:00

  • Magnetic resonance imaging in transient global amnesia: lessons learned from 198 cases.

    abstract:PURPOSE:Patients with transient global amnesia (TGA) present with a characteristic clinical syndrome although other differential diagnoses have to be considered. Diffusion-weighted imaging (DWI) represents a highly specific diagnostic tool in the context of TGA; however, standard clinical DWI often fails to detect the ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-012-0140-7

    authors: Scheel M,Malkowsky C,Klingebiel R,Schreiber SJ,Bohner G

    更新日期:2012-12-01 00:00:00

  • MR angiography at 3 Tesla to assess proximal internal carotid artery stenoses: contrast-enhanced or 3D time-of-flight MR angiography?

    abstract:PURPOSE:The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. ME...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-013-0279-x

    authors: Weber J,Veith P,Jung B,Ihorst G,Moske-Eick O,Meckel S,Urbach H,Taschner CA

    更新日期:2015-03-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography in stroke diagnostics: additional information compared with time-of-flight magnetic resonance angiography?

    abstract:PURPOSE:The aim of this study was a comparison of the diagnostic value of time-of-flight magnetic resonance angiography (TOF-MRA) and contrast-enhanced (CE) MRA in the setting of acute stroke MRI. The hypothesis was that CE-MRA has at least the same diagnostic value as the commonly used TOF-MRA. MATERIALS AND METHODS:...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-010-0039-0

    authors: Alfke K,Jensen U,Pool C,Rohr A,Brüning R,Weber J,Bartsch T,Stingele R,Jansen O

    更新日期:2011-04-01 00:00:00

  • Visualization of the Abducens Nerve in its Petroclival Segment Using Contrast-Enhanced FIESTA MRI: The Size of the Petroclival Venous Confluence Affects Detectability.

    abstract:PURPOSE:Visualization of the abducens nerve in its petroclival segment still remains challenging. We aimed to investigate the detectability of the petroclival segment of the abducens nerve and to evaluate the role of the size of the petroclival venous confluence (PVC) in the visibility of the nerve using contrast-enhan...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-015-0415-x

    authors: Özgür A,Esen K,Kara E,Temel GO

    更新日期:2017-03-01 00:00:00

  • Advanced MR Imaging in Neuro-oncology.

    abstract::The value of magnetic resonance (MR) imaging for the clinical management of brain tumour patients has greatly increased in recent years through the introduction of functional MR sequences. Previously, MR imaging for brain tumours relied for the most part on contrast-enhanced T1-weighted MR sequences but today with the...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-015-0439-2

    authors: Radbruch A,Bendszus M

    更新日期:2015-10-01 00:00:00

  • Presurgical MR Imaging in Epilepsy.

    abstract::Primary goal of magnetic resonance imaging in epilepsy patients is to detect epileptogenic lesions with small lesions best detectable on a 3D FLAIR SPACE sequence with 1 mm(3) voxels. Morphometric analysis of 3D T1-weighted data sets helps to find subtle lesions and may reveal the true extent of a lesion. In further p...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-015-0387-x

    authors: Urbach H,Mast H,Egger K,Mader I

    更新日期:2015-10-01 00:00:00

  • Clinical Significance of Circumferential Aneurysmal Wall Enhancement in Symptomatic Patients with Unruptured Intracranial Aneurysms: a High-resolution MRI Study.

    abstract:BACKGROUND AND PURPOSE:The estimates on the risk of rupture of intracranial aneurysms remain a controversial topic. Circumferential aneurysmal wall enhancement (CAWE) on vessel wall magnetic resonance imaging (MRI) has been described in unstable aneurysms. Sentinel headaches and third nerve palsy are possible symptoms ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0598-4

    authors: Fu Q,Guan S,Liu C,Wang K,Cheng J

    更新日期:2018-12-01 00:00:00

  • Regional Metabolite Concentrations in Aging Human Brain: Comparison of Short-TE Whole Brain MR Spectroscopic Imaging and Single Voxel Spectroscopy at 3T.

    abstract:PURPOSE:The aim of this study was to compare a recently established whole brain MR spectroscopic imaging (wbMRSI) technique using spin-echo planar spectroscopic imaging (EPSI) acquisition and the Metabolic Imaging and Data Analysis System (MIDAS) software package with single voxel spectroscopy (SVS) technique and LCMod...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-00757-x

    authors: Maghsudi H,Schmitz B,Maudsley AA,Sheriff S,Bronzlik P,Schütze M,Lanfermann H,Ding X

    更新日期:2020-06-01 00:00:00

  • Posterior Circulation Occlusions May Be Associated with Distal Emboli During Thrombectomy : Factors for Distal Embolization and a Review of the Literature.

    abstract:BACKGROUND:Distal embolization or movement of the thrombus to previously uninvolved vasculature are feared complications during stroke thrombectomy. We looked at associated factors in a consecutive series of patients who underwent thrombectomy with the same endovascular device. METHODS:We included all patients with ac...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-018-0679-z

    authors: Yeo LLL,Holmberg A,Mpotsaris A,Söderman M,Holmin S,Kuntze Söderqvist A,Ohlsson M,Bhogal P,Gontu V,Andersson T,Brouwer PA

    更新日期:2019-09-01 00:00:00

  • Computed Tomography Perfusion is a Useful Adjunct to Computed Tomography Angiography in the Diagnosis of Brain Death.

    abstract:BACKGROUND:In the diagnosis of brain death (BD), computed tomography angiography (CTA) results in some cases show intracranial filling, leading to diagnostic confusion. Because cerebral circulatory arrest commences at the capillary level, we hypothesized that computed tomography perfusion (CTP) would be a more sensitiv...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0631-7

    authors: Sawicki M,Sołek-Pastuszka J,Chamier-Ciemińska K,Walecka A,Walecki J,Bohatyrewicz R

    更新日期:2019-03-01 00:00:00

  • Isometric non-machine-based prevention training program: effects on the cross-sectional area of the paravertebral muscles on magnetic resonance imaging.

    abstract:PURPOSE:The purpose of this study was to determine potential effects of isometric non-machine-based training on the cross-sectional area (CSA) of the paravertebral muscles in volunteers who were participants in a prevention program. An increase in the CSA of back muscles after various machine-based exercises have been ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-011-0104-3

    authors: Lescher S,Bender B,Eifler R,Haas F,Gruber K,Felber S

    更新日期:2011-11-01 00:00:00

  • Parametric color coding of digital subtraction angiography in the evaluation of carotid cavernous fistulas.

    abstract:PURPOSE:Angiographic assessment of carotid cavernous fistulas (CCFs) can be complex. Our purpose was to examine whether the use of parametric color coding in the postprocessing of DSA series is advantageous in the evaluation of CCFs. METHODS:We enrolled 16 patients with angiographically proven CCFs. Endovascular treat...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-012-0184-8

    authors: Gölitz P,Struffert T,Lücking H,Rösch J,Knossalla F,Ganslandt O,Deuerling-Zheng Y,Doerfler A

    更新日期:2013-06-01 00:00:00

  • Imaging Features of Pilocytic Astrocytoma in Cerebral Ventricles.

    abstract:PURPOSE:Our aim was to identify imaging characteristics of pilocytic astrocytomas (PAs) in the cerebral ventricles to help radiologists distinguish PAs from other brain tumors preoperatively. METHODS:Twelve postsurgery patients with a pathological PA diagnosis were included. Among them, 10 had submitted to surgery bas...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-015-0370-6

    authors: Xia J,Yin B,Liu L,Lu Y,Geng D,Tian W

    更新日期:2016-09-01 00:00:00

  • Improved Automatic Morphology-Based Classification of Parkinson's Disease and Progressive Supranuclear Palsy.

    abstract:OBJECTIVES:The overlapping symptoms of Parkinson's disease (PD) and progressive supranuclear palsy-Richardson's syndrome (PSP-RS) often make a correct clinical diagnosis difficult. The volume of subcortical brain structures derived from high-resolution T1-weighted magnetic resonance imaging (MRI) datasets is frequently...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-0727-8

    authors: Talai AS,Ismail Z,Sedlacik J,Boelmans K,Forkert ND

    更新日期:2019-12-01 00:00:00

  • [Middle cerebral artery infarct after aneurysm coiling].

    abstract::The report concerns a 44-year-old female patient with incidental left middle cerebral artery aneurysm. After endovascular therapy by coiling, a hemiparesis was observed following extubation. Disturbance of speech and disorientation added later. An infarct of the lenticular nucleus was found. The angiography showed an ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-010-0007-8

    authors: Turowski B,Becker H

    更新日期:2010-06-01 00:00:00

  • Septo-optic Dysplasia : Assessment of Associated Findings with Special Attention to the Olfactory Sulci and Tracts.

    abstract:PURPOSE:Septo-optic dysplasia is a congenital disorder consisting of optic nerve hypoplasia and absent septum pellucidum. While associated anomalies have been described, olfactory sulcus and bulb-tract hypoplasia have been scantily reported and was the focus of this study. METHODS:The picture archival and communicatio...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-0687-z

    authors: Benson JC,Nascene D,Truwit C,McKinney AM

    更新日期:2019-09-01 00:00:00

  • Review of Temporal Bone Microanatomy : Aqueducts, Canals, Clefts and Nerves.

    abstract::Temporal bone microanatomy is a common source of consternation for radiologists. Serpentine foramina, branching cranial nerves, and bony canals containing often clinically relevant but often miniscule arterial branches may all cause confusion, even among radiologists familiar with temporal bone imaging. In some cases,...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-019-00864-3

    authors: Benson JC,Eckel L,Guerin J,Silvera VM,Diehn F,Passe T,Carlson ML,Lane JI

    更新日期:2020-06-01 00:00:00

  • The Past, Present and Future of Endovascular Aneurysm Treatment.

    abstract::The technology available for the endovascular treatment of intracranial aneurysms is rapidly evolving. Both current and future devices are described. This includes, among others, UNO for parent vessel occlusion, the Medina device for saccular filling, the Comaneci device for remodeling, pCONus for assisted coil occlus...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-015-0403-1

    authors: Henkes H,Weber W

    更新日期:2015-10-01 00:00:00

  • Dose reduction in standard head CT: first results from a new scanner using iterative reconstruction and a new detector type in comparison with two previous generations of multi-slice CT.

    abstract:PURPOSE:Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new dev...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-013-0263-5

    authors: Ozdoba C,Slotboom J,Schroth G,Ulzheimer S,Kottke R,Watzal H,Weisstanner C

    更新日期:2014-03-01 00:00:00

  • Magnetic Resonance Imaging in 14 Patients with Congenital Oculomotor Nerve Palsy.

    abstract:PURPOSE:To elucidate the imaging findings of congenital oculomotor nerve palsy by evaluating the oculomotor nerve and extraocular muscles on magnetic resonance (MR) imaging in a relatively large series of 14 patients with congenital oculomotor nerve palsy. METHODS:Ophthalmologic examination of 14 consecutive patients ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00781-5

    authors: Yang HK,Kim JH,Hwang JM

    更新日期:2020-06-01 00:00:00

  • Acute Endovascular Stroke Treatment in Germany in 2019 : Results from a Nationwide Database.

    abstract:PURPOSE:Since the incidental discovery and systematic introduction of mechanical endovascular stroke treatment in 2015 there are few reports about the real-life situation in daily clinical practice. The aim of this study was to evaluate the mechanical thrombectomy data documented in the quality assurance database of th...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-020-00989-w

    authors: Rohde S,Weber W,Berlis A,Urbach H,Reimer P,Schramm P,German Society of interventional Radiology and minimal invasive Therapy.,German Society of Interventional Radiology and Minimal Invasive Therapy (DeGIR) and the German Society of Neurora

    更新日期:2021-01-22 00:00:00

  • Carotid angioplasty and stenting without protection devices: safety and efficacy concerns--single center experience.

    abstract:PURPOSE:Against the background of the increasing dilemma in the scientific community regarding protected versus unprotected carotid artery stent (CAS) placement and the disputed points in interpreting the results of scientific studies as well as the difficulty in conducting such randomized controlled studies, this arti...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-011-0057-6

    authors: Mansour OY,Weber J,Niesen W,Schumacher M,Berlis A

    更新日期:2011-06-01 00:00:00

  • Correlation of diffusion MRI findings with lesion progression in patients with traumatic intracerebral hemorrhage : diffusion MRI in traumatic intracerebral hemorrhages with progression.

    abstract:PURPOSE:The aim of this study is to evaluate the association between lesion progression and the ischemic or edematous area that can develop around the hemorrhage in intraparenchymal hemorrhagic lesions originating after head trauma. METHODS:Thirty patients with intracerebral hemorrhage due to head trauma of a mild or ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-013-0251-9

    authors: Erol FS,Donmez O,Akgun B,Yildirim H,Kaplan M

    更新日期:2014-12-01 00:00:00

  • Comparison of Superior and Inferior Division Occlusions Treated with Endovascular Thrombectomy.

    abstract:BACKGROUND AND PURPOSE:Several studies have shown that thrombectomy is safe and effective in occlusions of the M2 segment of the middle cerebral artery. This retrospective study compared superior and inferior division occlusions regarding radiological and clinical outcomes. METHODS:Between 2009 and 2017, patients trea...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00767-3

    authors: Seker F,Pfaff J,Neuberger U,Schieber S,Nagel S,Ringleb PA,Bendszus M,Möhlenbruch MA

    更新日期:2020-06-01 00:00:00

  • Complication Risk Factors in Anterior Choroidal Artery Aneurysm Treatment.

    abstract:OBJECT:The anterior choroidal artery (AChoA) is a rare location for intracranial aneurysms. The treatment of these aneurysms may be challenging due to the risk of occlusion of such a small and eloquent artery as the AChoA. We aimed to evaluate the risk factors for complications in AChoA aneurysm treatment. METHODS:We ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0575-y

    authors: André A,Boch AL,Di Maria F,Nouet A,Sourour N,Clémenceau S,Gabrieli J,Degos V,Zeghal C,Chiras J,Cornu P,Clarençon F

    更新日期:2018-09-01 00:00:00

  • SVM-Based Normal Pressure Hydrocephalus Detection.

    abstract:BACKGROUND AND PURPOSE:As magnetic resonance imaging (MRI) signs of normal pressure hydrocephalus (NPH) may precede clinical symptoms we sought to evaluate an algorithm that automatically detects this pattern. METHODS:A support vector machine (SVM) was trained in 30 NPH patients treated with ventriculoperitoneal shunt...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-020-00993-0

    authors: Rau A,Kim S,Yang S,Reisert M,Kellner E,Duman IE,Stieltjes B,Hohenhaus M,Beck J,Urbach H,Egger K

    更新日期:2021-01-26 00:00:00

  • Long-term Angiographic Results of the Low-profile Acandis Acclino Stent for Treatment of Intracranial Aneurysms : A Multicenter Study.

    abstract:PURPOSE:The low-profile Acandis Acclino is a self-expandable nitinol microstent for stent-assisted coiling of intracranial aneurysms. This article reports long-term clinical and angiographic outcome in a multicenter setting. METHODS:In this study 98 consecutive patients (mean age 55.4 ± 13.5 years) were treated with t...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00847-4

    authors: Goertz L,Smyk MA,Mpotsaris A,Borggrefe J,Dorn F,Liebig T,Schlamann M,Laukamp K,Krischek B,Turowski B,Kabbasch C

    更新日期:2020-12-01 00:00:00

  • Limbic-Auditory Interactions of Tinnitus: An Evaluation Using Diffusion Tensor Imaging.

    abstract:OBJECTIVE:Tinnitus is defined as an imaginary subjective perception in the absence of an external sound. Convergent evidence proposes that tinnitus perception includes auditory, attentional and emotional components. The aim of this study was to investigate the thalamic, auditory and limbic interactions associated with ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-015-0473-0

    authors: Gunbey HP,Gunbey E,Aslan K,Bulut T,Unal A,Incesu L

    更新日期:2017-06-01 00:00:00