Abstract:
:The optimum time interval for 10 ml boluses of bupivacaine 0.0625% + fentanyl 2 μg.ml-1 as part of a programmed intermittent epidural bolus regimen has been found to be 40 min. This regimen was shown to be effective without the use of supplementary patient-controlled epidural analgesia boluses in 90% of women during the first stage of labour, although with a rate of sensory block to ice above T6 in 34% of women. We aimed to determine the optimum programmed intermittent epidural bolus volume at a 40 min interval to provide effective analgesia in 90% of women (EV90 ) during the first stage of labour, without the use of patient-controlled epidural analgesia. We performed a prospective double-blind dose-finding study using the biased coin up-and-down sequential allocation method in 40 women. The estimated EV90 was 11.0 (95%CI 10.0-11.7) ml with the isotonic regression method and 10.7 (95%CI 10.3-11.0) ml with the truncated Dixon and Mood method. Overall, 18 women had a sensory block above T6, and 37 women exhibited no motor block. No women required treatment for hypotension. In conclusion, it is not possible to reduce the programmed intermittent epidural bolus volume from 10 ml, used in our current regimen, without compromising the quality of analgesia. Using this regimen, a high proportion of women will develop a sensory block above T6.
journal_name
Anaesthesiajournal_title
Anaesthesiaauthors
Zakus P,Arzola C,Bittencourt R,Downey K,Ye XY,Carvalho JCdoi
10.1111/anae.14159subject
Has Abstractpub_date
2018-04-01 00:00:00pages
459-465issue
4eissn
0003-2409issn
1365-2044journal_volume
73pub_type
杂志文章,随机对照试验相关文献
ANAESTHESIA文献大全abstract::Fifty ASA 1 or 2 patients scheduled to undergo major gynaecological surgery were allocated randomly to one of two groups. All patients received a standard anaesthetic regimen. Patients in group 1 received droperidol 1.25 mg given intravenously 20 min prior to the end of surgery and a patient-controlled analgesia infus...
journal_title:Anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1365-2044.1995.tb15124.x
更新日期:1995-07-01 00:00:00
abstract::Severe acute respiratory syndrome-corona virus-2, which causes coronavirus disease 2019 (COVID-19), is highly contagious. Airway management of patients with COVID-19 is high risk to staff and patients. We aimed to develop principles for airway management of patients with COVID-19 to encourage safe, accurate and swift ...
journal_title:Anaesthesia
pub_type: 杂志文章,实务指引
doi:10.1111/anae.15054
更新日期:2020-06-01 00:00:00
abstract::We sought to determine whether the forced air convection warmers (nine Bair Huggers, Augustine Medical, and one Warm Touch, Mallinkrodt Medical) used in our operating theatres could be a source of microbial pathogens. Agar plates were placed directly in the air stream of the warmers. Four of these grew potentially pat...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/j.1365-2044.1997.250-az0384.x
更新日期:1997-11-01 00:00:00
abstract::Difficulty in tracheal intubation in paediatric intensive care patients is associated with increased morbidity and mortality. Delays to intubation and interruption to oxygenation and ventilation are poorly tolerated. We developed a safe and atraumatic tracheal intubation technique. A floppy-tipped guidewire and airway...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/anae.14008
更新日期:2017-11-01 00:00:00
abstract::The aim of this double-blind, randomised study was to assess the effects of the addition of 0.5 mg of vecuronium bromide to a standard local anaesthetic mixture used for peribulbar anaesthesia. We studied 60 patients undergoing regional anaesthesia for intra-ocular surgery and were primarily interested in the quality ...
journal_title:Anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1046/j.1365-2044.1998.00433.x
更新日期:1998-06-01 00:00:00
abstract::Anaesthetic equipment was studied to determine whether the accuracy was improved and failure rate decreased by routine maintenance and calibration by a biomedical technician. Each piece was evaluated, and then repaired and rechecked at intervals by the same technician. Equipment failures were divided into three types:...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/j.1365-2044.1985.tb10505.x
更新日期:1985-01-01 00:00:00
abstract::The Acquired Immune Deficiency Syndrome (AIDS) is a group of conditions which is reaching epidemic proportions. It is caused by a virus new to man, with an as yet poorly understood natural history, ominous prognosis and no known cure. Anaesthetists should be aware of the implications of dealing with increasing numbers...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/j.1365-2044.1986.tb12743.x
更新日期:1986-10-01 00:00:00
abstract::The laryngeal mask airway was used in 200 children during a variety of surgical procedures. Some problem with the use of the device was encountered in 47 cases (23%), but in only five cases (2.5%) were the problems serious enough to warrant abandonment of its use. A clear airway was ultimately achieved in 191 children...
journal_title:Anaesthesia
pub_type: 临床试验,杂志文章
doi:10.1111/j.1365-2044.1990.tb14449.x
更新日期:1990-09-01 00:00:00
abstract::A 68-year-old woman presented with dyspnoea having undergone a short period of tracheal intubation during an episode of congestive cardiac failure 10 days earlier. On the fourth day of admission, she suddenly developed acute respiratory distress followed by a cardiac arrest and was found to have an enlarging neck mass...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/j.1365-2044.1997.72-az0069.x
更新日期:1997-02-01 00:00:00
abstract::Spinal anaesthesia is a safe, routinely performed procedure. However, in patients with lumbar cutaneous abnormities or deformities of the lower extremities, a previously undetected spinal anomaly may be present. In such patients, it may be prudent to avoid central neuraxial block to prevent neural damage. This instruc...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1046/j.1365-2044.2001.01916.x
更新日期:2001-08-01 00:00:00
abstract::The use of intra-operative Doppler oesophageal probes provides continuous monitoring of cardiac output. This enables optimisation of intravascular volume and tissue perfusion in major abdominal surgery, which is thought to reduce postoperative complications and shorten hospital stay. Medline and EMBASE were searched u...
journal_title:Anaesthesia
pub_type: 杂志文章,meta分析,评审
doi:10.1111/j.1365-2044.2007.05233.x
更新日期:2008-01-01 00:00:00
abstract::The measurement of extravascular lung water is a relatively new technology which has not yet been well validated as a clinically useful tool. We studied its utility in patients undergoing pulmonary endarterectomy as they frequently suffer reperfusion lung injury and associated oedematous lungs. Such patients are there...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/anae.14744
更新日期:2019-10-01 00:00:00
abstract::The efficient use of operating theatres requires accurate case scheduling. One common method is 'booking to the mean'. Here, the mean times for individual operations are summed to approximate the time allocated to the list. An alternative approach is 'probabilistic scheduling'. Here, the means and standard deviation o...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/anae.14958
更新日期:2020-05-01 00:00:00
abstract::Propofol has been shown to cause pain on injection. This study investigated the effect of warming propofol to 37 degrees C on the pain of intravenous injection. One hundred and one women on outpatient gynaecology lists were allocated to receive propofol either at room temperature or at 37 degrees C. Warming propofol d...
journal_title:Anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1365-2044.1996.tb07802.x
更新日期:1996-05-01 00:00:00
abstract::The haemostatic management of major obstetric haemorrhage remains challenging, and current published guidance relies heavily on experience from the non-pregnant population and expert opinion. In recent years, an interest in the implications of relative hypofibrinogenaemia, point-of-care monitoring of coagulation abnor...
journal_title:Anaesthesia
pub_type: 杂志文章,评审
doi:10.1111/anae.12913
更新日期:2015-01-01 00:00:00
abstract::The statement that amniotic fluid embolism is the most dangerous and untreatable condition in obstetrics appears to be true. It must be suspected in any patient who collapses or bleeds excessively during labour or the immediate post-partum period. Attempts should be made to secure a definitive diagnosis in life by exa...
journal_title:Anaesthesia
pub_type: 杂志文章,评审
doi:10.1111/j.1365-2044.1979.tb04862.x
更新日期:1979-01-01 00:00:00
abstract::Isotonic saline is a widely-used infusion fluid, although the associated chloride load may cause metabolic acidosis and impair kidney function in young, healthy volunteers. We wished to examine whether these effects also occurred in the elderly, and conducted a crossover study in 13 men with a mean age of 73 years (ra...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/anae.13301
更新日期:2016-02-01 00:00:00
abstract::The demyelinating diseases are classified and the current concepts of the aetiology and pathophysiology of the most common of these diseases, multiple sclerosis, are described. The effects of the impaired function, local responses and known complications of the disease on the choice of anaesthetic, drugs and technique...
journal_title:Anaesthesia
pub_type: 杂志文章,评审
doi:10.1111/j.1365-2044.1980.tb03947.x
更新日期:1980-09-01 00:00:00
abstract::A review is presented of animal studies of the selective steroidal neuromuscular blocking drug binding agent sugammadex. These studies demonstrate that sugammadex is faster in onset than the currently used acetylcholinesterase inhibitors, has no muscarinic effects, and is characterised by lack of adverse effects on ot...
journal_title:Anaesthesia
pub_type: 杂志文章,评审
doi:10.1111/j.1365-2044.2008.05869.x
更新日期:2009-03-01 00:00:00
abstract::The Laryngeal Tube S and the LMA-ProSeal are supraglottic instruments with an improved airway seal and a drainage tube to protect against regurgitation and to facilitate passage of a gastric tube. We compared the feasibility of these two instruments in a randomised, controlled clinical trial. One hundred and sixty pat...
journal_title:Anaesthesia
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1365-2044.2007.05073.x
更新日期:2007-07-01 00:00:00
abstract::We thought that delirium might be less frequent after transcatheter aortic valve implantation via the femoral artery compared with via the cardiac apex. We reviewed 210 patients who underwent transcatheter aortic valve implantation between January 2009 and October 2014. The proportion (95% CI) of patients who suffered...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/anae.13524
更新日期:2016-08-01 00:00:00
abstract::Artificial nasopharyngeal airway position and performance were assessed in 120 anaesthetised adult patients. Using a fibreoptic laryngoscope mean distances from nares to larynx were measured at 209 mm (SD 11) in males and 180 mm (SD 11) in females; those from nares to epiglottis were 159 mm (SD 12) in males and 140 mm...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/j.1365-2044.1993.tb07119.x
更新日期:1993-07-01 00:00:00
abstract::A 34-year-old female patient developed methaemoglobinaemia following a femoral nerve block using prilocaine. The concentrations of methaemoglobin in the blood of the next eight patients receiving this block were assayed, and found to be significantly increased above baseline concentrations, but very significantly less...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/j.1365-2044.1992.tb04212.x
更新日期:1992-12-01 00:00:00
abstract::The influence of route of administration (extradural as compared with intravenous) of diamorphine 0.5 mg/hour as a supplement to extradural bupivacaine (0.125% at 15 ml/hour) was investigated in two groups of 20 patients who underwent major abdominal gynaecological surgery. Significantly more patients in the intraveno...
journal_title:Anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1365-2044.1991.tb11680.x
更新日期:1991-06-01 00:00:00
abstract::The effect of neostigmine on neuromuscular function was examined after spontaneous recovery from an atracurium-induced neuromuscular blockade, which reached a train-of-four ratio of either 0.5 or 0.9. Two doses of neostigmine 2.5 mg were given 5 minutes apart. Neuromuscular recovery was assessed with train-of-four and...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/j.1365-2044.1989.tb11280.x
更新日期:1989-04-01 00:00:00
abstract::Capnography (ETCO2 ) is routinely used as a non-invasive estimate of arterial carbon dioxide (PaCO2 ) levels in order to modify ventilatory settings, whereby it is assumed that there is a positive gap between PaCO2 and ETCO2 of approximately 0.5 kPa. However, negative values (ETCO2 > PaCO2 ) can be observed. We retros...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/anae.13969
更新日期:2017-11-01 00:00:00
abstract::There are numerous possible techniques for delivering local anaesthetic through peripheral nerve catheters. These include continuous infusions, patient-controlled boluses and programmed intermittent boluses. The optimal delivery regimen of local anaesthetic is yet to be conclusively established. In this review, we ide...
journal_title:Anaesthesia
pub_type: 杂志文章,meta分析
doi:10.1111/anae.14864
更新日期:2020-03-01 00:00:00
abstract::Two anaesthetic procedures that did not include nitrous oxide were compared in a randomised study of 50 patients for tympanoplasty and tympanoscopy: propofol given for induction and maintenance, and thiopentone-isoflurane given for induction and maintenance, respectively. Induction in the first group was with a bolus ...
journal_title:Anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1365-2044.1988.tb09083.x
更新日期:1988-03-01 00:00:00
abstract::Forty anaesthetists, of all grades, were interviewed without prior warning and questioned about the checks they had performed on their anaesthetic equipment before use. The results reveal that a substantial percentage (up to 41%) of anaesthetists perform inadequate checks. Furthermore, of those that do, few follow the...
journal_title:Anaesthesia
pub_type: 杂志文章
doi:10.1111/j.1365-2044.1992.tb03151.x
更新日期:1992-10-01 00:00:00
abstract::A clinical trial was performed to compare the effects of intramuscular dihydrocodeine with caudal bupivacaine on postoperative pain and recovery in 181 children who had undergone either circumcision, inguinal herniotomy or orchidopexy performed under general anaesthesia. Linear analogues were used in assess level of c...
journal_title:Anaesthesia
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1365-2044.1982.tb01717.x
更新日期:1982-10-01 00:00:00