Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics.

Abstract:

:Background Radiomics extracts features from medical images more precisely and more accurately than visual assessment. However, radiomics features are affected by CT scanner parameters such as reconstruction kernel or section thickness, thus obscuring underlying biologically important texture features. Purpose To investigate whether a compensation method could correct for the variations of radiomic feature values caused by using different CT protocols. Materials and Methods Phantom data involving 10 texture patterns and 74 patients in cohorts 1 (19 men; 42 patients; mean age, 60.4 years; September-October 2013) and 2 (16 men; 32 patients; mean age, 62.1 years; January-September 2007) scanned by using different CT protocols were retrospectively included. For any radiomic feature, the compensation approach identified a protocol-specific transformation to express all data in a common space that were devoid of protocol effects. The differences in statistical distributions between protocols were assessed by using Friedman tests before and after compensation. Principal component analyses were performed on the phantom data to evaluate the ability to distinguish between texture patterns after compensation. Results In the phantom data, the statistical distributions of features were different between protocols for all radiomic features and texture patterns (P < .05). After compensation, the protocol effect was no longer detectable (P > .05). Principal component analysis demonstrated that each texture pattern was no longer displayed as different clusters corresponding to different imaging protocols, unlike what was observed before compensation. The correction for scanner effect was confirmed in patient data with 100% (10 of 10 features for cohort 1) and 98% (87 of 89 features for cohort 2) of P values less than .05 before compensation, compared with 30% (three of 10) and 15% (13 of 89) after compensation. Conclusion Image compensation successfully realigned feature distributions computed from different CT imaging protocols and should facilitate multicenter radiomic studies. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Steiger and Sood in this issue.

journal_name

Radiology

journal_title

Radiology

authors

Orlhac F,Frouin F,Nioche C,Ayache N,Buvat I

doi

10.1148/radiol.2019182023

subject

Has Abstract

pub_date

2019-04-01 00:00:00

pages

53-59

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

291

pub_type

杂志文章,多中心研究
  • Chronic mesenteric ischemia: evaluation with phase-contrast cine MR imaging.

    abstract:PURPOSE:To compare superior mesenteric artery (SMA) blood flow in healthy volunteers and patients with stenoses in the fasting state and after food intake by using phase-contrast (PC) cine magnetic resonance (MR) imaging. MATERIALS AND METHODS:Ten healthy subjects, four asymptomatic patients (three with 50% stenosis, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.1.8259400

    authors: Li KC,Whitney WS,McDonnell CH,Fredrickson JO,Pelc NJ,Dalman RL,Jeffrey RB Jr

    更新日期:1994-01-01 00:00:00

  • Laryngeal or hypopharyngeal squamous cell carcinoma: can follow-up CT after definitive radiation therapy be used to detect local failure earlier than clinical examination alone?

    abstract:PURPOSE:To determine if follow-up computed tomography (CT) after definitive radiation therapy for laryngeal or hypopharyngeal (laryngopharyngeal) carcinoma allows the detection of local failure earlier than clinical examination alone. MATERIALS AND METHODS:Pre- and post-radiation therapy follow-up CT scans in 66 patie...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.214.3.r00fe13683

    authors: Hermans R,Pameijer FA,Mancuso AA,Parsons JT,Mendenhall WM

    更新日期:2000-03-01 00:00:00

  • Quantitative digital subtraction angiography: two scanning techniques for correction of scattered radiation and veiling glare. Work in progress.

    abstract::Scattered radiation and veiling glare in digital subtraction angiography degrade contrast signals in a nonlinear and nonuniform way. This effect prohibits direct use of image data for accurate iodine measurement or energy subtraction imaging. Two techniques based on the use of scanning lead bars were proposed to measu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.157.1.3898220

    authors: Shaw CG,Plewes DB

    更新日期:1985-10-01 00:00:00

  • Comparison of the image quality of 105mm film with conventional film.

    abstract::The contrast, resolution, geometric, and motion unsharpness, mottle, and overall impression of 105mm film were compared to these quantities in conventional spot film. It is believed that conventional filming is superior for low contrast objects and cooperative patients whereas with uncooperative, obese patients, the 1...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.2.433

    authors: Skucas J,Gorski JW

    更新日期:1976-02-01 00:00:00

  • Unusual artifact with mammography film.

    abstract::The authors identified the origin of a high-density artifact with mammography film. An acrylic ramp phantom (thickness, 0-7 cm) was used to create a continuously variable radiation exposure. A perturbation in the curve of optical density versus position along the ramp was observed. Development of the film with the emu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.206.3.9494510

    authors: Hedrick WR,Poulton TB,Starchman DE,Tobias TE

    更新日期:1998-03-01 00:00:00

  • Contrast agents lower ventricular fibrillation threshold.

    abstract::Ventricular fibrillation thresholds were measured in anesthetized, closed-chest dogs during the injection of Renografin 76 or Conray 400 into the left coronary artery. Both agents significantly lowered fibrillation threshold--Renografin to 58 +/- 7%; Conray to 20 +/- 5% of control, respectively. The experimental metho...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.1.215

    authors: Wolf GL,Kraft L,Kilzer K

    更新日期:1978-10-01 00:00:00

  • Intracranial vascular malformations: MR and CT imaging.

    abstract::Twenty-four patients with 29 cerebrovascular malformations were evaluated with a combination of computed tomography (CT), angiography, and magnetic resonance (MR) imaging. Characteristics of the malformations on MR images were reviewed retrospectively, and a comparative evaluation of MR and CT images was made. Of 14 a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.2.4011900

    authors: Kucharczyk W,Lemme-Pleghos L,Uske A,Brant-Zawadzki M,Dooms G,Norman D

    更新日期:1985-08-01 00:00:00

  • Rotator Cuff Calcific Tendinopathy: Randomized Comparison of US-guided Percutaneous Treatments by Using One or Two Needles.

    abstract::Purpose To determine whether the use of one or two needles influences procedure performance and patient outcomes for ultrasonography (US)-guided percutaneous irrigation of calcific tendinopathy. Materials and Methods Institutional review board approval and written informed patient consent were obtained. From February ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017162888

    authors: Orlandi D,Mauri G,Lacelli F,Corazza A,Messina C,Silvestri E,Serafini G,Sconfienza LM

    更新日期:2017-11-01 00:00:00

  • Coal worker's pneumoconiosis: CT assessment in exposed workers and correlation with radiographic findings.

    abstract::To study the signs of coal worker's pneumoconiosis (CWP) at computed tomography (CT), the authors obtained thoracic CT scans in 170 coal-dust-exposed workers who were concomitantly evaluated with conventional posteroanterior and lateral radiography. The profusion and extent of disease was assessed by means of CT in tw...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.177.2.2217770

    authors: Remy-Jardin M,Degreef JM,Beuscart R,Voisin C,Remy J

    更新日期:1990-11-01 00:00:00

  • Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience.

    abstract::The authors investigated the contrast enhancement characteristics of the coronary artery stent lumen to assess patency and then evaluated the accuracy of computed tomographic (CT) measurement of the in-stent luminal diameter. Nineteen patients (16 men and three women; mean age, 58.7 years) with 26 stents underwent car...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2331031564

    authors: Hong C,Chrysant GS,Woodard PK,Bae KT

    更新日期:2004-10-01 00:00:00

  • Management of Uterine Fibroids: A Focus on Uterine-sparing Interventional Techniques.

    abstract::Uterine fibroids occur in approximately 50% of women over the age of 40 years, and an estimated 50% of those are symptomatic. Menorrhagia is the most common symptom and the primary indication for treatment, although bulk symptoms often occur and can be treated. Pharmacotherapy is typically inadequate unless it can be ...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2016141693

    authors: Silberzweig JE,Powell DK,Matsumoto AH,Spies JB

    更新日期:2016-09-01 00:00:00

  • Enhancement of parallel MR image acquisition by rotation of the plane of section.

    abstract::The technique of simultaneous acquisition of magnetic resonance images from two different locations was combined with a modification of a commercially available oblique multisection method. By angling the sections slightly from the coronal plane and rotating the subject, simultaneous sections can be obtained within th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.3.3340790

    authors: Kneeland JB,Jesmanowicz A,Hyde JS

    更新日期:1988-03-01 00:00:00

  • Noninvasive breast cancer.

    abstract::Noninvasive breast cancer comprises two distinct entities, lobular carcinoma in situ (LCIS) and ductal carcinoma in situ (DCIS). The increased use of screening mammography has caused more cases of noninvasive breast cancer to be discovered. However, the increased detection of LCIS and DCIS has posed problems in patien...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.190.3.8115600

    authors: Rebner M,Raju U

    更新日期:1994-03-01 00:00:00

  • Cerebral amyloidosis: postmortem detection with human 7.0-T MR imaging system.

    abstract:PURPOSE:To explore the ability of whole-body 7.0-T magnetic resonance (MR) imaging to depict differences in aspects of the cerebral cortex of postmortem human brain specimens with cerebral amyloid beta deposition in connection with Alzheimer disease (AD), Down syndrome, or sporadic or hereditary cerebral amyloid angiop...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2533090490

    authors: van Rooden S,Maat-Schieman ML,Nabuurs RJ,van der Weerd L,van Duijn S,van Duinen SG,Natté R,van Buchem MA,van der Grond J

    更新日期:2009-12-01 00:00:00

  • Beyond the Cuff: MR Imaging of Labroligamentous Injuries in the Athletic Shoulder.

    abstract::Shoulder disease is common in the athletic population and may arise as a consequence of a single traumatic episode or multiple repeated events. Associated labroligamentous injuries can result in substantial disability. Specific athletic and occupational activities result in predictable injury patterns. Imaging in gene...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2015150364

    authors: Roy EA,Cheyne I,Andrews GT,Forster BB

    更新日期:2016-02-01 00:00:00

  • Desmoplastic small round cell tumor of the abdomen: radiologic-histopathologic correlation.

    abstract:PURPOSE:To characterize the imaging features of desmoplastic small round cell tumor of the abdomen and correlate them with the histopathologic findings. MATERIALS AND METHODS:Eleven of 14 patients with desmoplastic small round cell tumor had primary abdominal involvement. In nine of these patients (mean age, 20 years)...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.210.3.r99mr42633

    authors: Pickhardt PJ,Fisher AJ,Balfe DM,Dehner LP,Huettner PC

    更新日期:1999-03-01 00:00:00

  • Congenital neuroblastoma: evaluation with multimodality imaging.

    abstract::The authors retrospectively evaluated 12 patients with congenital (neonatal) neuroblastoma to assess the utility of newer imaging modalities. Findings at prenatal ultrasound (US), performed in four patients, were nonspecific (hydramnios and hydrops fetalis) in two and consistent with a suprarenal mass (one solid, one ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.175.2.2183280

    authors: Forman HP,Leonidas JC,Berdon WE,Slovis TL,Wood BP,Samudrala R

    更新日期:1990-05-01 00:00:00

  • Gastrointestinal tract focal mass lesions: role of CT and barium evaluations.

    abstract::Fifty-eight patients with focal mass lesions involving the gastrointestinal tract were studied retrospectively. The diagnostic value of CT scans was seen by assessing the barium studies alone, then by combined review of radiographs and CT scans. Patient management decision making was similarly evaluated. CT scanning a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.3.3753800

    authors: Coscina WF,Arger PH,Levine MS,Herlinger H,Cohen S,Coleman BG,Mintz MC

    更新日期:1986-03-01 00:00:00

  • Splenic flexure carcinoma as a source of hepatic portal venous gas.

    abstract::Most patients with hepatic portal venous gas are seriously ill with some combination of bowel ischemia, distension, and/or necrosis. The authors report a case in which a necrotic splenic flexure carcinoma seeded gas and septic thrombi to the liver. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.2.329

    authors: Gold RP,Seaman WB

    更新日期:1977-02-01 00:00:00

  • Metastatic prostate cancer: initial findings of PET with 2-deoxy-2-[F-18]fluoro-D-glucose.

    abstract:PURPOSE:To evaluate the accuracy of positron emission tomography (PET) with 2-deoxy-2-[fluorine-18] fluoro-D-glucose (FDG) in the detection of osseous and soft-tissue metastases of prostate cancer. MATERIALS AND METHODS:Thirty-four patients (mean age, 71 years) with biopsy-proved prostate cancer and known or suspected...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.3.8638000

    authors: Shreve PD,Grossman HB,Gross MD,Wahl RL

    更新日期:1996-06-01 00:00:00

  • Dynamic US of the anterior band of the ulnar collateral ligament of the elbow in asymptomatic major league baseball pitchers.

    abstract:PURPOSE:To determine whether dynamic ultrasonography (US) can reveal abnormalities of the anterior band of the ulnar collateral ligament (UCL) of the elbow in asymptomatic major league professional baseball players. MATERIALS AND METHODS:US was performed in 26 asymptomatic major league professional baseball pitchers b...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2271020288

    authors: Nazarian LN,McShane JM,Ciccotti MG,O'Kane PL,Harwood MI

    更新日期:2003-04-01 00:00:00

  • Magnetic resonance imaging of the lymph nodes: comparison with CT.

    abstract::This retrospective study of 144 patients was made to (a) assess the potential of magnetic resonance (MR) for demonstrating lymph nodes using spin-echo technique, (b) compare the MR results with those of CT, and (c) determine the optimal pulse-sequence interval (TR) and echo-delay time (TE) for imaging lymph nodes. The...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.153.3.6093190

    authors: Dooms GC,Hricak H,Crooks LE,Higgins CB

    更新日期:1984-12-01 00:00:00

  • Superficial esophageal cancer: multicenter analysis of results of definitive radiation therapy in Japan.

    abstract:PURPOSE:To assess the effectiveness of definitive radiation therapy in patients with superficial esophageal cancer. MATERIALS AND METHODS:Method of irradiation, local control rate, survival rate, and complications were assessed in 105 patients (89 men, 16 women; age range, 50-88 years) with superficial esophageal canc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.1.7784580

    authors: Okawa T,Tanaka M,Kita-Okawa M,Nishio M,Kikuchi Y,Shirato H,Yamada S,Asakawa H,Niibe H,Dokiya T

    更新日期:1995-07-01 00:00:00

  • Tunneled central venous access catheter placement in the pediatric population: comparison of radiologic and surgical results.

    abstract:PURPOSE:To compare the success and infection rates of radiologic placement with those of surgical placement of tunneled central venous access catheters (TCVACs) in infants and small children. MATERIALS AND METHODS:In 17 pediatric patients, TCVACs were placed with vascular access under ultrasound or fluoroscopic guidan...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.1.8208950

    authors: Nosher JL,Shami MM,Siegel RL,DeCandia M,Bodner LJ

    更新日期:1994-07-01 00:00:00

  • US Molecular Imaging of Acute Ileitis: Anti-Inflammatory Treatment Response Monitored with Targeted Microbubbles in a Preclinical Model.

    abstract::Purpose To evaluate whether dual-selectin-targeted US molecular imaging allows longitudinal monitoring of anti-inflammatory treatment effects in an acute terminal ileitis model in swine. Materials and Methods The Institutional Animal Care and Use Committee approved all animal studies. Fourteen swine with chemically in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018172600

    authors: Wang H,Hyvelin JM,Felt SA,Guracar I,Vilches-Moure JG,Cherkaoui S,Bettinger T,Tian L,Lutz AM,Willmann JK

    更新日期:2018-10-01 00:00:00

  • Impact of Medicare Shared Savings Program Accountable Care Organizations at Screening Mammography: A Retrospective Cohort Study.

    abstract::Purpose To evaluate the impact of accountable care organizations (ACOs) on use of screening mammography in the Medicare Shared Savings Program (MSSP), the largest value-based reimbursement program in U.S. HISTORY:Materials and Methods Institutional review board approval was waived, as the study used publicly availabl...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016160554

    authors: Narayan AK,Harvey SC,Durand DJ

    更新日期:2017-02-01 00:00:00

  • Venous renal tumor extension: a prospective US evaluation.

    abstract::To evaluate the ability of ultrasonography (US) to determine venous tumor extension, we studied 120 consecutive patients with renal neoplasms. The incidence of renal vein involvement in this group was 18%; caval tumor extension occurred in 11% of the patients. Real-time US clearly visualized the entire retrohepatic in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.2.3892580

    authors: Schwerk WB,Schwerk WN,Rodeck G

    更新日期:1985-08-01 00:00:00

  • Thin-walled cystic lesions in bronchioalveolar carcinoma.

    abstract::In a retrospective study, thin-walled cystic lesions were identified in four patients with proved bronchioalveolar carcinoma (BAC). The radiographic appearances are described, and possible mechanisms of formation of the lesions are discussed. Although such appearances due to BAC have rarely been described in the liter...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.185.2.1329140

    authors: Weisbrod GL,Towers MJ,Chamberlain DW,Herman SJ,Matzinger FR

    更新日期:1992-11-01 00:00:00

  • Computer-aided detection in digital mammography: comparison of craniocaudal, mediolateral oblique, and mediolateral views.

    abstract:PURPOSE:To retrospectively compare the sensitivity of a computer-aided detection (CAD) system for depicting breast cancer in three digital mammographic views. MATERIALS AND METHODS:This study was conducted with institutional review board approval; informed consent was waived. A commercially available CAD system was ap...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2413051145

    authors: Kim SJ,Moon WK,Cho N,Cha JH,Kim SM,Im JG

    更新日期:2006-12-01 00:00:00

  • Mesial temporal sclerosis: diagnosis with fluid-attenuated inversion-recovery versus spin-echo MR imaging.

    abstract:PURPOSE:To compare the accuracy of a fluid-attenuated inversion-recovery (FLAIR) sequence with that of a conventional double spin-echo (SE) sequence in the identification of increased signal intensity of the hippocampus in mesial temporal sclerosis (MTS). MATERIALS AND METHODS:Three blinded reviewers independently gra...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.2.8668780

    authors: Jack CR Jr,Rydberg CH,Krecke KN,Trenerry MR,Parisi JE,Rydberg JN,Cascino GD,Riederer SJ

    更新日期:1996-05-01 00:00:00