Speech Detection in Noise for Young Bilaterally Implanted Children: Is There Evidence of Binaural Benefit Over the Shadowed Ear Alone?

Abstract:

OBJECTIVES:To measure binaural benefit over the shadowed ear alone for young bilateral cochlear implant (CI) users. It was hypothesized that children who received bilateral CIs at a young age (<4 years), and had significant bilateral experience, would demonstrate lower detection thresholds for speech sounds in background noise in the bilateral CI over the unilateral CI condition when the added CI was ipsilateral to the noise source. DESIGN:Children receiving bilateral CIs at the Eye and Ear Hospital Clinic in Melbourne were invited to participate in a wider research project evaluating outcomes; those participating in the wider project who were bilaterally implanted by 4 years and were approximately 2 years postoperative were included in the present study. For 20 participants, detection signal to noise ratios (SNRs) were measured for speech presented from in front and noise from 90° in at least 3 of 4 device/noise conditions, namely left CI/noise right and right CI/noise left, plus bilateral CIs/noise right and bilateral CIs/noise left. RESULTS:As some participants could only complete testing in 3 conditions within the 1 test block, the unilateral versus bilateral comparison was performed for 1 CI (i.e., 1 noise direction) for 15 participants and for both CIs (i.e., noise left and noise right) for 5 participants. Group analysis indicated no significant difference in detection SNR between the unilateral and bilateral CI conditions when adding the left CI or right CI (for the overall group) or when adding the first or second CI (for the 15 participants with sequential bilateral CIs). Separate analyses indicated no significant difference in detection SNR between the unilateral and bilateral CI conditions for the majority of individuals; this occurred irrespective of whether the analysis indicated that the CI added in the bilateral condition was poorer-performing, better-performing, or not significantly different compared with the other CI. Four individuals demonstrated a significant improvement in the bilateral condition when the CI added in the bilateral condition was a better-performing (n = 1), poorer-performing (n = 2), or not significantly different CI (n = 1). There was no relationship between the detection SNR difference between each CI and the detection SNR difference between the unilateral and bilateral conditions. CONCLUSIONS:The hypothesis of a lower detection SNR in the bilateral condition was not supported by the group results or by the results for the majority of individuals. For the 4 participants who did demonstrate benefit over the shadowed ear alone, that benefit cannot be separated from the potential benefit gained as a result of the CI added in the bilateral condition being the better-performing CI for 1 of the 4. Variation in outcomes could not be related to demographic factors for this group, which was relatively homogeneous for age at bilateral CI and experience; an older, more experienced group may demonstrate greater binaural benefit in these conditions. These results can be used during counseling for families regarding postoperative expectations for young children, especially in the first 2 years.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Galvin KL,Dowell RC,van Hoesel RJ,Mok M

doi

10.1097/AUD.0000000000000442

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

e325-e334

issue

6

eissn

0196-0202

issn

1538-4667

journal_volume

38

pub_type

杂志文章
  • Identification of middle ear effusion by aural acoustic admittance and otoscopy.

    abstract::The ability of aural acoustic immittance measures and validated pneumatic otoscopy to identify middle ear effusion (MEE) was determined for a group of children with chronic or recurrent otitis media. The measures were made immediately prior to surgery for placement of tympanostomy tubes, with the validating diagnosis ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199408000-00005

    authors: Nozza RJ,Bluestone CD,Kardatzke D,Bachman R

    更新日期:1994-08-01 00:00:00

  • A sensitive period for the development of the central auditory system in children with cochlear implants: implications for age of implantation.

    abstract:OBJECTIVE:The aim of the present experiment was to assess the consequences of cochlear implantation at different ages on the development of the human central auditory system. DESIGN:Our measure of the maturity of central auditory pathways was the latency of the P1 cortical auditory evoked potential. Because P1 latenci...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200212000-00004

    authors: Sharma A,Dorman MF,Spahr AJ

    更新日期:2002-12-01 00:00:00

  • Peripheral Auditory Involvement in Childhood Listening Difficulty.

    abstract:OBJECTIVES:This study tested the hypothesis that undetected peripheral hearing impairment occurs in children with idiopathic listening difficulties (LiDs), as reported by caregivers using the Evaluation of Children"s Listening and Processing Skills (ECLiPS) validated questionnaire, compared with children with typically...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000899

    authors: Hunter LL,Blankenship CM,Lin L,Sloat NT,Perdew A,Stewart H,Moore DR

    更新日期:2020-06-25 00:00:00

  • Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant.

    abstract:OBJECTIVES:This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN:Eight CI listeners with contralateral acoustic hearing ranging fr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000708

    authors: Dirks C,Nelson PB,Sladen DP,Oxenham AJ

    更新日期:2019-11-01 00:00:00

  • The mismatch negativity: a powerful tool for cognitive neuroscience.

    abstract::This article reviews research on the relatively recently discovered event-related potential component, the mismatch negativity (MMN), which is of great potential interest for understanding central auditory function and various forms of its pathology. This change-specific response can serve as an accurate objective mea...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:

    authors: Näätänen R

    更新日期:1995-02-01 00:00:00

  • The effect of hearing aid microphone mode on performance in an auditory orienting task.

    abstract:OBJECTIVES:Although directional microphones on a hearing aid provide a signal-to-noise ratio benefit in a noisy background, the amount of benefit is dependent on how close the signal of interest is to the front of the user. It is assumed that when the signal of interest is off-axis, users can reorient themselves to the...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000053

    authors: Brimijoin WO,Whitmer WM,McShefferty D,Akeroyd MA

    更新日期:2014-09-01 00:00:00

  • Distortion product otoacoustic emission test performance for a priori criteria and for multifrequency audiometric standards.

    abstract:OBJECTIVES:1) To describe distortion product otoacoustic emission (DPOAE) test performance when a priori response criteria are applied to a large set of DPOAE data. 2) To describe DPOAE test performance when multifrequency definitions of auditory function are used. 3) To determine DPOAE test performance when a single d...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199908000-00007

    authors: Gorga MP,Neely ST,Dorn PA

    更新日期:1999-08-01 00:00:00

  • Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off.

    abstract:OBJECTIVES:We investigated the ability of single-sided deaf listeners implanted with a cochlear implant (SSD-CI) to (1) determine the front-back and left-right location of sound sources presented from loudspeakers surrounding the listener and (2) use small head rotations to further improve their localization performanc...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000882

    authors: Pastore MT,Natale SJ,Clayton C,Dorman MF,Yost WA,Zhou Y

    更新日期:2020-11-01 00:00:00

  • SSW test performance-intensity functions for hearing-impaired adults.

    abstract::The present study investigated the effects of intensity on hearing-impaired adults' performance on the Staggered Spondaic Word (SSW) test. Fifteen adults having mild-to-moderate cochlear hearing losses were administered the 40-item SSW test which was subdivided into four groups of ten items each, and presented at diff...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198411000-00004

    authors: Flynn PA,Danhauer JL,Gerber SE,Goller MC,Arnst DJ

    更新日期:1984-11-01 00:00:00

  • The measurement of performance asymmetries with dichotic stimulus presentation.

    abstract::The failure to include only relevant observations in the assessment of laterality has resulted in a proliferation of post hoc attempts to "correct" laterality measures influenced by "overall performance level." The inclusion of information from trials in which both ears were either correct or in error contaminates the...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198405000-00010

    authors: Hughes LF,Miller CJ

    更新日期:1984-05-01 00:00:00

  • Development of the Connected Speech Test (CST).

    abstract::This paper describes the first phase in the development of the Connected Speech Test (CST). This test of intelligibility of everyday speech has been developed primarily for use as a criterion measure in investigations of hearing aid benefit. The test consists of 48 passages of conversationally produced connected speec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198710001-00010

    authors: Cox RM,Alexander GC,Gilmore C

    更新日期:1987-10-01 00:00:00

  • Hearing function in patients living with HIV/AIDS.

    abstract:OBJECTIVES:During the earlier years of the HIV/AIDS epidemic, initial reports described sensorineural hearing loss in up to 49% of individuals with HIV/AIDS. During those years, patients commonly progressed to advanced stages of HIV disease and frequently had neurological complications. However, the abnormalities on pu...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000064

    authors: Luque AE,Orlando MS,Leong UC,Allen PD,Guido JJ,Yang H,Wu H

    更新日期:2014-11-01 00:00:00

  • Application of the kurtosis statistic to the evaluation of the risk of hearing loss in workers exposed to high-level complex noise.

    abstract:OBJECTIVE:Develop dose-response relations for two groups of industrial workers exposed to Gaussian or non-Gaussian (complex) types of continuous noises and to investigate what role, if any, the kurtosis statistic can play in the evaluation of industrial noise-induced hearing loss (NIHL). DESIGN:Audiometric and noise e...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181d94e68

    authors: Zhao YM,Qiu W,Zeng L,Chen SS,Cheng XR,Davis RI,Hamernik RP

    更新日期:2010-08-01 00:00:00

  • Changes in the Compressive Nonlinearity of the Cochlea During Early Aging: Estimates From Distortion OAE Input/Output Functions.

    abstract:OBJECTIVES:The level-dependent growth of distortion product otoacoustic emissions (DPOAEs) provides an indirect metric of cochlear compressive nonlinearity. Recent evidence suggests that aging reduces nonlinear distortion emissions more than those associated with linear reflection. Therefore, in this study, we generate...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000319

    authors: Ortmann AJ,Abdala C

    更新日期:2016-09-01 00:00:00

  • Nonsense syllable test (NST) results and hearing loss.

    abstract::Errors on a nonsense syllable test (NST) were compared to pure-tone thresholds and ages of 109 subjects with normal or sensorineural hearing loss. A strong correlation was found between the number of NST errors and hearing loss at 2000 and 250 Hz. NST errors do not appear to be related to the age of subjects. Excellen...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198702000-00008

    authors: Butts FM,Ruth RR,Schoeny ZG

    更新日期:1987-02-01 00:00:00

  • Transcutaneous vagus nerve stimulation modulates tinnitus-related beta- and gamma-band activity.

    abstract:OBJECTIVES:The ability of a treatment method to interfere with tinnitus-related neural activity patterns, such as cortical gamma rhythms, has been suggested to indicate its potential in relieving tinnitus. Therapeutic modulation of gamma-band oscillations with vagus nerve stimulation has been recently reported in epile...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0000000000000123

    authors: Hyvärinen P,Yrttiaho S,Lehtimäki J,Ilmoniemi RJ,Mäkitie A,Ylikoski J,Mäkelä JP,Aarnisalo AA

    更新日期:2015-05-01 00:00:00

  • Monothermal Caloric Screening to Improve Healthcare Value.

    abstract:OBJECTIVES:To evaluate whether monothermal caloric screening can reduce the number of caloric irrigations required in the vestibular testing battery while maintaining diagnostic accuracy. DESIGN:Prospective controlled cohort study. Three hundred and ninety patients referred for vestibular testing at this tertiary refe...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000262

    authors: Thatcher AL,Beckerman ML,Telian SA,King WM

    更新日期:2016-05-01 00:00:00

  • The contribution of amplitude envelope cues to sentence identification in young and aged listeners.

    abstract:OBJECTIVE:The purpose of this study was to examine the importance of amplitude envelope cues to sentence identification for aged listeners. We also examined the effect of increasing alterations (i.e., compression ratio) and amount of available frequency content (i.e., number of channels) for this population. DESIGN:Th...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200104000-00004

    authors: Souza PE,Kitch V

    更新日期:2001-04-01 00:00:00

  • Speech perception using maps based on neural response telemetry measures.

    abstract:OBJECTIVE:To determine how speech perception is affected for Nucleus cochlear implant users when their speech processor is programmed using neural response telemetry (NRT) measures rather than traditional behavioral estimates of threshold and maximum comfort level. DESIGN:Electrically evoked compound action potential ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200202001-00009

    authors: Seyle K,Brown CJ

    更新日期:2002-02-01 00:00:00

  • A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users.

    abstract:OBJECTIVE:The primary goal of this study was to examine changes that may occur in electrode impedance, electrically evoked compound action potential (EAP) threshold and slope of the EAP growth function, and behavioral measures of threshold T-level) and maximum comfort (C-level) over time in both adult and child cochlea...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200112000-00004

    authors: Hughes ML,Vander Werff KR,Brown CJ,Abbas PJ,Kelsay DM,Teagle HF,Lowder MW

    更新日期:2001-12-01 00:00:00

  • Search for Electrophysiological Indices of Hidden Hearing Loss in Humans: Click Auditory Brainstem Response Across Sound Levels and in Background Noise.

    abstract:OBJECTIVES:Recent studies in animals indicate that even moderate levels of exposure to noise can damage synaptic ribbons between the inner hair cells and auditory nerve fibers without affecting audiometric thresholds, giving rise to the use of the term "hidden hearing loss" (HHL). Despite evidence across several animal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000905

    authors: Suresh CH,Krishnan A

    更新日期:2020-07-13 00:00:00

  • Melodic contour identification by cochlear implant listeners.

    abstract:OBJECTIVE:While the cochlear implant provides many deaf patients with good speech understanding in quiet, music perception and appreciation with the cochlear implant remains a major challenge for most cochlear implant users. The present study investigated whether a closed-set melodic contour identification (MCI) task c...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000261689.35445.20

    authors: Galvin JJ 3rd,Fu QJ,Nogaki G

    更新日期:2007-06-01 00:00:00

  • Bilateral and unilateral cochlear implant users compared on speech perception in noise.

    abstract:OBJECTIVE:Compare speech performance in noise with matched bilateral cochlear implant (CICI) and unilateral cochlear implant (CI only) users. DESIGN:Thirty CICI and 30 CI-only subjects were tested on a battery of speech perception tests in noise that use an eight-loudspeaker array. RESULTS:On average, CICI subject's ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181c12383

    authors: Dunn CC,Noble W,Tyler RS,Kordus M,Gantz BJ,Ji H

    更新日期:2010-04-01 00:00:00

  • Predictive properties of the video head impulse test: measures of caloric symmetry and self-report dizziness handicap.

    abstract:OBJECTIVES:The purpose of this investigation was to determine whether a predictable relationship existed between self-reported dizziness handicap and video Head Impulse Test (vHIT) results in a large sample of patients reporting to a dizziness clinic. Secondary objectives included describing the characteristics of the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000047

    authors: McCaslin DL,Jacobson GP,Bennett ML,Gruenwald JM,Green AP

    更新日期:2014-09-01 00:00:00

  • Auditory perception changes after reimplantation in a child cochlear implant user.

    abstract::The ability to remove cochlear implants from children and subsequently reimplant a more complex device in the same ear was the concern of this single case study. A postlinguistically deafened child, J.L., received a single-channel cochlear implant 1 yr after contracting meningitis and suffering a profound bilateral se...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199206000-00009

    authors: Chute PM,Hellman SA,Parisier SC,Tartter VC,Economou A

    更新日期:1992-06-01 00:00:00

  • A Bayesian perspective on tinnitus pitch matching.

    abstract:OBJECTIVES:New tinnitus therapies are being developed and marketed that target the patient's tinnitus frequency. This frequency is estimated clinically by pitch matching, which has the patient identify the pure tone that is closest to the perceived tinnitus frequency. Though widely used, pitch matching is heavily criti...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000081

    authors: McMillan GP,Thielman EJ,Wypych K,Henry JA

    更新日期:2014-11-01 00:00:00

  • Auditory development reflected by middle latency response.

    abstract::The auditory middle latency response (MLR) seems to have a relatively long developmental time course, extending through the first decade of life. Characteristics of each MLR component change developmentally not only with respect to waveform morphology but also with respect to response reliability, dependence on awaren...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-199610000-00008

    authors: McGee T,Kraus N

    更新日期:1996-10-01 00:00:00

  • Restoring Perceived Loudness for Listeners With Hearing Loss.

    abstract:OBJECTIVES:Normalizing perceived loudness is an important rationale for gain adjustments in hearing aids. It has been demonstrated that gains required for restoring normal loudness perception for monaural narrowband signals can lead to higher-than-normal loudness in listeners with hearing loss, particularly for binaura...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000521

    authors: Oetting D,Hohmann V,Appell JE,Kollmeier B,Ewert SD

    更新日期:2018-07-01 00:00:00

  • Comparison of cognitive function in deaf children between before and after cochlear implant.

    abstract:OBJECTIVES:This study was conducted to examine improvements of cognitive abilities after cochlear implantation in deaf children. We also examined the psychosocial factors that predict good outcomes of cochlear implantation. DESIGN:A neuropsychological test battery was administered to 17 deaf children (mean age, 7 yr 2...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318031541b

    authors: Shin MS,Kim SK,Kim SS,Park MH,Kim CS,Oh SH

    更新日期:2007-04-01 00:00:00

  • Auditory Distraction and Acclimatization to Hearing Aids.

    abstract:OBJECTIVE:It is widely recognized by hearing aid users and audiologists that a period of auditory acclimatization and adjustment is needed for new users to become accustomed to their devices. The aim of the present study was to test the idea that auditory acclimatization and adjustment to hearing aids involves a proces...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000366

    authors: Dawes P,Munro KJ

    更新日期:2017-03-01 00:00:00