Comparison of single and tandem ureteral stenting for malignant ureteral obstruction: a prospective study of 104 patients.

Abstract:

OBJECTIVES:The aim of this study was to compare single and tandem ureteral stenting in the management of malignant ureteral obstruction (MUO). METHODS:Our hospital's institutional review board approved this prospective study. Between November 2014 and June 2017, single ureteral stenting was performed in 56 patients (94 renal units) and tandem ureteral stenting in 48 patients (63 renal units) for MUO. A comparative analysis of the technical success rate, patient survival, stent patency, and complications was performed. RESULTS:Similar demographic data were observed in patients receiving either single or tandem ureteral stenting. The technical success rate was 93.6% (88/94) for single ureteral stenting and 95.2% (60/63) for tandem ureteral stenting. There was no difference in overall survival between patients receiving single or tandem ureteral stenting (p = 0.41), but the duration of stent patency in tandem ureteral stenting was significantly longer (p = 0.022). The mean patency time was 176.7 ± 21.3 days for single ureteral stenting, and 214.7 ± 21.0 days for tandem ureteral stenting. The complications of ureteral stenting were urinary tract infection (n = 18), lower urinary tract symptoms (n = 5), haematuria (n = 3), and stent migration (n = 1). CONCLUSIONS:Tandem ureteral stenting is a safe and feasible treatment for MUO, and had better efficacy compared to single ureteral stenting. KEY POINTS:• Ureteral stenting is an established treatment for the management of malignant ureteral obstruction (MUO) • Prospective single-centre study showed that tandem ureteral stenting is a safe and feasible treatment for MUO • Tandem ureteral stenting provides longer stent patency compared to single ureteral stenting in patient with MUO.

journal_name

Eur Radiol

journal_title

European radiology

authors

Liu KL,Lee BC,Ye JD,Chang YH,Chang CC,Huang KH,Lee YJ,Chang YC

doi

10.1007/s00330-018-5560-6

subject

Has Abstract

pub_date

2019-02-01 00:00:00

pages

628-635

issue

2

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-018-5560-6

journal_volume

29

pub_type

杂志文章
  • Post-mortem computed tomography compared to forensic autopsy findings: a French experience.

    abstract:OBJECTIVES:The principal aim of our study was to establish concordance between post-mortem CT (PMCT) and forensic standard autopsy (SA) in detecting lesions according to different anatomical regions. A secondary aim was to determine the efficacy of PMCT in showing lethal lesions. METHODS:PMCTs were compared with autop...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2779-0

    authors: Le Blanc-Louvry I,Thureau S,Duval C,Papin-Lefebvre F,Thiebot J,Dacher JN,Gricourt C,Touré E,Proust B

    更新日期:2013-07-01 00:00:00

  • Small peripheral lung carcinomas with five-year post-surgical follow-up: assessment by semi-automated volumetric measurement of tumour size, CT value and growth rate on TSCT.

    abstract:OBJECTIVES:To retrospectively assess the utility of semi-automated measurements by stratification of CT values of tumour size, CT value and doubling time (DT) using thin-section computed tomography (CT) images. The post-surgical outcomes of favourable and problematic tumours (more advanced p stage than IA, post-surgica...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-011-2241-0

    authors: Sone S,Hanaoka T,Ogata H,Takayama F,Watanabe T,Haniuda M,Kaneko K,Kondo R,Yoshida K,Honda T

    更新日期:2012-01-01 00:00:00

  • Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT.

    abstract:OBJECTIVES:To evaluate the effect of hybrid iterative reconstruction on qualitative and quantitative parameters at 256-slice cardiac CT. METHODS:Prospective cardiac CT images from 20 patients were analysed. Paired image sets were created using 3 reconstructions, i.e. filtered back projection (FBP) and moderate- and hi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2361-6

    authors: Utsunomiya D,Weigold WG,Weissman G,Taylor AJ

    更新日期:2012-06-01 00:00:00

  • Variability of average SUV from several hottest voxels is lower than that of SUVmax and SUVpeak.

    abstract:OBJECTIVES:To assess variability of the average standard uptake value (SUV) computed by varying the number of hottest voxels within an (18)F-fluorodeoxyglucose ((18)F-FDG)-positive lesion. This SUV metric was compared with the maximal SUV (SUV(max): the hottest voxel) and peak SUV (SUV(peak): SUV(max) and its 26 neighb...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3222-x

    authors: Laffon E,Lamare F,de Clermont H,Burger IA,Marthan R

    更新日期:2014-08-01 00:00:00

  • Wideband harmonic imaging: a novel contrast ultrasound imaging technique.

    abstract::A novel ultrasonic imaging method, wideband harmonic imaging, for nonlinear imaging of microbubble contrast agents is evaluated. In wideband harmonic mode, two pulses of alternate phase are send out. The image is then processed from the sum of both pulses, resulting in an image of nonlinear scatterers such as microbub...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/pl00014075

    authors: Bauer A,Hauff P,Lazenby J,von Behren P,Zomack M,Reinhardt M,Schlief R

    更新日期:1999-01-01 00:00:00

  • Differences in perfusion parameters between upper and lower lumbar vertebral segments with dynamic contrast-enhanced MRI (DCE MRI).

    abstract::To investigate the influence of age, sex and spinal level on perfusion parameters of normal lumbar bone marrow with dynamic contrast-enhanced MRI (DCE MRI). Sixty-seven subjects referred for evaluation of low back pain or sciatica underwent DCE MRI of the lumbar spine. After subtraction of dynamic images, a region of ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0943-8

    authors: Savvopoulou V,Maris TG,Vlahos L,Moulopoulos LA

    更新日期:2008-09-01 00:00:00

  • Re-exposure to low osmolar iodinated contrast media in patients with prior moderate-to-severe hypersensitivity reactions: A multicentre retrospective cohort study.

    abstract:OBJECTIVES:To evaluate the outcomes of re-exposure to low-osmolar iodinated contrast medium (LOCM) in patients with a history of moderate-to-severe hypersensitivity reaction (HSR). METHODS:We retrospectively evaluated a cohort comprising all subjects satisfying the following conditions at 11 centres: (1) experienced a...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-016-4682-y

    authors: Park HJ,Park JW,Yang MS,Kim MY,Kim SH,Jang GC,Nam YH,Kim GW,Kim S,Park HK,Jung JW,Park JS,Kang HR

    更新日期:2017-07-01 00:00:00

  • Can magnetic resonance imaging predict the success of parturition in oxytocin-induced pregnant women?

    abstract::The aim of this study was to assess whether magnetic resonance imaging could predict the outcome of attempted vaginal delivery in a group of pregnant women whose parturition had to be induced by oxytocin. The signal intensity and morphology alterations in the cervix of 21 full-term pregnant women were analyzed before ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300051001

    authors: Sabir N,Dicle O,Yurdakul B,Akkemik B

    更新日期:2000-01-01 00:00:00

  • CT perfusion assessment of Moyamoya syndrome before and after direct revascularization (superficial temporal artery to middle cerebral artery bypass).

    abstract:PURPOSE:To evaluate the utility of CT perfusion (CTP) for the assessment of superficial temporal artery-middle cerebral artery (STA-MCA) anastomosis in patients with Moyamoya syndrome (MMS). SUBJECTS AND METHODS:Twenty-four consecutive MMS patients, who underwent unilateral STA-MCA bypass surgery, received CTP before ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3802-4

    authors: Chen Y,Xu W,Guo X,Shi Z,Sun Z,Gao L,Jin F,Wang J,Chen W,Yang Y

    更新日期:2016-01-01 00:00:00

  • 3D MR angiography with ramp-shaped flip-angle distribution.

    abstract::This study addressed the use of 3D MR angiography with flip angles (FAs) linearly varying across the excitation volume in order to diminish spin saturation. The shape of the ramp profile was varied to optimize the method for different regions and pathological alterations. Radio frequency pulses with ramp-shaped excita...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00182478

    authors: Martos J,Nägele T,Klose U,Petersen D,Voigt K

    更新日期:1996-01-01 00:00:00

  • Digital radiography.Results of a survey (part A) and a consensus conference (part B)

    abstract::Digital imaging (digital image intensifier radiography, storage phosphor/selenium radiography) is increasingly becoming commonplace in radiology departments for diagnostic purposes. Despite 10 years of experience, the advantages and disadvantages of those methods are still heavily discussed among users, financiers and...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:

    authors: Braunschweig R,Klose HJ,Neugebauer E,Busch HP

    更新日期:1997-02-21 00:00:00

  • Visualising liver fibrosis by phase-contrast X-ray imaging in common bile duct ligated mice.

    abstract:OBJECTIVES:To determine whether phase-contrast X-ray imaging can be used to visualise directly the accumulated extracellular matrix proteins associated with liver fibrosis in common bile duct ligated mice. METHODS:Twenty-six-week-old C57BL female mice were randomised into three groups. In groups 1 (n = 5) and 2 (n = 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2630-z

    authors: Zhang X,Yang XR,Chen Y,Li HQ,Li RM,Yuan QX,Zhu PP,Huang WX,Peng WJ

    更新日期:2013-02-01 00:00:00

  • Non-cardiac findings on coronary computed tomography and magnetic resonance imaging.

    abstract::Both multislice computed tomography (CT) and magnetic resonance imaging (MRI) are emerging as methods to detect coronary artery stenoses and assess cardiac function and morphology. Non-cardiac structures are also amenable to assessment by these non-invasive tests. We investigated the rate of significant and insignific...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0570-1

    authors: Dewey M,Schnapauff D,Teige F,Hamm B

    更新日期:2007-08-01 00:00:00

  • Intrahepatic dynamic contrast MR lymphangiography: initial experience with a new technique for the assessment of liver lymphatics.

    abstract:OBJECTIVES:To describe the technique and report on our initial experience with the use of intrahepatic dynamic contrast magnetic resonance lymphangiography (IH-DCMRL) for evaluation of the lymphatics in patients with hepatic lymphatic flow disorders. METHODS:This is a retrospective review of the imaging and clinical f...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06112-z

    authors: Biko DM,Smith CL,Otero HJ,Saul D,White AM,DeWitt A,Glatz AC,Piccoli DA,Mamula P,Rome JJ,Dori Y

    更新日期:2019-10-01 00:00:00

  • Holmium-166 poly(L-lactic acid) microsphere radioembolisation of the liver: technical aspects studied in a large animal model.

    abstract:OBJECTIVE:To assess the accuracy of a scout dose of holmium-166 poly(L-lactic acid) microspheres ((166)Ho-PLLA-MS) in predicting the distribution of a treatment dose of (166)Ho-PLLA-MS, using single photon emission tomography (SPECT). METHODS:A scout dose (60 mg) was injected into the hepatic artery of five pigs and S...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1613-1

    authors: Vente MA,de Wit TC,van den Bosch MA,Bult W,Seevinck PR,Zonnenberg BA,de Jong HW,Krijger GC,Bakker CJ,van het Schip AD,Nijsen JF

    更新日期:2010-04-01 00:00:00

  • Advances in ultrasound.

    abstract::Significant advances have been recently introduced into various fields of technology, taking advantage of the use of new piezoelectric materials and the large diffusion of broadband transducers. Various types of modulation may be applied to the pulse characteristics, using single pulse, multipulse or multiline techniq...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-001-1185-1

    authors: Claudon M,Tranquart F,Evans DH,Lefèvre F,Correas M

    更新日期:2002-01-01 00:00:00

  • Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI: effect of modified breath-holding method.

    abstract:OBJECTIVES:To compare the occurrence of transient severe motion (TSM) between gadoxetate disodium- and gadopentetate dimeglumine-enhanced MRI and between gadoxetate disodium-enhanced MRI scans obtained with and without the application of a modified breath-holding technique. METHODS:We reviewed 80 patients who underwen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5070-y

    authors: Song JS,Choi EJ,Park EH,Lee JH

    更新日期:2018-03-01 00:00:00

  • Contrast-induced nephropathy.

    abstract::How contrast medium-induced nephropathy (CIN) comes about is not fully understood, although CIN constitutes a leading cause of renal failure. Here, a short review of clinical trials and a more thorough outline of mechanisms thought to cause CIN are outlined. Osmolality is only one of several physicochemical properties...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s10406-005-0113-x

    authors: Persson PB

    更新日期:2005-11-01 00:00:00

  • Preservation of the endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound ablation of submucosal uterine fibroids.

    abstract:OBJECTIVE:To evaluate the integrity of endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of submucosal uterine fibroids based on contrast-enhanced MRI findings, and to identify the risk factors for endometrial impairment. METHODS:In total, 117 submucos...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4765-4

    authors: Kim YS,Kim TJ,Lim HK,Rhim H,Jung SH,Ahn JH,Lee JW,Kim BG

    更新日期:2017-09-01 00:00:00

  • Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy.

    abstract:OBJECTIVES:To investigate the diagnostic accuracy, through quantitative analysis, of contrast-enhanced ultrasound (CEUS), using a microbubble contrast agent, in the differentiation of thyroid nodules. METHODS:This prospective study enrolled 46 patients with solitary, scintigraphically non-functional thyroid nodules. T...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2385-6

    authors: Nemec U,Nemec SF,Novotny C,Weber M,Czerny C,Krestan CR

    更新日期:2012-06-01 00:00:00

  • Direct digital mammography image acquisition.

    abstract::Mammography is a branch of radiology which could benefit greatly from the assimilation of digital imaging technologies. Computerized enhancement techniques could be used to ensure optimum presentation of all clinical images. Beyond this it will facilitate powerful new clinical resources such as computer-assisted diagn...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050228

    authors: Cowen AR,Parkin GJ,Hawkridge P

    更新日期:1997-01-01 00:00:00

  • Developmental nasal midline masses in children: neuroradiological evaluation.

    abstract::Developmental nasal midline masses in children are rare lesions. Neuroimaging is essential to characterise these lesions, to determine the exact location of the lesion and most importantly to exclude a possible intracranial extension or connection. Our objective was to evaluate CT and MRI in the diagnosis of developme...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2008-3

    authors: Huisman TA,Schneider JF,Kellenberger CJ,Martin-Fiori E,Willi UV,Holzmann D

    更新日期:2004-02-01 00:00:00

  • Evaluation of sleep apnea syndrome with low-field magnetic resonance fluoroscopy.

    abstract::The aim of this study was to assess the upper airway status of sleep apnea syndrome (SAS) patients with low-field MR fluoroscopy. Twenty patients with clinically diagnosed SAS underwent upper airway monitoring using MR fluoroscopy for 5 min while awake and for 30 min while asleep. A 0.064-T permanent-magnet MR imaging...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050816

    authors: Yoshida K,Fukatsu H,Ando Y,Ishigaki T,Okada T

    更新日期:1999-01-01 00:00:00

  • Assessment of calcium scoring performance in cardiac computed tomography.

    abstract::Electron beam tomography (EBT) has been used for cardiac diagnosis and the quantitative assessment of coronary calcium since the late 1980s. The introduction of mechanical multi-slice spiral CT (MSCT) scanners with shorter rotation times opened new possibilities of cardiac imaging with conventional CT scanners. The pu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1746-y

    authors: Ulzheimer S,Kalender WA

    更新日期:2003-03-01 00:00:00

  • Transcranial Doppler ultrasonography in neurologically asymptomatic children and young adults with sickle cell disease.

    abstract::The purpose of the study was to evaluate transcranial Doppler ultrasonography for identifying cerebrovascular disease in neurologically asymptomatic children and young adults with sickle cell disease. A total of 47 consecutive patients with sickle cell disease (28 females, 19 males; age range 8 months to 29 years, mea...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1481-4

    authors: Riebel T,Kebelmann-Betzing C,Götze R,Overberg US

    更新日期:2003-03-01 00:00:00

  • Glioma imaging in Europe: A survey of 220 centres and recommendations for best clinical practice.

    abstract:OBJECTIVES:At a European Society of Neuroradiology (ESNR) Annual Meeting 2015 workshop, commonalities in practice, current controversies and technical hurdles in glioma MRI were discussed. We aimed to formulate guidance on MRI of glioma and determine its feasibility, by seeking information on glioma imaging practices f...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-018-5314-5

    authors: Thust SC,Heiland S,Falini A,Jäger HR,Waldman AD,Sundgren PC,Godi C,Katsaros VK,Ramos A,Bargallo N,Vernooij MW,Yousry T,Bendszus M,Smits M

    更新日期:2018-08-01 00:00:00

  • Meniscal body extrusion and cartilage coverage in middle-aged and elderly without radiographic knee osteoarthritis.

    abstract:OBJECTIVES:To determine meniscal extrusion and cartilage coverage on magnetic resonance (MR) images and factors associated with these parameters in knees of middle-aged and elderly persons free from radiographic tibiofemoral osteoarthritis (OA). METHODS:Seven hundred eighteen persons, free of radiographic tibiofemoral...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5741-3

    authors: Svensson F,Felson DT,Zhang F,Guermazi A,Roemer FW,Niu J,Aliabadi P,Neogi T,Englund M

    更新日期:2019-04-01 00:00:00

  • Actual role of endobronchial ultrasound (EBUS).

    abstract::Many pathologies of the airway involve the bronchial wall and the parabronchial structures. The view of the endoscopist, however, is limited to the lumen and the internal surface of the airway. Processes within the airway wall and outside the airway can only be assessed by indirect signs. Especially in malignancies, t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0497-6

    authors: Herth FJ,Eberhardt R

    更新日期:2007-07-01 00:00:00

  • Breast MRI: EUSOBI recommendations for women's information.

    abstract:UNLABELLED:This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS® categories and furth...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-3807-z

    authors: Mann RM,Balleyguier C,Baltzer PA,Bick U,Colin C,Cornford E,Evans A,Fallenberg E,Forrai G,Fuchsjäger MH,Gilbert FJ,Helbich TH,Heywang-Köbrunner SH,Camps-Herrero J,Kuhl CK,Martincich L,Pediconi F,Panizza P,Pina LJ,Pij

    更新日期:2015-12-01 00:00:00

  • Fluorescence imaging with near-infrared light: new technological advances that enable in vivo molecular imaging.

    abstract::A recent development in biomedical imaging is the non-invasive mapping of molecular events in intact tissues using fluorescence. Underpinning to this development is the discovery of bio-compatible, specific fluorescent probes and proteins and the development of highly sensitive imaging technologies for in vivo fluores...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-002-1524-x

    authors: Ntziachristos V,Bremer C,Weissleder R

    更新日期:2003-01-01 00:00:00