Asthma: comparison of dynamic oxygen-enhanced MR imaging and quantitative thin-section CT for evaluation of clinical treatment.

Abstract:

PURPOSE:To compare the use of dynamic oxygen-enhanced magnetic resonance (MR) imaging with the use of quantitatively assessed computed tomography (CT) for assessment of clinical stage and evaluation of pulmonary functional change due to treatment in patients with asthma. MATERIALS AND METHODS:The institutional review board of Kobe University Hospital approved this study, and written informed consent was obtained from each subject. Thirty consecutive patients with asthma (17 men and 13 women; age range, 27-78 years) underwent dynamic oxygen-enhanced MR imaging, multidetector CT, and assessment of forced expiratory volume in 1 second. All patients were classified as having one of four stages of asthma according to the guidelines of the National Asthma Education and Prevention Program. Relative enhancement ratio ( RER relative enhancement ratio ) and wash-in time maps were generated by means of pixel-by-pixel analyses. Regions of interest were placed on images of the lung in all sections, and all measurements were averaged to determine mean RER relative enhancement ratio and mean wash-in time for each subject. Percentage of airway wall area and mean lung density were determined at quantitative CT. For comparison of the modalities for assessment of clinical stage, indexes of subjects at all clinical stages were compared by means of the Tukey honestly significant difference test. Evaluation of pulmonary functional improvement was assessed by correlating improvement of each index with that of forced expiratory volume. RESULTS:Mean wash-in time was significantly different among patients with asthma of different clinical stages (P < .05), but significant differences between mean RER relative enhancement ratio and percentage of airway wall area were observed for a limited number of clinical stages (P < .05). Improvement of mean RER relative enhancement ratio (r = 0.63, P = .0002) and mean wash-in time (r = -0.75, P < .0001) was significantly correlated with forced expiratory volume. CONCLUSION:Dynamic oxygen-enhanced MR imaging has potential as a tool for assessment of clinical stage and evaluation of pulmonary functional change due to treatment in patients with asthma.

journal_name

Radiology

journal_title

Radiology

authors

Ohno Y,Nishio M,Koyama H,Seki S,Yoshikawa T,Matsumoto S,Obara M,van Cauteren M,Sugimura K

doi

10.1148/radiol.14132660

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

907-16

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

273

pub_type

杂志文章
  • Coronary angiographic and scintigraphic findings in experimental cardiac contusion.

    abstract::Clinical, angiographic, scintigraphic and pathologic observations in myocardial contusion were correlated. Radionuclide imaging of the injured heart with 99mTc-Sn-polyphosphate provides an accurate diagnosis in acute, even mild, myocardial contusion. The study can be carried out without danger to the critically ill pa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.3.679

    authors: Chiu CL,Roelofs JD,Go RT,Doty DB,Rose EF,Christie JH

    更新日期:1975-09-01 00:00:00

  • Complicated inferior vena cava filter retrievals: associated factors identified at preretrieval CT.

    abstract:PURPOSE:To examine filter characteristics at preretrieval computed tomography (CT) that are associated with complicated inferior vena cava (IVC) filter retrieval procedures. MATERIALS AND METHODS:This study was HIPAA compliant, and informed consent was waived. Institutional review board-approved retrospective review o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12120372

    authors: Dinglasan LA,Oh JC,Schmitt JE,Trerotola SO,Shlansky-Goldberg RD,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Mapping T2 relaxation time in the pediatric knee: feasibility with a clinical 1.5-T MR imaging system.

    abstract:PURPOSE:To determine the feasibility of mapping the spatial variation of cartilage T2 relaxation time in vivo in the pediatric knee with a 1.5-T clinical magnetic resonance (MR) imaging system and the manufacturer's body gradient coil. MATERIALS AND METHODS:Twenty-five children and adolescents (age range, 5-17 years; ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2251011461

    authors: Dardzinski BJ,Laor T,Schmithorst VJ,Klosterman L,Graham TB

    更新日期:2002-10-01 00:00:00

  • Artifacts produced by moving grids.

    abstract::Anti-scatter grids reduce the amount of secondary radiation contributing to the image and improve the signal-to-noise ratio. However, they may also lead to the creation of linear artifacts representing the shadows of the radiopaque septa. Grid motion perpendicular to the septa during the exposure can cause blurring of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.147.1.6828740

    authors: Bednarek DR,Rudin S,Wong R

    更新日期:1983-04-01 00:00:00

  • Is There an Association between STARD Statement Adherence and Citation Rate?

    abstract::Purpose To determine if adherence to the Standards for Reporting of Diagnostic Accuracy (STARD) is associated with postpublication citation rates. Materials and Methods A comprehensive search of PubMed, EMBASE, and Cochrane Library databases was performed to identify published articles that have evaluated adherence of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016151384

    authors: Dilauro M,McInnes MD,Korevaar DA,van der Pol CB,Petrcich W,Walther S,Quon J,Kurowecki D,Bossuyt PM

    更新日期:2016-07-01 00:00:00

  • Breast cancer imaging with In-111 human IgM monoclonal antibodies: preliminary studies.

    abstract::Detection of specific tumor sites was studied with scintigraphy and radiolabeled human IgM monoclonal antibodies (MoAbs). Ten patients with metastatic breast cancer received an infusion of one of three indium-111-labeled anti-breast carcinoma MoAbs. The time of infusion ranged from 30 minutes to 2 hours. Three patient...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.1.3347750

    authors: Ryan KP,Dillman RO,DeNardo SJ,DeNardo GL,Beauregard J,Hagan PL,Amox DG,Clutter ML,Burnett KG,Rulot CM

    更新日期:1988-04-01 00:00:00

  • Dynamic CT angiography after abdominal aortic endovascular aneurysm repair: influence of enhancement patterns and optimal bolus timing on endoleak detection.

    abstract:PURPOSE:To determine the time course of enhancement patterns in the aorta and endoleaks at dynamic computed tomographic (CT) angiography as well as their effect on the endoleak detection rate in patients who have undergone abdominal aortic endovascular aneurysm repair (EVAR). MATERIALS AND METHODS:This retrospective s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13120197

    authors: Lehmkuhl L,Andres C,Lücke C,Hoffmann J,Foldyna B,Grothoff M,Nitzsche S,Schmidt A,Ulrich M,Scheinert D,Gutberlet M

    更新日期:2013-09-01 00:00:00

  • Endorectal MR imaging in the evaluation of seminal vesicle invasion: diagnostic accuracy and multivariate feature analysis.

    abstract:PURPOSE:To retrospectively determine the accuracy of endorectal magnetic resonance (MR) imaging in demonstrating seminal vesicle invasion (SVI) and to investigate the MR imaging features that can predict SVI. MATERIALS AND METHODS:The Institutional Review Board granted exempt status for this retrospective study, with ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2383050657

    authors: Sala E,Akin O,Moskowitz CS,Eisenberg HF,Kuroiwa K,Ishill NM,Rajashanker B,Scardino PT,Hricak H

    更新日期:2006-03-01 00:00:00

  • Bone sarcomas in Paget disease.

    abstract::The most serious complication of Paget disease is the development of sarcoma. Forty-one cases of bone sarcoma in Paget disease, which represented our institution's entire experience, were reviewed. The relative frequency of sarcomatous degeneration was 0.9%. Histologically, 35 of 41 lesions were osteogenic sarcomas, a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.146.2.6571760

    authors: Greditzer HG 3rd,McLeod RA,Unni KK,Beabout JW

    更新日期:1983-02-01 00:00:00

  • Quantification of the left ventricular volumes and function with cine MR imaging: comparison of geometric models with three-dimensional data.

    abstract::Acquisition and measurement of left ventricular (LV) volumes with a three-dimensional data set of cine magnetic resonance (MR) images from apex to base is a time-consuming process. Results of a study with 10 healthy volunteers and 10 patients with LV hypertrophy were prospectively evaluated. The heart was shown in the...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.2.8327680

    authors: Dulce MC,Mostbeck GH,Friese KK,Caputo GR,Higgins CB

    更新日期:1993-08-01 00:00:00

  • Breast specimen radiography: evaluation of a compression device.

    abstract::The irregular shape and uneven tissue thickness of excised breast specimens makes radiographic evaluation difficult, especially when calcifications are not present. Xeroradiographs before and after compression of 20 separate excised breast specimens were compared, and 17 of the same specimens were compared after compr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.2.3393660

    authors: Chilcote WA,Davis GA,Suchy P,Paushter DM

    更新日期:1988-08-01 00:00:00

  • Posttraumatic arterial priapism in children: management with embolization.

    abstract:PURPOSE:To evaluate selective embolization for management of posttraumatic priapism in preadolescent boys and color Doppler sonography for diagnosis of the causative lesion and for planning embolization. MATERIALS AND METHODS:Five preadolescent boys with posttraumatic priapism underwent selective angiography and embol...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.1.7784590

    authors: Miller SF,Chait PG,Burrows PE,Steckler RE,Khoury AE,McLorie GA,Connolly BL,Pereira JK

    更新日期:1995-07-01 00:00:00

  • Computed tomography in metastatic disease of the brain.

    abstract::Computed tomography has been found to be a more accurate diagnostic tool in the analysis of brain metastases than radionuclide scanning. Of 1,100 patients studied by CT scan, 57 showed evidence of intracerebral metastasis, and 14 showed evidence of hydrocephalus. Density levels below that of normal brain tissue were f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/119.1.115

    authors: Deck MD,Messina AV,Sackett JF

    更新日期:1976-04-01 00:00:00

  • Case 282: Fishbone Pylephlebitis.

    abstract::HistoryA 63-year-old woman with a history of left mastectomy for breast cancer and partial gastrectomy with Roux-en-Y reconstruction for nonhealing peptic ulcer presented to the emergency department and reported a 1-month history of abdominal distention, fevers, chills, and flu-like symptoms. She was initially suspect...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020190436

    authors: Davarpanah AH,Eberhardt LW

    更新日期:2020-10-01 00:00:00

  • Male breast carcinoma and gynecomastia: comparison of mammography with sonography.

    abstract::Both ultrasonography and x-ray mammography were performed on a male patient who had breast carcinoma. While the x-ray mammographic features were highly suggestive of malignancy, the sonographic findings were subtle. Because of the technical difficulties associated with x-ray mammography of the male breast, ultrasound ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.2.6622700

    authors: Jackson VP,Gilmor RL

    更新日期:1983-11-01 00:00:00

  • Reduction of metal artifacts in patients with total hip arthroplasty with slice-encoding metal artifact correction and view-angle tilting MR imaging.

    abstract:PURPOSE:To compare the new "warp" sequence (slice-encoding metal artifact correction [SEMAC], view-angle tilting [VAT], and increased bandwidth) for the reduction of both through-plane and in-plane magnetic resonance (MR) artifacts with current optimized MR sequences in patients with total hip arthroplasty (THA). MATE...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12112408

    authors: Sutter R,Ulbrich EJ,Jellus V,Nittka M,Pfirrmann CW

    更新日期:2012-10-01 00:00:00

  • Benign and malignant breast lesions: differentiation with echo-planar MR imaging.

    abstract:PURPOSE:To quantify dynamic enhancement of breast lesions with echo-planar and conventional magnetic resonance (MR) imaging, to correlate these data with histologic findings and vessel density, and to evaluate MATERIALS AND METHODS:Twenty female patients with 22 breast lesions underwent conventional and MR echo-planar...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.1.7568850

    authors: Hulka CA,Smith BL,Sgroi DC,Tan L,Edmister WB,Semple JP,Campbell T,Kopans DB,Brady TJ,Weisskoff RM

    更新日期:1995-10-01 00:00:00

  • White Matter by Diffusion MRI Following Methylphenidate Treatment: A Randomized Control Trial in Males with Attention-Deficit/Hyperactivity Disorder.

    abstract::BackgroundMethylphenidate (MPH) is highly effective in treating attention-deficit/hyperactivity disorder (ADHD). However, not much is known about its effect on the development of human brain white matter (WM).PurposeTo determine whether MPH modulates WM microstructure in an age-dependent fashion in a randomized double...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2019182528

    authors: Bouziane C,Filatova OG,Schrantee A,Caan MWA,Vos FM,Reneman L

    更新日期:2019-10-01 00:00:00

  • Qualitative Radiogenomics: Association between Oncotype DX Test Recurrence Score and BI-RADS Mammographic and Breast MR Imaging Features.

    abstract::Purpose To evaluate the association between Breast Imaging Reporting and Data System (BI-RADS) mammographic and magnetic resonance (MR) imaging features and breast cancer recurrence risk in patients with estrogen receptor-positive breast cancer who underwent the Oncotype DX assay. Materials and Methods In this institu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017162333

    authors: Woodard GA,Ray KM,Joe BN,Price ER

    更新日期:2018-01-01 00:00:00

  • Functional CT quantification of tumor perfusion after transhepatic arterial embolization in a rat model.

    abstract:PURPOSE:To quantify tumor perfusion after transcatheter arterial embolization (TAE) with functional computed tomography (CT) and to validate the reproducibility of quantification measurements. MATERIALS AND METHODS:This study was conducted in accordance with an institutional animal care and use committee-approved prot...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2371040526

    authors: Kan Z,Kobayashi S,Phongkitkarun S,Charnsangavej C

    更新日期:2005-10-01 00:00:00

  • Acute knee trauma: value of a short dedicated extremity MR imaging examination for prediction of subsequent treatment.

    abstract:PURPOSE:To assess the predictive value of a short magnetic resonance (MR) imaging examination, in addition to or instead of radiography, performed in patients with acute knee trauma to identify those who require additional treatment versus those who do not and can be discharged without further follow-up. MATERIALS AND...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiol.2341031062

    authors: Oei EH,Nikken JJ,Ginai AZ,Krestin GP,Verhaar JA,van Vugt AB,Hunink MG

    更新日期:2005-01-01 00:00:00

  • The significance of residual disease after external irradiation of squamous-cell carcinoma of the oropharynx.

    abstract::366 patients with squamous-cell carcinoma of the oropharynx treated by external irradiation were studied to see whether residual disease at the end of treatment influences control. The frequency of recurrence was found to be significantly greater when residual disease was present. When the total dose was determined by...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.2.493

    authors: Barkley HT,Fletcher GH

    更新日期:1977-08-01 00:00:00

  • The Effect of Modality and Landmark Selection on MRI and CT Femoral Torsion Angles.

    abstract::Background Assessment of femoral torsion at preoperative hip imaging is commonly recommended. However, it is unclear whether MRI is as accurate as CT and how different methods affect femoral torsion measurements. Purpose To compare MRI- and CT-based assessment of femoral torsion by using four commonly used measurement...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020192723

    authors: Schmaranzer F,Kallini JR,Miller PE,Kim YJ,Bixby SD,Novais EN

    更新日期:2020-08-01 00:00:00

  • The cause of superior vena cava syndrome: diagnosis with percutaneous atherectomy.

    abstract::The cause of superior vena cava syndrome (SVCS) in two patients was identified by means of endovascular biopsy of the superior vena cava (SVC) performed with a percutaneous atherectomy catheter. In both cases, the extracted tissues were neoplastic, therefore obviating additional invasive procedures. After a specific d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.174-3-957

    authors: Dake MD,Zemel G,Dolmatch BL,Katzen BT

    更新日期:1990-03-01 00:00:00

  • Thermography, mammography, and clinical examination in breast cancer screening. Review of 16,000 studies.

    abstract::Breast cancer screening detected 139 biopsy-proved malignancies in 16,000 slef-selected women (8.7/1,000). In these, xeroradiography detected 78% (109), clinical examination 55% (76), and thermography 39% (54). In all 16,000 women, the thermogram was interpreted as positive in 17.9% (2,864). The greatest effectiveness...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.1.123

    authors: Feig SA,Shaber GS,Schwartz GF,Patchefsky A,Libshitz HI,Edeiken J,Nerlinger R,Curley RF,Wallace JD

    更新日期:1977-01-01 00:00:00

  • MR imaging of apparent small-bowel perfusion for diagnosing mesenteric ischemia: feasibility study.

    abstract::The purpose of this study, which was approved by the institutional review board, was to assess the differentiation of individuals with from those without mesenteric ischemia. All subjects provided written informed consent. Six healthy volunteers and six patients with documented chronic mesenteric ischemia underwent ma...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2342031002

    authors: Lauenstein TC,Ajaj W,Narin B,Göhde SC,Kröger K,Debatin JF,Rühm SG

    更新日期:2005-02-01 00:00:00

  • Medial brachial fascial compartment syndrome: anatomic basis of neuropathy after transaxillary arteriography.

    abstract::The authors reviewed their experience with 320 transaxillary arteriograms, as well as the English-language literature on neuropathy complicating transaxillary arteriography. Three of their patients had median and ulnar motor and sensory nerve injury, and six others had only sensory involvement. The occurrence or sever...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.173.1.2675180

    authors: Smith DC,Mitchell DA,Peterson GW,Will AD,Mera SS,Smith LL

    更新日期:1989-10-01 00:00:00

  • Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate--pharmacokinetic analysis and experimental porcine model.

    abstract:PURPOSE:To investigate the effect of injection rate of contrast medium on aortic and hepatic peak enhancement at computed tomography. MATERIALS AND METHODS:Early pharmacokinetics of contrast enhancement was analyzed theoretically and simulated with a compartment model. Contrast enhancement curves were generated from t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.206.2.9457200

    authors: Bae KT,Heiken JP,Brink JA

    更新日期:1998-02-01 00:00:00

  • Vena caval filter splaying: potential complication of use of the titanium Greenfield filter.

    abstract::Significant structural and mechanical differences exist between the titanium and stainless steel versions of the Greenfield filter (GF). The titanium GF has a longer leg length (49 mm vs 43 mm), a greater span (38.5 mm vs 28.0 mm), and a larger hook angle (41 degrees vs 23.5 degrees). In vitro tests demonstrated appro...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.3.2813790

    authors: Teitelbaum GP,Jones DL,van Breda A,Matsumoto AH,Fellmeth BD,Chespak LW,Barth KH

    更新日期:1989-12-01 00:00:00

  • What the diagnostic radiologist needs to know about radiation oncology.

    abstract::Substantial technologic advances in radiation treatment planning and delivery have made possible exquisite tailoring of three-dimensional radiation dose distributions that conform to the tumor treatment volume while avoiding adjacent normal tissues. Although such highly precise treatment can increase the therapeutic r...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.11101688

    authors: Terezakis SA,Heron DE,Lavigne RF,Diehn M,Loo BW Jr

    更新日期:2011-10-01 00:00:00